Search NASA⌕ Search

SEARCH · Search NASA

Results for “Neutron Source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

RESULTS OF BACKGROUND SUBTRACTION TECHNIQUES ON THE SPALLATION NEUTRON SOURCE BEAM LOSS MONITORS

Recent improvements to the Spallation Neutron Source (SNS) beam loss monitor (BLM) designs have been made with the goal of significantly reducing background noise. This paper outlines this effort and analyzes the results. The significance of this noise reduction is the ability to use the BLM sensors [1], [2], [3] distributed throughout the SNS accelerator as a method to monitor activation of components as well as monitor beam losses.

Beam Loss Monitor↗

Progress on the Proton Power Upgrade at the Spallation Neutron Source

The Proton Power Upgrade Project at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory will double the proton power capability from 1.4 to 2.8 MW. This will be accomplished through an energy increase from 1.0 to 1.3 GeV and a beam current increase from 26 to 38 mA. The energy increase will be accomplished through the addition of 7 cryomodules to the linear accelerator (Linac). The beam current increase will be supported by upgrading several radio-frequency systems in the normal-conducting section of the Linac. Upgrades to the accumulator ring injection and extraction regions will accommodate the increase in beam energy. A new 2-MW-capable target and supporting systems will be developed and installed. Conventional facility upgrades include build-out of the existing klystron gallery and construction of a tunnel stub to facilitate future beam transport to the second target station. The project received approval to proceed with construction in October 2020. Procurements are in progress, and some installation activities have already occurred. Most of the installation will take place during three outages in 2022-2023. The project early finish is planned for 2025.

Barbier, Charlotte↗

Preliminary study of nuclear fuel element testing based on coded source neutron imaging

Neutron radiography (NR) is one of the most important nondestructive testing methods, which is sensitive to low density materials. Especially, Neutron transfer imaging method could be used to test radioactivity materials refraining from γ effect, but it is difficult to realize tomography. Coded source neutron imaging (CSNI) is a newly NR method developed fast in the last several years. The distance between object and detector is much longer than traditional NR, which could be used to test radioactivity materials. With pre-reconstruction process from fold-cover projections, CSNI could easily realize tomography. This thesis carries out preliminary study on the nuclear fuel element testing by coded source neutron imaging. We calculate different enrichment, flaws and activity in nuclear fuel elements tested by CSNI with Monte-Carlo simulation. The results show that CSNI could be a useful testing method for nuclear fuel element testing. (authors)

42 ENGINEERING↗

Initial testing of a Compact Crystal Positioning System for the TOPAZ Single-Crystal Diffractometer at the Spallation Neutron Source

A precise, versatile, and automated method of orienting a sub-millimeter crystal in a focused neutron beam is required for e cient operation of the TOPAZ Single Crystal Di ractometer at the Spallation Neutron Source at Oak Ridge National Laboratory. To ful ll this need, a Compact Crystal Positioning System (CCPS) has been developed in collaboration with Square One Systems Design in Jackson, Wyoming. The system incorporates a tripod design with six vacuum-compatible piezoelectric linear motors capable of < 1 m resolution. National Instruments LabVIEW provides a means of system automation while at the same time accommodating the modular nature of the SNS sample environment control software for straightforward system integration. Initial results in a cryogenic test environment will be presented, as well as results from ambient tests performed at the Advanced Photon Source at Argonne National Laboratory.

43 PARTICLE ACCELERATORS↗

Design and structural assessment of the Spallation Neutron Source 2.0 MW target

The Proton Power Upgrade (PPU) project is underway at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory. The project will double the proton accelerator power from 1.4 MW to 2.8 MW, increase power to the First Target Station (FTS), and enable a future Second Target Station (STS). The power increase partly comes from raising proton energy from 1.0 GeV to 1.3 GeV. The STS will operate at 0.7 MW at 15 Hz when completed. Until then, PPU will provide the capability to operate the FTS at 2.0 MW at 60 Hz. Maximum power at the FTS to date has been 1.4 MW at 60 Hz with 1.0 GeV protons. A new mercury target module design to operate reliably under PPU conditions has been completed after a multi-year effort. The design philosophy and assessment of the structural analysis are described here. This target underwent an unprecedented design and analysis process for SNS using the latest engineering techniques and incorporating years of operating lessons and outcomes from R&D to meet structural design criteria. Finally, it also incorporates high-flow gas injection to further mitigate pulse fatigue stresses as well as cavitation damage to the mercury vessel.

47 OTHER INSTRUMENTATION↗

Fundamental neutron physics beamline at the spallation neutron source at ORNL

In this paper, we describe the Fundamental Neutron Physics Beamline (FnPB) facility located at the Spallation Neutron Source at Oak Ridge National Laboratory. The FnPB was designed for the conduct of experiments that investigate scientific issues in nuclear physics, particle physics, astrophysics and cosmology using a pulsed slow neutron beam. Finally, we present a detailed description of the design philosophy, beamline components, and measured fluxes of the polychromatic and monochromatic beams.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SEEMS: A Single Event Effects and Muon Spectroscopy facility at the Spallation Neutron Source

This study outlines a concept that would leverage the existing proton accelerator at the Spallation Neutron Source (SNS) of Oak Ridge National Laboratory to enable transformative science via one world-class facility serving two missions: Single Event Effects (SEE) and Muon Spectroscopy (μSR). The μSR portion would deliver the world’s highest flux and highest resolution pulsed muon beams for material characterization purposes, with precision and capabilities well beyond comparable facilities. The SEE capabilities deliver neutron, proton, and muon beams for aerospace industries that are facing an impending challenge to certify equipment for safe and reliable behavior under bombardment from atmospheric radiation originating from cosmic and solar rays. With negligible impact on the primary neutron scattering mission of the SNS, the proposed facility will have enormous benefits for both science and industry. Herein, we have designated this facility “SEEMS.”

47 OTHER INSTRUMENTATION↗

X-pinch-based neutron source

Results are presented from experimental studies of the parameters of an X-pinch-based neutron source made of 70- to 80-{mu}m-diameter deuterated polyethylene fibers. At currents of up to 1.7 MA and a current rise time of {approx}150 ns, hot plasma spots were observed in the fiber crossing region. The formation of hot spots was accompanied by the generation of short soft X-ray pulses with a duration of 2-4 ns, as well as by neutron emission. The neutron energy was measured using the time-of-flight technique in four directions, at 0{sup o}, 90{sup o}, 180{sup o}, and 270{sup o} with respect to the load axis. The mean energy of the neutrons emitted along the axis towards the anode and cathode was found to be 2.0 {+-} 0.2 and 2.6 {+-} 0.1 MeV, respectively, and that of neutrons emitted in two opposite directions along the radius, 2.5 {+-} 0.1 and 2.4 {+-} 0.1 MeV. The maximum neutron yield at a current amplitude of 1.6 MA was of 10{sup 10} neutrons per shot.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Upgrade of the Spallation Neutron Source Injection and Extraction Kicker Pulse Verification Systems

The Spallation Neutron Source (SNS) injection system transports a chopped, 1ms H- ion beam from the linac into the accumulator ring, where two electrons are stripped from each ion, resulting in a proton beam propagating in the ring. The injection kickers use a 1400A current source with a 1ms discharge time to paint the optimum phase space of the injected proton population. The accumulation ring stacks 1us bunches from the 1ms beam pulse to increase peak beam current by a factor of ~1000. The accumulated beam is deflected by fourteen 33kV, 700ns pulsed extraction kicker magnets and delivered to the mercury target, where neutrons are spalled for science experiments. Protecting the accelerator from an errant beam—which may result from asynchronous firing or insufficient magnetic-field intensity in kicker systems—requires a system that monitors and verifies the pulsed current in the kicker magnets prior to and during each 60Hz beam pulse. In addition, the extraction system pulse-forming network (PFN) is verified to be correctly charged and ready for triggering prior to injecting the beam into the linac from the ion source. This paper describes the two verification systems requirements, limitations of the existing systems, and development of new systems.

Morris, B↗

The COHERENT Experiment at the Spallation Neutron Source

The COHERENT collaboration's primary objective is to measure coherent elastic neutrino- nucleus scattering (CEvNS) using the unique, high-quality source of tens-of-MeV neutrinos provided by the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL). In spite of its large cross section, the CEvNS process has never been observed, due to tiny energies of the resulting nuclear recoils which are out of reach for standard neutrino detectors. The measurement of CEvNS has now become feasible, thanks to the development of ultra-sensitive technology for rare decay and weakly-interacting massive particle (dark matter) searches. The CEvNS cross section is cleanly predicted in the standard model; hence its measurement provides a standard model test. It is relevant for supernova physics and supernova-neutrino detection, and enables validation of dark-matter detector background and detector-response models. In the long term, precision measurement of CEvNS will address questions of nuclear structure. COHERENT will deploy multiple detector technologies in a phased approach: a 14-kg CsI[Na] scintillating crystal, 15 kg of p-type point-contact germanium detectors, and 100 kg of liquid xenon in a two-phase time projection chamber. Following an extensive background measurement campaign, a location in the SNS basement has proven to be neutron-quiet and suitable for deployment of the COHERENT detector suite. The simultaneous deployment of the three COHERENT detector subsystems will test the N=2 dependence of the cross section and ensure an unambiguous discovery of CEvNS. This document describes concisely the COHERENT physics motivations, sensitivity and plans for measurements at the SNS to be accomplished on a four-year timescale.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Procedure for Evaluating Modified Pulsed-Neutron- Source Experiments in Subcritical Nuclear Reactors

A theoretical interpretation of the modified pulsed-neutron-source experiments of Sjöstrand, Gozani, and Garelis and Russell is given using exact steady-state Boltzmann equations. Here, interpretation is based on a phenomenological description of the experiments and is patterned after work done on the Garelis-Russell method by Corngold. The basic approximation made is that the fundamental prompt-mode decay constant is much larger than any delayed-neutron precursor decay constant. The theoretical interpretation allows the reactivities measured by the above three modified pulsed-source techniques to be easily calculated and compared to more conventional definitions of reactivity. The calculations can be performed by any standard source-iteration code that has been modified to solve the inhomogeneous problem. Experiments were performed on the Cornell University Critical Assembly and interpreted with the aid of the above theory. Calculations and experiments agree to within 20%. Sjöstrand's method is found to give the best result for this reactor.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Mitigating Cathode Overcurrent Faults at the Spallation Neutron Source

The high-power klystron amplifiers at the Spallation Neutron Source (SNS) have been in operation for over 100,000 hours. Overcurrent faults from the klystron cathodes comprise the bulk of RF System downtime. Reliable operation is of particular interest to the SNS, and data from over a decade of operation is used to help mitigate repetitive overcurrent conditions.

Moss, John↗

Study of the neutron flux generated at E-linac-driven neutron sources

We treat generic physical features of the production of neutrons from the high atomic number materials irradiated by the electron beam provided by linear electron accelerator. The bremsstrahlung of incident electrons inducing the photo-nuclear reactions is considered. The experimental data on photo-nuclear reactions are utilized to describe neutrons generating caused by the γ-radiation absorption. The generally received theoretical approaches are applied to explore the photo-neutrons energy distribution. The produced neutrons are primarily statistical, yet the direct neutrons share is noteworthy as well. The dependence of the neutron spectrum, mean neutron energy and total neutron yield on the energy and current of the electron beam and on the characteristics of irradiated samples is investigated. The analysis is plainly carried out in framework of the quantum electrodynamics and photo-nuclear physics, without having any recourse to the “numerical Monte-Carlo simulations”. Our findings prove mainly to conform satisfactorily to the experimental measurements, so far as those are available for now.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Spallation Neutron Source Cryogenic Test Facility Horizontal Test Apparatus Operation

The Spallation Neutron Source (SNS) has built Superconducting Radio Frequency (SRF) processing and testing facilities to support improvement programs and future upgrades. The Cryogenic Test Facility (CTF) system is capable of delivering liquid helium at 4.5K to different test apparatus in support of SRF testing. This paper describes the final stages of fabrication, commissioning and the initial operation of the Horizontal Test Apparatus (HTA). The HTA allows for cold testing of single jacketed medium-beta or high-beta SRF cavities. Heat loads, capacities, and other performance data collected during operation will be presented. Cavity testing lifecycle for plasma processing research and development will be discussed. System changes to allow for 2K helium operation in the HTA will also be addressed.

Afanador, Ralph↗

Spallation Neutron Source Hydrogen Relief Analysis for the Cryogenic Moderator System

The Spallation Neutron Source at Oak Ridge National Laboratory operates the Cryogenic Moderator System (CMS) which provides hydrogen cooling at 20K to three neutron moderators. Each hydrogen loop is protected by multiple burst discs and reclosing relief valves. As a result of the Proton Power Upgrade project, the CMS moderator loops will hold more hydrogen and thus require piping modifications. Operational experience has demonstrated that transient pressure increases in these hydrogen loops occasionally result in the rupture of the burst discs. The causes for pressure transients in the system that might lead to hydrogen venting are varied and complex, for example loss of vacuum or cooling. Dynamic simulation and analysis of the parameters considered as the worst-case relief venting scenario were performed and will be presented.

47 OTHER INSTRUMENTATION↗

Numerical studies of the flux-to-current ratio method in the KIPT neutron source facility

The reactivity of a subcritical assembly has to be monitored continuously in order to assure its safe operation. In this paper, the flux-to-current ratio method has been studied as an approach to provide the on-line reactivity measurement of the subcritical system. Monte Carlo numerical simulations have been performed using the KIPT neutron source facility model. It is found that the reactivity obtained from the flux-to-current ratio method is sensitive to the detector position in the subcritical assembly. However, if multiple detectors are located about 12 cm above the graphite reflector and 54 cm radially, the technique is shown to be very accurate in determining the k{sub eff} this facility in the range of 0.75 to 0.975. (authors)

97 MATHEMATICS AND COMPUTING↗