Search NASA⌕ Search

SEARCH · Search NASA

Results for “Ozone Mapping”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Interannual Variabilities in Tropical Tropospheric Ozone

This paper presents the first detailed characterization of interannual variability in tropical tropospheric column ozone (TCO) to delineate the relative importance of biomass burning and large-scale transport. TCO time series are derived from 20 years (1979-1998) of total ozone mapping spectrometer (TOMS) data using the convective cloud differential (CCD) method. Our study identifies three regions in the tropics with distinctly different characteristics related to interannual variability. These three regions are the eastern Pacific, Atlantic, and western Pacific. The Atlantic region indicates a quasi-biennial oscillation (QBO) in TCO which is out of phase with the QBO in stratospheric ozone. This is consistent with the photochemical control of this region by ozone-producing precursors. The observed pattern however does not seem to be related to interannual variability in ozone precursors related to biomass burning. Instead it appears to be a manifestation of the UV modulation of upper tropospheric chemistry on a QBO time scale caused by stratospheric ozone. During El Nino events there is anomalously low TCO in the eastern Pacific and high values in the western Pacific, indicating the effects of convectively-driven transport. The observed increase of 10-20 DU in TCO in the Indonesian region in the western Pacific during the recent 1997-1998 El Nino was associated with large-scale fires which may have contributed 5-10 DU of the total increase.

Ziemke, Jerry R.↗

Coherent variations of monthly mean total ozone and lower stratospheric temperature

Space-time patterns of correlation between total ozone and lower stratospheric temperature are documented, based on 14 years (1979-1992) of global monthly mean observations. Data are obtained from the total ozone mapping spectrometer (TOMS) and microwave sounding unit (MSU) channel 4, the latter being a weighted mean temperature of the 150- to 50-mbar layer. These data are analyzed (separately) for linear trend, solar cycle, quasi-biennial oscillation (QBO), and El Nino-Southern Oscillation (ENSO) variations via linear regression: significant signals are identified for each term, and the corresponding structures in ozone and temperature are found to be highly coherent. The temperature trends derived here show significant cooling of the lower stratosphere over Northern Hemisphere (NH) midlatitudes in winter-spring and over Antarctica in Southern Hemisphere (SH) spring; the overall space-time patterns are similar to those determined for ozone trends. Interestingly, temperatures do not decrease over SH midlatitudes during midwinter, in spite of large ozone losses. These data furthermore show globally coherent ozone and temperature perturbations associated with both QBO and ENSO variations; a new result here show large total ozone anomalies in middle-to-high latitudes of both hemispheres associated with ENSO events. Residuals from the ozone and temperature time series (defined as the deseasonalized total minus the regression fits) show strong positive correlation in middle-to-high latitudes but weak correlations in the trop ics. Time periods following the volcanic eruptions of El Chichon and Pinatubo are clearly identified from the coupled signatures of decreased ozone and increased temperature, opposite to the positive ozone-temperature correlations observed at other times. The ratios of ozone to temperature anomalies derived here show quantitative signatures indicating that either radiative (trend, solar, and QBO) or dynamical (ENSO and residuals) processes are responsible for the strong ozone-temperature correlations.

Randel, William J.↗

Estimation of 3-D Cloud Effects on TOMS Satellite Retrieval of Surface UV Irradiance

To improve surface UV irradiance retrieval from the Total Ozone Mapping Spectrometer (TOMS) we simulate errors of the TOMS cloud correction algorithm for summertime broken cloud conditions. Cloud scenes (50 km by 50 km) are modeled by a normal random (Gaussian) field with a fixed lower boundary and conservative scattering. The model relates stochastic field characteristics with the cloud amount, mean cloud diameter and aspect ratio. Clouds are embedded into Rayleigh atmosphere with standard ozone profile. Radiative transfer calculations of the radiance at the top of the atmosphere and irradiance at the surface were performed using 3-D Monte Carlo (MC) code. The results are averaged over the satellite field of view on the surface (50 km by 50 km) and compared with TOMS predicted surface irradiance for the same scene reflectance. The TOMS algorithm assumes horizontally homogeneous Cl-type cloud between 3 km and 5.5 km. The effective optical depth is determined by fitting observed (MC) radiance at 380 nm. Having the same radiance at the satellite the homogeneous and broken cloud models predict different average irradiances at the surface. This is due to the differences in Bidirectional Reflection Distribution Function (BRDF) for homogeneous and broken cloud scenes with the same hemispherical albedo. For typical TOMS observational geometry at mid-latitudes the simulated single pixels errors may be as large as +/- 20%. Qualitatively these errors are due to the dominance of the non-horizontal cloud surfaces, which are not accounted for in the homogeneous cloud model. However, due to high variability of the real cloud shapes and types it is unclear how these single pixel errors would affect TOMS time-integrated UV exposure over extended periods (weeks to months) for different regions.

Krotkov, Nickolay A.↗

Estimating Uncertainty in Long Term Total Ozone Records from Multiple Sources

Total ozone measurements derived from the TOMS and SBUV backscattered solar UV instrument series cover the period from late 1978 to the present. As the SBUV series of instruments comes to an end, we look to the 10 years of data from the AURA Ozone Monitoring Instrument (OMI) and two years of data from the Ozone Mapping Profiler Suite (OMPS) on board the Suomi National Polar-orbiting Partnership satellite to continue the record. When combining these records to construct a single long-term data set for analysis we must estimate the uncertainty in the record resulting from potential biases and drifts in the individual measurement records. In this study we present a Monte Carlo analysis used to estimate uncertainties in the Merged Ozone Dataset (MOD), constructed from the Version 8.6 SBUV2 series of instruments. We extend this analysis to incorporate OMI and OMPS total ozone data into the record and investigate the impact of multiple overlapping measurements on the estimated error. We also present an updated column ozone trend analysis and compare the size of statistical error (error from variability not explained by our linear regression model) to that from instrument uncertainty.

TOMS and SBUV↗

Ozone profile measurements at McMurdo Station Antarctica during the spring of 1987

During the Antarctic spring of 1986, 33 ozone soundings were conducted from McMurdo Station. These data indicated that the springtime decrease in ozone occurred rapidly between the altitudes of 12 and 20 km. During 1987, these measurements were repeated with 50 soundings between 29 August and 9 November. Digital conversions of standard electrochemical cell ozonesondes were again employed. The ozonesonde pumps were individually calibrated for flow rate as the high altitude performance of these pumps have been in question. While these uncertainties are not large in the region of the ozone hole, they are significant at high altitude and apparently resulted in an underestimate of total ozone of about 7 percent (average) as compared to the Total Ozone Mapping Spectrometer (TOMS) in 1986, when the flow rate recommended by the manufacturer was used. At the upper altitudes (approx. 30 km) the flow rate may be overestimated by as much as 15 percent using recommended values (see Harder et al., The UW Digital Ozonesonde: Characteristics and Flow Rate Calibration, poster paper, this workshop). These upper level values are used in the extrapolation, at constant mixing ratio, required to complete the sounding for total ozone. The first sounding was on 29 August, prior to major ozone depletion, when 274 DU total ozone (25 DU extrapolated) was observed. By early October total ozone had decreased to the 150 DU range; it then increased during mid-October owing to motion of the vortex and returned to a value of 148 DU (29 DU extrapolated) on 27 October.

Hofmann, D. J.↗

Tropospheric Ozone Retrieval By A Combination of TROPOMI/S5P Measurements With BASCOE Assimilated Data

We present a new tropospheric ozone dataset based on TROPOspheric Monitoring Instrument (TROPOMI)/Sentinel-5 Precursor (S5P) total ozone measurements combined with stratospheric ozone data from the Belgian Assimilation System for Chemical ObsErvations (BASCOE) constrained by assimilating ozone observations from the Microwave Limb Sounder (MLS). The BASCOE stratospheric data are interpolated to the S5P observations and subtracted from the TROPOMI total ozone data. The difference is equal to the tropospheric ozone residual column from the surface up to the tropopause. The tropospheric ozone columns are retrieved at the full spatial resolution of the TROPOMI sensor (5.5×3.5 km 2 ) with daily global coverage. Compared to the Ozone Mapping and Profiler Suite Modern-Era Retrospective analysis for Research and Applications 2 (OMPS-MERRA-2) data, a global mean positive bias of 3.3 DU is found for the analysed period April 2018 to June 2020. A small negative bias of about −0.91 DU is observed in the tropics relative to the operational TROPOMI tropical tropospheric data based on the convective cloud differential (CCD) algorithm throughout the same period. The new tropospheric ozone data (S5P-BASCOE) are compared to a set of globally distributed ozonesonde data integrated up to the tropopause level. We found 2254 comparisons with cloud-free TROPOMI observations within 25 km of the stations. In the global mean, S5P-BASCOE deviates by 2.6 DU from the integrated ozonesondes. Depending on the latitude the S5P-BASCOE deviate from the sondes and between −4.8 and 7.9 DU, indicating a good agreement. However, some exceptional larger positive deviations up to 12 DU are found, especially in the northern polar regions (north of 70∘). The monthly mean tropospheric column and time series for selected areas showed the expected spatial and temporal pattern, such as the wave one structure in the tropics or the seasonal cycle, including a summer maximum, in the mid-latitudes.

Satellite Retrieval↗

Ground-based intercomparisons of SBUV/2 flight instruments the world standard Dobson spectrophotometer 83 and overpass observations from Nimbus-7 TOMS and NOAA-11 SBUV/2

Total ozone data obtained during summers at Mauna Loa Observatory, Hawaii, with Dobson Spectrophotometer 83 are routinely compared with overpass total ozone data from the Total Ozone Mapping Spectrometer (TOMS) and the Solar Backscatter Ultraviolet (SBUV) spectrometer launched aboard the Nimbus 7 satellite in 1978. Results from the TOMS/Dobson instrument comparisons through 1990 have been presented by McPeters and Komhyr (1991). Dobson spectrophotometer 83 was established as the standard instrument for the U.S.A. Dobson instrument station network in 1962. In 1980, the instrument was designated by the World Meteorological Organization (WMO) as the Standard Dobson Spectrophotometer for the World. Long-term ozone measurement precision of the instrument has been maintained at plus or minus 0.5 percent (Komhyr et al., 1989). On an absolute scale, the ozone measurement accuracy of the instrument is estimated to plus or minus 3 percent. In early April, 1990, comparison of total ozone and vertical distribution (Umkehr) observations were made for the first time with Dobson spectrophotometer 8.3. The work was conducted at the NOAA Climate Monitoring and Diagnostics Laboratory (CMDL) in Boulder, Colorado, and at the research and instrument manufacturing facility of the Ball Aerospace System Division located about 2 km east of Boulder. (The SBUV-2 S/N-2 instrument, built by Ball Aerospace Systems Division, is scheduled for launch aboard the NOAA-13 satellite). We present results of the comparisons which include ozone vertical distribution data obtained with a balloon-borne electrochemical concentration cell (ECC) ozonesonde (Komhyr, 1969).

Heath, D. F.↗

OMPS Limb Profiler Instrument Performance Assessment

Following the successful launch of the Ozone Mapping and Profiler Suite (OMPS) aboard the Suomi National Polar-orbiting Partnership (SNPP) spacecraft, the NASA OMPS Limb team began an evaluation of instrument and data product performance. The focus of this paper is the instrument performance in relation to the original design criteria. Performance that is closer to expectations increases the likelihood that limb scatter measurements by SNPP OMPS and successor instruments can form the basis for accurate long-term monitoring of ozone vertical profiles. The team finds that the Limb instrument operates mostly as designed and basic performance meets or exceeds the original design criteria. Internally scattered stray light and sensor pointing knowledge are two design challenges with the potential to seriously degrade performance. A thorough prelaunch characterization of stray light supports software corrections that are accurate to within 1% in radiances up to 60 km for the wavelengths used in deriving ozone. Residual stray light errors at 1000nm, which is useful in retrievals of stratospheric aerosols, currently exceed 10%. Height registration errors in the range of 1 km to 2 km have been observed that cannot be fully explained by known error sources. An unexpected thermal sensitivity of the sensor also causes wavelengths and pointing to shift each orbit in the northern hemisphere. Spectral shifts of as much as 0.5nm in the ultraviolet and 5 nm in the visible, and up to 0.3 km shifts in registered height, must be corrected in ground processing.

ozone↗

An analysis of tropopause pressure and total ozone correlations

A study of the relationship between total ozone and tropopause pressure was carried out using Total Ozone Mapping Spectrometer (TOMS) data and National Meteorological Center (NMC) global analyses. The medium scales generally show correlations greater than 0.6 throughout the middle latitudes of both hemispheres with some regions exceeding 0.8. The areas of highest correlations seem to be associated with the storm track regions of both the Northern and Southern Hemispheres. A detailed spectral analysis is performed for the medium scales on five pairs of time series of area averaged tropopause pressure and total ozone. In middle latitudes, total ozone and tropopause pressure exhibit generally similar distributions in the power spectrum. In the subtropics and tropics the power in ozone drops off more rapidly with increasing frequency than the power in tropopause pressure. Only in the Northern Hemisphere middle latitudes does one find a clear association between increased power in ozone and tropopause pressure and maxima in the coherency spectrum. Results for large scales are more complicated, showing generally positive correlations at middle latitudes.

Schubert, Siegfried D.↗

Using the World Primary Standard Dobson Spectrometer to Monitor the Stability of a Multi-Instrument Satellite Ozone Dataset

NASA is creating a long term satellite ozone time series by combining data from multiple instruments: Nimbus 7 Total Ozone Mapping Spectrometer (TOMS) (1978 - 1993), Meteor 3 TOMS (1991 - 1994), Earth Probe TOMS (1996 - present), Nimbus 7 SB-JV (1978 - 1990), NOAA-9 Solar Backscatter UV Spectrometer (SBUV/2) (1984 - 1997), NOAA-11 SBUV/2 (1989 - 1994), and NOAA-14 SBUV/2 (1995 - present). The stability of individual data sets and possible instrument-to-instrument differences are best checked by comparison with ground-based measurements. We have examined the time dependence of the calibrations of these instruments by comparing satellite derived ozone with that measured by the world primary standard Dobson spectrometer No. 83. This instrument has been maintained since 1962 as a standard for total ozone to an uncertainty of plus or minus 0.5%. Measurements of AD pair ozone made with instrument No. 83 at Mauna Loa observatory most summers since 1979 were compared with coincident TOMS and SBUV(/2) ozone measurements. The comparison shows that the various instruments were stable relative to instrument No. 83 to within about plus or minus 1%, but that there are instrument-to-instrument biases of as much as 3%. Earth Probe TOMS, for example, is 1% to 2% high relative to Nimbus 7 TOMS when the world standard instrument is used as a transfer standard. Similar results are seen when comparisons are made with an ensemble of 41 Dobson stations throughout the world, demonstrating that the ensemble as a whole is stable despite the fact that many instruments within the ensemble have clear calibration changes.

McPeters, R.D.↗

Ten Year Ozone Profile Record From Suomi NPP OMPS Limb Profiler

In this study, we evaluate a decadal ozone profile record derived from Suomi NPP Ozone Mapping and Profiler Suite (OMPS) Limb Profiler (LP). The data from OMPS LP were re-processed with the new retrieval algorithm from 2012 to present. The new reprocessing includes adjustments in both Level 1 and Level 2 algorithms. The sensor’s altitude registration, updates in radiometric calibrations, under-sampling and stray light corrections were addressed in Level 1 processing. The new retrieval algorithm (version 2.7) combines measurements from UV and VIS parts of the spectra to retrieve a single vertical ozone profile between 12.5 km (or cloud tops) and 57.5 km, unlike to previous version 2.5 where ozone profiles were retrieved independently from UV and VIS. To improve ozone retrievals in the Upper Troposphere Lower Stratosphere (UTLS) region, we implemented a new aerosol correction that assumes a gamma-function particle size distribution. In addition, ozone and nitrogen dioxide cross sections and climatologies were updated. We discuss sensitivity of the ozone retrievals to implemented changes in Level 1 and Level 2 algorithms. We focus our analysis on evaluation of the stability of the 10-year record from OMPS LP. We show results from the internal methods for characterizing the stability of the LP altitude registration and compare the LP reflectivity and ozone with the similar quantities measured by OMPS nadir sensors. Finally, we will show results from comparisons with independent satellite (MLS and SAGE III) and ozone sonde measurements.

Ozone↗

A Long Data Record (1979-2003) of Stratospheric Ozone Derived from TOMS Cloud Slicing: Comparison with SAGE and Implications for Ozone Recovery

It is generally recognized that Stratospheric Aerosols and Gas Experiment (SAGE) stratospheric ozone data have become a standard long-record reference field for comparison with other stratospheric ozone measurements. This study demonstrates that stratospheric column ozone (SCO) derived from total ozone mapping spectrometer (TOMS) Cloud Slicing may be used to supplement SAGE data as a stand-alone long- record reference field in the tropics extending to middle and high latitudes over the Pacific. Comparisons of SAGE I1 version 6.2 SCO and TOMS version 8 Cloud Slicing SCO for 1984-2003 exhibit remarkable agreement in monthly ensemble means to within 1-3 DU (1 - 1.5% of SCO) despite being independently-calibrated measurements. An important component of our study is to incorporate these column ozone measurements to investigate long-term trends for the period 1979-2003. Our study includes Solar Backscatter Ultraviolet (SBW) version 8 measurements of upper stratospheric column ozone (i.e., zero to 32 hPa column ozone) to characterize seasonal cycles and seasonal trends in this region, as well as the lower stratosphere and troposphere when combined with TOMS SCO and total column ozone. The trend analyses suggest that most ozone reduction in the atmosphere since 1979 in mid-to-high latitudes has occurred in the Lower stratosphere below approx. 25 km. The delineation of upper and lower stratospheric column ozone indicate that trends in the upper stratosphere during the latter half of the 1979-2003 period have reduced to near zero globally, while trends in the lower stratosphere have become larger by approx. 5 DU decade%om the tropics extending to mid-latitudes in both hemispheres. For TCO, the trend analyses suggest moderate increases over the 25-year time record in the extra-tropics of both hemispheres of around 4-6 DU (Northern Hemisphere) and 6-8 DU (Southern Hemisphere).

Ziemke, Jerry R.↗

Combined Characterisation of GOME and TOMS Total Ozone Using Ground-Based Observations from the NDSC

Several years of total ozone measured from space by the ERS-2 GOME, the Earth Probe Total Ozone Mapping Spectrometer (TOMS), and the ADEOS TOMS, are compared with high-quality ground-based observations associated with the Network for the Detection of Stratospheric Change (NDSC), over an extended latitude range and a variety of geophysical conditions. The comparisons with each spaceborne sensor are combined altogether for investigating their respective solar zenith angle (SZA) dependence, dispersion, and difference of sensitivity. The space- and ground-based data are found to agree within a few percent on average. However, the analysis highlights for both Global Ozone Monitoring Experiment (GOME) and TOMS several sources of discrepancies, including a dependence on the SZA at high latitudes and internal inconsistencies.

Lambert, J.-C.↗

A geostationary imaging spectrometer TOMS instrument

One design for a geostationary Total Ozone Mapping Spectrometer (TOMS) with many desirable features is an imaging spectrometer. A preliminary study makes use of a 0.25 m Czerny-Turner spectrometer with which the Earth is imaged on a charge-coupled device (CCD) in dispersed light. The wavelength is determined by a movable grating which can be set arbitrarily by ground control. The signal integration time depends on wavelength but this system allows arbitrary timing by command. Special circumstances such as a requirement to track a low-lying sulfur dioxide cloud or a need to discriminate high level ozone from total ozone at midlatitudes could be obtained by adding a particular wavelength to the normally pre-programmed time sequence. The incident solar irradiance is measured by deploying a diffuser plate in the field of view. Individual detector elements correspond to scene elements in which the several wavelengths are serially sampled and the Earth radiance is compared to the incident sunlight. Thus the problem of uncorrelated drift of multiple detectors is removed.

Krueger, Arlin J.↗

An evaluation of observations from satellites for the study and prediction of mesoscale events and cyclone events

Quantitative observational guidelines have been developed for the study and forecasting of mesoscale events and cyclone events; many of these guidelines have resulted from major meteorological field programs. Increasingly sophisticated satellite-borne instruments in low and geosynchronous orbits have provided valuable measurements of these events. The major deficiencies in the measurements taken from geosynchronous orbit today, relative to guidelines, are (1) the lack of temperature profiles and moisture profiles below clouds, and the poor vertical resolution of these profiles; (2) the insufficient combination of spatial resolution and temporal resolution and spectral intervals available in generating images (imaging); and (3) the lack of accurate precipitation mapping. Considerably more-powerful instrumentation is possible on geosynchronous satellites that can substantially reduce these deficiencies. The capability of advanced geosynchronous observations and those expected with future instrumentation in low-orbit are evaluated with respect to tropical cyclone and severe local-storm observational guidelines. A high percentage of the guidelines are expected to be fulfilled with geosynchronous measurements: (1) using microwave instruments for imaging and for obtaining temperature profiles and moisture profiles, (2) very high spectral-resolution infrared profiling, (3) very high spatial-resolution and very high temporal-resolution imaging, and (4) ozone mapping.

Shenk, William E.↗

Problems in Assessment of the UV Penetration into Natural Waters from Space-based Measurements

Satellite instruments currently provide global maps of surface UV (ultraviolet) irradiance by combining backscattered radiance data with radiative transfer models. The models are often limited by uncertainties in physical input parameters of the atmosphere and surface. Global mapping of the underwater UV irradiance creates further challenges for the models. The uncertainties in physical input parameters become more serious because of the presence of absorbing and scattering quantities caused by biological processes within the oceans. In this paper we summarize the problems encountered in the assessment of the underwater UV irradiance from space-based measurements, and propose approaches to resolve the problems. We have developed a radiative transfer scheme for computation of the UV irradiance in the atmosphere-ocean system. The scheme makes use of input parameters derived from satellite instruments such as TOMS (Total Ozone Mapping Spectrometer) and SeaWiFS (Sea-viewing Wide Field-of-view Sensor). The major problem in assessment of the surface UV irradiance is to accurately quantify the effects of clouds. Unlike the standard TOMS UV algorithm, we use the cloud fraction products available from SeaWiFS and MODIS (Moderate Resolution Imaging Spectrometer) to calculate instantaneous surface flux at the ocean surface. Daily UV doses can be calculated by assuming a model of constant cloudiness throughout the day. Both SeaWiFS and MODIS provide some estimates of seawater optical properties in the visible. To calculate the underwater UV flux the seawater optical properties must be extrapolated down to shorter wavelengths. Currently, the problem of accurate extrapolation of visible data down to the UV spectral range is not solved completely, and there are few available measurements. The major difficulty is insufficient correlation between photosynthetic and photoprotective pigments of phytoplankton absorbing in the visible and UV respectively. We propose to empirically parameterize seawater absorption in the UV on a basis of available data sets of bio-optical measurements from a variety of ocean waters. Another problem is the lack of reliable data on pure seawater absorption in the UV. Laboratory measurements of the UV absorption of both pure water and pure seawater are required.

Vasilkov, Alexander P.↗

Multi-Decadal Nitrogen Dioxide and Derived Products from Satellites (MINDS) Datasets Released by NASA GES DISC and Their Applications for Air Quality

Nitrogen dioxide (NO2), a pervasive air pollutant, comes from vehicles, power plants, industrial emissions, and off-road sources such as construction or lawn and gardening equipment. The NASA Goddard Earth Sciences Data and Information Services Center (GES DISC) curates many remote sensing datasets with NO2 retrievals, which have been utilized for air quality research and applications. The remotely-sensed datasets include those generated by the Ozone Monitoring Instrument (OMI) on the Aura satellite, the TROPOspheric Monitoring Instrument (TROPOMI) onboard the Copernicus Sentinel-5 Precursor (S5P), and the Ozone Mapping and Profiling Suite (OMPS) Nadir-Mapper (NM) instrument on the Suomi National Polar-orbiting Partnership (S- NPP). In collaboration with the NASA Making Earth System Data Records for Use in Research Environments (MEaSUREs) Multi-Decadal Nitrogen Dioxide and Derived Products from Satellites (MINDS) project, the GES DISC recently released MINDS datasets. The NASA MEaSUREs MINDS project aims to develop long-term NO2 global data records by adapting a consistent retrieval algorithm to multiple instrument measurements. Long-term data records will be achieved by applying consistent retrieval approaches to multiple satellite instruments, including OMI (2004 - ); the Global Ozone Monitoring Experiment (GOME, 1995-2011) onboard the second European Remote Sensing satellite (ERS-2); the Scanning Imaging Spectrometer for Atmospheric Cartography (SCIAMACHY, 2002-2012) onboard the ENVIronmental SATellite (ENVISAT); GOME-2 on the Meteorological Operational satellites (MetOp-A and MetOp-B, 2006 - ); and TROPOMI onboard the Copernicus S5P (2017 - ). The long-term record (1995 to present) of MINDS datasets makes them very useful for air quality trend studies. Some MINDS datasets with high spatial resolution of only a few kilometers can be used for air quality research and applications at regional scales. In this presentation, we will introduce all of the MINDS products and services, and demonstrate use cases of MINDS data for studying air quality. We will also present a few other NO2 datasets acquired from NASA’s Health and Air Quality Applied Sciences Team (HAQAST), to be archived and distributed by the GES DISC, and highlight some of their applications for air quality and health.

Feng Ding↗

Interpretation of TOMS Observations of Tropical Tropospheric Ozone with a Global Model and In Situ Observations

We interpret the distribution of tropical tropospheric ozone columns (TTOCs) from the Total Ozone Mapping Spectrometer (TOMS) by using a global three-dimensional model of tropospheric chemistry (GEOS-CHEM) and additional information from in situ observations. The GEOS-CHEM TTOCs capture 44% of the variance of monthly mean TOMS TTOCs from the convective cloud differential method (CCD) with no global bias. Major discrepancies are found over northern Africa and south Asia where the TOMS TTOCs do not capture the seasonal enhancements from biomass burning found in the model and in aircraft observations. A characteristic feature of these northern topical enhancements, in contrast to southern tropical enhancements, is that they are driven by the lower troposphere where the sensitivity of TOMS is poor due to Rayleigh scattering. We develop an efficiency correction to the TOMS retrieval algorithm that accounts for the variability of ozone in the lower troposphere. This efficiency correction increases TTOC's over biomass burning regions by 3-5 Dobson units (DU) and decreases them by 2-5 DU over oceanic regions, improving the agreement between CCD TTOCs and in situ observations. Applying the correction to CCD TTOCs reduces by approximately DU the magnitude of the "tropical Atlantic paradox" [Thompson et al, 2000], i.e. the presence of a TTOC enhancement over the southern tropical Atlantic during the northern African biomass burning season in December-February. We reproduce the remainder of the paradox in the model and explain it by the combination of upper tropospheric ozone production from lightning NOx, peristent subsidence over the southern tropical Atlantic as part of the Walker circulation, and cross-equatorial transport of upper tropospheric ozone from northern midlatitudes in the African "westerly duct." These processes in the model can also account for the observed 13-17 DU persistent wave-1 pattern in TTOCs with a maximum above the tropical Atlantic and a minimum over the tropical Pacific during all seasons. The photochemical effects of mineral dust have only a minor role on the modeled distribution of TTOCs, including over northern Africa, due to multiple competing effects. The photochemical effects of mineral dust globally decease annual mean OH concentrations by 9%. A global lightning NOx source of 6 Tg N yr(sup -1) in the model produces a simulation that is most consistent with TOMS and in situ observations.

Martin, Randall V.↗