Search NASA⌕ Search

SEARCH · Search NASA

Results for “Opacity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Thermonuclear Bursts with Short Recurrence Times from Neutron Stars Explained by Opacity-driven Convection

Thermonuclear flashes of hydrogen and helium accreted onto neutron stars produce the frequently observed Type I X-ray bursts. It is the current paradigm that almost all material burns in a burst, after which it takes hours to accumulate fresh fuel for the next burst. In rare cases, however, bursts are observed with recurrence times as short as minutes. We present the first one-dimensional multi-zone simulations that reproduce this phenomenon. Bursts that ignite in a relatively hot neutron star envelope leave a substantial fraction of the fuel unburned at shallow depths. In the wake of the burst, convective mixing events driven by opacity bring this fuel down to the ignition depth on the observed timescale of minutes. There, unburned hydrogen mixes with the metal-rich ashes, igniting to produce a subsequent burst. We find burst pairs and triplets, similar to the observed instances. Our simulations reproduce the observed fraction of bursts with short waiting times of ∼30%, and demonstrate that short recurrence time bursts are typically less bright and of shorter duration.

79 ASTRONOMY AND ASTROPHYSICS↗

Higher order and penumbral blurring correction methodology for Opacity spectrometer used on the NIF

63rd Annual Meeting of the APS Division of Plasma Physics November 8-12, 2021 • Pittsburgh, Pennsylvania Virtual presentation must be uploaded by Nov 3rd 2pm PST Session Date / Time: 11/11/2021, 2:00 pm - 5:00 pm Title: HED: Laboratory Astrophysics Type: Oral Contributed Presentation: Higher order and penumbral blurring correction methodology for Opacity spectrometer used on the NIF.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improved opacity expansion for medium-induced parton splitting

We present a new expansion scheme to compute the rate for parton splittings in dense and finite QCD media. In contrast to the standard opacity expansion, our expansion is performed around the harmonic oscillator whose characteristic frequency depends on the typical transverse momentum scale generated in the splitting. The first two orders account for the high frequency regime that is dominated by single hard scatterings together with the regime of multiple soft scatterings at low frequency. This work generalizes the findings of Ref. [1] beyond the leading logarithmic approximation allowing to account also for the Bethe-Heitler regime and compare to the full numerical results from [2]. We investigate the sensitivity of our results to varying the separation scale that defines the leading order. Finally, the application to Monte Carlo event generators is discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Improved opacity expansion at NNLO for medium induced gluon radiation

When an energetic parton propagates in a hot and dense QCD medium it loses energy by elastic scatterings or by medium-induced gluon radiation. The gluon radiation spectrum is suppressed at high frequency due to the LPM effect and encompasses two regimes that are known analytically: at high frequencies &#x03C9;<!-- ω --> > &#x03C9;<!-- ω --> c = q &#x005E;<!-- ^ --> L 2 , where q &#x005E;<!-- ^ --> is the jet quenching transport coefficient and L the length of the medium, the spectrum is dominated by a single hard scattering, whereas the regime ω < ωc is dominated by multiple low momentum transfers. In this paper, we extend a recent approach (dubbed the Improved Opacity Expansion (IOE)), which allows an analytic (and systematic) treatment beyond the multiple soft scattering approximation, matching this result with the single hard emission spectrum. We calculate in particular the NNLO correction analytically and numerically and show that it is strongly suppressed compared to the NLO indicating a fast convergence of the IOE scheme and thus, we conclude that it is sufficient to truncate the series at NLO. We also propose a prescription to compare the GW and the HTL potentials and relate their parameters for future phenomenological works.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Percutaneous Radiofrequency Ablation of Lung Cancer Presenting as Ground-Glass Opacity

PurposeWe retrospectively evaluated the outcomes of lung cancer patients presenting with ground-glass opacity (GGO) who received radiofrequency ablation (RFA).MethodsSixteen patients (5 men and 11 women; mean age, 72.6 years) with 17 lung cancer lesions showing GGO (mean long axis diameter, 1.6 cm) underwent a total of 20 percutaneous computed tomography (CT) fluoroscopy-guided RFA sessions, including three repeated sessions for local progression. Lung cancer with GGO was defined as a histologically confirmed malignant pulmonary lesion with a GGO component accounting for >50 % of the lesion on high-resolution CT. Procedure outcomes were evaluated.ResultsThere were no major complications. Pneumothorax occurred in 15 of 20 treatment sessions: 14 were asymptomatic, and 1 required chest tube placement but resolved satisfactorily within 48 h. Minor pulmonary hemorrhage occurred in two and mild pneumonitis in one. The median tumor follow-up period was 61.5 (range 6.1–96.6) months. The effectiveness rates of the primary and secondary techniques were 100 and 100 % at 1 year, 93.3 and 100 % at 2 years, and 78.3 and 92.3 % at 3 years, respectively. The median patient follow-up period was 65.6 (range 6.1–96.6) months. One patient died owing to recurrent other cancer 11.7 months after RFA, whereas the other 15 remained alive. Overall survival and disease-specific survival rates were 93.3 and 100 % at 1 year and 93.3 and 100 % at 5 years, respectively.ConclusionsRFA for lung cancer with GGO was safe and effective, and resulted in promising survival rates.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development of an optical sensor for measuring opacity changes in polyvinyl toluene scintillators

Polyvinyl toluene (PVT) based detectors are used in radiation portal monitors (RPMs) worldwide to detect the trafficking of illicit nuclear material. PVT scintillators, which are normally optically clear, have been observed to suffer internal fogging throughout their volume due to prolonged exposure to varying environmental conditions. These changes could lead to reduced performance for RPMs that utilize plastic scintillators. In this research, a proof of concept system, consisting of different color light emitting diodes (LEDs) and a single optical sensor (OS), were used to examine the change in light transmission through a PVT scintillator. This Optical Monitoring System (OMS), coupled with an environmentally exposed PVT detector, was tested in an environmental chamber where it was subjected to changes in temperature and humidity ranging from 55 °C at 100% relative humidity to –20 °C at 40% relative humidity. At temperatures below 10 °C, light transmission was reduced by 81% ± 8% for blue LEDs, 84% ± 5% for yellow LEDs, and 49% ± 4% for green LEDs. Similar reductions in detected light were not recorded when the OMS was tested with only air between the LEDs and OS. Therefore, the significant reductions in transmitted light were attributed to changes occurring within the PVT scintillator. These results indicate that a significant reduction in PVT opacity occurs due to wide environmental changes. A device such as the OMS could be used to track these changes and provide users an early indication that a portal monitor is suffering from reduced performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Accretion disk dynamics, photoionized plasmas, and stellar opacities

We present a brief review on the atomic kinetics, modeling and interpretation of astrophysical observations, and laboratory astrophysics experiments. The emphasis is on benchmarking of opacity calculations relevant for solar structure models, photoionized plasmas research, the magnetohydrodynamic numerical simulation of accretion disk dynamics, and a connection between radiation transport effects and plasma source geometry details. Specific cases of application are discussed with relevance to recent and proposed laboratory astrophysics experiments as well as Chandra and X-ray Multi-Mirror Mission Newton observations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Initial experimental demonstration of the principles of a xenon gas shield designed to protect optical components from soft x-ray induced opacity (blanking) in high energy density experiments

The design principles of a xenon gas shield device that is intended to protect optical components from x-ray induced opacity (“x-ray blanking”) have been experimentally demonstrated at the OMEGA-60 Laser Facility at the Laboratory for Laser Energetics, University of Rochester. A volume of xenon gas placed in front of an optical component absorbs the incoming soft x-ray radiation but transmits optical and ultra-violet radiation. The time-resolved optical (532 nm) transmission of samples was recorded as they were exposed to soft x-rays produced by a gold sphere source (1.5 kJ sr $-$1 , 250–300 eV). Blanking of fused silica (SiO 2 ) was measured to occur over a range of time-integrated soft x-ray (<3 keV) fluence from ~0.2–2.5 J cm $-$2 . A shield test device consisting of a 30 nm silicon nitride (Si 3 N 4 ) and a 10 cm long volume of 0.04 bar xenon gas succeeded in delaying loss of transmission through a magnesium fluoride sample; optical transmission was observed over a longer period than for the unprotected sample. It is hoped that the design of this x-ray shield can be scaled in order to produce a shield device for the National Ignition Facility optical Thomson scattering collection telescope, in order to allow measurements of hohlraum plasma conditions produced in inertial confinement fusion experiments. Finally, if successful, it will also have applications in many other high energy density experiments where optical and ultra-violet measurements are desirable.

42 ENGINEERING↗

Towards a novel stellar opacity measurement scheme using stability properties of double ablation front structures

A novel method for bringing sample elements to hydrodynamic conditions relevant to the base of the solar convection zone is investigated. The method is designed in the framework of opacity measurements and exploits the temporal and spatial stability of hydrodynamic parameters in counter-propagating Double Ablation Front (DAF) structures. The physics of symmetric DAF structures is first studied in 1D geometries to assess the influence of tracer layers in the target. These results are used to propose an experimental design compatible with the OMEGA [Boehly et al., Opt. Commun. 133(1-6), 495–506 (1997)] laser. Radiative-hydrodynamic simulations conducted using the Chic code [Breil et al., Comput. Fluids 46, 161–167 (2011).] in 2D-axisymmetric geometries suggest that a Fe sample can be brought to an electron temperature of ∼160 eV and electron number density of ∼1.35 × 1023 cm−3. These parameters are reached during a 500 ps window with temporal variations of the order of 10 eV and 1022 cm−3, respectively. This allows for potential time-integrated spectral measurements. During that time, the sample is almost at local thermal equilibrium and 2D spatial gradients in the sample are less than 5% in a 360 μm diameter cylindrical volume, including the potential effects of Hot Electrons (HE) and typical uncertainties related to target fabrication and laser performances. The effects of HEs are assessed using an inline model in Chic. The HEs are found to deposit most of their energy in the cold and dense ablator between the two fronts, leading to a small efficiency loss on the DAF parameters. The calculations also suggest that negligible amounts of unabsorbed HEs are present in the probed volume, thus not affecting the atomic properties of the sample. Potential extensions of the current design to higher sample temperatures within the OMEGA capabilities are briefly discussed.

Colaïtis, A.↗

Upgrades and redesign of the National Ignition Facility’s soft x-ray opacity spectrometer (OpSpec)

The soft x-ray Opacity Spectrometer (OpSpec) used on the National Ignition Facility (NIF) has recently incorporated an elliptically shaped crystal. The original OpSpec used two convex cylindrical crystals for time-integrated measurements of point-projection spectra from 540 to 2100 eV. However, with the convex geometry, the low-energy portion of the spectrum suffered from high backgrounds due to scattered x-rays as well as reflections from alternate crystal planes. An elliptically shaped crystal allows an acceptance aperture at the crossover focus between the crystal and the detector, which reduces background and eliminates nearly all reflections from alternate crystal planes. The current elliptical design is an improvement from the convex cylindrical design but has a usable energy range from 900 to 2100 eV. In addition, OpSpec is currently used on 18 NIF shots/year, in which both crystals are typically damaged beyond reuse, so efficient production of 36 crystals/year is required. Design efforts to improve the existing system focus on mounting reliability, reducing crystal strain to increase survivability between mounting and shot time, and extending the energy range of the instrument down to 520 eV. The elliptical design, results, and future options are presented.

Wallace, M. S. (ORCID:0000000310871216)↗

A comprehensive study of the radiative properties of NO—a first step toward a complete air opacity

Here, in this paper we propose a methodology to calculate the radiative properties of the diatomic molecular constituents of air, and utilize the present approach to model the radiative properties of nitrogen monoxide, NO. We also investigate the important physics involved in calculating accurate radiative quantities for air, such as the Planck and Rosseland mean opacities, and emission and absorption coefficients, as well as the couplings accounted for in rovibrational calculations. Complete active space self-consistent field multi-reference configuration interaction (CAS-MRCI) calculations were performed in order to model the NO X 2 Π, a 4 Π, b 4 Σ - , 1 2 Σ + , 2 2 Σ + , 3 2 Σ + , G 2 Σ - , B' 2 Δ, (C, B) 2 2 Π, (H', L) 3 2 Π, and 1 2 Φ adiabatic states, and calculate the respective molecular data. The γ X 2 Π - A 2 Σ + , ε X 2 Π - D 2 Σ + , β' X 2 Π - B' 2 Δ, '11 000 Å' A 2 Σ + - D 2 Σ + , 'infrared' X 2 Π - X 2 Π and X 2 Π - (C, B) 2 2 Π (δ and β) band systems are investigated in monochromatic spectra calculations, as well as the Ogawa a 4 Π - b 4 Σ - band and several other band systems. Several conclusions are drawn, such as the importance of including the Ogawa band, which has not been included in previous air radiative models or comprehensive line-list calculations, as well as the importance of performing coupled rovibrational line-list calculations in order to accurately calculate the Rosseland means. We also found that the additional band systems modeled here contribute significantly to the total Planck and Rosseland means.

74 ATOMIC AND MOLECULAR PHYSICS↗