Search NASA⌕ Search

SEARCH · Search NASA

Results for “Particle beam profile”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Extended Acceleration in Slot Gaps and Pulsar High-Energy Emission

We revise the physics of primary electron acceleration in the "slot gap" (SG) above the pulsar polar caps (PCs), a regime originally proposed by Arons and Scharlemann (1979) in their electrodynamic model of pulsar PCs. We employ the standard definition of the SG as a pair-free space between the last open field lines and the boundary of the pair plasma column which is expected to develop above the bulk of the PC. The rationale for our revision is that the proper treatment of primary acceleration within the pulsar SGs should take into account the effect of the narrow geometry of the gap on the electrodynamics within the gap and also to include the effect of inertial frame dragging on the particle acceleration. We show that the accelerating electric field within the gap, being significantly boosted by the effect of frame dragging, becomes reduced because of the gap geometry by a factor proportional to the square of the SG width. The combination of the effects of frame dragging and geometrical screening in the gap region naturally gives rise to a regime of extended acceleration, that is not limited to favorably curved field lines as in earlier models, and the possibility of multiple-pair production by curvature photons at very high altitudes, up to several stellar radii. We present our estimates of the characteristic SG thickness across the PC, energetics of primaries accelerated within the gap, high-energy bolometric luminosities emitted from the high altitudes in the gaps, and maximum heating luminosities produced by positrons returning from the elevated pair fronts. The estimated theoretical high-energy luminosities are in good agreement with the corresponding empirical relationships for gamma-ray pulsars. We illustrate the results of our modeling of the pair cascades and gamma-ray emission from the high altitudes in the SG for the Crab pulsar. The combination of the frame-dragging field and high-altitude SG emission enables both acceleration at the smaller inclination angles and a larger emission beam, both necessary to produce widely-spaced double-peaked profiles.

White, Nicholas E.↗

Alignment of the straw tracking detectors for the Fermilab Muon $g − 2$ experiment and systematic studies for a muon electric dipole moment measurement

The Fermilab Muon $g-2$ experiment is currently preparing for its fourth data-taking period (Run-4). The experiment-wide effort on the analysis of Run-1 data is nearing completion, with the announcement of the first result expected in the coming months. The final goal of the experiment is to determine the muon magnetic anomaly to a precision of 140 ppb. This level of precision will provide indirect evidence of new physics, if the central value agrees with the previously-measured value of the magnetic anomaly. Essential in reducing the systematic uncertainty, through measurements of the muon beam profile, are the in-vacuum straw tracking detectors. A crucial prerequisite in obtaining accurate distributions of the beam profile is the internal alignment of the tracking detectors, which is described in this thesis. As a result of this position calibration, the tracking efficiency has increased by 3%, while the track quality increased by 4%. This thesis also discusses an additional measurement that will be made using the tracking detectors: a search for an electric dipole moment (EDM) of the muon, through the direct detection of an oscillation in the average vertical angle of the electron from the muon decay. An observation of a muon EDM would be evidencemore » of new physics and would provide a new source of CP violation in the charged lepton sector. Essential in measuring the EDM are accurate and precise estimations of potential non-zero radial and longitudinal magnetic fields, which were estimated using the Run-1 data. In addition, a preliminary analysis using the Run-1 data was undertaken to estimate the available precision for the magnetic anomaly measurement using the tracking detectors.« less

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

N-Type delta Doping of High-Purity Silicon Imaging Arrays

A process for n-type (electron-donor) delta doping has shown promise as a means of modifying back-illuminated image detectors made from n-doped high-purity silicon to enable them to detect high-energy photons (ultraviolet and x-rays) and low-energy charged particles (electrons and ions). This process is applicable to imaging detectors of several types, including charge-coupled devices, hybrid devices, and complementary metal oxide/semiconductor detector arrays. Delta doping is so named because its density-vs.-depth characteristic is reminiscent of the Dirac delta function (impulse function): the dopant is highly concentrated in a very thin layer. Preferably, the dopant is concentrated in one or at most two atomic layers in a crystal plane and, therefore, delta doping is also known as atomic-plane doping. The use of doping to enable detection of high-energy photons and low-energy particles was reported in several prior NASA Tech Briefs articles. As described in more detail in those articles, the main benefit afforded by delta doping of a back-illuminated silicon detector is to eliminate a "dead" layer at the back surface of the silicon wherein high-energy photons and low-energy particles are absorbed without detection. An additional benefit is that the delta-doped layer can serve as a back-side electrical contact. Delta doping of p-type silicon detectors is well established. The development of the present process addresses concerns specific to the delta doping of high-purity silicon detectors, which are typically n-type. The present process involves relatively low temperatures, is fully compatible with other processes used to fabricate the detectors, and does not entail interruption of those processes. Indeed, this process can be the last stage in the fabrication of an imaging detector that has, in all other respects, already been fully processed, including metallized. This process includes molecular-beam epitaxy (MBE) for deposition of three layers, including metallization. The success of the process depends on accurate temperature control, surface treatment, growth of high-quality crystalline silicon, and precise control of thicknesses of layers. MBE affords the necessary nanometer- scale control of the placement of atoms for delta doping. More specifically, the process consists of MBE deposition of a thin silicon buffer layer, the n-type delta doping layer, and a thin silicon cap layer. The n dopant selected for initial experiments was antimony, but other n dopants as (phosphorus or arsenic) could be used. All n-type dopants in silicon tend to surface-segregate during growth, leading to a broadened dopant-concentration- versus-depth profile. In order to keep the profile as narrow as possible, the substrate temperature is held below 300 C during deposition of the silicon cap layer onto the antimony delta layer. The deposition of silicon includes a silicon- surface-preparation step, involving H-termination, that enables the growth of high-quality crystalline silicon at the relatively low temperature with close to full electrical activation of donors in the surface layer.

Blacksberg, Jordana↗

Design and fabrication of a four-rod radio frequency quadrupole with a variable aperture

Radiofrequency quadrupole (RFQ) linear accelerators with variable aperture cell parameters offer an effective means of accelerating high-intensity ion beams exceeding 100 mA and have been implemented in various RFQ designs. However, in a four-rod RFQ, the use of dielectric perturbation methods to measure the voltage distribution behind the rod electrodes is not applicable when implementing variable aperture geometries, because changes in the rod shape influence the electric field at the location of the perturbation element. Therefore, it was necessary to design the rod profile for each cell such that the electric field distribution behind the rods remains unaffected by changes in the aperture. In this study, we present a method to adjust the voltage distribution by modifying the geometry of the rod electrodes according to each cell's aperture parameters. This design approach enables the integration of variable aperture cells into a four-rod RFQ linac, significantly enhancing the achievable beam current. To ensure uniform capacitance and maintain a constant rod-electrode voltage despite variations in the average aperture radius, we developed a systematic method for shaping the rod electrodes. This method was refined using two-dimensional (2D) and three-dimensional (3D) electromagnetic field simulations to optimize the electrode cross-sectional profiles. The fabricated rod electrodes were then installed in a four-rod RFQ, and the electric field distribution was measured using the perturbation method and tuned by adjusting the base plates. As a result, the measured variation of ±1.1 % confirms that this design methodology can produce a sufficiently uniform voltage distribution for high-current beam acceleration. These results demonstrate the practical feasibility of a variable-aperture four-rod RFQ linac.

43 PARTICLE ACCELERATORS↗

Development of an accelerator-based neutron source to prototype Mo-99 production, part I: A liquid LBE windowless target

In this article, Molybdenum-99 (Mo-99)’s decay product, technetium-99 (Tc-99 m), is one of the most critical isotopes for medical diagnostics. To provide U.S. domestic supply of Mo-99 without using high-enriched uranium (HEU), a subcritical uranium target assembly (UTA) is irradiated by an accelerator-based neutron source to create Mo-99 through fission. This study discusses the development of the accelerator-based neutron source. The high-energy electrons from the accelerator irradiate a liquid lead-bismuth eutectic (LBE) target to produce neutrons. Part I of this work focuses on numerical and experimental analysis towards the development of a liquid LBE windowless target. Unlike the existing windowless targets in literature, the current design creates a vertical free surface for a beam to irradiate. First, a hydrodynamic analysis of the LBE windowless target is performed. Simplified analytical calculations are assisted by 2D computational fluid dynamics (CFD) simulations to design the target, with the focus on eliminating recirculation zones and avoiding cavitation. With the optimized geometry, the experimental study is performed to investigate the flow hydrodynamics using liquid LBE. The experiments (1) compare pressure drop in the system to correlation predictions; (2) visualize the free surface liquid LBE flow from the beam view; (3) validate the LBE flow profile using temperature sensitive paint from the side view; and (4) validate the liquid LBE film thickness using gamma densitometer measurements. Second, the power handling capability of the designed windowless target is investigated. The divider plate in the current design is susceptible to overheating due to the thin LBE film in front. As LBE erosion and corrosion is likely to occur at an LBE velocity of 2.0 m/s and temperature above 500 °C, a power limit of 10 kW of beam power was established to prevent this corrosion from occurring, which is calculated by a Nusselt number correlation. The divider plate surface temperature at 10 kW agrees well with the 3D CFD simulation results. Part I demonstrates the fundamental physics in liquid LBE windowless target design and associated testing. A companion paper, Part II will demonstrate how to couple this windowless target into the Mo-99 production system, including an accelerator system operating under an ultra-high vacuum and the UTA cooled by water at room temperature.

43 PARTICLE ACCELERATORS↗

Simulations Supporting the Development of Northstar's Indirect Beam Parameters Monitoring System

NorthStar Medical Radioisotopes, LLC is planning to produce the important medical radioisotope molybdenum-99 (Mo-99), the parent of technetium-99m (Tc-99m), through photonuclear reactions in molybdenum-100 (Mo-100). In this approach, a target comprising multiple thin disks of enriched molybdenum metal is bombarded with a 40-MeV electron beam. Electrons impinged on the molybdenum target produce bremsstrahlung X-rays that cause the nuclear reaction. Because enriched Mo-100 is expensive, there is a desire to utilize as much beam power as possible to achieve maximum production yield and minimize the size of the target. This requirement leads to very high beam power density (and heat deposition in the target), which creates challenging requirements for the cooling of the target. The critical part of the target is the target window. It separates the high-pressure helium cooled target from the vacuum beamline and the subject of structural and thermal stress. The temperature of the target window is proportional to the energy density deposited by the beam, so it is critical to maintain the desired beam profile on the target window. The feasibility of indirectly monitoring the maximum energy density of the beam on the beam window through beam losses at the main collimator (Collimator) before the production target was verified. A model of the NorthStar beam transport line was constructed for this purpose using MAD-X and Tao/Bmad codes. Beam optics were computed for the standard operational scenario, followed by an investigation involving approximately 400 cases with parameter variations in the last tuning quadrupoles. This was done to assess the correlation between losses in the collimator and the peak energy density on the target. We developed a model to explore the potential application of Optical transition radiation (OTR) for controlling beam parameters in the NorthStar beam delivery system. This model was based on a generic formula derived from the fundamental solution of the inhomogeneous wave equation of the vector potential, and allowed us to consider various surfaces, even those with irregular or random features, using numerical integration. We applied the model to OTR generated by relativistic electrons impacting an Inconel® 718 beam window. We examined cases with different levels of the window’s surface roughness, ranging from 0.5 to 3.0 microns of root square mean (RMS) deviation. The results of the OTR simulations provided distributions of OTR photons that can be used to study the limitations of optical systems for controlling beam parameters.

43 PARTICLE ACCELERATORS↗

νBDX: a Coherent Elastic Neutrino Nucleus Scattering (CEνNS) experiment at Jefferson Lab

Particle physics is an ever-changing field seeking to explain phenomena that lie at the limits of our current knowledge. Among discovered and hypothesized interactions, Coherent Elastic Neutrino-Nucleus Scattering (CE?NS) stands out as a fascinating and elusive phenomenon, offering a unique window into the nature of neutrinos and their interactions with matter. CE?NS, a process predicted by the Standard Model, represents one of the subtle ways in which neutrinos can interact with atomic nuclei. Unlike other neutrinonucleus interactions, CE?NS occurs coherently, meaning that the entire nucleus collectively responds to the neutrino-mediated weak force, resulting in small energy transfers to the nucleus as a whole. The extremely rare nature of CE?NS events presents a formidable challenge to experimenters seeking to detect and study these interactions. Recent advances in detector technologies and the implementation of large-scale experiments, such as coherent neutrino scattering experiments at research facilities around the world, have opened up new avenues for exploring this elusive phenomenon. These experiments aim not only to observe CE?NS directly but also to extract valuable information on neutrino properties, nuclear structure, and potential deviations from the Standard Model. This thesis aims to study the feasibility of an experiment to study CE?NS at The Thomas Jefferson National Accelerator Facility, Newport News, VA, USA. This would be an experiment that exploits the production of neutrinos by an electron beam dumped on a thick target (the beam dump). The large quantity of neutrinos produced and their energy profile are well suited to the purpose of studying the CE?NS. In my thesis, I will start from previous studies on CE?NS and from theoretical considerations regarding the process, then quantify the expected events for a hypothetical experiment and possible backgrounds through simulations aimed at optimizing the geometry of the future detector. I will also show some tests on selected detector components that will be part of a first prototype.

Grazzi, Stefano↗

A development of wide dynamic-range halo monitor for 8 GeV proton beams at FNAL

The FNAL accelerator complex has been upgrading in increasing beam intensity and beam quality. A new beam halo diagnostic device is required in the beam transport line between booster and Recycler. For this purpose, it was decided to introduce the wide dynamic range monitor technique that was developed in 2012 and has been in operation at the J-PARC beam transport line. The device is a two-dimensional beam profile monitor, and it has a dynamic range of approximately six digits of magnitude by using of Optical Transition Radiation and fluorescence screens. Eliminating harmful beam halos is the most important technique for high-intensity proton accelerators. Therefore, beam halo diagnosis is indispensable and becomes more and more important. New FNAL device has been manufactured in a collaboration between J-PARC and FNAL as a part of U.S.-Japan Science and Technology Cooperation Program in High Energy Physics. The equipment will be manufactured at J-PARC and will be shipped to FNAL in 2025.We designed the device to satisfy FNAL specifications: the beam energy, intensity, and size. Currently, most of the equipments are under construction. The large-aperture optical system has been completed and its optical characteristics are being evaluated at J-PARC. We have been also investigating measurement methods corresponding to FNAL bunch trains. This paper reports on the current status of these developments.

43 PARTICLE ACCELERATORS↗

Report on the DANCE/FP14 Beam Profile and plans for the CY23 LANSCE run cycle

During the beam outage at the beginning of calendar year 2022, the Lujan Center Spallation Target was replaced with the Mark-IV design. Most notably, this included a rotated tungsten disk (for neutron production) in the direct line of sight of the upper tier flight-paths (FPs 12-15), which include DANCE, DICER, and the general-purpose flight path 12, all focused on nuclear physics measurements. This change was made in order to significantly improve both the neutron flux and the time-of-flight resolution for neutrons above 1 keV. Details of the design and motivation can be found in Zavorka et al. 2018. Due to the changes in the spallation target, significant work was required to provide new shutters and shielding for the upper tier flight paths. While the planned beam deliver was for September of 2022, because of delays in the installation process, first beam to DANCE was received the afternoon of 22 Nov 2022. Due to accelerator reliability issues, a total of only 18 days of beam were available for the run cycle. Approximately 90 days of development were planned for understanding the neutronic proper<es of the new spallation target. Most of this work could not be completed. Two measurements were completed, of which one will be discussed here.

43 PARTICLE ACCELERATORS↗

Paraxial, Thin-Lens Analysis of Fixed-Tune, Non-Scaling FFAs with Two Magnets per Cell

Fixed-field accelerators (FFAs) have closed orbits that change as a function of beam momentum. It is sometimes useful to avoid various resonances by keeping the tunes constant as these orbits change. A well-known example is the scaling FFA where the entire beam orbit and optics are geometrically scaled as a function of momentum. However, this is stricter than necessary: cells with three or more lenses can have fixed tunes even when the focussing strengths in the lenses change. Recently, Dejan Trbojevic has found a pair of nonlinear magnets that produce fixed tunes and fixed beta functions while not being a scaling FFA. This improves on a more approximate solution in. Notably a scaling FFA would require one magnet to be entirely reverse-bending, whereas the Trbojevic solution does not do this and instead resembles an intermediate point between the traditional scaling field profiles and the nonscaling profiles centred around a momentum with equal and positive fields. This suggests there are at least three levels of stringency that one can apply to a fixed-tune FFA design: 1. Fixed cell tunes (in both planes) as a function of momentum; 2. Fixed optics (beta functions) as a function of momentum; 3. Similarity of all orbits via a scaling symmetry law ↔ traditional scaling FFA. This note studies the interesting case #2 above (#3 being fully characterised by the orbit at a single energy) in the simplest possible example: a cell of two thin lenses in the small angle (paraxial) approximation.

43 PARTICLE ACCELERATORS↗

Evaluation of the response to electrons and pions in the scintillating fiber and lead calorimeter for the future electron-ion collider

The performance of the Baby Barrel Electromagnetic Calorimeter (Baby BCAL) — a small-scale lead-scintillating-fiber (Pb/ScFi) prototype of the GlueX Barrel Electromagnetic Calorimeter (BCAL) — was tested in a dedicated beam campaign at the Fermilab Test Beam Facility (FTBF). This study provides a benchmark for the Pb/ScFi component of the future Barrel Imaging Calorimeter (BIC) in the ePIC detector at the Electron-Ion Collider (EIC). The detector response to electrons and pions was studied at beam energies between 4 and 10 GeV, extending previous GlueX tests to a higher energy regime. The calibrated detector exhibits good linearity within uncertainties, and its electron energy resolution meets EIC requirements. The data further constrain the constant term in the energy resolution to below 1.9%, improving upon previous constraints at lower energies. Simulations reproduce key features of the electron and pion data within the limitations of the collected dataset and the FTBF test environment. Electron-pion separation in the test beam setup was analyzed using multiple methods, incorporating varying degrees of beam-related effects. The inclusion of longitudinal shower profile information enhanced the separation performance, underscoring its relevance for the full-scale BIC in ePIC. These results provide essential benchmarks for the Pb/ScFi section of the future BIC, validating detector simulations and guiding optimization strategies for electron-pion discrimination.

47 OTHER INSTRUMENTATION↗

Suppression of toroidal Alfvén eigenmodes by the electron cyclotron current drive in KSTAR plasmas

Advanced operation scenarios such as high poloidal beta ( β P ) or high q min are promising concepts to achieve the steady-state high-performance fusion plasmas. However, those scenarios are prone to substantial Alfvénic activity, causing fast-ion transport and losses. Recent experiments with the advanced operation scenario on KSTAR tokamak have shown that the electron cyclotron current drive (ECCD) is able to mitigate and suppress the beam-ion driven toroidal Alfvén eigenmodes (TAEs) for over several tens of global energy confinement time. Co-current directional intermediate off-axis ECCD lowers the central safety factor slightly and tilts the central q -profile shape so that the continuum damping in the core region increases. Besides, the rise of central plasma pressure and increased thermal-ion Landau damping contribute to TAE stabilization. While the TAEs are suppressed, neutron emission rate and total stored energy increase by approximately 45% and 25%, respectively. Fast-ion transport estimated by TRANSP calculations approaches the classical level during the TAE suppression period. Substantial reduction in fast-ion loss and neutron deficit is also observed. Subsequently, enhancement of fast-ion confinement by suppressing the TAEs leads to an increase of non-inductive current fraction and will benefit the sustainment of the long-pulse high-performance discharges.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Beyond PID Controllers: PPO with Neuralized PID Policy for Proton Beam Intensity Control in Mu2e

We introduce a novel Proximal Policy Optimization (PPO) algorithm aimed at addressing the challenge of maintaining a uniform proton beam intensity delivery in the Muon to Electron Conversion Experiment (Mu2e) at Fermi National Accelerator Laboratory (Fermilab). Our primary objective is to regulate the spill process to ensure a consistent intensity profile, with the ultimate goal of creating an automated controller capable of providing real-time feedback and calibration of the Spill Regulation System (SRS) parameters on a millisecond timescale. We treat the Mu2e accelerator system as a Markov Decision Process suitable for Reinforcement Learning (RL), utilizing PPO to reduce bias and enhance training stability. A key innovation in our approach is the integration of a neuralized Proportional-Integral-Derivative (PID) controller into the policy function, resulting in a significant improvement in the Spill Duty Factor (SDF) by 13.6%, surpassing the performance of the current PID controller baseline by an additional 1.6%. This paper presents the preliminary offline results based on a differentiable simulator of the Mu2e accelerator. It paves the groundwork for real-time implementations and applications, representing a crucial step towards automated proton beam intensity control for the Mu2e experiment.

43 PARTICLE ACCELERATORS↗

Laser beam pointing stabilization using analog position-sensitive diodes

Laser wire scanners have been used for ion beam profile and emittance measurements at the Spallation Neutron Source linear accelerator. Due to propagation distances exceeding 100 m, reliable measurements require laser beam stabilization, previously accomplished with a feedback control loop using a digital camera as a position sensor [Hardin et al., Opt. Express 19, 2874 (2011)]. Here, this paper presents an upgraded pointing stabilization system utilizing analog position-sensitive diodes (PSDs) as the position detector, optimized with an optical diffuser. The new system significantly surpasses the previous system by offering an order-of-magnitude improvement in radiation tolerance and a bandwidth limited only by the burst repetition rate of the laser beam. Operating with a 60-Hz burst mode laser, the new system effectively suppresses laser beam drifts up to 30 Hz, compared to the previous system’s 4 Hz limit. In addition, the amplitude of spectral components below 0.1 Hz was reduced by a factor of more than 100, which is over seven times greater than was achieved by the previous system.

Data acquisition↗

Sensor for Monitoring Nanodevice-Fabrication Plasmas

The term plasma process diagnostics (PPD) refers to a spectroscopic technique and sensing hardware that have been proposed for monitoring plasma processes used to fabricate electronic devices that feature sizes as small as several nanometers. Nanometer dimensions are characteristic of the quantum level of miniaturization, where single impurity atoms or molecules can drastically change the local properties of the nanostructures. Such changes may be purposely used in nanoscale design but may also be extremely damaging or cause improper operation of the fabricated devices. Determination of temperature and densities of reactants near the developing features is important, since the structural synthesis is affected by characteristics of the local microenvironment. Consequently, sensors capable of nonintrusive monitoring with high sensitivity and high resolution are essential for real-time atomistic control of reaction kinetics and minimizing trace contamination in plasma processes used to fabricate electronic nanodevices. Such process-monitoring sensors are required to be compact, multiparametric, and immune to the harsh environments of processing plasmas. PPD is intended to satisfy these requirements. The specific technique used to implement plasma diagnostics with a PPD sensor would be an advanced version of continuous-wave cavity-ringdown spectroscopy (CW-CRDS) capable of profiling spectral line broadenings in order to derive both Doppler and Stark components. CRDS is based on measurements of the rate of absorption of laser light in an optical resonator. The ultimate sensitivity results from a very long absorption path length within the cavity and immunity to variations in incident laser intensity. The proposed version of this technique would involve the use of multiplexing tunable laser diodes and an actively modulated high-reflectivity optical resonator, thus offering a synergistic combination of simplicity, compactness, high sensitivity, and high resolution. The multiplexing capabilities of diode lasers could be utilized to make the PPD sensor a single, simple, compact, and inexpensive tool for the acquisition of multiparametric data. A PPD sensor would be capable of continuous measurement of such physical parameters as gas temperature, gas velocity, electron number density, and absolute densities of reacting chemical species. A laser beam can be easily adjusted to analyze the immediate vicinity of the growing nanostructures (or features etched down) in real time. The absorption enhancement in an optical cavity would afford the sensitivity needed for measurement of the temperature and densities of species at concentrations significantly lower than measurable by other nonintrusive techniques. It is anticipated that fully developed PPD sensors would enable simultaneous measurement of local temperature and determination of plasma species responsible for the synthesis and functionalization of nanodevices. These sensors would also enable tracking the pathways and origins of damaging contaminants, thereby providing feedback for adjustment of processes to optimize them and reduce contamination. The PPD sensors should also be useful for optimization of conventional microelectronics manufacturing plasma processes. Going beyond plasma processes for fabrication of electronic devices, PPD sensors could be used for monitoring of atoms, molecules, ions, radicals, clusters, and particles in a variety of other settings, including outer space. Because of their high sensitivity, such sensors could also prove useful for detecting traces of illegal drugs and explosives.

Bolshakov, Alexander↗

Investigation on laser absorption and x-ray radiation in microstructured titanium targets heated by short-pulse relativistic laser pulses

The enhancement effect of a microstructured surface on laser absorption and characteristic K α emission has been investigated by measuring K-shell emission from titanium (Ti) targets irradiated with high-intensity ( ∼ 10 20 W cm − 2 ), subpicosecond (500 fs) laser pulses. The experimental results indicate a modest enhancement ( 1.6 × ) of K α emission from microstructured targets compared to flat foils, but with a similar intensity and profile of He α and Li-like satellites. Particle-in-cell (PIC) simulations are implemented to further understand the underlying physical processes in the laser interaction with both targets, interpreting the mechanisms responsible for the K α enhancement. The reasons for the lower-than-expected enhancement of K α emission are discussed. The rapid heating of the bulk plasma might result in the premature shutdown of K α emission before the thermalization of hot electrons or even the end of laser pulses, suggesting that the use of K α emission as a diagnostic of the hot-electron yield or relaxation could lead to a misinterpretation. Published by the American Physical Society 2024

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Constraints On the Emission Geometries and Spin Evolution Of Gamma-Ray Millisecond Pulsars

Millisecond pulsars (MSPs) are a growing class of gamma-ray emitters. Pulsed gamma-ray signals have been detected from more than 40 MSPs with the Fermi Large Area Telescope (LAT). The wider radio beams and more compact magnetospheres of MSPs enable studies of emission geometries over a broader range of phase space than non-recycled radio-loud gamma-ray pulsars. We have modeled the gamma-ray light curves of 40 LAT-detected MSPs using geometric emission models assuming a vacuum retarded-dipole magnetic field. We modeled the radio profiles using a single-altitude hollow-cone beam, with a core component when indicated by polarimetry; however, for MSPs with gamma-ray and radio light curve peaks occurring at nearly the same rotational phase, we assume that the radio emission is co-located with the gamma rays and caustic in nature. The best-fit parameters and confidence intervals are determined using amaximum likelihood technique.We divide the light curves into three model classes, with gamma-ray peaks trailing (Class I), aligned (Class II), or leading (Class III) the radio peaks. Outer gap and slot gap (two-pole caustic) models best fit roughly equal numbers of Class I and II, while Class III are exclusively fit with pair-starved polar cap models. Distinguishing between the model classes based on typical derived parameters is difficult. We explore the evolution of the magnetic inclination angle with period and spin-down power, finding possible correlations. While the presence of significant off-peak emission can often be used as a discriminator between outer gap and slot gap models, a hybrid model may be needed.

pulsars: general↗

Rapid Demonstration of Bremsstrahlung Diode Optimization

Optimization of the radiation pattern from a Bremsstrahlung target for a given application is possible by controlling the electron beam that impacts the high-atomic-number target. In this work, the electron beam is generated by a 13MV vacuum diode that terminates a coaxial magnetically insulted transmission line (MITL) on the HERMES-III machine at Sandia National Labs. Work by Sanford introduced a geometry for vacuum diodes that can control the flow within bounds. The "indented anode", as coined by Sanford, can straighten out the electron beam in a high-current diode that would otherwise be prone to beam pinching. A straighter beam will produce a more forwardly directed radiation pattern while a pinching electron beam will yield a focal point or hot spot on axis and a more diffuse radiation pattern. Either one of these may be desirable depending on the application. This work serves as a first attempt to optimize the radiation pattern in the former sense of collimating the radiation pattern given a limited parameter space. The optimization is attempted first using electromagnetic particle-in-cell simulations in the EMPIRE code suite. The setup of the models used in EMPIRE is discussed along with some basic theory behind some of the models used in the simulations such as anode heating and secondary ions. Theoretical work performed by Allen Garner and his students at Purdue is included here, which concerns the impact of collisions in these vacuum diodes. The EMPIRE simulations consider both an aggressive and a conservative design. The aggressive design is inherently riskier while the conservative design is chosen as something that, while still a risk, is more likely to perform as expected. The ultimate goal of this work was to validate the EMPIRE code results with experimental data. While the experiment that tested the diode designs proposed by the simulation results fell outside of the fiscal boundaries of this project (and for that reason the results of which are not included in this report), the hardware for the experiment was designed and drafted within those same fiscal boundaries, and is thus included in this report. However, there was yet another experiment performed in this project that tested a key feature of the diode: the hemispherical cathode. Those results are documented here as well, which show that the cathode tip is an important aspect to controlling the diode flow. A short series of simulations on this diode were also performed after the experiment in order to gain a better understanding of the effect of ions. on the flow pattern and faceplate dose profile.

43 PARTICLE ACCELERATORS↗