Search NASA⌕ Search

SEARCH · Search NASA

Results for “PHASE IMAGING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Contact and Phase-Contrast Imaging of Nanostructures by Femtosecond-Laser-Driven-Cluster-Based Debris-Free Soft X-Ray Source

The high-intensive source of soft X-ray emission was developed by femtosecond laser pulses irradiation of submicron size CO{sub 2} clusters, produced in custom designed super-sonic nozzle while mixing the 10% CO{sub 2}+90% He expanding gases. The LiF crystal soft X-ray detectors have been used for obtaining absorption images of ultrathin (nanoscale) foils and biological structures illuminated by the developed source. It was demonstrated that even if the foil is essentially transparent for the soft X-ray radiation (like 100 nm thick Zr foil), the image contrast could be significantly increased due to the influence of propagation-based phase-contrast effect, by placing the detector at the proper distance from the sample.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Ball Motion and Near-Field Spray Characteristics of a Gasoline Direct Injection Injector using an X-ray Phase-Contrast Imaging Technique under High-Injection Pressures

Here, the purpose of this study is to visualize the ball (needle) motion and near-field spray characteristics of a gasoline direct injection injector under different injection conditions and analyze the effect of the internal structure of the injector on the ball motion, near-field spray velocity, and post-injection process. The injection pressure is set to 10MPa, 20 MPa, and 30 MPa, and the energization duration is fixed at 1.5 ms. An advanced X-ray technique with high transmittance and low scattering, is used to visualize the internal structure and near-field spray characteristics of the injector, which is impossible with general light sources. The ball is found to tilt to the right in the Y-axial direction during stable motion because the driving force of fuel on the ball is larger on the left side owing to the larger distance of the ball from the left wall. In addition, during stable motion, the near-field velocity of a hole with a smaller inlet angle is significantly higher than that of a hole with a larger inlet angle. The hole with a smaller inlet angle display better atomization characteristics during the post-injection process under all values of injection pressure.

47 OTHER INSTRUMENTATION↗

Deep Learning Segmentation of Complex Features in Atomic-Resolution Phase-Contrast Transmission Electron Microscopy Images

Phase-contrast transmission electron microscopy (TEM) is a powerful tool for imaging the local atomic structure of materials. TEM has been used heavily in studies of defect structures of two-dimensional materials such as monolayer graphene due to its high dose efficiency. However, phase-contrast imaging can produce complex nonlinear contrast, even for weakly scattering samples. It is, therefore, difficult to develop fully automated analysis routines for phase-contrast TEM studies using conventional image processing tools. For automated analysis of large sample regions of graphene, one of the key problems is segmentation between the structure of interest and unwanted structures such as surface contaminant layers. In this study, we compare the performance of a conventional Bragg filtering method with a deep learning routine based on the U-Net architecture. We show that the deep learning method is more general, simpler to apply in practice, and produces more accurate and robust results than the conventional algorithm. We provide easily adaptable source code for all results in this paper and discuss potential applications for deep learning in fully automated TEM image analysis.

47 OTHER INSTRUMENTATION↗

Quantum Imaging of Magnetic Phase Transitions and Spin Fluctuations in Intrinsic Magnetic Topological Nanoflakes

Topological materials featuring exotic band structures, unconventional current flow patterns, and emergent organizing principles offer attractive platforms for the development of next-generation transformative quantum electronic technologies. The family of MnBi 2 T e4 (Bi 2 Te 3 )n materials is naturally relevant in this context due to their nontrivial band topology, tunable magnetism, and recently discovered extraordinary quantum transport behaviors. Despite numerous pioneering studies, to date, the local magnetic properties of MnBi 2 Te 4 (Bi 2 Te 3 )n remain an open question, hindering a comprehensive understanding of their fundamental material properties. Exploiting nitrogen-vacancy (NV) centers in diamond, we report nanoscale quantum imaging of magnetic phase transitions and spin fluctuations in exfoliated MnBi 2 Te 4 (Bi 2 Te 3 )n flakes, revealing the underlying spin transport physics and magnetic domains at the nanoscale. Furthermore, our results highlight the unique advantage of NV centers in exploring the magnetic properties of emergent quantum materials, opening new opportunities for investigating the interplay between topology and magnetism.

Antiferromagnetic materials↗

Melt dynamics of aluminum irradiated with ultrafast laser radiation at large intensities

Ablation of bulk aluminum has been investigated in situ using ultrafast laser radiation produced by chirped-pulse amplification technique (t{sub p}=80 fs, lambda=800 nm). Melt dynamics and the contribution of the amplified spontaneous emission (ASE) to the ablation have been studied experimentally and numerically for laser fluences well above ablation threshold (F < or approx. 10{sup 3}xF{sub thr}). Using transient quantitative phase microscopy (TQPm), dimensions and volume of ejected vapor, melt droplets, and liquid jets has been investigated. Computational analysis of the optical phase images has been used to determine the total volume of ejected material. A series of time-resolved phase images of vaporized material and/or melt, which are induced by n=1.8 pulses on an aluminum target, are obtained by means of TQPm up to temporal delay tau=1.65 mus after irradiation. Increase in material ejection rate is observed at delays tauapprox =300 ns and tauapprox =1.1 mus after the incident pulse. For large irradiation intensities a considerable contribution of ASE to ablation dynamics has been detected. Ex situ measurements of the ablated material by means of white-light interferometry and scanning electron microscopy provides corresponding factual removed volumes and highlight the pulse-to-pulse morphology changes.

36 MATERIALS SCIENCE↗

Development of a phase contrast imaging system based on a yttrium aluminum garnet laser with folded beam for observations of density fluctuations in compact helical system

A near-infrared laser phase contrast optical system incorporating a folded beam was developed in order to measure the distribution of density fluctuations in a high-temperature plasma. The coherent light source used was an yttrium aluminum garnet laser stabilized by a ring oscillator. The probe beam system separates and reflects the incident and exiting beams with a polarizer and a fully reflective mirror with a waveplate. This system was employed with a compact helical system to detect fluctuations at the plasma edge.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Four-dimensional dose evaluation using deformable image registration in radiotherapy for liver cancer

Purpose: In order to evaluate the dosimetric impact of respiratory motion on the dose delivered to the target volume and critical organs during free-breathing radiotherapy, a four-dimensional dose was evaluated using deformable image registration (DIR). Methods: Four-dimensional computed tomography (4DCT) images were acquired for 11 patients who were treated for liver cancer. Internal target volume-based treatment planning and dose calculation (3D dose) were performed using the end-exhalation phase images. The four-dimensional dose (4D dose) was calculated based on DIR of all phase images from 4DCT to the planned image. Dosimetric parameters from the 4D dose, were calculated and compared with those from the 3D dose. Results: There was no significant change of the dosimetric parameters for gross tumor volume (p > 0.05). The increase D{sub mean} and generalized equivalent uniform dose (gEUD) for liver were by 3.1%{+-} 3.3% (p= 0.003) and 2.8%{+-} 3.3% (p= 0.008), respectively, and for duodenum, they were decreased by 15.7%{+-} 11.2% (p= 0.003) and 15.1%{+-} 11.0% (p= 0.003), respectively. The D{sub max} and gEUD for stomach was decreased by 5.3%{+-} 5.8% (p= 0.003) and 9.7%{+-} 8.7% (p= 0.003), respectively. The D{sub max} and gEUD for right kidney was decreased by 11.2%{+-} 16.2% (p= 0.003) and 14.9%{+-} 16.8% (p= 0.005), respectively. For left kidney, D{sub max} and gEUD were decreased by 11.4%{+-} 11.0% (p= 0.003) and 12.8%{+-} 12.1% (p= 0.005), respectively. The NTCP values for duodenum and stomach were decreased by 8.4%{+-} 5.8% (p= 0.003) and 17.2%{+-} 13.7% (p= 0.003), respectively. Conclusions: The four-dimensional dose with a more realistic dose calculation accounting for respiratory motion revealed no significant difference in target coverage and potentially significant change in the physical and biological dosimetric parameters in normal organs during free-breathing treatment.

60 APPLIED LIFE SCIENCES↗

Deep-Learning Electron Diffractive Imaging

Here, we report the development of deep-learning coherent electron diffractive imaging at subangstrom resolution using convolutional neural networks (CNNs) trained with only simulated data. We experimentally demonstrate this method by applying the trained CNNs to recover the phase images from electron diffraction patterns of twisted hexagonal boron nitride, monolayer graphene, and a gold nanoparticle with comparable quality to those reconstructed by a conventional ptychographic algorithm. Fourier ring correlation between the CNN and ptychographic images indicates the achievement of a resolution in the range of 0.70 and 0.55 Å. We further develop CNNs to recover the probe function from the experimental data. The ability to replace iterative algorithms with CNNs and perform real-time atomic imaging from coherent diffraction patterns is expected to find applications in the physical and biological sciences.

47 OTHER INSTRUMENTATION↗

Differential Radar Interferometry Maps Changes In Elevation

Differential radar interferometry uses data from synthetic-aperture radar (SAR). Three passes of SAR yield three amplitude-and-phase images, from which two interferograms (phase-difference images) made. Interferograms used to make third, "double-difference" interferogram indicating vertical motion of terrain between passes. Vertical earthquake motions as small as 1 cm detectable. Used to make extensive, accurate maps of such geophysical phenomena as heaving and buckling in fault zones, motions to tectonic plates, residual displacements from earthquakes, motions from prevolcanic swelling, motions of glaciers, tides, and thermal expansion of mountains from diurnal heating.

Gabriel, Andrew K.↗

Single-frame far-field diffractive imaging with randomized illumination

We introduce a single-frame diffractive imaging method called randomized probe imaging (RPI). In RPI, a sample is illuminated by a structured probe field containing speckles smaller than the sample’s typical feature size. Quantitative amplitude and phase images are then reconstructed from the resulting far-field diffraction pattern. The experimental geometry of RPI is straightforward to implement, requires no near-field optics, and is applicable to extended samples. When the resulting data are analyzed with a complimentary algorithm, reliable reconstructions which are robust to missing data are achieved. To realize these benefits, a resolution limit associated with the numerical aperture of the probe-forming optics is imposed. RPI therefore offers an attractive modality for quantitative X-ray phase imaging when temporal resolution and reliability are critical but spatial resolution in the tens of nanometers is sufficient. We discuss the method, introduce a reconstruction algorithm, and present two proof-of-concept experiments: one using visible light, and one using soft X-rays.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Deep Learning Automates the Quantitative Analysis of Individual Cells in Live-Cell Imaging Experiments

Live-cell imaging has opened an exciting window into the role cellular heterogeneity plays in dynamic, living systems. A major critical challenge for this class of experiments is the problem of image segmentation, or determining which parts of a microscope image correspond to which individual cells. Current approaches require many hours of manual curation and depend on approaches that are difficult to share between labs. They are also unable to robustly segment the cytoplasms of mammalian cells. Here, we show that deep convolutional neural networks, a supervised machine learning method, can solve this challenge for multiple cell types across the domains of life. We demonstrate that this approach can robustly segment fluorescent images of cell nuclei as well as phase images of the cytoplasms of individual bacterial and mammalian cells from phase contrast images without the need for a fluorescent cytoplasmic marker. These networks also enable the simultaneous segmentation and identification of different mammalian cell types grown in co-culture. A quantitative comparison with prior methods demonstrates that convolutional neural networks have improved accuracy and lead to a significant reduction in curation time. We relay our experience in designing and optimizing deep convolutional neural networks for this task and outline several design rules that we found led to robust performance. We conclude that deep convolutional neural networks are an accurate method that require less curation time, are generalizable to a multiplicity of cell types, from bacteria to mammalian cells, and expand live-cell imaging capabilities to include multi-cell type systems.

59 BASIC BIOLOGICAL SCIENCES↗

TU-AB-201-11: A Novel Theoretical Framework for MRI-Only Image Guided LDR Prostate and Breast Brachytherapy Implant Dosimetry

Purpose: To propose a novel framework for accurate model-based dose calculations using only MR images for LDR prostate and breast seed implant brachytherapy. Methods: Model-based dose calculation methodologies recommended by TG-186 require further knowledge about specific tissue composition, which is challenging with MRI. However, relying on MRI-only for implant dosimetry would reduce the soft tissue delineation uncertainty, costs, and uncertainties associated with multi-modality registration and fusion processes. We propose a novel framework to address this problem using quantitative MRI acquisitions and reconstruction techniques. The framework includes three steps: (1) Identify the locations of seeds(2) Identify the presence (or absence) of calcification(s)(3) Quantify the water and fat content in the underlying tissueSteps (1) and (2) consider the sources that limit patient dosimetry, particularly the inter-seed attenuation and the calcified regions; while step (3) targets the quantification of the tissue composition to consider the heterogeneities in the medium. Our preliminary work has shown that the seeds and the calcifications can be identified with MRI using both the magnitude and the phase images. By employing susceptibility-weighted imaging with specific post-processing techniques, the phase images can be further explored to distinguish the seeds from the calcifications. Absolute quantification of tissue, water, and fat content is feasible and was previously demonstrated in phantoms and in-vivo applications, particularly for brain diseases. The approach relies on the proportionality of the MR signal to the number of protons in an image volume. By employing appropriate correction algorithms for T1 - and T2*-related biases, B1 transmit and receive field inhomogeneities, absolute water/fat content can be determined. Results: By considering calcification and interseed attenuation, and through the knowledge of water and fat mass density, accurate patient-specific implant dosimetry can be achieved with MRI-only. Conclusion: The proposed framework showed that model-based dose calculation is feasible using MRI-only state-of-the-art techniques.

60 APPLIED LIFE SCIENCES↗

Imaging the Phase Separation in Atomically Thin Buried SrTiO{sub 3} Layers by Electron Channeling

A phase-separation instability, resulting in the dewetting of thin SrTiO{sub 3} films grown on Si(100) is shown by scanning transmission electron microscopy. Plan-view imaging of 1-nm thick, buried SrTiO{sub 3} films was achieved by exploiting electron channeling through the substrate to focus the incident 0.2 nm beam down to a 0.04 nm diameter, revealing a nonuniform coverage by epitaxial SrTiO{sub 3} islands and 2x1 Sr-covered regions. Density-functional calculations predict the ground state is a coexistence of 2x1 Sr-reconstructed Si and Sr-deficient SrTiO{sub 3}, in correspondence with the observed islanding.

36 MATERIALS SCIENCE↗

Quantitative electron density characterization of soft tissue substitute plastic materials using grating-based x-ray phase-contrast imaging

Many scientific research areas rely on accurate electron density characterization of various materials. For instance in X-ray optics and radiation therapy, there is a need for a fast and reliable technique to quantitatively characterize samples for electron density. We present how a precise measurement of electron density can be performed using an X-ray phase-contrast grating interferometer in a radiographic mode of a homogenous sample in a controlled geometry. A batch of various plastic materials was characterized quantitatively and compared with calculated results. We found that the measured electron densities closely match theoretical values. The technique yields comparable results between a monochromatic and a polychromatic X-ray source. Measured electron densities can be further used to design dedicated X-ray phase contrast phantoms and the additional information on small angle scattering should be taken into account in order to exclude unsuitable materials.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Feasibility study of the iterative x-ray phase retrieval algorithm

An iterative phase retrieval algorithm was previously investigated for in-line x-ray phase imaging. Through detailed theoretical analysis and computer simulations, we now discuss the limitations, robustness, and efficiency of the algorithm. The iterative algorithm was proved robust against imaging noise but sensitive to the variations of several system parameters. It is also efficient in terms of calculation time. It was shown that the algorithm can be applied to phase retrieval based on one phase-contrast image and one attenuation image, or two phase-contrast images; in both cases, the two images can be obtained either by one detector in two exposures, or by two detectors in only one exposure as in the dual-detector scheme.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

AGR-1 UCO Kernel Phase Analysis Imaging Archive

UCO kernels in tri-structural isotropic (TRISO) particles consist of a heterogeneous mixture of uranium oxide and uranium carbide. During the Advanced Gas Reactor Fuel Development and Qualification (AGR) Program, mean kernel composition was specified based on bulk measurements of uranium, oxygen, and carbon content, as well as the resulting O/U, C/U, and O+C/U ratios. Further development of quality control characterization methods has resulted in a method for more direct measurement of phase fractions on a per-kernel basis using optical microscopy of polished kernel cross sections. This report provides benchmark values for this analysis method when applied to kernels from the AGR-1 campaign and to the raw images used.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗