Search NASA⌕ Search

SEARCH · Search NASA

Results for “PHASE DETECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Infrared Speckle Interferometry with 2-D Arrays

We describe results from a program of speckle interferometry with two-dimensional infrared array detectors. Analysis of observations of eta Carinae made with 58 x 62 InSb detector are discussed. The data have been analyzed with both the Labeyrie autocorrelation, a deconvolution of shift-and-add data, and a phase restoration process. Development of a new camera based on a much lower noise HgCdTe detector will lead to a significant improvement i limiting magnitude for IR speckle interferometry.

Harvey, P. M.↗

A cavity radiometer for Earth albedo measurement, phase 1

Radiometric measurements of the directional albedo of the Earth requires a detector with a flat response from 0.2 to 50 microns, a response time of about 2 seconds, a sensitivity of the order of 0.02 mw/sq cm, and a measurement uncertainty of less than 5 percent. Absolute cavity radiometers easily meet the spectral response and accuracy requirements for Earth albedo measurements, but the radiometers available today lack the necessary sensitivity and response time. The specific innovations addressed were the development of a very low thermal mass cavity and printed/deposited thermocouple sensing elements which were incorporated into the radiometer design to produce a sensitive, fast response, absolute radiometer. The cavity is applicable to the measurement of the reflected and radiated fluxes from the Earth surface and lower atmosphere from low Earth orbit satellites. The effort consisted of requirements and thermal analysis; design, construction, and test of prototype elements of the black cavity and sensor elements to show proof-of-concept. The results obtained indicate that a black body cavity sensor that has inherently a flat response from 0.2 to 50 microns can be produced which has a sensitivity of at least 0.02 mw/sq cm per micro volt ouput and with a time constant of less than two seconds. Additional work is required to develop the required thermopile.

Source record↗

Synchronous Phase-Resolving Flash Range Imaging

An apparatus, now undergoing development, for range imaging based on measurement of the round-trip phase delay of a pulsed laser beam is described. The apparatus would operate in a staring mode. A pulsed laser would illuminate a target. Laser light reflected from the target would be imaged on a verylarge- scale integrated (VLSI)-circuit image detector, each pixel of which would contain a photodetector and a phase-measuring circuit. The round-trip travel time for the reflected laser light incident on each pixel, and thus the distance to the portion of the target imaged in that pixel, would be measured in terms of the phase difference between (1) the photodetector output pulse and (2) a local-oscillator signal that would have a frequency between 10 and 20 MHz and that would be synchronized with the laser-pulse-triggering signal.

Pain, Bedabrata↗

Characterization of 2.5 microns HgCdTe detectors for low-background applications

A program of testing aimed at the evaluation of systems that have the potential to provide the level of performance required for use in space-based instruments was undertaken and their usefulness appraised for astronomy. The results of the first phase of the program to characterize selected pixels of a HgCdTe photovoltaic array detector were reported.

Depoy, D. L.↗

Technology Development Plan for the Baseline Detector System of the X-Ray Microcalorimeter Spectrometer (XMS) of the International X-Ray Observatory (IXO)

The primary purpose of this document is to present the technology development plan for the XMS detector system. It covers the current status (including assessment of the Technology Readiness Level, TRL, and a justification of the level assigned), the roadmap to progress to a level between TRL 5 and TRL 6 by the middle of 2012, and an assessment of the associated cost. A secondary purpose of this document is to address the Action Items raised at the XMS Phase-A Study Mid-Term Review that pertain to the detector system (AI #4, #8, and #9).

Kilbourne, C. A.↗

Beamline Electrostatic Levitator (BESL) for in-situ High Energy K-Ray Diffraction Studies of Levitated Solids and Liquids at High Temperature

Determinations of the phase formation sequence, the crystal structures and the thermodynamic properties of materials at high temperatures are difficult because of contamination from the sample container and environment. Containerless processing techniques, such as electrostatic (ESL), electromagnetic (EML), aerodynamic, and acoustic levitation, are most suitable these studies. An adaptation of ESL for in-situ structural studies of a wide range of materials, including metals, semiconductors, insulators using high energy (125 keV) synchrotron x-rays is described here. This beamline ESL (BESL) allows the in-situ determination of the atomic structures of equilibrium solid and liquid phases, including undercooled liquids, as well as real-time studies of solid-solid and liquid-solid phase transformations. The use of image plate (MAR345) or GE-Angio detectors enables fast (30 ms - 1s) acquisition of complete diffraction patterns over a wide q-range (4 - 140/mm). The wide temperature range (300 - 2500 K), containerless processing under high vacuum (10(exp -7) - 10(exp -8) torr), and fast data acquisition, make BESL particularly suitable for phase diagram studies of high temperature materials. An additional, critically important, feature of BESL is the ability to also make simultaneous measurement of a host of thermo-physical properties, including the specific heat, enthalpy of transformation, solidus and liquidus temperatures, density, viscosity, and surface tension; all on the same sample and simultaneous with the structural measurements.

Gangopadhyay, A. K.↗

Geometric correction process for the Landsat-4 Thematic Mapper

The processing approaches which form the basis of the Landsat-4 Thematic Mapper (TM) geometric correction system are summarized. The correction is accomplished in two phases. In the first phase, correction data are generated. The spacecraft position, TM frame attitude, TM scanning mirror position, and detector sampling are found as a function of time through a combination of flight segment measurements, ground segment modeling, and control point information. The data, along with the earth position and geoid model, are used to determine the earth location for each TM image sample. Then, using map projections, correction data can be generated which define the location of each TM image sample on the output coordinate system. In the second phase, the correction data are used to resample TM detector samples onto the output coordinate system.

Beyer, E. P.↗

Aqueous nitrite ion determination by selective reduction and gas phase nitric oxide chemiluminescence

An improved method of flow injection analysis for aqueous nitrite ion exploits the sensitivity and selectivity of the nitric oxide (NO) chemilluminescence detector. Trace analysis of nitrite ion in a small sample (5-160 microL) is accomplished by conversion of nitrite ion to NO by aqueous iodide in acid. The resulting NO is transported to the gas phase through a semipermeable membrane and subsequently detected by monitoring the photoemission of the reaction between NO and ozone (O3). Chemiluminescence detection is selective for measurement of NO, and, since the detection occurs in the gas-phase, neither sample coloration nor turbidity interfere. The detection limit for a 100-microL sample is 0.04 ppb of nitrite ion. The precision at the 10 ppb level is 2% relative standard deviation, and 60-180 samples can be analyzed per hour. Samples of human saliva and food extracts were analyzed; the results from a standard colorimetric measurement are compared with those from the new chemiluminescence method in order to further validate the latter method. A high degree of selectivity is obtained due to the three discriminating steps in the process: (1) the nitrite ion to NO conversion conditions are virtually specific for nitrite ion, (2) only volatile products of the conversion will be swept to the gas phase (avoiding turbidity or color in spectrophotometric methods), and (3) the NO chemiluminescence detector selectively detects the emission from the NO + O3 reaction. The method is free of interferences, offers detection limits of low parts per billion of nitrite ion, and allows the analysis of up to 180 microL-sized samples per hour, with little sample preparation and no chromatographic separation. Much smaller samples can be analyzed by this method than in previously reported batch analysis methods, which typically require 5 mL or more of sample and often need chromatographic separations as well.

NASA Discipline Environmental Health↗

Experimental Validation of Pulse Phase Tracking for X-Ray Pulsar Based

Pulsars are a form of variable celestial source that have shown to be usable as aids for autonomous, deep space navigation. Particularly those sources emitting in the X-ray band are ideal for navigation due to smaller detector sizes. In this paper X-ray photons arriving from a pulsar are modeled as a non-homogeneous Poisson process. The method of pulse phase tracking is then investigated as a technique to measure the radial distance traveled by a spacecraft over an observation interval. A maximum-likelihood phase estimator (MLE) is used for the case where the observed frequency signal is constant. For the varying signal frequency case, an algorithm is used in which the observation window is broken up into smaller blocks over which an MLE is used. The outputs of this phase estimation process were then looped through a digital phase-locked loop (DPLL) in order to reduce the errors and produce estimates of the doppler frequency. These phase tracking algorithms were tested both in a computer simulation environment and using the NASA Goddard Space flight Center X-ray Navigation Laboratory Testbed (GXLT). This provided an experimental validation with photons being emitted by a modulated X-ray source and detected by a silicon-drift detector. Models of the Crab pulsar and the pulsar B1821-24 were used in order to generate test scenarios. Three different simulated detector trajectories were used to be tracked by the phase tracking algorithm: a stationary case, one with constant velocity, and one with constant acceleration. All three were performed in one-dimension along the line of sight to the pulsar. The first two had a constant signal frequency and the third had a time varying frequency. All of the constant frequency cases were processed using the MLE, and it was shown that they tracked the initial phase within 0.15% for the simulations and 2.5% in the experiments, based on an average of ten runs. The MLE-DPLL cascade version of the phase tracking algorithm was used in the varying frequency case. This resulted in tracking of the phase and frequency by the DPLL outputs in both the simulation and experimental environments. The crab pulsar was experimentally tested with a trajectory with a higher acceleration. In this case the phase error tended toward zero as the observation extended to 250 seconds and the doppler frequency error tended to zero in under 100 seconds.

Experimental↗

The infrared spectrograph during the SIRTF pre-definition phase

A test facility was set up to evaluate back-illuminated impurity band detectors constructed for an infrared spectrograph to be used on the Space Infrared Telescope Facility (SIRTF). Equipment built to perform the tests on these arrays is described. Initial tests have been geared toward determining dark current and read noise for the array. Four prior progress reports are incorporated into this report. They describe the first efforts in the detector development and testing effort; testing details and a new spectrograph concept; a discussion of resolution issues raised by the new design; management activities; a review of computer software and testing facility hardware; and a review of the preamplifier constructed as well as a revised schematic of the detector evaluation facility.

Houck, James R.↗

Characterization of Dual-Band Infrared Detectors for Application to Remote Sensing

NASA Langley Research Center (LaRC), in partnership with the Rensselaer Polytechnic Institute (RPI), developed photovoltaic infrared (IR) detectors suitable at two different wavelengths using Sb-based material systems. Using lattice-matched InGaAsSb grown on GaSb substrates, dual wavelength detectors operating at 1.7 and 2.5 micron wavelengths can be realized. P-N junction diodes are fabricated on both GaSb and InGaAsSb materials. The photodiode on GaSb detects wavelengths at 1.7 micron and the InGaAsSb detector detects wavelengths at 2.2 micron or longer depending on the composition. The films for these devices are grown by metal-organic vapor phase epitaxy (MOVPE). The cross section of the independently accessed back-to-back photodiode dual band detector consists of a p-type substrate on which n-on-p GaInAsSb junction is grown, followed by a p-on-n GaSb junction. There are three ohmic contacts in this structure, one to the p-GaSb top layer, one to the n-GaSb/n-GaInAsSb layer and one to the p-type GaSb substrate. The common terminal is the contact to the n-GaSb/n-GaInAsSb layer. The contact to the n-GaSb/p-GaInAsSb region of the photodiode in the dual band is electrically connected and is accessed at the edge of the photodiode. NASA LaRC acquired the fabricated dual band detector from RPI and characterized the detector at its Detector Characterization Laboratory. Characterization results, such as responsivity, noise, quantum efficiency, and detectivity will be presented.

Abedin, M. Nurul↗

Energy spectra and pitch angle distributions of storm-time and substorm injected protons.

Discussion of the energy spectra and pitch angle distributions of ring current protons observed with the solid-state proton detector of Explorer 45 during the main and fast recovery phases of a storm on Dec. 17, 1971. Appearances of characteristic changes in the pitch angle distributions of roughly 100-eV protons are interpreted as pitch angle dispersion of rapidly injected protons during their azimuthal drift at L values above 5.

Konradi, A.↗

Apparatus and method for stabilized phase detection for binary signal tracking loops

Apparatus and method is presented for phase detection in binary signal tracking loops wherein two bandpass detectors are alternately interchanged between electrical connection with two local code reference tracking signals in order to cancel any adverse effect of gain imbalance in the bandpass detectors and direct current offset or drift. The detectors are time shared in multiplex fashion between the two local reference signals.

Hopkins, P. M.↗

Study of spectral/radiometric characteristics of the thematic mapper for land use applications

The previous characterization of scan-related low-frequency noise was confirmed and extended through analysis of reflective-band data from another nighttime acquisition. Amplitude and phase relationships of the level shifts were determined for each detector in each of free full frames. Analysis of scan-direction-related signal droop effects in nighttime data from the reflective bands was begun with encouraging initial observations. Also, an effort to characterize high-frequency noise in the reflective bands through Fourier analysis of nighttime data was initiated. Recommendations are made relative to the choice of radiometric calibration constants in the thematic mapper image processing system for the routine processing of TM data. Non-linear (piece-wise linear) calibration curves are recommended.

Malila, W. A.↗

Hard X-ray delays

High time resolution hard X-ray rates with good counting statistics over 5 energy intervals were obtained using a large area balloon-borne scintillation detector during the 27 June 1980 solar flare. The impulsive phase of the flare was comprised of a series of major bursts of several to several tens of seconds long. Superimposed on these longer bursts are numerous smaller approximately 0.5 to 1.0 second spikes. The time profiles for different energies were cross-correlated for the major bursts. The rapid burst decay rates and the simultaneous peaks below 120 keV both indicate a rapid electron energy loss process. Thus, the flux profiles reflect the electron acceleration/injection process. The fast rate data was obtained by a burst memory in 8 and 32 msec resolution over the entire main impulsive phase. These rates will be cross-correlated to look for short time delays and to find rapid fluctuations. However, a cursory examination shows that almost all fluctuations, down to the 5% level, were resolved with 256 msec bins.

Schwartz, Richard A.↗

Development of large CCD arrays with enhanced UV performance

A development status evaluation is presented for proprietary UV-range CCDs for military and scientific applications requiring pixel sizes in the 18-micron range. The most recent developments in UV/X-ray responsive detectors have their bases in the backside illumination of multipinned phase (MPP) 1024 x 1024 CCD arrays, as well as in the initial exploration of open-pinned phase (OPP) techniques. The frontside performance of both MPP and OPP devices is noted to be excellent as well, and pinouts and mounting techniques have been defined which allow easy front-back operation comparisons. Novel backside processing techniques are being refined.

Varian, Richard H.↗

Development of the Burst and Transient Source Experiment (BATSE)

The Burst and Transient Source Experiment (BATSE), one of four instruments on the Gamma Ray Observatory, consists of eight identical detector modules mounted on the corners of the spacecraft. Developed at MSFC, BATSE is the most sensitive gamma ray burst detector flown to date. Details of the assembly and test phase of the flight hardware development are presented. Results and descriptions of calibrations performed at MSFC, TRW, and KSC are documented extensively. With the presentation of each calibration results, the reader is provided with the means to access raw calibration data for further review or analysis.

Horack, J. M.↗

Segmented mirror figure control for a space-based far-IR astronomical telescope

For segmented large mirrors to be used effectively for astronomy they must be actively aligned and controlled to extreme levels of precision. We consider the figure control problem for a spaceborne far-IR telescope, the Precision Segmented Reflector Project Focus Moderate Mission Telescope. We propose a two-stage approach. A figure initialization controller is used to achieve initial phasing and alignment of the telescope using an imaging science detector. A figure maintenance controller keeps the telescope aligned during normal operation using a laser metrology optical truss sensor system. We show that performance of any figure control system is subject to limits on the controllability of the wavefront. Maintenance controllers are additionally limited by considerations of the observability of the wavefront from the maintenance sensors. We show preliminary results for the figure initialization controller. We present a 'Wavefront Compensation' method for figure maintenance control that minimizes wavefront errors due to misalignment errors.

Redding, David↗