Search NASA⌕ Search

SEARCH · Search NASA

Results for “Performance Deviation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Hydrogen Activation by Silica Supported Metal Ion Catalysts: Catalytic Properties of Metals and Performance of DFT Functionals

Single-site heterogeneous catalysts (SSHC) have received increasing attention due to their well-defined active sites and potentially high specific activity. Detailed computational studies were carried out on a set of potential SSHC’s, i.e., silica-supported metal ions, to investigate the reactivity of these catalysts with H2 as well as to evaluate the performance of density functional theory (DFT) methods in conjunction with triple-ζ quality basis sets (i.e., cc-pVTZ) on reaction energetics. The ions considered include 4d and 5d metals as well as several post-transition metal ions. A representative cluster model of silica is used to calculate reaction free energies of the metal hydride formation that results from the heterolytic cleavage of H2 on the M–O bond. The hydride formation free energy is previously shown to be strongly correlated with the catalytic activity of such catalysts for alkene hydrogenation. ONIOM calculations (CCSD(T)//MP2) are used to assess the accuracy and reliability of the MP2 results and it is found that MP2 is a suitable level of theory for gauging the performance of DFT functionals. The performance of various DFT functionals is assessed relative to MP2 results and it is found that the wB97xd and PBE0 functionals have the lowest standard deviation (STD) value while the MN12SX and PBE functionals have the lowest mean absolute deviation (MAD) values. The B3LYP functional is shown to have similar MAD and STD values as the top performing functionals. Potential active SSHC’s for exergonic hydrogen activation predicted in this study include mostly late and post transition metal ions, i.e., Au3+, Pd2+, Pt4+, Pd4+, Ir4+, Hg2+, Rh3+, Pb4+, Tl3+, In3+, Ir3+, Os4+, Cd2+, Ru2+, and Ga3+. This study provides important guidance to future computational studies of such catalyst systems.

Plascencia, Cesar↗

Metal nano-grids for transparent conduction in solar cells

A general procedure for predicting metal grid performance in solar cells was developed. Unlike transparent conducting oxides (TCOs) or other homogeneous films, metal grids induce more resistance in the neighbor layer. The resulting balance of transmittance, neighbor and grid resistance was explored in light of cheap lithography advances that have enabled metal nano-grid (MNG) fabrication. The patterned MNGs have junction resistances and degradation rates that are more favorable than solution-synthesized metal nanowires. Neighbor series resistance was simulated by the finite element method, although a simpler analytical model was sufficient in most cases. Finite-difference frequency-domain transmittance simulations were performed for MNGs with minimum wire width (w) of 50 nm, but deviations from aperture transmittance were small in magnitude. Depending on the process, MNGs can exhibit increased series resistance as w is decreased. However, numerous experimental reports have already achieved transmittance-MNG sheet resistance trade-offs comparable to TCOs. The transmittance, neighbor and MNG series resistances were used to parameterize a grid fill factor for a solar cell. In conclusion, this new figure of merit was used to demonstrate that although MNGs have only been employed in low efficiency solar cells, substantial gains in performance are predicted for decreased w in all high efficiency absorber technologies.

14 SOLAR ENERGY↗

Improving computational efficiency of Monte Carlo simulations with variance reduction

CCFE perform Monte-Carlo transport simulations on large and complex tokamak models such as ITER. Such simulations are challenging since streaming and deep penetration effects are equally important. In order to make such simulations tractable, both variance reduction (VR) techniques and parallel computing are used. It has been found that the application of VR techniques in such models significantly reduces the efficiency of parallel computation due to 'long histories'. VR in MCNP can be accomplished using energy-dependent weight windows. The weight window represents an 'average behaviour' of particles, and large deviations in the arriving weight of a particle give rise to extreme amounts of splitting being performed and a long history. When running on parallel clusters, a long history can have a detrimental effect on the parallel efficiency - if one process is computing the long history, the other CPUs complete their batch of histories and wait idle. Furthermore some long histories have been found to be effectively intractable. To combat this effect, CCFE has developed an adaptation of MCNP which dynamically adjusts the WW where a large weight deviation is encountered. The method effectively 'de-optimises' the WW, reducing the VR performance but this is offset by a significant increase in parallel efficiency. Testing with a simple geometry has shown the method does not bias the result. This 'long history method' has enabled CCFE to significantly improve the performance of MCNP calculations for ITER on parallel clusters, and will be beneficial for any geometry combining streaming and deep penetration effects. (authors)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

New insights into the shock tube ignition of H 2 /O 2 at low to moderate temperatures using high-speed end-wall imaging

In this study, the effects of pre-ignition energy releases on H 2 —O 2 mixtures were explored in a shock tube with the aid of high-speed imaging and conventional pressure and emission diagnostics. Ignition delay times and time-resolved camera image sequences were taken behind the reflected shockwaves for two hydrogen mixtures. High concentration experiments spanned temperatures between 858 and 1035 K and pressures between 2.74 and 3.91 atm for a 15% H 2 \18% O 2 \Ar mixture. Low concentration data were also taken at temperatures between 960 and 1131 K and pressures between 3.09 and 5.44 atm for a 4% H 2 \2% O 2 \Ar mixture. These two model mixtures were chosen as they were the focus of recent shock tube work conducted in the literature. Experiments were performed in both a clean and dirty shock tube facility; however, no deviations in ignition delay times between the two types of tests were apparent. The high-concentration mixture (15%H 2 \18%O 2 \Ar) experienced energy releases in the form of deflagration flames followed by local detonations at temperatures < 1000 K. Measured ignition delay times were compared to predictions by three chemical kinetic mechanisms: GRI-Mech 3.0, AramcoMech 2.0, and Burke's et al. (2012) mechanisms. It was found that when proper thermodynamic assumptions are used, all mechanisms were able to accurately predict the experiments with superior performance from the well-validated AramcoMech 2.0 and Burke et al. mechanisms. Current work provides better guidance in using available literature hydrogen shock tube measurements, which spanned more than 50 years but were conducted without the aid of high-speed visualization of the ignition process, and their modeling using combustion kinetic mechanisms.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Digital tomosynthesis (DTS) for verification of target position in early stage lung cancer patients

Purpose: The ability to verify intrafraction tumor position is clinically useful for hypofractionated treatments. Short arc kV digital tomosynthesis (DTS) could facilitate more frequent target verification. The authors used DTS combined with triangulation to determine the mean temporal position of small-volume lung tumor targets treated with stereotactic radiotherapy. DTS registration results were benchmarked against online clinical localization using registration between free-breathing cone-beam computed tomography (CBCT) and the average intensity projection (AvIP) of the planning 4DCT.Methods: In this retrospective study, 76 sets of kV-projection images from online CBCT scans of 13 patients were used to generate DTS image slices (CB-DTS) with nonclinical research software (DTS Toolkit, Varian Medical Systems). Three-dimensional tumor motion was 1.3–4 mm in six patients and 6.1–25.4 mm in seven patients on 4DCT (significant difference in the mean of the groups, P < 0.01). The 4DCT AvIP was used to digitally reconstruct the Reference-DTS. DTS registration and DTS registration combined with triangulation were investigated. Progressive shortening of total DTS arc lengths from 95° to 35° around 0° gantry position was evaluated for different scenarios: DTS registration using the entire arc; DTS registration plus triangulation using two nonoverlapping arcs; and for 55° and 45° total gantry rotation, DTS registration plus triangulation using two overlapping arcs. Finally, DTS registration plus triangulation performed at eight gantry angles, each separated by 45° was evaluated using full fan kV projection data for one patient with an immobile tumor and five patients with mobile tumors.Results: For DTS registration alone, shortening arc length did not influence accuracy in X- and Y-directions, but in Z-direction, mean deviations from online CBCT localization systematically increased for shorter arc length (P < 0.05). For example, using a 95° arc mean DTS-CBCT difference was 0.8 mm (1 SD = 0.6 mm) and for a 35° arc the mean was 2.4 mm (1 SD = 1.7 mm). DTS plus triangulation using nonoverlapping-arcs increased accuracy in Z-direction for tested arc lengths ≤55° (P < 0.01). Overlapping arcs increased accuracy in Y-direction for tumors with motion >4 mm (P < 0.02) but increased Z-direction accuracy was only observed with 55° total gantry rotation. The 95th percentile deviations with this overlapping technique in X-, Y-, and Z-directions were 1.3, 2.0, and 2.5 mm, respectively. For the five patients with mobile tumors where DTS + triangulation was performed with 45° intervals, the pooled deviation from online CBCT correction showed, for X-, Y-, and Z-directions, mean of 1.1 mm, standard deviations (SD) of 0.9, 1.0, and 0.9 mm, respectively. The mean + 2 SD was <3 mm for each direction.Conclusions: Short-arc DTS verification of time averaged lung tumor position is feasible using free-breathing kV projection data and the AvIP of the 4DCT as a reference. Observed differences between DTS and online CBCT registration with AvIP were ≤3 mm (mean + 2 SD), however, the increased temporal resolution of DTS + triangulation also identified short period deviations from the average target position on the CBCT. Short-arc DTS appears promising for intrafraction tumor position monitoring during stereotactic lung radiotherapy delivered with a rotational technique.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Measurement of the $t\bar{t} t\bar{t}$ production cross section in pp collisions at $ \sqrt{s} $ = 13 TeV with the ATLAS detector

A measurement of four-top-quark production using proton-proton collision data at a centre-of-mass energy of 13 TeV collected by the ATLAS detector at the Large Hadron Collider corresponding to an integrated luminosity of 139 fb -1 is presented. Events are selected if they contain a single lepton (electron or muon) or an opposite-sign lepton pair, in association with multiple jets. The events are categorised according to the number of jets and how likely these are to contain b-hadrons. A multivariate technique is then used to discriminate between signal and background events. The measured four-top-quark production cross section is found to be 26$^{+17}_{-15}$ fb, with a corresponding observed (expected) significance of 1.9 (1.0) standard deviations over the background-only hypothesis. The result is combined with the previous measurement performed by the ATLAS Collaboration in the multilepton final state. The combined four-top-quark production cross section is measured to be 24$^{+7}_{-6}$ fb, with a corresponding observed (expected) signal significance of 4.7 (2.6) standard deviations over the background-only predictions. It is consistent within 2.0 standard deviations with the Standard Model expectation of 12.0 ± 2.4 fb.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

36 Hz integral linewidth laser based on a photonic integrated 4.0 m coil resonator

Laser stabilization sits at the heart of many precision scientific experiments and applications, including quantum information science, metrology, and atomic timekeeping. Many of these systems narrow the laser linewidth and stabilize the carrier by use of Pound–Drever–Hall (PDH) locking to a table-scale, ultrahigh quality factor (Q), vacuum spaced Fabry–Perot reference cavity. Integrating these cavities to bring characteristics of PDH stabilization to the chip scale is critical to reducing their size, cost, and weight, and enabling a wide range of portable and system-on-chip applications. We report a significant advance in integrated laser linewidth narrowing, stabilization, and noise reduction by use of a photonic integrated 4.0 m long coil resonator to stabilize a semiconductor laser. We achieve a 36 Hz 1 / π <#comment/> -integral linewidth, Allan deviation of 1.8 × <#comment/> 10 − <#comment/> 13 at 10 ms measurement time, and a 2.3 kHz/s drift—to the best of our knowledge, the lowest integral linewidth and highest stability demonstrated for an integrated waveguide reference cavity. This performance represents over an order of magnitude improvement in integral linewidth and frequency noise over previous integrated waveguide PDH stabilized reference cavities and bulk-optic and integrated injection locked approaches, and over two orders of magnitude improvement in frequency and phase noise than integrated injection locked approaches. Two different wavelength coil designs are demonstrated, stabilizing lasers at 1550 nm and 1319 nm. The resonator is bus-coupled to a 4.0 m long coil, with a 49 MHz free spectral range, mode volume of 1.0 × <#comment/> 10 10 µ <#comment/> m 3 , and 142 million intrinsic Q , fabricated in a CMOS compatible, ultralow loss silicon nitride waveguide platform. Our measurements and simulations show that the thermorefractive noise floor for this particular cavity is reached for frequencies down to 20 Hz in an ambient environment with simple passive vibration isolation and without vacuum or thermal isolation. The thermorefractive noise limited performance is estimated to yield an 8 Hz 1 / π <#comment/> -integral linewidth and Allan deviation of 5 × <#comment/> 10 − <#comment/> 14 at 10 ms, opening a stability regime that heretofore has been available only in fundamentally non-integrated systems. These results demonstrate the potential to bring the characteristics of laboratory-scale stabilized lasers to the integrated, wafer-scale compatible chip scale, and are of interest for a number of applications in quantum technologies and atomic, molecular, and optical physics, and with further developments below 10 Hz linewidth, can be highly relevant to ultralow noise microwave generation.

Liu, Kaikai (ORCID:0000000213609646)↗

Effect of geometry and operational parameters on the dehumidification performance of a desiccant coated heat exchanger

Solid desiccant dehumidification systems are an alternative to vapor-compression-based air dehumidification systems. They use solid desiccant materials to adsorb air moisture in space cooling. DCHE can integrate the cooling component in the heat exchanger to achieve higher dehumidification capacity. Comprehensive numeric modeling would be necessary to assist in the design and operation of the DCHE under development to achieve maximum performance. Here, we provide the details of a heat and mass transfer model developed for this purpose. The model aims to cover a gap in existing models by independently modeling heat transfer on the solid desiccant, fin, and tube. The model results were compared with an experimental reference for validation. The air outlet humidity and temperature results for dehumidification and regeneration showed a deviation lower than 15% from the experiment. The validated model was used to perform a parametric study for a series of design and operating conditions. The parametric analysis showed that an increase of 25% in desiccant layer thickness and thermal contact resistance between solid elements reduces moisture removal by 9.1% and 1%, respectively. These results indicate the need to independently model the desiccant layer.

42 ENGINEERING↗

Property Variations in Modern REBCO Coated Conductors from Multiple Manufacturers

The complex, multilayer structure of REBCO Coated Conductor (CC) poses significant challenges in the fabrication of high magnetic field devices where large stresses may initiate various forms of damage. Our goal is to peer below the cartoon representations of CC so that, amongst other things, we might better understand whether a CC from one manufacturer is interchangeable with that from another. This involves knowledge of a broad range of electromagnetic, geometric, microstructural, and J c (θ,B,T) properties, and their variations that collectively pose challenges for the fault tolerance of REBCO CC devices. Accordingly, comparative measurements of J c , visualization of flux penetration with Magneto-Optical Imaging (MOI), tape geometry from Scanning Electron Microscopy (SEM) of polished cross-sections, and extensive optical microscopy was performed on recently purchased samples from multiple manufacturers. Our analyses reveal many deviations from or characteristics absent from manufacturers’ specifications, while a comparison of different manufacturers’ mechanically and laser slit tapes shows a diverse array of slitting characteristics amongst the manufacturers and variation in properties those made to the same specification. Laser slit tapes from several manufacturers reveal ablated edges with damaged regions extending up to 50 μm, comparable to the damaged region found in the mechanically slit CC of this study. Overall, the aim of this study is to flesh out appropriate ways to understand the real conductor below the manufacturers’ cartoons to avoid surprises in our REBCO CC coil development program. The goal of this work was to perform a broad array of characterizations of the type needed for validation of purpose for making high field magnets: to our surprise we found a wide range of properties which greatly impact the mechanical strength and electromagnetic performance of solenoids composed of these conductors and reinforced the need for a broad characterization program for each conductor prior to its implementation.

Bradford, G.↗

SU-E-T-54: A New Method for Optimizing Radiation Isocenter for Linac-Based SRS

Purpose: To develop a new method to minimize deviation of linac x-ray beams from the centroid of the volumetric radiation isocenter for all combinations of gantry and table angle. Methods: A set of ball-bearing (Winston-Lutz) images was used to determine the gantry radiation isocenter as the midrange of deviation values. Deviations in the cross-plane direction were minimized by calibration of MLC leaf position offset, and by adjusting beam position steering for each energy. Special attention was also paid to matching the absolute position of isocenter across all energies by adjusting position steering in the gun-target axis. Displacement of table axis from the gantry isocenter, and recommended table axis adjustment for contemporary Elekta linacs, was also determined. Eight images were used to characterize the volumetric isocenter for the full range of gantry and table rotations available. Tabulation of deviation for each beam was used to test compliance with isocenter tolerance. Results: Four contemporary Elekta linacs were evaluated and the radius in the gun-target axis of the radiation isocenter was 0.5 to 0.7 mm. After beam steering adjustment, the radius in the cross-plane direction was typically 0.2 to 0.4 mm. Position matching between energies can be reduced to 0.28 mm. Maximum total deviation was 0.68 to 1.07 mm, depending primarily on the effect of systematic table axis wobble with rotation. Conclusion: This new method effectively facilitates minimization of deviation between beam center and target position. The test, which requires a few minutes to perform, can be easily incorporated into a routine machine QA program. A tighter radiation isocenter for contemporary Elekta linacs would require reducing the effect of gantry arm flex and/or table axis wobble that are the two main components of deviation from the designated isocenter point.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Validation of Gamma Dose Rate Calculation Methodology using the Morris and Turkey Point Measurements

The ability to accurately predict the dose rates from the spent nuclear fuel assembly is very important for determining whether the used nuclear fuel is self-guarded and self-protected. Studies have shown that the direct numerical calculations of the dose rates gave a much lower value than a typical reference. This report summarizes the benchmark studies performed to evaluate the numerical methodologies used in calculating the gamma dose rates of the spent nuclear fuel assemblies. The Morris and Turkey Point experimental data for dose rates measured through air were used in the analyses. Numerical simulations of the gamma dose rate measurements included the fuel depletion analysis of the fuel assembly as well as its structural materials irradiated inside the reactor core, the radioisotopes decay, and photon transport simulations to calculate the gamma dose rates. The different factors which affect the calculated gamma dose rates were addressed. The calculated results were compared with the measured gamma dose rates. Good agreement was obtained when the detectors were placed at the middle of the fuel assembly region. The deviations of the calculated dose rates became larger when the measurements were performed at the top or bottom fuel assemblies. In these benchmark studies, the spent nuclear fuel assemblies were all PWR assemblies and had fuel burnup around 25 MWd/kg to 40 MWd/kg. Its cooling time before the measurements was around 1.8 years to 7 years. The used nuclear fuel assembly is usually self-protected while discharged from the core. Its radioactivity decreases and after a few tens of years it may fall down below the current threshold of 100 r/h. Future validation work is necessary in order to better evaluate the numerically calculated gamma dose rates with experiments performed for other types of fuel assemblies and for fuel assemblies with higher burnup and/or longer cooling times.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Surface Anchoring and Director Distribution in a Grandjean–Cano Wedge

Theoretical calculations of the director distribution in a Grandjean–Cano wedge in relation to the anchoring strength and mutual orientation of the easy axes at the wedge surfaces are performed for various model surface anchoring potentials. Comparison of the theory and experiment allows one to propose the socalled model D-potential, quadratic in angle of director deviation from the easy axes, as the best one in fitting the experiment in the angular range of performed measurements. To satisfy general requirements on the wedge surface, a modified D-potential is proposed. The optimal conditions of the experiment aimed at restoring the potential in the whole range of its definition (in particular, nonparallel orientation of the easy axes at the wedge surfaces) are formulated.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Confidence: Analyzing Performance With Empirical Probabilities

Variability in the performance of shared system components is a major obstacle in analyzing the effective throughput of leadership class computers. Shared file systems and networks are serious impediments to achieving repeatable application performance on HPC systems. In particular, performance analysts are likely to be interested in quantifying differences between average-case behavior, worst-case behavior, and standard deviation for shared system components. Typical descriptions of these statistics assume a normal distribution; however, in non-linear and multi-modal performance distributions, summary statistics are often misleading. In this paper we describe Confidence, a tool for analyzing the full spectrum of performance for a benchmarking code. By including all of the experimental outcomes in the analysis without discarding any measurements, Confidence enables a novel analysis of benchmark performance. Finally, we use Confidence to characterize the network performance of three high performance computer systems, and we provide recommendations for leveraging network performance in latency sensitive applications.

Settlemyer, Bradley W↗

Machine learning pipeline for denoising low signal-to-noise ratio and out-of-distribution transmission electron microscopy datasets

High-resolution transmission electron microscopy (HRTEM) is crucial for observing material’s structural and morphological evolution at Angstrom scales, but the electron beam can alter these processes. Devices such as CMOS-based direct-electron detectors operating in electron-counting mode can be utilized to substantially reduce the electron dosage. However, the resulting images often lead to a low signal-to-noise ratio, which requires frame integration that sacrifices temporal resolution. Several machine learning (ML) models have been recently developed to successfully denoise HRTEM images. Yet, these models are often computationally expensive, and their inference speeds on GPUs are outpaced by the imaging speed of advanced detectors, precluding in situ analysis. Furthermore, the performance of these denoising models on datasets with imaging conditions that deviate from the training datasets has not been evaluated. To mitigate these gaps, we propose a new self-supervised ML denoising pipeline specifically designed for time-series HRTEM images. This pipeline integrates a blind-spot convolution neural network with pre-processing and post-processing steps, including drift correction and low-pass filtering. Results demonstrate that our model outperforms various other ML and non-ML denoising methods in noise reduction and contrast enhancement, leading to improved visual clarity of atomic features. Additionally, the model is drastically faster than U-Net-based ML models and demonstrates excellent out-of-distribution generalization. The model’s computational inference speed is in the order of milliseconds per image, rendering it suitable for application in in-situ HRTEM experiments.

36 MATERIALS SCIENCE↗

THE CARNEGIE-IRVINE GALAXY SURVEY. II. ISOPHOTAL ANALYSIS

The Carnegie-Irvine Galaxy Survey (CGS) is a comprehensive investigation of the physical properties of a complete, representative sample of 605 bright (B{sub T} {<=} 12.9 mag) galaxies in the southern hemisphere. This contribution describes the isophotal analysis of the broadband (BVRI) optical imaging component of the project. We pay close attention to sky subtraction, which is particularly challenging for some of the large galaxies in our sample. Extensive crosschecks with internal and external data confirm that our calibration and sky subtraction techniques are robust with respect to the quoted measurement uncertainties. We present a uniform catalog of one-dimensional radial profiles of surface brightness and geometric parameters, as well as integrated colors and color gradients. Composite profiles highlight the tremendous diversity of brightness distributions found in disk galaxies and their dependence on Hubble type. A significant fraction of S0 and spiral galaxies exhibit non-exponential profiles in their outer regions. We perform Fourier decomposition of the isophotes to quantify non-axisymmetric deviations in the light distribution. We use the geometric parameters, in conjunction with the amplitude and phase of the m = 2 Fourier mode, to identify bars and quantify their size and strength. Spiral arm strengths are characterized using the m = 2 Fourier profiles and structure maps. Finally, we utilize the information encoded in the m = 1 Fourier profiles to measure disk lopsidedness. The databases assembled here and in Paper I lay the foundation for forthcoming scientific applications of CGS.

79 ASTRONOMY AND ASTROPHYSICS↗

First characterisation of the MAGO cavity, a superconducting RF detector for kHz–MHz gravitational waves

Heterodyne detection using microwave cavities is a promising method for detecting high-frequency gravitational waves (GWs) or ultralight axion dark matter. In this work, we report on studies conducted on a spherical 2-cell cavity developed by the MAGO collaboration for high-frequency GWs detection. Although fabricated around 20 years ago, the cavity had not been used since. Due to deviations from the nominal geometry, we conducted a mechanical survey and performed room-temperature plastic tuning. Measurements and simulations of the mechanical resonances and electromagnetic properties were carried out, as these are critical for estimating the cavity’s GW coupling potential. Based on these results, we plan further studies in a cryogenic environment. The cavity characterisation does not only provide valuable experience for a planned physics run but also informs the future development of improved cavity designs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dramatic relativistic effects on the ns dipole angular distribution asymmetry parameter, β ns , of heavy and superheavy elements

A theoretical study of the dipole photoelectron angular distribution asymmetry parameter, β, of the 6s, 5s and 4s subshells has been conducted for a range of closed-shell heavy, Hg (Z = 80), Rn (Z = 86), Ra (Z = 88) and superheavy, No (Z = 102), Cn (Z = 112), Og (Z = 118), Ubn (Z = 120) elements to understand the deviation of β from the nonrelativistic value of 2 owing to relativistic effects. It was found that the deviation, strongest in Cooper minimum regions, persists over all energy for all ns subshells, and the deviations increase with Z. Furthermore, three levels of relativistic calculations were performed in order to pinpoint the particular interactions responsible for the details of the behavior of the ns β's as functions of energy, n, and Z and, in addition to the effects of the (relativistic) spin–orbit interaction, interchannel coupling was found to be of crucial importance in the determination of the β parameter in most of the situations studied.

74 ATOMIC AND MOLECULAR PHYSICS↗

High-sensitivity operation of single-beam optically pumped magnetometer in a kHz frequency range

Here, optically pumped magnetometers (OPM) can be used in various applications, from magnetoencephalography to magnetic resonance imaging and nuclear quadrupole resonance (NQR). OPMs provide high sensitivity and have the significant advantage of non-cryogenic operation. To date, many magnetometers have been demonstrated with sensitivity close to 1 fT, but most devices are not commercialized. Most recently, QuSpin developed a model of OPM that is low cost, high sensitivity, and convenient for users, which operates in a single-beam configuration. Here we developed a theory of single-beam (or parallel two-beam) magnetometers and showed that it is possible to achieve good sensitivity beyond their usual frequency range by tuning the magnetic field. Experimentally we have tested and optimized a QuSpin OPM for operation in the frequency range from DC to 1.7 kHz, and found that the performance was only slightly inferior despite the expected decrease due to deviation from the spin-exchange relaxation-free regime.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗