The persistence of memory in ionic conduction probed by nonlinear optics

Predicting practical rates of transport in condensed phases enables the rational design of materials, devices and processes. This is especially critical to developing low-carbon energy technologies such as rechargeable batteries. For ionic conduction, the collective mechanisms, variation of conductivity with timescales and confinement, and ambiguity in the phononic origin of translation, call for a direct probe of the fundamental steps of ionic diffusion: ion hops. However, such hops are rare-event large-amplitude translations, and are challenging to excite and detect. Here we use single-cycle terahertz pumps to impulsively trigger ionic hopping in battery solid electrolytes. This is visualized by an induced transient birefringence, enabling direct probing of anisotropy in ionic hopping on the picosecond timescale. The relaxation of the transient signal measures the decay of orientational memory, and the production of entropy in diffusion. We extend experimental results using in silico transient birefringence to identify vibrational attempt frequencies for ion hopping. Using nonlinear optical methods, we probe ion transport at its fastest limit, distinguish correlated conduction mechanisms from a true random walk at the atomic scale, and demonstrate the connection between activated transport and the thermodynamics of information.

25 ENERGY STORAGE↗

Magnetic field measurements from the solar probe

An optical system for the solar probe is described as well as its capability for improvements in spatial resolution. A magnetograph for measuring the elementary flux tube and obtaining vector geometry field geometry offers the possibility of looking for low contrast weak structure. With the probe's orbit passing over the pole, the structure of the polar field can be directly measured. The detector plane of the system receives a telecentric image of the objective. Because there is an aperture in this focal plane that can both move and change size, polarized line profiles can be obtained at arbitrary points with variable spatial resolution. The telescope microprocessor searches for the magnetic elements and then constructs the vector field.

Title, A. M.↗

Pioneer-Venus large probe infrared radiometer /LIR/ optical system

The LIR (large probe infrared radiometer) instrument has been developed for the NASA Ames Research Center for use in the 1978 Venus Atmospheric Probe Mission. The mission objectives are to determine the nature and composition of the clouds, the composition and structure of the atmosphere, and the atmospheric circulation pattern of the planet Venus. The LIR is a six-channel (3-50 micron) internally calibrated radiometer which measures the radiance difference at plus or minus 45 deg to the horizontal as viewed through a single diamond window in the spacecraft. The LIR optical system consists of a unique arrangement of hollow light pipes which optically couple a six element detector/filter array to the spacecraft window while mechanically and thermally isolating the array from the window's harsh thermal environment. A single rotating section with a 45 deg bend and containing a collimator alternately views up and down through director/extender pipes located adjacent to the diamond window. Light is transferred from the rotating section to a fixed section containing a diamond diffuser to scramble the light. This minimizes asymmetries and improves channel field of view overlap.

Brown, F. G.↗

Interactions between Surface Chemistry and Gas-Phase Combustion: New Optical Tools for Probing Flame-Wall Interactions and the Heterogeneous Chemistry of Soot Growth and Oxidation in Flame. Final report

Some of the most stubborn and technologically critical problems in combustion are dominated by heterogeneous processes. While purely gas-phase combustion systems have been the subject of intense theoretical and experimental study, combustion phenomena occurring at interfaces are far less understood. This is partly caused by the lack of experimental approaches capable of probing locations very close to an interface, especially in the hostile environment of combustion. For laser-based optical techniques, measurements taken near interfaces are often complicated by laser scattering from the surface interfering with relatively weak signals. Further, for measurements intended to probe molecular species adsorbed at the interface between a gas-phase combustion reaction and a condensed phase material, signals are generally overwhelmed by contributions from the bulk phases, causing the small contribution from the interfacial molecular species to be undetectable. Our goal in this project has been to develop new optical tools for imaging chemical species, temperature, and surface species at and near surfaces or interfaces of relevance to combustion. We have placed focus on the development and refinement of ultrafast techniques such as femtosecond coherent Raman imaging and femtosecond/picosecond sum-frequency generation (SFG) scattering, as well as the models used to simulate such spectra under differing conditions of pressure and chemical speciation. The two physical phenomena initially targeted for study in this project were flamewall interactions, and the growth of particulates in flames.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optical Absorption Spectroscopy Probes Water Wire and Its Ordering in a Hydrogen-Bond Network

Water wires, quasi-one-dimensional chains composed of hydrogen-bonded (H-bonded) water molecules, play a fundamental role in numerous chemical, physical, and physiological processes. Yet direct experimental detection of water wires has been elusive so far. Based on advanced many-body theory that includes electron-hole interactions, we report that optical absorption spectroscopy can serve as a sensitive probe of water wires and their ordering. In both liquid and solid water, the main peak of the spectrum is discovered to be a charge-transfer exciton. In water, the charge-transfer exciton is strongly coupled to the H-bonding environment where the exciton is excited between H-bonded water molecules with a large spectral intensity. In regular ice, the spectral weight of the charge-transfer exciton is enhanced by a collective excitation occurring on proton-ordered water wires, whose spectral intensity scales with the ordering length of water wire. The spectral intensity and excitonic interaction strength reaches its maximum in ice XI, where the long-range ordering length yields the most pronounced spectral signal. Our findings suggest that water wires, which widely exist in important physiological and biological systems and other phases of ice, can be directly probed by this approach. Published by the American Physical Society 2025

Tang, Fujie (ORCID:0000000197615359)↗

Excitation-dependent carrier lifetime and diffusion length in bulk CdTe determined by time-resolved optical pump-probe techniques

We applied time-resolved pump-probe spectroscopy based on free carrier absorption and light diffraction on a transient grating for direct measurements of the carrier lifetime and diffusion coefficient D in high-resistivity single crystal CdTe (codoped with In and Er). The bulk carrier lifetime t decreased from 670 +/-50 ns to 60 +/- 10 ns with increase of excess carrier density N from 10 16 to 5 x 10 18 cm -3 due to the excitation-dependent radiative recombination rate. In this N range, the carrier diffusion length dropped from 14 um to 6 um due to lifetime decrease. Modeling of in-depth (axial) and in-plane (lateral) carrier diffusion provided the value of surface recombination velocity S = 6 x 10 5 cm/s for the untreated surface. At even higher excitations, in the 10 19 -3 x 10 20 cm -3 density range, D increase from 5 to 20 cm^2/s due to carrier degeneracy was observed.

14 SOLAR ENERGY↗

Multimode-Optical-Fiber Imaging Probe

Currently, endoscopic surgery uses single-mode fiber-bundles to obtain in vivo image information inside the orifices of the body. This limits their use to the larger natural orifices and to surgical procedures where there is plenty of room for manipulation. The knee joint, for example, can be easily viewed with a fiber optic viewer, but joints in the finger cannot. However, there are a host of smaller orifices where fiber endoscopy would play an important role if a cost effective fiber probe were developed with small enough dimensions (less than or equal to 250 microns). Examples of beneficiaries of micro-endoscopes are the treatment of the Eustatian tube of the middle ear, the breast ducts, tear ducts, coronary arteries, fallopian tubes, as well as the treatment of salivary duct parotid disease, and the neuro endoscopy of the ventricles and spinal canal. This work describes an approach for recovering images from tightly confined spaces using multimode. The concept draws upon earlier works that concentrated on image recovery after two-way transmission through a multimode fiber as well as work that demonstrated the recovery of images after one-way transmission through a multimode fiber. Both relied on generating a phase conjugated wavefront, which was predistorted with the characteristics of the fiber. The approach described here also relies on generating a phase conjugated wavefront, but utilizes two fibers to capture the image at some intermediate point (accessible by the fibers, but which is otherwise visually inaccessible).

Jackson, Deborah↗

Multimode-Optical-Fiber Imaging Probe

Currently, endoscopic surgery uses single-mode fiber-bundles to obtain in vivo image information inside orifices of the body. This limits their use to the larger natural bodily orifices and to surgical procedures where there is plenty of room for manipulation. The knee joint, for example can be easily viewed with a fiber optic viewer, but joints in the finger cannot. However, there are a host of smaller orifices where fiber endoscopy would play an important role if a cost effective fiber probe were developed with small enough dimensions (< 250 microns). Examples of beneficiaries of micro-endoscopes are the treatment of the Eustatian tube of the middle ear, the breast ducts, tear ducts, coronary arteries, fallopian tubes, as well as the treatment of salivary duct parotid disease, and the neuro endoscopy of the ventricles and spinal canal. To solve this problem, this work describes an approach for recovering images from. tightly confined spaces using multimode fibers and analytically demonstrates that the concept is sound. The proof of concept draws upon earlier works that concentrated on image recovery after two-way transmission through a multimode fiber as well as work that demonstrated the recovery of images after one-way transmission through a multimode fiber. Both relied on generating a phase conjugated wavefront which was predistorted with the characteristics of the fiber. The described approach also relies on generating a phase conjugated wavefront, but utilizes two fibers to capture the image at some intermediate point (accessible by the fibers, but which is otherwise visually unaccessible).

Jackson, Deborah↗

Coumarin-Rhodamine Hybrids—Novel Probes for the Optical Measurement of Viscosity and Polarity

A comprehensive systematic study of absorption and fluorescence properties in solvents of varying viscosity and polarity of three novel and red-emitting coumarin-rhodamine hybrid derivatives with differences in the rigidity of their substituents is presented. This includes ethanol-polyethylene glycol, toluene-polyethylene glycol, and toluene-paraffin mixtures. Moreover, protonation-induced effects on the spectroscopic properties are studied. A viscosity-induced emission enhancement was observed for all coumarin-rhodamine hybrid derivatives. MCR2 bearing a julolidine donor showed the expected low sensitivity to viscosity whereas MCR3 with its freely rotatable diphenylamino substituent revealed a particularly pronounced sensitivity to this parameter. Moreover, MCR2 shows an enhancement in emission in the open, i.e., protonated form in conjunction with a largely Stokes shift fluorescence in the deep red spectral region. This enables the application of these dyes as viscosity sensors and as far red emitting pH-sensitive probes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Time resolved electrical, optical, and thermal probes of topological spin textures in magnetic nanostructures

This project is a fundamental study of magnetization dynamics in nanoscale spin textures with topological properties. One example is magnetic skyrmions that form in chiral ferromagnetic material systems that lack inversion symmetry. We have concentrated on the scalable chiral magnetic metal B20 FeGe thin film that has an asymmetric exchange interaction due to non-centrosymmetric cubic lattice. While the asymmetric exchange interaction can be found at the interface of a ferromagnet and a heavy metal, manipulation of skyrmions at these interfaces is non-trivial due to pinning and it requires higher critical current. In contrast, B20 materials such as FeGe have superior material quality to offer pinning-free and low-current skyrmion motion.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Remote probing of the optical strength of atmospheric turbulence and of wind velocity

A procedure for determining the optical strength of turbulence of the atmosphere and the wind velocity at various altitudes by measuring the spatial and temporal covariance of scintillation is developed. Emphasis is placed on the development of the formal relationships that have to be inverted to obtain the desired results. For determination of optical strength of turbulence, it is a linear integral equation that is developed. However, for determination of remote wind velocity, a nonlinear integral equation is obtained. A computer approach for solving each of the equations is suggested. The configuration and performance requirements of the measurement apparatus are discussed.

Fried, D. L.↗

Operating envelopes of particle sizing instrumentation used for icing research

The Forward Scattering Spectrometer Probe and the Optical Array Probe are analyzed in terms of their ability to make accurate determinations of water droplet size distributions. Sources of counting and sizing errors are explained. The paper describes ways of identifying these errors and how they can affect measurement.

Hovenac, Edward A.↗

Operating envelopes of particle sizing instrumentation used for icing research

The Forward Scattering Spectrometer Probe and the Optical Array Probe are analyzed in terms of their ability to make accurate determinations of water droplet size distributions. Sources of counting and sizing errors are explained. The paper describes ways of identifying these errors and how they can affect measurement.