Search NASA⌕ Search

SEARCH · Search NASA

Results for “Optical Error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Cosmology Large Angular Scale Surveyor (CLASS): 90 GHz Telescope Pointing, Beam Profile, Window Function, and Polarization Performance

The Cosmology Large Angular Scale Surveyor (CLASS) is a telescope array that observes the cosmic microwave background (CMB) over ∼75% of the sky from the Atacama Desert, Chile, at frequency bands centered near 40, 90, 150, and 220 GHz. CLASS measures the large angular scale CMB polarization to constrain the tensor-to-scalar ratio and the optical depth to last scattering. This paper presents the optical characterization of the 90 GHz telescope. Observations of the Moon establish the pointing while dedicated observations of Jupiter are used for beam calibration. The standard deviations of the pointing error in azimuth, elevation, and boresight angle are 1$^{'}_.$3, 2$^{'}_.$1, and 2$^{'}_.$0, respectively, over the first 3 yr of observations. This corresponds to a pointing uncertainty ∼7% of the beam’s full width at half-maximum (FWHM). The effective azimuthally symmetrized instrument 1D beam estimated at 90 GHz has an FWHM of 0$^°_.$620 ± 0$^°_.$003 and a solid angle of 138.7 ± 0.6(stats.) ± 1.1(sys.) μsr integrated to a radius of 4°. The corresponding beam window function drops to $b^2_ℓ$ = 0.93, 0.71, 0.14 at ℓ = 30, 100, 300, respectively. Far-sidelobes are studied using detector-centered intensity maps of the Moon and measured to be at a level of 10 −3 or below relative to the peak. The polarization angle of Tau A estimated from preliminary survey maps is 149°.6 ± 0°.2(stats.) in equatorial coordinates. The instrumental temperature-to-polarization (T → P) leakage fraction, inferred from per-detector demodulated Jupiter scan data, has a monopole component at the level of 1.7 × 10 −3 , a dipole component with an amplitude of 4.3 × 10 −3 , with no evidence of quadrupolar leakage.

79 ASTRONOMY AND ASTROPHYSICS↗

Mid- to long-wave infrared computational spectroscopy with a graphene metasurface modulator

In recent years there has been much interest concerning the development of modulators in the mid- to long-wave infrared, based on emerging materials such as graphene. These have been frequently pursued for optical communications, though also for other specialized applications such as infrared scene projectors. Here we investigate a new application for graphene modulators in the mid- to long-wave infrared. We demonstrate, for the first time, computational spectroscopy in the mid- to long-wave infrared using a graphene-based metasurface modulator. Furthermore, our metasurface device operates at low gate voltage. To demonstrate computational spectroscopy, we provide our algorithm with the measured reflection spectra of the modulator at different gate voltages. We also provide it with the measured reflected light power as a function of the gate voltage. The algorithm then estimates the input spectrum. We show that the reconstructed spectrum is in good agreement with that measured directly by a Fourier transform infrared spectrometer, with a normalized mean-absolute-error (NMAE) of 0.021.

36 MATERIALS SCIENCE↗

Design and performance of a variable gap system for thermal conductivity measurements of high temperature, corrosive, and reactive fluids

We report high-temperature fluids such as molten salts, liquid metals, and gasses are being proposed for many advanced energy systems including thermal energy storage devices, concentrating solar plants, and advanced nuclear reactor designs. However, the chemical behavior and thermophysical properties of many of these fluids have not been well characterized, which hinders the design, modeling, safety analysis, and deployment of these systems. Thermal conductivity is a property that is especially limited by existing measurement capabilities, which are subject to errors caused by convection, material interaction, radiative heat transfer, and instrument degradation. Therefore, there is a lack of standard, systematic measurement techniques for high-temperature, reactive, and corrosive fluids. In this work, the development of a variable gap thermal conductivity measurement system is detailed. The system is designed to measure the thermal conductivity of highly corrosive and reactive fluids, and survive operation between 100 °C and 800 °C. The effects of convection are minimized by limiting the thickness of the specimen to thin sizes (<0.3 mm). Corrections for radiative heat transfer were included in the working equations to consider specimens with varying optical properties. The design, construction, instrumentation, operating principles, and data analysis techniques are discussed in detail. The system was tested up to 500 °C using helium gas and molten KNO 3 -NaNO 3 to verify the measurement technique and determine the sources of error. At 300 and 400 °C KNO 3 -NaNO 3 , results showed maximum relative error of 6% when compared to results in the literature. The helium results were within 13% of those in the literature at 300 and 400 °C. Higher errors were observed at 500 °C for both fluids, and the sources of these errors are discussed.

42 ENGINEERING↗

Neutron powder diffraction, Mossbauer Spectroscopy and Optical Spectroscopy to study magnetic and nuclear lattices in Fe-based oxychlorides Ca2FeO3Cl, Sr2FeO3Cl and Sr3Fe2O5Cl2

Data for Neutron Diffraction, Mossbauer Spectoscopy and Optical Spectroscopy are contained on all three samples (Ca2FeO3Cl, Sr2FeO3Cl, and Sr3Fe2O5Cl2). Mossbauer data are in the folder "MossbauerSpectroscopy". This contains details of files and examples to read the data. The Optical Spectroscopy are in the folder "AbsorptionData", this contains one file with explanatory headers. The neutron diffraction data are in the "NeutronDiffractionData" folder. The data was collected on the HB-2A powder diffractometer at HFIR. The autoreduced files are corrected using a vanadium standard and are in arbitrary intensity units. The RawData folder contains the uncorrected data with metadata for motor positions and temperature. All measurements were collected with a constant neuton wavelength of 2.41 Angstrom. An excel spreadsheet "NeutronDiffractionData_IPTS-29118_summary" contains details for each scan. Sr3Fe2O5Cl2 data were collected at only room temperature. Ca2FeO3Cl and Sr2FeO3Cl data were collected at 4K and room temperature. The autoreduced .dat fileformat is three columns corresponding to: Two-theta, Intensity and Intensity_error.

fe-based oxychlorides↗

Enabling phase quantification of anhydrous cements via Raman imaging

The phase composition of Portland cements is typically determined using conventional techniques like X-ray Diffraction (XRD) Rietveld analysis, optical microscopy point counting, and electron microscopy. However, these techniques have several limitations that may affect their accuracy in certain sample-specific scenarios. Here, we report a highly accurate phase quantification of 11 different types of commercial, anhydrous cements using a new and complementary technique: Raman imaging. Specifically, for the 4 principal phases, composition from our extensive data (250,000 Raman spectra per sample, error < 0.71%) and those obtained from XRD Rietveld and supplier data have high coefficients of determination (R{sup 2} > 0.98, mean deviation <2%). Additionally, we also quantify 8 secondary phases present in cement clinkers (gypsum, anhydrite, bassanite, syngenite, dolomite, calcite, quartz, and portlandite) with a high degree of confidence, thereby demonstrating that Raman imaging is a highly versatile tool for anhydrous phase quantification in a broad variety of cements.

36 MATERIALS SCIENCE↗

Real-Time Automated pH Control within Batch Processes Relying on Raman pH Measurement

Nuclear fission is an energy source that can provide consistent power with very low associated carbon emissions. However, management of the used nuclear fuel is an important aspect of the application of nuclear power. Recycling of useful components from used fuel is an attractive option, but this involves chemical processing of the fuel. Possible chemical separation technologies that might be used in this regard are sensitive to solution pH. Raman spectroscopy is a promising technique for monitoring the pH of solutions in real time. Classical pH probes are too fragile to be used in the harsh environments encountered in nuclear fuel processing. Raman probes are robust and can withstand these harsh environments to track pH. Coupled with chemometric analysis, the demonstration of the use of Raman spectroscopy to track and predict the pH in carboxylate-buffered systems is made possible. Utilizing this spectroscopy in conjunction with Programmable Logic Controllers mimics industrial control systems used in many modern industrial settings. This showcases a pragmatic approach toward leveraging Raman spectroscopy and chemometric model outputs as inputs for a real-time control system. The model to predict pH created by chemometrics proved to be successful in tracking pH. The optimal pH for TALSPEAK extraction of lanthanides and actinides from aqueous solution is known to proceed in a narrow pH range of around pH = 2.8 ± 0.1. This study uses Raman optical monitoring and automated control to return and maintain solution pH within this range after acid or base perturbations move the solution pH well outside this region. Root-mean-square errors show that pH changes measured using Raman spectroscopy on the batch process solution are reliably measured and used to automatically correct and maintain solution pH. Measurement of solution pH tracks favorably with electrochemical pH probe comparison measurements. As a result, the ability to showcase Raman spectroscopy paired with chemometrics analysis acts as a durable, better alternative data source compared to traditional pH probes to optimize the separation efficiency in the used nuclear fuel processing.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

AutoEnRichness: A hybrid empirical and analytical approach for estimating the richness of galaxy clusters

ABSTRACT We introduce AutoEnRichness, a hybrid approach that combines empirical and analytical strategies to determine the richness of galaxy clusters (in the redshift range of 0.1 ≤ z ≤ 0.35) using photometry data from the Sloan Digital Sky Survey Data Release 16, where cluster richness can be used as a proxy for cluster mass. In order to reliably estimate cluster richness, it is vital that the background subtraction is as accurate as possible when distinguishing cluster and field galaxies to mitigate severe contamination. AutoEnRichness is comprised of a multistage machine learning algorithm that performs background subtraction of interloping field galaxies along the cluster line of sight and a conventional luminosity distribution fitting approach that estimates cluster richness based only on the number of galaxies within a magnitude range and search area. In this proof-of-concept study, we obtain a balanced accuracy of 83.20 per cent when distinguishing between cluster and field galaxies as well as a median absolute percentage error of 33.50 per cent between our estimated cluster richnesses and known cluster richnesses within r200. In the future, we aim for AutoEnRichness to be applied on upcoming large-scale optical surveys, such as the Legacy Survey of Space and Time and Euclid, to estimate the richness of a large sample of galaxy groups and clusters from across the halo mass function. This would advance our overall understanding of galaxy evolution within overdense environments as well as enable cosmological parameters to be further constrained.

79 ASTRONOMY AND ASTROPHYSICS↗

The Atacama Cosmology Telescope: Weighing Distant Clusters with the Most Ancient Light

We use gravitational lensing of the cosmic microwave background (CMB) to measure the mass of the most distant blindly selected sample of galaxy clusters on which a lensing measurement has been performed to date. In CMB data from the the Atacama Cosmology Telescope and the Planck satellite, we detect the stacked lensing effect from 677 near-infrared-selected galaxy clusters from the Massive and Distant Clusters of WISE Survey (MaDCoWS), which have a mean redshift of $\langle z\rangle =1.08$. There are currently no representative optical weak lensing measurements of clusters that match the distance and average mass of this sample. We detect the lensing signal with a significance of $4.2\sigma $. We model the signal with a halo model framework to find the mean mass of the population from which these clusters are drawn. Assuming that the clusters follow Navarro–Frenk–White (NFW) density profiles, we infer a mean mass of $\langle {M}_{500c}\rangle =\left(1.7\pm 0.4\right)\times {10}^{14}\,{M}_{\odot }$. We consider systematic uncertainties from cluster redshift errors, centering errors, and the shape of the NFW profile. These are all smaller than 30% of our reported uncertainty. This work highlights the potential of CMB lensing to enable cosmological constraints from the abundance of distant clusters populating ever larger volumes of the observable universe, beyond the capabilities of optical weak lensing measurements.

79 ASTRONOMY AND ASTROPHYSICS↗

Designing dynamically corrected gates robust to multiple noise sources using geometric space curves

Noise-induced gate errors remain one of the main obstacles to realizing a broad range of quantum information technologies. Dynamical error suppression using carefully designed control schemes is critical for overcoming this challenge. Such schemes must be able to correct against multiple noise sources simultaneously afflicting a qubit to reach error-correction thresholds. Here we present a general framework for designing control fields that simultaneously suppress both noise in the fields themselves as well as transverse dephasing noise. Using the recently developed space curve quantum control formalism, in which robust quantum evolution is mapped to closed geometric curves in a multidimensional Euclidean space, we derive the minimal conditions necessary to guarantee the simultaneous cancellation of both types of noise to leading order. In particular, we find that the cancellation of control field noise requires the derivative of the space curve to have zero-area projections, which is a much more subtle property compared to the closed-curve condition needed to suppress transverse dephasing. We present several techniques for solving both these conditions simultaneously and provide explicit examples of error-resistant control fields. Finally, our work also sheds light on the relation between holonomic evolution and the suppression of control field errors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Inverse Method for Noninvasive Material Discrimination with Multienergy X-Ray Radiography

Active x-ray inspections have great potential for noninvasive detection of illicit materials. Dual-energy x-ray radiography, in particular, has been used to determine material composition by utilizing the energy-dependence of the x-ray attenuation coefficients. However, current implementations of this method are limited in their ability to determine the material composition of composite objects. Here, in this paper, we present an inverse algorithm that uses multienergy x-ray radiography data to noninvasively reconstruct the contents of a container. A critical feature of the current contribution is that material identification can be performed using conventional detectors and x-ray spectra with different endpoint energies produced by varying nothing more than the tube voltage. Adaptive regularization is used to increase the accuracy of material estimations from multienergy data sets. The utility of these methods is demonstrated with experimentally acquired radiographs obtained using a tunable x-ray source that produces spectra with endpoint energies of 100–450 keV. The object inspected is a scale model of a nuclear materials storage container composed of three-dimensional printed plastic and stainless-steel spheres inside a thin-walled steel container. Reconstructions of the steel sphere thicknesses are within a root-mean-square error of 0.37 cm.

47 OTHER INSTRUMENTATION↗

Classical Simulation of Boson Sampling Based on Graph Structure

Boson sampling is a fundamentally and practically important task that can be used to demonstrate quantum supremacy using noisy intermediate-scale quantum devices. In this Letter, we present classical sampling algorithms for single-photon and Gaussian input states that take advantage of a graph structure of a linear-optical circuit. The algorithms’ complexity grows as so-called treewidth, which is closely related to the connectivity of a given linear-optical circuit. Using the algorithms, we study approximated simulations for local Haar-random linear-optical circuits. For equally spaced initial sources, we show that, when the circuit depth is less than the quadratic in the lattice spacing, the efficient simulation is possible with an exponentially small error. Notably, right after this depth, photons start to interfere each other and the algorithms’ complexity becomes subexponential in the number of sources, implying that there is a sharp transition of its complexity. Finally, when a circuit is sufficiently deep enough for photons to typically propagate to all modes, the complexity becomes exponential as generic sampling algorithms. We numerically implement a likelihood test with a recent Gaussian boson sampling experiment and show that the treewidth-based algorithm with a limited treewidth renders a larger likelihood than the experimental data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Beta Radiation Hardness of GYGAG(Ce) Transparent Ceramic Scintillators

GYGAG(Ce) transparent ceramic garnet scintillators were irradiated with electrons from 0.5 to 2 MeV with fluences from 10 16 e – /cm 2 to 10 19 e – /cm 2 , corresponding to doses from 0.3 to 310 Gigarad. Absorption spectra were measured before and after irradiations. Light yields from alpha, beta, and gamma excitations were measured before and after irradiation and compared to preirradiation values to gain a deeper understanding of how electron irradiations can affect light yield, as well as defects generated in both the surface and bulk. Within experimental error, no degradation in light yield was observed for the electron-irradiated samples, as measured via beta or gamma excitation, with minimal degradation observed via alpha excitation. A small increase in optical absorption near the wavelength of emission was observed following the largest dose irradiation. These results suggest that GYGAG(Ce) is radiation hard to electron irradiation up to 10 19 e – /cm 2 and doses up to 310 Gigarad. Furthermore, this robustness to irradiation indicates that transparent ceramic garnets may prove useful for applications such as scintillation-based nuclear batteries by allowing for higher energy beta emitters, increased power densities, and enabling long service lifetimes.

36 MATERIALS SCIENCE↗

Adaptive optical correction for in vivo two-photon fluorescence microscopy with neural fields

Adaptive optics restore ideal imaging performance in complex samples by measuring and correcting optical aberrations but often require custom-built microscopes with carefully aligned wavefront sensing/shaping devices and can be susceptible to sample motion. Here we describe NeAT, a computational framework using neural fields for adaptive optics two-photon fluorescence microscopy. NeAT estimates wavefront aberration and recovers sample structure from a 3D image stack without requiring external datasets for training. Incorporating motion correction in learning and correcting conjugation errors commonly found in commercial microscopes, NeAT is designed for deployment in biological laboratories for in vivo imaging. We validate NeAT’s performance using a custom-built microscope with a wavefront sensor under varying signal-to-noise ratios, aberration and motion conditions. With a commercial microscope, we demonstrate real-time aberration correction for in vivo morphological and functional imaging in the living mouse brain, with NeAT improving the signal and accuracy of glutamate and calcium imaging of synapses and neurons.

Kang, Iksung↗

Radiation transfer in the spectra of short-pulse laser-heated targets

The conditions in laser-produced plasmas are frequently determined with x-ray spectroscopy by comparing calculated to measured spectra. Line spectra from K-shell transitions of low- to mid-atomic number elements are most often used since the important physical processes are well understood and reliable spectra can be readily measured and calculated. Radiation transfer effects due to large optical depths of strong lines can influence the spectra. In this work, the effects of radiation transfer on the emission spectra of short-laser pulse-heated targets are studied. The possible errors made in inferring electron temperature by not including radiation transfer are quantified. The inclusion of radiative transfer in spectral calculations improves the accuracy of typical temperature diagnostics and allows the use of strong lines for diagnostics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Spectral-density estimation with the Gaussian integral transform

The spectral-density operator $\hat{ρ}(ω) = δ(ω–\hat{H})$ plays a central role in linear response theory as its expectation value, the dynamical response function, can be used to compute scattering cross sections. In this work, we describe a near optimal quantum algorithm providing an approximation to the spectral density with energy resolution $\Delta$ and error $\epsilon$ using $O(\sqrt{\text{log}_2 (1/ε)[\text{log}_2 (1 / Δ) + \text{log}_2 (1/ε)]/ Δ)}$ operations. This is achieved without using expensive approximations to the time-evolution operator, but instead exploiting qubitization to implement an approximate Gaussian integral transform of the spectral density. Finally, we also describe appropriate error metrics to assess the quality of the spectral function approximations more generally.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optical second harmonic generation in anisotropic multilayers with complete multireflection of linear and nonlinear waves using ♯SHAARP.ml package

Abstract Optical second harmonic generation (SHG) is a nonlinear optical effect widely used for nonlinear optical microscopy and laser frequency conversion. Closed-form analytical solution of the nonlinear optical responses is essential for evaluating materials whose optical properties are unknown a priori. A recent open-source code, ♯SHAARP. si , can provide such closed form solutions for crystals with arbitrary symmetries, orientations, and anisotropic properties at a single interface. However, optical components are often in the form of slabs, thin films on substrates, and multilayer heterostructures with multiple reflections of both the fundamental and up to ten different SHG waves at each interface, adding significant complexity. Many approximations have therefore been employed in the existing analytical approaches, such as slowly varying approximation, weak reflection of the nonlinear polarization, transparent medium, high crystallographic symmetry, Kleinman symmetry, easy crystal orientation along a high-symmetry direction, phase matching conditions and negligible interference among nonlinear waves, which may lead to large errors in the reported material properties. To avoid these approximations, we have developed an open-source package named Second Harmonic Analysis of Anisotropic Rotational Polarimetry in Multilayers (♯SHAARP. ml ). The reliability and accuracy are established by experimentally benchmarking with both the SHG polarimetry and Maker fringes using standard and commonly used nonlinear optical materials as well as twisted 2-dimensional heterostructures.

36 MATERIALS SCIENCE↗

Calibration and Localization of Optically Pumped Magnetometers Using Electromagnetic Coils

In this paper, we propose a method to estimate the position, orientation, and gain of a magnetic field sensor using a set of (large) electromagnetic coils. We apply the method for calibrating an array of optically pumped magnetometers (OPMs) for magnetoencephalography (MEG). We first measure the magnetic fields of the coils at multiple known positions using a well-calibrated triaxial magnetometer, and model these discreetly sampled fields using vector spherical harmonics (VSH) functions. We then localize and calibrate an OPM by minimizing the sum of squared errors between the model signals and the OPM responses to the coil fields. We show that by using homogeneous and first-order gradient fields, the OPM sensor parameters (gain, position, and orientation) can be obtained from a set of linear equations with pseudo-inverses of two matrices. The currents that should be applied to the coils for approximating these low-order field components can be determined based on the VSH models. Computationally simple initial estimates of the OPM sensor parameters follow. As a first test of the method, we placed a fluxgate magnetometer at multiple positions and estimated the RMS position, orientation, and gain errors of the method to be 1.0 mm, 0.2°, and 0.8%, respectively. Lastly, we calibrated a 48-channel OPM array. The accuracy of the OPM calibration was tested by using the OPM array to localize magnetic dipoles in a phantom, which resulted in an average dipole position error of 3.3 mm. The results demonstrate the feasibility of using electromagnetic coils to calibrate and localize OPMs for MEG.

47 OTHER INSTRUMENTATION↗

Using machine learning with optical profilometry for GaN wafer screening

Abstract To improve the manufacturing process of GaN wafers, inexpensive wafer screening techniques are required to both provide feedback to the manufacturing process and prevent fabrication on low quality or defective wafers, thus reducing costs resulting from wasted processing effort. Many of the wafer scale characterization techniques—including optical profilometry—produce difficult to interpret results, while models using classical programming techniques require laborious translation of the human-generated data interpretation methodology. Alternatively, machine learning techniques are effective at producing such models if sufficient data is available. For this research project, we fabricated over 6000 vertical PiN GaN diodes across 10 wafers. Using low resolution wafer scale optical profilometry data taken before fabrication, we successfully trained four different machine learning models. All models predict device pass and fail with 70–75% accuracy, and the wafer yield can be predicted within 15% error on the majority of wafers.

36 MATERIALS SCIENCE↗