Search NASA⌕ Search

SEARCH · Search NASA

Results for “PNEUMATIC CONTROL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

284 records · Page 16

Development Unit for In-Space Pneumatic Helium Transfer Compressor

High-pressure gaseous helium (GHe) plays a critical role in spacecraft propulsion due to its near exclusive use for pressurization of propellant tanks. Several different designs for helium compressor technologies have been developed for use on Earth; however, significant design changes are required to meet the power, thermal/heat dissipation, vacuum, vibration/shock, size, mass, and efficiency requirements needed for space and launch environments. Currently, no capability exists for mass efficient on-orbit GHe (or xenon) transfer, nor has it ever been attempted. This effort proposed several challenging requirements for the vendor to develop a one-of-a-kind pneumatic compressor prototype. In order to develop a compressor prototype at a TRL 4, a partnership with Air Squared, Inc. was established. This CIF project concluded with the receipt of a prototype along with a proposed design for a flight unit; however, it will not be built due to funding limitations. The vendor had moderate success with initial testing of the prototype at lower pressures (with shimming configured for low pressure). There were delays with testing since the unit was built for higher pressures and the low pressure shimming was challenging to implement. It was found that operation of the compressor at lower pressures caused increased friction on the motor shaft which resulted in the unit drawing more power (current). This was initially thought to be a motor or controller defect. Subsequent high pressure testing at KSC showed that the friction was reduced for the optimal design point (with a high pressure shimming configuration) and the motor (and controller) performed nominally. Following the vendor testing, the unit was tuned/shimmed for a nominal inlet pressure and shipped to KSC for high pressure testing using the custom-designed setup in the Vehicle Assembly Building. The unit performed well, showing the capability to achieve over higher pressure of compression. The pressure differential could likely increase, however, the maximum output of the power supply used for testing was reached, limiting the compressor motor’s capability. Following the GN2 testing, the test setup was converted to GHe with at high pressure. It was shown that although the unit was unable to achieve similar high pressure differentials due to reverse leakage of the GHe through the scroll tip seals, it did achieve the desired GHe compression. This may still be useful for some applications, however, for the purpose of on-orbit GHe transfer, the single stage design would need to be changed to include multiple stages to achieve the compression goals initially proposed by the project.

Brian Nufer↗

Wind Tunnel Testing of High Efficiency Low Power (HELP) Actuation for Active Flow Control

A High Efficiency Low Power (HELP) methodology has been successfully developed and tested on an active flow control (AFC) version of the 10%-scale high-lift Common Research Model (CRM-HL) at the NASA Langley Research Center 14- by 22-Foot Subsonic Tunnel (14x22). The AFC variant of the CRM-HL, designated as CRM-SHL-AFC, was integrated with modular HELP actuator cartridges on the shoulder of its highly deflected (≥50°) simplehinged flaps. A reference conventional CRM-HL configuration equipped with Fowler flaps and a nacelle chine was chosen to provide the targeted lift enhancement goals and for comparison with the results of the CRM-SHL-AFC. The current data are presented with the Transonic Wall Interference Correction System (TWICS) method applied. The HELP actuators, which use a combination of unsteady sweeping jets and steady discrete jets in tandem, were designed to overcome strong adverse pressure gradients, while minimizing the pneumatic power usage. The power coefficient (C(sub π)), which takes account of both supply air pressure and mass flow usage for the AFC actuators, is a useful parameter for judging the actuators’ performance efficiency and perhaps for scaling-up of the AFC system. Full HELP actuation coverage with a constant spanwise nozzle pressure ratio (NPR) was able to achieve the lift enhancement goals for the entire lift curve and was found to be the most effective AFC case. For the most effective case, mass flow rates greater than ~0.91 lbm/s and NPR values greater than ~1.8 (corresponding to C(sub π) = 0.18) are needed to achieve the lift enhancement goal at α = 9°, whereas mass flow rates greater than ~1.23 lbm/s and NPR values greater than ~2.3 (corresponding to C(sub π) = 0.3) are needed to achieve the lift enhancement goal at α = 17°. Surface pressure distributions indicate that the HELP actuation on the flap shoulder increased the suction pressures (and flow circulation) globally in both the streamwise and the spanwise directions, and thereby enhanced the lift over the entire high-lift system. The CRM-SHLAFC configuration equipped with HELP actuation was able to match or exceed the lift performance of the reference conventional CRM-HL, thus meeting the objective of the research.

John C Lin↗

Computational analysis of forebody tangential slot blowing on the high alpha research vehicle

Current and future fighter aircraft can maneuver in the high-angle-of-attack flight regime while flying at low subsonic and transonic freestream Mach numbers. However, at any flight speed, the ability of the vertical tails to generate yawing moment is limited in high-angle-of-attack flight. Thus, any system designed to provide the pilot with additional side force and yawing moment must work in both low subsonic and transonic flight. However, previous investigations of the effectiveness of forebody tangential slot blowing in generating the desired control forces and moments have been limited to the low subsonic freestream flow regime. In order to investigate the effectiveness of tangential slot blowing in transonic flight, a computational fluid dynamics analysis was carried out during the grant period. Computational solutions were obtained at three different freestream Mach numbers and at various jet mass flow ratios. All results were obtained using the isolated F/A-18 forebody grid geometry at 30.3 degrees angle of attack. One goal of the research was to determine the effect of freestream Mach number on the effectiveness of forebody tangential slot blowing in generating yawing moment. The second part of the research studied the force onset time lag associated with blowing. The time required for the yawing moment to reach a steady-state value from the onset of blowing may have an impact on the implementation of a pneumatic system on a flight vehicle.

Gee, Ken↗

Mechanical counter pressure on the arm counteracts adverse effects of hypobaric exposures

INTRODUCTION: Current space suits have limited movement due to gas pressurization during exposure to the vacuum of space. Alternatively, if pressure is applied by an elastic garment vs. pneumatic garment to produce mechanical counter pressure (MCP), several advantages are possible. In this study, we investigate local microcirculatory and other effects produced with and without a prototype MCP glove and sleeve during exposure to varying levels of vacuum. METHODS: The entire arms of eight male volunteers were studied at normal ambient pressure and during 5 min exposures to -50, -100, and -150 mm Hg with and without the MCP glove and sleeve. Pressure distribution, skin microvascular flow, and temperature were measured. RESULTS: The MCP glove and sleeve generated over 200 mm Hg on the middle finger, dorsum of the hand, and the wrist. However, pressure was significantly lower on the forearm and the upper arm. Without the glove and sleeve, only two of eight subjects tolerated -100 mm Hg. Also, no subject tolerated -150 mm Hg. However, subjects tolerated all vacuum pressures wearing the glove and sleeve. Skin microvascular flow and temperature remained within control values with the glove and sleeve at a chamber pressure of -150 mm Hg. DISCUSSION: The MCP glove and sleeve counteracts adverse effects of vacuum exposures due to lower pressure differentials. Pressure levels over the hand and wrist are similar to those of the current U.S. space suit glove and sleeve, but additional development is required to increase MCP over the forearm and upper arm.

NASA Discipline Cardiopulmonary↗

Autonomous sensor-based dual-arm satellite grappling

Dual-arm satellite grappling involves the integration of technologies developed in the Sensing and Perception (S&P) Subsystem for object acquisition and tracking, and the Manipulator Control and Mechanization (MCM) Subsystem for dual-arm control. S&P acquires and tracks the position, orientation, velocity, and angular velocity of a slowly spinning satellite, and sends tracking data to the MCM subsystem. MCM grapples the satellite and brings it to rest, controlling the arms so that no excessive forces or torques are exerted on the satellite or arms. A 350-pound satellite mockup which can spin freely on a gimbal for several minutes, closely simulating the dynamics of a real satellite is demonstrated. The satellite mockup is fitted with a panel under which may be mounted various elements such as line replacement modules and electrical connectors that will be used to demonstrate servicing tasks once the satellite is docked. The subsystems are housed in three MicroVAX II microcomputers. The hardware of the S&P Subsystem includes CCD cameras, video digitizers, frame buffers, IMFEX (a custom pipelined video processor), a time-code generator with millisecond precision, and a MicroVAX II computer. Its software is written in Pascal and is based on a locally written vision software library. The hardware of the MCM Subsystem includes PUMA 560 robot arms, Lord force/torque sensors, two MicroVAX II computers, and unimation pneumatic parallel grippers. Its software is written in C, and is based on a robot language called RCCL. The two subsystems are described and test results on the grappling of the satellite mockup with rotational rates of up to 2 rpm are provided.

Wilcox, Brian↗

Design of Experiment for the Measurement of Aerosol Droplet Size Distribution of Temperature-Controlled Thermally Atomized Printed Electronic Inks

In-Space Manufacturing (ISM) centers around NASA’s growing need and ability to produce space technologies on demand in space. As the future of long term presence in space and deep space exploration approach, fundamental questions of our dependence on earth resupply to Low Earth Orbit (LEO) remain unanswered. ISM is leading various effort to evaluate the feasibility of producing essential spares and redundant parts on demand to enable a sustainable space-based supply chain model for part resupply. Among the parts and systems being considered, Avionics form the neural network of modern day aircraft and space vehicles providing a wealth of information ranging from Guidance, Navigation, and Control (GN&C) systems to on board Environmental Control and Life Support (ECLS) systems. Recent advances in the use of Aerosol Jet Technology to print Avionics components ranging from electrical traces on a circuit board to complex transistors and sensors raise the possibility of using such technology to reproduce or recreate electronic parts on demand with the help of custom electronics 3D printers. The challenge herein lies within the ability of such printers to generate and deposit an aerosol of electronic material utilizing processes independent of or enhanced by gravity to ensure controllably identical or improved behavior of the aerosol in an International Space Station (ISS) laboratory and on the ground. The behavior as well as the hazards and properties associated with such aerosols in a microgravity environment must be understood well in order to merit a feasible approach to utilizing them for manufacturing in space. In this report, we outline the experimental setup of a modified conventional vaping device to be used as the ideal gravity independent thermal atomization mechanism to generate aerosol. Our objective is to identify the ideal mass, density, and volume of our aerosolized droplets of ink to conclude that there exist a threshold of aerosolized ink droplet sizes that are indeed independent of the effects of gravity and remain stable after atomization. We use a Malvern Spraytec® Spray Particle Size Analyzer to perform real-time laser diffraction measurement of our ink droplets during atomization. The droplet size between conductive ink, dielectric ink and vegetable glycerin have been measured and contrasted. Furthermore, the mechanism of thermal atomization versus traditional pneumatic and ultrasonic atomization for operation in microgravity have been explored.

Wu, Chih-Hao↗

Zero-Gravity Locomotion Simulators: New Ground-Based Analogs for Microgravity Exercise Simulation

Maintaining health and fitness in crewmembers during space missions is essential for preserving performance for mission-critical tasks. NASA's Exercise Countermeasures Project (ECP) provides space exploration exercise hardware and monitoring requirements that lead to devices that are reliable, meet medical, vehicle, and habitat constraints, and use minimal vehicle and crew resources. ECP will also develop and validate efficient exercise prescriptions that minimize daily time needed for completion of exercise yet maximize performance for mission activities. In meeting these mission goals, NASA Glenn Research Center (Cleveland, OH, USA), in collaboration with the Cleveland Clinic (Cleveland, Ohio, USA), has developed a suite of zero-gravity locomotion simulators and associated technologies to address the need for ground-based test analog capability for simulating in-flight (microgravity) and surface (partial-gravity) exercise to advance the health and safety of astronaut crews and the next generation of space explorers. Various research areas can be explored. These include improving crew comfort during exercise, and understanding joint kinematics and muscle activation pattern differences relative to external loading mechanisms. In addition, exercise protocol and hardware optimization can be investigated, along with characterizing system dynamic response and the physiological demand associated with advanced exercise device concepts and performance of critical mission tasks for Exploration class missions. Three zero-gravity locomotion simulators are currently in use and the research focus for each will be presented. All of the devices are based on a supine subject suspension system, which simulates a reduced gravity environment by completely or partially offloading the weight of the exercising test subject s body. A platform for mounting treadmill is positioned perpendicularly to the test subject. The Cleveland Clinic Zero-g Locomotion Simulator (ZLS) utilizes a pneumatic subject load device to apply a near constant gravity-replacement load to the test subject during exercise, and is currently used in conjunction with the General Clinical Research Center for evaluating exercise protocols using a bedrest analog. The enhanced ZLS (eZLS) at NASA Glenn Research Center features an offloaded treadmill that floats on a thin film of air and interfaces to a force reaction frame via variably-compliant isolators, or vibration isolation system. The isolators can be configured to simulate compliant interfaces to the vehicle, which affects mechanical loading to crewmembers during exercise, and has been used to validate system dynamic models for new countermeasures equipment designs, such as the second International Space Station treadmill slated for use in 2010. In the eZLS, the test subject and exercise device can be pitched at the appropriate angle for partial gravity simulations, such as lunar gravity (1/6th earth gravity). On both the eZLS and the NASA-Johnson Space Center standalone ZLS installed at the University of Texas Medical Branch in Galveston, Texas, USA, the subject's body weight relative to the treadmill is controlled via a linear motor subject load device (LM-SLD). The LM-SLD employs a force-feedback closed-loop control system to provide a relatively constant force to the test subject during locomotion, and is set and verified for subject safety prior to each session. Locomotion data were collected during parabolic flight and on the eZLS. The purpose was to determine the similarities and differences between locomotion in actual and simulated microgravity. Subjects attained greater amounts of hip flexion during walking and running during parabolic flight. During running, subjects had greater hip range of motion. Trunk motion was significantly less on the eZLS than during parabolic flight. Peak impact forces, loading rate, and impulse were greater on the eZLS than during parabolic while walking with a low external load (EL) and rning with a high EL. Activation timing differences existed between locations in all muscles except for the rectus femoris. The tibialis anterior and gluteus maximus were active for longer durations on the eZLS than in parabolic flight during walking. Ground reaction forces were greater with the LM-SLD than with bungees during eZLS locomotion. While the eZLS serves as a ground-based analog, researchers should be aware that subtle, but measurable, differences in kinematics and leg musculature activities exist between the environments. Aside from space applications, zero-gravity locomotion simulators may help medical researchers in the future with development of rehabilitative or therapeutic protocols for injured or ill patients. Zero-gravity locomotion simulators may be used as a ground-based test bed to support future missions for space exploration, and eventually may be used to simulate planetary locomotion in partial gravity environments, including the Moon and Mars. Figure: Zero-gravity Locomotion Simulator at the Cleveland Clinic, Cleveland, Ohio, USA

Perusek, Gail P.↗

NASA Tech Briefs, October 2003

Topics covered include: Cryogenic Temperature-Gradient Foam/Substrate Tensile Tester; Flight Test of an Intelligent Flight-Control System; Slat Heater Boxes for Thermal Vacuum Testing; System for Testing Thermal Insulation of Pipes; Electrical-Impedance-Based Ice-Thickness Gauges; Simulation System for Training in Laparoscopic Surgery; Flasher Powered by Photovoltaic Cells and Ultracapacitors; Improved Autoassociative Neural Networks; Toroidal-Core Microinductors Biased by Permanent Magnets; Using Correlated Photons to Suppress Background Noise; Atmospheric-Fade-Tolerant Tracking and Pointing in Wireless Optical Communication; Curved Focal-Plane Arrays Using Back-Illuminated High-Purity Photodetectors; Software for Displaying Data from Planetary Rovers; Software for Refining or Coarsening Computational Grids; Software for Diagnosis of Multiple Coordinated Spacecraft; Software Helps Retrieve Information Relevant to the User; Software for Simulating a Complex Robot; Software for Planning Scientific Activities on Mars; Software for Training in Pre-College Mathematics; Switching and Rectification in Carbon-Nanotube Junctions; Scandia-and-Yttria-Stabilized Zirconia for Thermal Barriers; Environmentally Safer, Less Toxic Fire-Extinguishing Agents; Multiaxial Temperature- and Time-Dependent Failure Model; Cloverleaf Vibratory Microgyroscope with Integrated Post; Single-Vector Calibration of Wind-Tunnel Force Balances; Microgyroscope with Vibrating Post as Rotation Transducer; Continuous Tuning and Calibration of Vibratory Gyroscopes; Compact, Pneumatically Actuated Filter Shuttle; Improved Bearingless Switched-Reluctance Motor; Fluorescent Quantum Dots for Biological Labeling; Growing Three-Dimensional Corneal Tissue in a Bioreactor; Scanning Tunneling Optical Resonance Microscopy; The Micro-Arcsecond Metrology Testbed; Detecting Moving Targets by Use of Soliton Resonances; and Finite-Element Methods for Real-Time Simulation of Surgery.

Source record↗

Quantifying Leak Rates and Vacuum Impact on Granular Soil Column Pneumatic Seal

Introduction: All In-Situ Resource Utilization (ISRU) regolith reactor systems that aim to extract gases or vapors must maintain a seal along the flow path of the regolith from the inlet hopper to where extracted gases or vapors are generated. Using a column of regolith at the inlet has been proposed as an alternative to systems using series of mechanical valves to reduce mass and complexity. Preliminary investigations into the use of regolith itself as a barrier to escaping fluids have been conducted, which this research seeks to expand upon. Different vertical regolith simulant plug diameters and heights were tested under vacuum with dry nitrogen to observe leak rates and approximate steady state pressure gradient equilibria. The effect of absolute ambient pressure was also studied by repeating tests at incremental pressures ranging from 10e-5 Torr up to 1 atm to corroborate ambient bench tests from previous work. The impact of regolith dynamics was addressed to emulate continuous-feed regolith reaction processes by measuring leak rates through continuously draining simulant columns. OB-1 lunar highlands regolith simulant was used. Experimental Setup: Regolith simulant columns were constructed using a motorized butterfly valve separating upper acrylic tubes of various diameters from a larger, lower aluminum pipe plenum (See Figure 1). The butterfly valve was cracked open such that gas could freely pass through whereas regolith would bridge and stay suspended as a cohesive plug above in the acrylic portion. These assemblies were loaded into a vacuum chamber, and a compressed dry nitrogen line was routed into the lower plenum. Pressure transducers measured the absolute pressure of the lower plenum, which was compared to absolute chamber pressure to monitor the pressure gradient across the regolith simulant. A precision mass flow controller enabled fine control of plenum pressure. The plenum pressure was quasi-statically increased to set points informed by previous work [1] before shutting off the gas supply to allow the now pressurized gas volume to dissipate through the simulant into the chamber in what was referred to as a ‘leak test.’ In a separate set of tests, the pressure was allowed to quasi-statically build until visual disturbances in the soil were observed via remote camera feeds. Initial leak rate tests were repeated on the disturbed soil to observe changes in leak rates between initial as-poured and post-bubbling soil conditions. This test schedule was applied to simulant columns of three different diameters (approximately 2, 4, and 6 inches) as well as two different heights (around 8 and 16 inches) and was repeated at least three times for each configuration. Plenums were also pressurized while the butterfly valves were opened slightly further to facilitate slow, controlled, constant flowrate draining of the simulant to observe the impact that continuous-feed systems might have on leak rate through the regolith column. Finally, the regolith columns were reset and refilled and static leak rate tests were repeated approximately every decade in ambient pressure from 10e-5 Torr up to ambient conditions to observe the impact of transitioning out of the molecular flow regime on regolith column seal performance. Analysis: Trends with respect to each factor examined were constructed and reported alongside commentary on the most likely responsible physical phenomena. Confidence intervals were applied to the predictive findings of the data by quantifying instrumentation error and accounting for probabilistic impacts of curve fitting the generic exponential function onto pressure decay data. The leak rate is assumed directly proportional to the exponential term coefficient, while the steady-state static pressure gradient is assumed to be the asymptotic limit of each curve fit. Finally, a generic model developed by Ogino et al. [2] and later tuned for ambient testing was re-tuned using vacuum data to estimate leak rates on the lunar surface. Results: Pressure decay rates decreased up to 27-fold under vacuum when compared to ambient pressure, as shown in Figure 2. Simulant column diameter was found to exponentially correlate to both regolith column leak rate and steady-state equilibrium pressure delta. Height was found to be linearly related to leak rate –doubling the regolith column height consistently yielded around a 40% reduction in leak rate. Dynamic regolith draining was found to slightly increase leak rate, although to a lower degree than expected. Conclusion: Because of the transition into molecular gas flow through regolith, vacuum testing is required to properly estimate performance. Regolith columns should be designed as narrow as possible to avoid bridging and minimize leak rate, and as tall as is feasible to both further reduce leak rate and to help prevent bubbling, which has been shown to degrade the quality of the regolith seal. Disrupted soil was found to exhibit higher leak rates than pristine, as-poured soil, indicating the need to consider the impact of recovery from depressurization events. Regolith columns appear equally feasible for both dosed and continuous-feed reactors.

ISRU↗

Design and Development of a Laboratory-Scale Ice Adhesion Testing Device

When an aircraft traverses through clouds containing supercooled water droplets, in-flight icing can occur that negatively affects vehicle performance by increasing weight and drag leading to loss of lift. Super-cooled water droplets present in clouds that impact vehicle surfaces can lead to inflight icing any time during the year.1 Most events occur at temperatures ranging from 0 to -20degC. Ice generated on the aircraft can vary between clear/glaze, rime, and mixed (Fig. 1) depending on air temperature (-5 to -20degC), liquid water content (0.3-0.6 g/m3), and droplet size (median volumetric diameter of 15-40 μm). Current strategies to remove ice are based on active technologies such as pneumatic boots, heated surfaces, and deicing agents (i.e., ethylene- and propylene-based glycols). The latter have potential environmental concerns. A passive approach to mitigate accreting ice that is actively being investigated are protective coatings. An ice mitigating coating could potentially be used as a stand-alone material, but more likely in combination with an active approach. In the latter scenario, potential reduction in power consumption by the active approach may be realized. To determine the ice adhesion strength of impact ice that is representative of the aircraft environment is not a trivial matter. Test methods utilizing slowly formed ice (i.e., freezer ice) do not accurately simulate this environment. Likewise, some testing methodologies involve sample relocation from the icing environment to the test chamber that can result in thermal shock to the sample, thus affecting the results. The Adverse Environment Rotor Test Stand (AERTS) located at Pennsylvania State University (PSU) has been demonstrated to simulate impact icing conditions within the icing envelope for the determination of ice adhesion shear strength (IASS) without removal/relocation of the sample.2 Due to the confidence in results obtained from AERTS, this instrument is in high demand and requires a significant amount of lead time and capital investment to obtain IASS results. As a solution for quickly and economically screening coatings in a controlled manner under impact icing conditions, a laboratory-scale ice adhesion test and dead blades were then removed from the rotor/blade assembly to obtain the final mass. The IASS of the live blade was determined from the difference in mass (before and after testing) of the live and dead blades, the ice shed area, and the rpm of the shed event. The same live blade sample was tested in triplicate at all three test temperatures. Surface roughness was determined using a Bruker Dektak XT Stylus Profilometer. Measurements were conducted using a 12.5 μm tip at a vertical range of 65.5 μm with an applied force of 3 mg. Data were collected over a 1.0 mm length at a resolution of 0.056 μm/point. Five single line scans at different locations were collected and processed using a two-point leveling subtraction. The resultant Ra (arithmetic roughness) and Rq (root mean square roughness) average values were calculated.

Smith, Joseph G., Jr.↗

Large-scale static investigation of circulation-control-wing concepts applied to upper surface-blowing aircraft

The use of a circulation control to deflect turbofan engine thrust beyond 90 deg. has been proven in full-scale static ground tests of the circulation-control-wing/upper-surface-blowing (CCW/USB) concept. This powered high-lift system employs a circular, blown trailing edge to replace the USB mechanical flaps to entrain engine-exhaust flow, and to obtain both a vertical-thrust component and an augmented circulation lift for short takeoff and landing (STOL) applications. Previous tests (Phase 1), done in 1982, of a basic configuration installed on the Quiet Short Haul Research Aircraft confirmed these CCW/USB systems capabilities. A second phase (Phase 2) of full-scale, static, thrust-deflection investigations has reconfirmed the ability to deflect engine thrust from 40 to 102 deg., depending on thrust level. Five new configurations were evaluated and performance improvements noted for those configurations with larger blown span, fences or favorable engine interactions, smaller slot height, and larger radii with less than 180 deg. of CCW surface arc. In general, a 90 deg. circular arc with a smaller slot height provided the best performance, demonstrating that adequate thrust turning can be produced by a trailing-edge shape which may have minimal cruise-performance penalty. Thrust deflections were achieved at considerably lower blowing momentum than was required for the baseline case of Phase 1. Improved performance and versatility were thus confirmed for the CCW/USB system applied to STOL aircraft, where the potential for developing a non-moving-parts pneumatic thrust deflector to rapidly vary horizontal force from thrust to drag, while maintaining constant vertical force, appears quite promising. The conversion from high-lift to lower-drag cruise mode by merely terminating the blowing provides an effective STOL aircraft system.

Shovlin, M. D.↗

Solid State Digital Propulsion "Cluster Thrusters" For Small Satellites Using High Performance Electrically Controlled Extinguishable Solid Propellants (ECESP)

Electrically controlled extinguishable solid propellants (ESCSP) are capable of multiple ignitions, extinguishments and throttle control by the application of electrical power. Both core and end burning no moving parts ECESP grains/motors to three inches in diameter have now been tested. Ongoing research has led to a newer family of even higher performance ECESP providing up to 10% higher performance, manufacturing ease, and significantly higher electrical conduction. The high conductivity was not found to be desirable for larger motors; however it is ideal for downward scaling to micro and pico- propulsion applications with a web thickness of less than 0.125 inch/ diameter. As a solid solution propellant, this ECESP is molecularly uniform, having no granular structure. Because of this homogeneity and workable viscosity it can be directly cast into thin layers or vacuum cast into complex geometries. Both coaxial and grain stacks have been demonstrated. Combining individual propellant coaxial grains and/or grain stacks together form three-dimensional arrays yield modular cluster thrusters. Adoption of fabless manufacturing methods and standards from the electronics industry will provide custom, highly reproducible micro-propulsion arrays and clusters at low costs. These stack and cluster thruster designs provide a small footprint saving spacecraft surface area for solar panels and/or experiments. The simplicity of these thrusters will enable their broad use on micro-pico satellites for primary propulsion, ACS and formation flying applications. Larger spacecraft may find uses for ECESP thrusters on extended booms, on-orbit refueling, pneumatic actuators, and gas generators.

Sawka, Wayne N.↗

Anatomical and functional characteristics of carotid sinus stimulation in humans

Transmission characteristics of pneumatic pressure to the carotid sinus were evaluated in 19 subjects at rest and during exercise. Either a percutaneous fluid-filled (n = 12) or balloon-tipped catheter (n = 7) was placed at the carotid bifurcation to record internal transmission of external neck pressure/neck suction (NP/NS). Sustained, 5-s pulses, and rapid ramping pulse protocols (+40 to -80 Torr) were recorded. Transmission of pressure stimuli was less with the fluid-filled catheter compared with that of the balloon-tipped catheter (65% vs. 82% negative pressure, 83% vs. 89% positive pressure; P < 0.05). Anatomical location of the carotid sinus averaged 3.2 cm (left) and 3.6 cm (right) from the gonion of the mandible with a range of 0-7.5 cm. Transmission was not altered by exercise or Valsalva maneuver, but did vary depending on the position of the carotid sinus locus beneath the sealed chamber. These data indicate that transmission of external NP/NS was higher than previously recorded in humans, and anatomical variation of carotid sinus location and equipment design can affect transmission results.

Randomized Controlled Trial↗

Propellant-Flow-Actuated Rocket Engine Igniter

A rocket engine igniter has been created that uses a pneumatically driven hammer that, by specialized geometry, is induced into an oscillatory state that can be used to either repeatedly impact a piezoelectric crystal with sufficient force to generate a spark capable of initiating combustion, or can be used with any other system capable of generating a spark from direct oscillatory motion. This innovation uses the energy of flowing gaseous propellant, which by means of pressure differentials and kinetic motion, causes a hammer object to oscillate. The concept works by mass flows being induced through orifices on both sides of a cylindrical tube with one or more vent paths. As the mass flow enters the chamber, the pressure differential is caused because the hammer object is supplied with flow on one side and the other side is opened with access to the vent path. The object then crosses the vent opening and begins to slow because the pressure differential across the ball reverses due to the geometry in the tube. Eventually, the object stops because of the increasing pressure differential on the object until all of the kinetic energy has been transferred to the gas via compression. This is the point where the object reverses direction because of the pressure differential. This behavior excites a piezoelectric crystal via direct impact from the hammer object. The hammer strikes a piezoelectric crystal, then reverses direction, and the resultant high voltage created from the crystal is transferred via an electrode to a spark gap in the ignition zone, thereby providing a spark to ignite the engine. Magnets, or other retention methods, might be employed to favorably position the hammer object prior to start, but are not necessary to maintain the oscillatory behavior. Various manifestations of the igniter have been developed and tested to improve device efficiency, and some improved designs are capable of operation at gas flow rates of a fraction of a gram per second (0.001 lb/s) and pressure drops on the order of 30 to 50 kilopascal (a few psi). An analytical model has been created and tested in conjunction with a precisely calibrated reference model. The analytical model accurately captures the overall behavior of this innovation. The model is a simple "volume-orifice" concept, with each chamber considered a single temperature and pressure "node" connected to adjacent nodes, or to vent paths through flow control orifices. Mass and energy balances are applied to each node, with gas flow predicted using simple compressible flow equations.

Wollen, Mark↗