Method Development for High Temperature In-Situ Neutron Diffraction Measurements of Glass Crystallization on Cooling from Melt

A glass-ceramic borosilicate waste form is being considered for immobilization of waste streams of alkali, alkaline-earth, lanthanide, and transition metals generated by transuranic extraction for reprocessing used nuclear fuel. Waste forms are created by partial crystallization on cooling, primarily of oxyapatite and powellite phases. In-situ neutron diffraction experiments were performed to obtain detailed information about crystallization upon cooling from 1200°C. The combination of high temperatures and reactivity of borosilicate glass with typical containers used in neutron experiments, such as vanadium and niobium, prevented their use here. Thus, methods using sealed thick-walled silica ampoules were developed for the in-situ studies. Unexpectedly, high neutron absorption, low crystal fraction, and high silica container background made quantification difficult for these high temperature measurements. As a follow-up, proof-of-concept measurements were performed on different potential high-temperature container materials, emphasizing crystalline materials so that residual glass in the waste form sample could be more easily analyzed. Room temperature measurements were conducted with a pre-crystallized sample in ‘ideal’ containers stable at low temperatures (i.e., vanadium and thin-wall silica capillaries) and compared to the same measurements in containers stable at high temperatures (i.e, platinum, single crystal sapphire, and thick-walled silica ampoules). Results indicated that Pt is probably the best choice if suitably sealed to prevent contamination from the sample after neutron activation.

36 MATERIALS SCIENCE↗

Geometry Survey of the Time-of-Flight Neutron-Elastic Scattering (Antonella) Experiment

The Antonella experiment is a measurement of the ionization efficiency of nuclear recoils in silicon at low energies [1]. It is a neutron elastic scattering experiment motivated by the search for dark matter particles. In this experiment, a proton beam hits a lithium target and neutrons are produced. The neutron shower passes through a collimator that produces a neutron beam. The beam illuminates a silicon detector. With a certain probability, a neutron interacts with a silicon nucleus of the detector producing elastic scattering. After the interaction, a fraction of the neutron energy is transferred to the silicon nucleus which acquires kinetic energy and recoils. This kinetic energy is then dissipated in the detector producing ionization and thermal energy. The ionization produced is measured with the silicon detector electronics. On the other hand, the neutron is scattered out of the beam. A neutron-detector array (made of scintillator bars) registers the neutron arrival time and the scattering angle to reconstruct the kinematics of the neutron-nucleus interaction with the time-of-flight technique [2]. In the reconstruction equations, the energy of the nuclear recoil is a function of the scattering angle with respect to the beam direction, the time-of-flight of the neutron and the geometric distances between components of the setup (neutron-production target, silicon detector, scintillator bars). This paper summarizes the survey of the different components of the experiment that made possible the off-line analysis of the collected data. Measurements were made with the API Radian Laser Tracker and I-360 Probe Wireless. The survey was completed at the University of Notre Dame, Indiana, USA in February 2015.

Oshinowo, Babatunde O.↗

A compact in situ polarized 3He neutron spin filter for the diffractometer VULCAN at the Spallation Neutron Source

We have built and commissioned a compact in situ 3He polarizer based on spin-exchange optical pumping for the engineering materials diffractometer, named VULCAN, at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory. The system achieved 78% 3He polarization with a short pump-up time constant of 2.2 h. Its first deployment in an in situ half-polarized neutron diffraction experiment on a magnetic shape memory alloy, Ni–Mn–Ga, revealed changes in magnetization coupled to deformation twinning under compression. With this new capability, VULCAN has become the first diffractometer at SNS capable of performing polarized neutron experiments, opening new opportunities to study a wider range of magnetism-related material behaviors under varied thermal, mechanical, electrical, and/or magnetic fields.

Fu, Sichao [ORNL] (ORCID:0009000846771640)↗

Chemical composition induced quantum phase transition in Cs 1 - x Rb x FeCl 3

Here, the isostructural series of S =1 quantum magnets Cs 1- x Rb x FeCl 3 is investigated, using both thermodynamic measurements and inelastic neutron scattering experiments. It is found that with increasing Rb content the system evolves from the gapped state at x =0, through a quantum phase transition at x∼0.35, and to the magnetically ordered state at larger x . Inelastic neutron experiments for x =0, x =0.3, and x =1 demonstrate that the magnetic anisotropy and spin interactions are continuously tuned by the chemical composition. Finally, for the intermediate concentration all magnetic excitations are substantially broadened suggesting that disorder plays a key role in this species. For the two end compounds, excitations remain sharp.

36 MATERIALS SCIENCE↗

Preparation of thin arsenic and radioarsenic targets for neutron capture studies

A simple method for the electrodeposition of elemental arsenic (As) on a metal backing from aqueous solutions has been developed. The method was successfully applied to stable As (As-75). Thin (2.5 mg {center_dot} cm{sup -2}) coherent, smooth layers of the metalloid on Ti foils (2.5 {micro}m thickness) were obtained. Electrodeposits served as targets for {sup 75}As(n,{gamma}) {sup 76}As neutron capture experiments at Los Alamos Neutron Science Center (LANSCE). Respective {sup 73}As(n,{gamma}) {sup 74}As experiments are planned for the near future, and {sup 73}As targets will be prepared in a similar fashion utilizing the introduced electrodeposition method. The preparation of an {sup 73}As (half-life 80.3 d) plating bath solution from proton irradiated germanium has been demonstrated. Germanium target irradiation was performed at the Los Alamos Isotope Production Facility (IPF).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Status of the UCN τ experiment

The neutron is the simplest nuclear system that can be used to probe the structure of the weak interaction and search for physics beyond the standard model. Measurements of neutron lifetime and β-decay correlation coefficients with precisions of 0.02% and 0.1%, respectively, would allow for stringent constraints on new physics. The UCNτ experiment uses an asymmetric magneto-gravitational UCN trap with in situ counting of surviving neutrons to measure the neutron lifetime, τn = 877.7s (0.7s)stat (+0.4/-0.2s)sys. We discuss the recent result from UCNτ, the status of ongoing data collection and analysis, and the path toward a 0.25 s measurement of the neutron lifetime with UCNτ.

Pattie, R. W.↗

Charge-Injection-Device Performance in the High-Energy-Neutron Environment of Laser-Fusion Experiments

Charge-injection devices (CIDs) are being used to image x rays in laser-fusion experiments on the University of Rochester’s OMEGA Laser System. The CID cameras are routinely used up to the maximum neutron yields generated (~10^14 DT). The detectors are deployed in x-ray pinhole cameras and Kirkpatrick–Baez microscopes. The neutron fluences ranged from ~10^7 to ~10^9 neutrons/cm^2 and useful x-ray images were obtained even at the highest fluences. It is intended to use CID cameras at the National Ignition Facility (NIF) as a supporting means of recording x-ray images. The results of this work predict that x-ray images should be obtainable on the NIF at yields up to ~10^15, depending on distance and shielding.

Marshall, F J↗

An automated analysis workflow for optimization of force-field parameters using neutron scattering data

Graphical abstract: - Highlights: • An automated workflow to optimize force-field parameters. • Used the workflow to optimize force-field parameter for a system containing nanodiamond and tRNA. • The mechanism relies on molecular dynamics simulation and neutron scattering experimental data. • The workflow can be generalized to any other experimental and simulation techniques. - Abstract: Large-scale simulations and data analysis are often required to explain neutron scattering experiments to establish a connection between the fundamental physics at the nanoscale and data probed by neutrons. However, to perform simulations at experimental conditions it is critical to use correct force-field (FF) parameters which are unfortunately not available for most complex experimental systems. In this work, we have developed a workflow optimization technique to provide optimized FF parameters by comparing molecular dynamics (MD) to neutron scattering data. We describe the workflow in detail by using an example system consisting of tRNA and hydrophilic nanodiamonds in a deuterated water (D{sub 2}O) environment. Quasi-elastic neutron scattering (QENS) data show a faster motion of the tRNA in the presence of nanodiamond than without the ND. To compare the QENS and MD results quantitatively, a proper choice of FF parameters is necessary. We use an efficient workflow to optimize the FF parameters between the hydrophilic nanodiamond and water by comparing to the QENS data. Our results show that we can obtain accurate FF parameters by using this technique. The workflow can be generalized to other types of neutron data for FF optimization, such as vibrational spectroscopy and spin echo.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Mitigation of backgrounds from cosmogenic 137 Xe in xenon gas experiments using 3 He neutron capture

136 Xe is used as the target medium for many experiments searching for 0νββ. Despite underground operation, cosmic muons that reach the laboratory can produce spallation neutrons causing activation of detector materials. A potential background that is difficult to veto using muon tagging comes in the form of 137 Xe created by the capture of neutrons on 136 Xe. This isotope decays via beta decay with a half-life of 3.8 minutes and a Q β of ~4.16 MeV. This work proposes and explores the concept of adding a small percentage of 3 He to xenon as a means to capture thermal neutrons and reduce the number of activations in the detector volume. When using this technique we find the contamination from 137 Xe activation can be reduced to negligible levels in tonne and multi-tonne scale high pressure gas xenon neutrinoless double beta decay experiments running at any depth in an underground laboratory.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Mitigation of Backgrounds from Cosmogenic $^{137}$Xe in Xenon Gas Experiments using $^{3}$He Neutron Capture

\Xe{136} is used as the target medium for many experiments searching for \bbnonu. Despite underground operation, cosmic muons that reach the laboratory can produce spallation neutrons causing activation of detector materials. A potential background that is difficult to veto using muon tagging comes in the form of \Xe{137} created by the capture of neutrons on \Xe{136}. This isotope decays via beta decay with a half-life of 3.8 minutes and a \Qb\ of $\sim$4.16 MeV. This work proposes and explores the concept of adding a small percentage of \He{3} to xenon as a means to capture thermal neutrons and reduce the number of activations in the detector volume. When using this technique we find the contamination from \Xe{137} activation can be reduced to negligible levels in tonne and multi-tonne scale high pressure gas xenon neutrinoless double beta decay experiments running at any depth in an underground laboratory.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Alternative analysis of the MINERVE ZPR oscillation experiments

Delayed neutrons are of fundamental importance in the field of nuclear reactor dynamics and control. However, the precursor yield fraction for a given nuclear reactor are dependent on the properties of the reactor. Thus, in-pile experiments, such as oscillation experiments are conducted in order to measure those values. In this work, an alternative analysis of the piston oscillation experiments that have been conducted in the MINERVE reactor in 2013 is performed. A new method which evolves effective terms that cancel out undesired drifts of the flux during the experiments is presented. The evaluation of the uncertainty on the values of the response function is also presented. Moreover, the effective delayed neutron fraction β{sub eff} is evaluated and is compared to results in previous works. As the analysis has led to an estimation of β{sub eff} with a large uncertainty, it has been deduced that the oscillation experiments that have been conducted in MINERVE are not a reliable method of experimentation to determine the value of β{sub eff} in the reactor and that the noise experiments are better suited for that purpose.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Strongly-Paired Fermions: Cold Atoms and Neutron Matter

Experiments in cold Fermi atoms can be tuned to probe strongly-interacting fluids very similar to the low-density neutron matter found in the crusts of neutron stars. In contrast to traditional superfluids and superconductors, matter in this regime is very strongly paired, with gaps of order the Fermi energy. We compute the T=0 equation of state and pairing gaps for cold atoms and low-density neutron matter as a function of the Fermi momentum times the scattering length (κFa). Results of Quantum Monte Carlo calculations show that the equations of state are very similar. The neutron matter pairing gap at low densities is found to be very large but, except at the smallest densities, significantly suppressed relative to cold atoms because of the finite effective range.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Neutron-induced fission cross section of {sup nat}Pb and {sup 209}Bi from threshold to 1 GeV: An improved parametrization

Neutron-induced fission cross sections for {sup nat}Pb and {sup 209}Bi were measured with a white-spectrum neutron source at the CERN Neutron Time-of-Flight (n{sub T}OF) facility. The experiment, using neutrons from threshold up to 1 GeV, provides the first results for these nuclei above 200 MeV. The cross sections were measured relative to {sup 235}U and {sup 238}U in a dedicated fission chamber with parallel plate avalanche counter detectors. Results are compared with previous experimental data. Upgraded parametrizations of the cross sections are presented, from threshold energy up to 1 GeV. The proposed new sets of fitting parameters improve former results along the whole energy range.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

PERFORMING DIAGNOSTICS ON THE SPALLATION NEUTRON SOURCE VISION BEAM LINE TO ELIMINATE HIGH VIBRATION LEVELS AND PROVIDE A SUSTAINABLE OPERATION

The Spallation Neutron Source (SNS) at the Oak Ridge National Laboratory (ORNL) provides variable energy neutrons for a variety of experiments. The neutrons proceed down beam lines to the experiment hall, which houses a variety of experiments and test articles. Each beam line has one or more neutron choppers which filter the neutron beam based on the neutron energy by using a rotating neutron absorbing material passing through the neutron beam. Excessive vibration of the Vision beam line, believed to be caused by the T0 chopper, prevented the Vision beam line from operating at full capacity. This problem had been addressed several times by rebalancing/reworking the T0 beam chopper but the problem stubbornly persisted. To determine the cause of the high vibration, dynamic testing was performed. Twenty-seven accelerometer and motor current channels of data were collected during drive up, drive down, coast down, and steady-state conditions; resonance testing and motor current signature analysis were also performed. The data was analyzed for traditional mechanical/machinery issues such as misalignment and imbalance using time series analysis, frequency domain analysis, and operating deflection shape analysis. The analysis showed that the chopper base plate was experiencing an amplified response to the excitation provided by the T0 beam chopper. The amplified response was diagnosed to be caused by higher than expected base plate flexibility, possibly due to improper grouting or loose floor anchors. Based on this diagnosis, a decision was made to dismantle the beam line chopper and remount the base plate. Neutron activation of the beam line components make modifications to the beam line especially expensive and time consuming due to the radiation handling requirements, so this decision had significant financial and schedule implications. It was found that the base plate was indeed loose because of improper grouting during its initial installation. The base plate was modified by splitting it into multiple sections, isolating the T0 chopper from the rest of the beam line, and each section was then reinstalled and re-grouted. After these modifications, the vibration levels were reduced by a factor of 30. The reduction in vibration level was sufficient to allow the Vision beam line to operate at full capacity for the first time since its completed construction date.

: Diagnostics↗

Strongly paired fermions: Cold atoms and neutron matter

Experiments with cold Fermi atoms can be tuned to probe strongly-interacting fluids that are very similar to the low-density neutron matter found in the crusts of neutron stars. In contrast to traditional superfluids and superconductors, matter in this regime is very strongly paired, with gaps of the order of the Fermi energy. We compute the T=0 equation of state and pairing gap for cold atoms and low-density neutron matter as a function of the Fermi momentum times the scattering length. Results of quantum Monte Carlo calculations show that the equations of state are very similar. The neutron matter pairing gap at low densities is found to be very large but, except at the smallest densities, significantly suppressed relative to cold atoms because of the finite effective range in the neutron-neutron interaction.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Investigation of Energy Selective Neutron Imaging at the PULSTAR Reactor

Neutron imaging is complementary to X-ray imaging where both are used to investigate the internal features of objects nondestructively. Historically, it only began three years after discovery of the neutron in 1932, however, neutron radiographs with reasonable quality were first made in the mid-fifties. Conventionally, the image is produced by placing the object between the neutron source and a two-dimensional position sensitive detector. The source commonly has a full energy spectrum (white beam) of thermal or cold neutrons to obtain high intensity in the sample and short exposure time. As a result, all neutron energies contribute to the obtained radiograph. Since the interaction of the neutron with matter is energy dependent, different energies produce different contrast on the radiographic image, hence, additional information about the object can be obtained. Neutron imaging that utilizes a narrow spectrum of energy instead of white beam is called energy selective neutron imaging. Many techniques have been explored to select a narrow band of neutron energy for the use in imaging such as the use velocity selectors, double crystal Monochromators, and time of flight techniques (at pulsed neutron sources). The PULSTAR reactor of North Carolina State University (1 MWth) currently has an operational neutron powder diffractometer (NPD) installed on beam tube no. 4, which was designed for neutron scattering experiments and can provide a monoenergetic beam of neutrons. The neutron energy could be selected by diffraction means using a Si bent perfect crystal as a Monochromator. In this work, an investigation of energy selective neutron imaging at the NPD is discussed in terms of the system performance and the ability of material discrimination on a test sample by observing the contrast variations of the neutron radiographs obtained using different neutron energies. Energy selective neutron imaging experiment was successfully tested at the PULSTAR reactor's NPD. Although, the uniform region is small and the exposure time is long in comparison with the NIF, both facilities exhibit similar spatial resolution which is a very important characteristic for any imaging facility. The contrast variation of neuron radiographs for the test sample obtained at different energies indicated a potential advantage for using energy selective neutron imaging over the white beam. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

New high-sensitivity searches for neutrons converting into antineutrons and/or sterile neutrons at the HIBEAM/NNBAR experiment at the European Spallation Source

The violation of baryon number, , is an essential ingredient for the preferential creation of matter over antimatter needed to account for the observed baryon asymmetry in the Universe. However, such a process has yet to be experimentally observed. The HIBEAM/NNBAR program is a proposed two-stage experiment at the European Spallation Source to search for baryon number violation. The program will include high-sensitivity searches for processes that violate baryon number by one or two units: free neutron–antineutron oscillation () via mixing, neutron–antineutron oscillation via regeneration from a sterile neutron state (), and neutron disappearance (n → n′); the effective process of neutron regeneration () is also possible. The program can be used to discover and characterize mixing in the neutron, antineutron and sterile neutron sectors. The experiment addresses topical open questions such as the origins of baryogenesis and the nature of dark matter, and is sensitive to scales of new physics substantially in excess of those available at colliders. A goal of the program is to open a discovery window to neutron conversion probabilities (sensitivities) by up to three orders of magnitude compared with previous searches. The opportunity to make such a leap in sensitivity tests should not be squandered. The experiment pulls together a diverse international team of physicists from the particle (collider and low energy) and nuclear physics communities, while also including specialists in neutronics and magnetics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗