Search NASA⌕ Search

SEARCH · Search NASA

Results for “PV fields”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Energy Northwest - Horn Rapids Solar and Storage: An Assessment of Battery Technical Performance

Chartered in 1957 as a joint action agency of the state, Energy Northwest (ENW) is a consortium of 27 public utility districts and municipalities across Washington state. ENW takes advantage of economies of scale and shared services to help utilities run their operations more efficiently and at lower cost, to the benefit of more than 1.5 million customers. ENW develops, owns, and operates a diverse mix of electricity generating resources, including hydro, solar, and wind projects – and the Northwest’s only active nuclear energy facility. These projects provide enough reliable, affordable, and environmentally responsible energy to power more than a million homes each year, and that carbon-free electricity is provided at the cost of generation. The agency continually explores new generation projects to meet its members’ needs. In 2017, as part of the second round of funding from the Washington state Clean Energy Fund, the Washington State Department of Commerce granted up to $3 million in matching funds to develop an estimated $6.5 million project that deployed a 4-MW, 20-acre solar generating array of photovoltaic (PV) panels coupled with a 1 MW/5.5 MWh lithium-iron-phosphate battery energy storage system (BESS) in Richland, Washington. The combination of PV and BESS will provide a predictable, renewable generating source and will also serve as a training ground for solar and battery technicians throughout the nation. The City of Richland will purchase the power from the project and utilize the benefits of the energy storage. The project provides Washington state with its first opportunity to integrate a large-scale solar and storage facility into its clean mix of hydro, nuclear, and wind resources. This first-of-its-kind facility combines solar generation with battery storage and technician training. In 2019, Pacific Northwest National Laboratory (PNNL) worked with ENW to assess the integrated PV and BESS in representative use cases that could benefit the City of Richland. Between March and May 2022, extensive testing was conducted, and the results were used to assess the technical performance of the BESS subjected to actual field operations. Both reference performance and use case tests were performed: (A) Reference performance tests assess the general technical capabilities of the BESS, such as energy capacity, round-trip efficiency (RTE), ramp rate, and signal tracking capability. These are the first tests performed (baseline), and they are repeated after use case tests (post cycle). A standardized U.S. Department of Energy (DOE) energy storage performance protocol was used to characterize the BESS, including representative duty cycle profiles, test procedure guidance, and calculation guidance for determining key characteristics. (B) Use case tests examine the performance of the BESS for specific use cases using duty cycles developed by PNNL in collaboration with ENW. Five use cases were selected for testing: 1) demand charge reduction, 2) load shaping, 3) transmission charge reduction, 4) Volt-VAR service, and 5) outage mitigation. The use case duty cycles were developed based on utility and site-specific characteristics in addition to the technical characteristics and physical capabilities of the BESS. Use case tests were performed between the baseline and post cycle tests. This report describes the BESS and its components, presents testing and performance analysis results, and shares key insights and lessons learned from this project. Outcomes of the tests and analyses will help ENW understand the performance of the Horn Rapids BESS in its current state and design appropriate operational strategies for this and other BESSs over the long term.

14 SOLAR ENERGY↗

Diagnosis of PV Cell Antireflective Coating Degradation Resulting From Hot-Humid High-Voltage Potential Aging

Corrosion of the antireflective coating on a photovoltaic cell ("ARc corrosion") has previously been observed in studies using hot-humid test conditions with external high-voltage (HV) bias. This study primarily focuses on known vulnerable legacy aluminum back surface field cells in mini-modules (MiMos) put through comparative stepped stress tests. Each cell type had MiMos at +1500 V, -1500 V, or unbiased ("Voc") potential, which were sequentially subjected to test conditions of 60 degrees C/60% relative humidity (RH) for 96 h, as in International Electrotechnical Commission Technical Specification 62804-1; 70 degrees C/70% RH for 200 h; and 85 degrees C/85% RH for 200 h. Characterizations at each step included visual camera and electroluminescence (EL) imaging, colorimetry, and current-voltage curve tracing. Final characterizations included: Suns-Voc, spatial mapping of external quantum efficiency, high-resolution photoluminescence, EL, and dark lock-in thermography imaging. Forensics were performed on extracted cores, including scanning electron microscopy (SEM) with energy-dispersive X-ray spectroscopy (EDS), X-ray photoelectron spectroscopy, and scanning Auger microscopy (SAM). Forensics were also conducted on MiMos from previous studies that underwent stepped HV aging and separate outdoor aged full-sized modules. ARc corrosion was specifically seen for the glass/encapsulant/cell side of the +1500 V (HV+) stressed MiMos and modules. Appearance, color, and reflectance were the most distinguishing characteristics relative to glass corrosion, gridline corrosion and delamination, and other concurrent degradation modes. SEM/EDS and SAM identified the conversion of silicon nitride to hydrated silica, hydrous silica, or hydrated amorphous silica, which preferentially occurred at the edges and tips of the pyramidal textured cell surface.

14 SOLAR ENERGY↗

Multimode Characterization Approach for Understanding Cell-Level PV Performance and Degradation

Cell-level degradation processes impact the economic viability and large-scale deployment prospects for both established and emerging photovoltaic (PV) technologies. This project addresses the need to develop experimental and device-modeling approaches for studying cell-level degradation processes in photovoltaic (PV) devices using a variety of characterization techniques that provide access to complementary material and device properties. Our results demonstrate that by coupling characterization results with device modeling it is possible to develop comprehensive understanding of processes leading to performance limitations and degradation. This project developed a suite of novel measurement techniques including pulsed-light-bias operando X-ray and photoelectron spectroscopy (popXPS), light-biased scanning microwave impedance microscopy (sMIM), and near-field transport imaging (TI). In addition, operando characterization methodologies and in situ stressing capabilities have been developed and applied for techniques including electron-beam-induced current (EBIC), cathodoluminescence (CL), and Kelvin probe force microscopy (KPFM). Device-physics models were developed and applied to simulate correlative, multi-mode measurements to extract material and device parameters that control performance degradation. These characterization and modeling techniques were applied in a multi-mode approach to probe cell-level degradation mechanisms in Cd(Se,Te) and hybrid perovskite PV devices. Together these efforts contribute to foundational PV degradation science by establishing a framework for understanding PV performance degradation at the cell level and benefit the U.S. PV industry by providing resources in the form of novel experimental capabilities, knowledge gained, and available expertise that can accelerate research and development of improved PV device materials and architectures. The project provided a comprehensive understanding of degradation in baseline Cd(Se,Te) solar cells provided by our collaborators at Colorado State University (CSU). EBIC and CL-based measurements and revealed unusual collection and recombination profiles in these devices, which underwent significant changes with during stressing. KPFM and operando XPS measurements showed that device stressing permanently alters energy-band alignments at the (Mg,Zn)O/Cd(Se,Te) interface, which in turn account for an observed loss in fill factor. Studies on hybrid perovskite devices were hampered to a significant extent by delays related to the pandemic. Nevertheless, a set of hybrid perovskite devices (supplied through an NREL-industry partnership) were stress tested and characterized with techniques including EBIC, sMIM, popXPS/popUPS and optically excited TI. Available results from these measurements informed the device modeling effort and suggest that defects and related band offsets at the C60/LiF/hybrid perovskite interface are the primary source of degradation in these devices.

14 SOLAR ENERGY↗

Simulating Wind-Driven Loading on PV Systems

As PV modules continue to trend toward larger, thinner, and more flexible forms they grow more susceptible to damage from dynamic wind loading. As a result, understanding the impact of wind on PV systems, particularly when mounted on compliant solar-tracking hardware, and identifying robust, stable array layouts and stow strategies is becoming increasingly important for the PV community. We are developing an open-source software package, PVade (PV aerodynamic design engineering), to simulate the cascading fluid-structure interaction that occurs within single-axis, solar-tracking arrays to enable researchers to test hardware, layout, and tracker control changes, leading to enhanced stability and a reduction in wind-driven damage. We will give an overview of the PVade software and present the latest outcomes from our ongoing validation campaign in which we compare time series and statistical structural responses with field data. From there, we will present simulated results from a larger, multi-row array and highlight the effect of varying tracker angles on stability and the differences between positive and negative tilt angles.

fluid↗

A Simulation and Optimization Framework for Managing Wind-Driven Loading on PV Systems

As PV modules continue to trend toward larger, thinner, and more flexible forms they grow more susceptible to damage from dynamic wind loading. As a result, understanding the impact of wind on PV systems, particularly when mounted on solar-tracking hardware, and identifying robust, stable array layouts and stow strategies is becoming increasingly important for the PV community. We are developing an open-source software package, PVade (PV aerodynamic design engineering), to simulate the cascading fluid-structure interaction that occurs within solar-tracking arrays to enable researchers to test hardware, layout, and tracker control changes, leading to enhanced stability and a reduction in wind-driven damage. We will give an overview of the PVade software and present the latest outcomes from our ongoing validation campaign in which we compare statistical structural responses with field data. From there, we will present simulated results from a larger, multi-row array and highlight the effect of varying tracker angles on stability as measured by both acceleration and deformation, focusing on the stability differences between positive and negative tilt angles.

fluid structure interaction↗

Solar Transposition Modeling via Deep Neural Networks With Sky Images

This article presents a notable advance toward the development of a new method of increasing the single-axis tracking photovoltaic (PV) system power output by improving the determination and near-term prediction of the optimum module tilt angle. The tilt angle of the plane receiving the greatest total irradiance changes with Sun position and atmospheric conditions including cloud formation and movement, aerosols, and particulate loading, as well as varying albedo within a module's field of view. In this article, we present a multi-input convolutional neural network that can create a profile of plane-of-array irradiance versus surface tilt angle over a full 180° arc from horizon to horizon. As input, the neural network uses the calculated solar position and clear-sky irradiance values, along with sky images. The target irradiance values are provided by the multiplanar irradiance sensor (MPIS). In order to account for varying irradiance conditions, the MPIS signal is normalized by the theoretical clear-sky global horizontal irradiance. Using this information, the neural network outputs an N -dimensional vector, where N is the number of points to approximate the MPIS curve via Fourier resampling. The output vector of the model is smoothed with a Gaussian kernel to account for error in the downsamping and subsequent upsampling steps, as well as to smooth the unconstrained output of the model. Furthermore, these profiles may be used to perform near-term prediction of angular irradiance, which can then inform the movement of a PV tracker.

42 ENGINEERING↗

Cyber-Secure and Safe Operation of Solar Photovoltaic Power Distribution Systems

Solar photovoltaic (PV)-rich power distribution systems are networked Cyber-Physical Systems (CPS). These are control systems where multiple computing nodes and diverse intelligent agents interact with the physical world in real-time. However, the presence of networked components renders them vulnerable to potential cyber-attacks, cyber-intrusions, and other malicious events. This is because these systems depend on the measurements reported from their heterogeneous sensors. This makes them vulnerable to potential cyber-attacks where malicious agents can compromise the sensors or the communication networks carrying the sensor measurements. This paper proposes a novel methodology for enhancing the cyber-security and cyber-resilient post-attack safe operation of solar PV-rich power distribution systems against potential cyber-attacks through the Dynamic Watermarking (DW), using online system identification. The resiliency of the proposed technique is tested and validated with several attack scenarios on both a lab-scale 3kW grid-connected PV inverter and a Hardware-in-the-Loop (HiL) system. The proposed approach can be applied to other types of power distribution systems to enhance their cyber-secure and cyber-resilient safe operation. This paper thereby contributes to the field of cyber-security of Cyber-Physical Energy Systems (CPES).

Kim, Jaewon↗

Development of Fixtures and Methods to Assess the Durability of Balance of Systems Components

The degradation of photovoltaic (PV) balance of systems (BoS) components is not well studied, but the consequences include offline modules, strings, and inverters; system shutdown; arc faults; and fires. A utility provider experienced a ~30% failure rate in their power transfer chain, originally attributed to branch connectors. Field-failed specimen assemblies were, therefore, examined, consisting of cable connector, branch connector, and discrete fuse components. In this study, unused field-vintage specimens are examined using a benchtop prototype fixture to identify the most influential environmental stressors on BoS components as well as the effect of external mechanical perturbation. The prototype fixture was used to develop a perturbation capability for future use in the combined-accelerated stress testing chamber. The benchtop experiments were also used to develop the in-situ data acquisition of specimen current, voltage, and temperature. A significant increase in operating temperature (~100 °C from ~40 °C) and a different failure mode (arcing at the metal pins rather than overheating of the fuse filament) were observed promptly once periodic mechanical perturbation was applied. The current at failure was decreased from 35 A (measured for static specimens, with failure occurring in the fuses) to 15 A (for tests with mechanical perturbation, with failure at the male/female metal pin connection). After initial examination using X-ray computed tomography, the external plastic was machined away from failed specimens to allow for failure analysis, including the extraction of the internal convolute springs for morphological examination (optical and electron microscopy). Chemical composition analysis included energy-dispersive X-ray spectroscopy, differential scanning calorimetry, and Fourier transform infrared spectroscopy.

14 SOLAR ENERGY↗

High Altitude Electromagnetic Pulse Testing of Photovoltaic Modules

This report details the test setup, process, and results for radiated susceptibility testing of multicrystalline silicon photovoltaic (PV) modules as part of the EMP-Resilient Electric Grid Grand Challenge Laboratory Directed Research and Development (LDRD) project at Sandia National Laboratories. Testing was conducted over October 10-17, 2019, where 8 photovoltaic modules were exposed to E1 transient pulses with peak field levels up to 100 kV/m. Modules were terminated in a resistive load representing connected components. State of health testing conducted via I-V curve tracing of the photovoltaic modules showed no observable loss of device function due to large electric field transients. Differential mode currents were measured on the order of 10's of amps for up to a microsecond following the radiated field pulse. Common mode currents took the form of a damped sinusoid with a maximum peak of 10's to 100's of amps with a resonance near 60 MHz.

14 SOLAR ENERGY↗

Interoperable, Inverter-Based Distributed Energy Resources (DERs) Enable 100% Renewable and Resilient Utility Microgrids

Project overcomes frequency stability and system control issues when operating distribution microgrids in a low inertia, high PV penetration environment without fossil fuel generators. The team implemented a grid-forming inverter and advanced control features at SDG&E's Borrego Springs Microgrid to demonstrate islanding and blackstart using renewable resources. Simulation and emulation in advance of deployment de-risks field operations.

battery energy storage systems↗

Spatiotemporal Modeling of Real World Backsheets Field Survey Data: Hierarchical (Multilevel) Generalized Additive Models

Assessing photovoltaic module backsheet durability is critical to increasing module lifetime. Laboratory-based accelerating testing has recently failed to predict large scale failures of widely adopted polymeric materials. Additionally, there is a growing concern on characterizing the non-uniformity of field exposure. Therefore, data from field surveys are critical to assess the performance of component lifetimes. Using a documented field survey protocol, 19 field surveys were conducted. The focus of this survey strategy is to investigate spatial continuity in degradation modes. By combining field survey data with real-time satellite weather data, stressor / response models have been trained. Generalized additive Models (GAM) model was created to predict the value of degradation based on measured predictors. Two different GAM constructions were testing using different implementations of basis splines. The model includes variables on the environmental stressors of the system and the location of each measurement in the PV mounting structure. The incorporation of hierarchical structure into the models allowed for material specific degradation rates, while maintaining the assumption of a global trend. The model performed well with an adjusted R2 of 0.975 for yellowness index prediction.

backsheet↗

Perovskite Quantum Dot Solar Cells: Mapping Interfacial Energetics for Improving Charge Separation

Colloidal halide perovskite nanocrystals or quantum dots (QDs) show similar defect tolerance as thin film perovskite materials with added nanoscale phenomena. Perovskite QD solar cells have demonstrated efficiencies of 16.6%, greater than that of any other QD material system. While the efficiency lags behind the best thin-film perovskite devices, these solar cells could have advantages over the thin-film versions in terms of processability, phase stability, and high open-circuit voltages. However, some operating principles behind perovskite quantum dot device stacks and the associated electric field properties are still unknown. Here, we characterize the junction structure within perovskite QD solar cells, by exposing functioning cross-sections and using nanometer-scale Kelvin probe force microscopy to offer insight into the selection and performance of charge selective contacts. We also evaluated various solar cell device architectures with different selective contacts to isolate the role of each junction in device performance. We show that in high-performance n-i-p architectures, both electron- and hole-transport layer (HTL) interfaces possess a strong electric field, but in the case of the inverted p-i-n architecture, we find that high interfacial recombination at the HTL/QD junction is responsible for subpar device performance. Perovskite QD and thin film materials can synergistically be combined to offer more design flexibility in PV devices, and here we demonstrate that the interface between perovskite thin films and QDs are relatively benign and amenable for synergistic device design.

14 SOLAR ENERGY↗

Evaluating the Durability of Balance of Systems Components Using Combined-Accelerated Stress Testing

The degradation of photovoltaic (PV) balance of systems (BoS) components is not well-studied, but the consequences include offline modules, strings, and inverters; system shutdown; arc faults; and fires. A utility provider experienced a ~30% failure rate in their power transfer chain, originally attributed to branch connectors. Field-failed specimen assemblies were therefore examined, consisting of cable connector, branch connector, and discrete fuse components. In this study, unused field-vintage specimens are examined using combined-accelerated stress testing (C-AST) to clarify the most influential environmental stressors as well as the effect of external mechanical perturbation. A benchtop prototype fixture was used to develop the perturbation capability for the C-AST chamber. The benchtop experiments were also used to develop the in-situ data acquisition of specimen current, voltage, and temperature. A significant increase in operating temperature (~100 degrees C from ~40 degrees C) and a different failure mode were observed promptly once periodic mechanical perturbation was applied. The current at failure was decreased from 35 A (with failure in the fuses) to 15 A (failure at the male/female metal pin connection). After initial examination using X-ray computed tomography, the external plastic was machined away from failed specimens to allow for failure analysis, including the extraction of the internal convolute springs for morphological examination (optical and electron microscopy).

balance of systems↗

Evaluating the Durability of Balance of Systems Components Using Combined-Accelerated Stress Testing

The degradation of photovoltaic (PV) balance of systems (BoS) components is not well-studied, but the consequences include: offline-modules, -strings, -inverters; system shutdown; arc-faults; and fires. A utility provider experienced a ~30% failure rate in their power transfer chain, attributed to branch connectors. Field-failed specimen assemblies were therefore examined, consisting of cable connector, branch connector and discrete fuse components. Unused field-vintage specimens are presently being examined using combined-accelerated stress testing (C-AST) to clarify the most influential environmental stressors as well as the effect of external mechanical perturbation. A benchtop prototype fixture was used to develop the perturbation capability for C-AST. The benchtop experiments were also used to develop the in-situ data acquisition of specimen: current, voltage, and temperature. A significant increase in operating temperature, ~100 deg C from ~40 deg C, and a different failure mode was observed immediately once periodic mechanical perturbation was applied. The current at failure was decreased from 35 A (with failure occurring in the fuses) to 15 A (failure at the male/female metal pin connection). After initial examination using X-ray computed tomography, the external plastic was machined away from failed specimens to allow failure analysis, including the extraction of the internal convolute springs for morphological examination (optical- and electron-microscopy). Chemical composition analysis included: energy-dispersive X-ray spectroscopy, differential scanning calorimetry, and Fourier transform infrared spectroscopy.

balance of systems↗

Evaluating the Durability of Balance of Systems Components Using Combined-Accelerated Stress Testing

The degradation of photovoltaic (PV) balance of systems (BoS) components is not well-studied, but the consequences include offline modules, strings, and inverters; system shutdown; arc faults; and fires. A utility provider experienced a ~30% failure rate in their power transfer chain, originally attributed to branch connectors. Field-failed specimen assemblies were therefore examined, consisting of cable connector, branch connector, and discrete fuse components. Previous papers and presentations have focused on the development of the test method using a benchtop prototype. This presentation covers the early results of C-AST aging of static and dynamic specimens.

balance of systems↗

Solar Photovoltaics Resilient Fasteners Levelized Cost of Energy (LCOE) Tool

Solar photovoltaics (PV) module fasteners are one of the most common structural failure points on PV systems, particularly in high winds and coastal areas with ocean spray. Some fastener types have been shown to survive these conditions at higher rates than others. The fastener type, material, quantity, and placement all impact performance. Fasteners that fail less often typically have a higher upfront cost, but this investment can pay off in savings from less frequent torque audits (which reduces O&M costs), reduced system damage, and decreased system downtime. We developed an Excel-based tool to evaluate different module fasteners for a PV system - either a new or retrofit project - and compare differences in upfront and outyear costs to determine the expected life cycle costs and simple payback periods of different fastener options. The tool is site-specific, with inputs including system attributes (such as system size, location, price of power) and fastener attributes (such as design, washer type, nut type, use of locking hardware, materials, installation time, and torque audit requirements). A baseline fastener scenario can be compared to up to four proposed fastener scenarios. In addition to presenting expected life cycle cost implications of the different fastener options, the tool produces results showing the reductions in outyear costs needed to offset any initial cost premiums for more reliable fasteners across four categories: preventative O&M, avoided damage, reduced downtime, and reduced insurance premiums. These numbers can serve as decision aids for users when considering fastener options on new or existing projects. This poster will present the tool, methodology, and scenarios using example sites to highlight the tool capabilities and how it can inform different fastener decisions on different projects. Future work includes incorporating lifetime expected damage costs by embedding damage function curves that the authors are developing from field data.

14 SOLAR ENERGY↗

Decay of Electrostatic Force of Dust Particles on Photovoltaic Modules

Photovoltaic (PV) energy yield loss due to solar module soiling has become increasingly important as solar module deployment is now at the hundreds of gigawatts scale and continues to grow rapidly. We have reported on direct measurements-using atomic force microscopy (AFM)-of strong electric-field-induced attraction and adhesion force (Fes) of dust particles onto solar panel that are 1 to 2 orders of magnitude stronger than the van der Waals and water capillary forces, corroborated by observing the increase in system voltage-induced soiling rate. Here, we report another characteristic of Fes on soiling-long lasting or slow decay after turning off the high voltage applied to solar panels. The Fes decay time varies in a wide time range of 1 to 10 hours, depending on two factors: 1) either/both the cell or/and particle were charged with high voltage before the voltages were turned off; and 2) how the cell was connected to the ground after the voltage was turned off-either connected through the power supply electronics, directly connected to the ground, or electrically floated. The Fes decay is understood in terms of 1) net electrical charge dissipations in both particle and cell, 2) thermal disordering of dipole polarization in the module glass dielectrics, and 3) charge redistribution by the electrostatic interaction of particle and module glass. This long-lasting Fes for hours can significantly affect the solar panel soiling after sunset, especially combined with water condensation.

14 SOLAR ENERGY↗

Evaluating the Durability of Balance of Systems Components Using Combined-Accelerated Stress Testing: Preprint

The degradation of photovoltaic (PV) balance of systems (BoS) components is not well-studied, but the consequences include: offline-modules, -strings, -inverters; system shutdown; arc-faults; and fires. A utility provider experienced a ~30% failure rate in their power transfer chain, originally attributed to branch connectors. Field-failed specimen assemblies were therefore examined, consisting of cable connector, branch connector, and discrete fuse components. Unused field-vintage specimens are presently being examined using combined-accelerated stress testing (C-AST) to clarify the most influential environmental stressors as well as the effect of external mechanical perturbation. A benchtop prototype fixture was used to develop the perturbation capability for the C-AST chamber. The benchtop experiments were also used to develop the in-situ data acquisition of specimen: current, voltage, and temperature. A significant increase in operating temperature, ~100 deg C from ~40 deg C, and a different failure mode was observed promptly once periodic mechanical perturbation was applied. The current at failure was decreased from 35 A (with failure in the fuses) to 15 A (failure at the male/female metal pin connection). After initial examination using X-ray computed tomography, the external plastic was machined away from failed specimens to allow failure analysis, including the extraction of the internal convolute springs for morphological examination (optical- and electron-microscopy).

balance of systems↗