Search NASA⌕ Search

SEARCH · Search NASA

Results for “Phase reconstruction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

VLTI-MATISSE Chromatic Aperture-Synthesis Imaging of η Carinae’s Stellar Wind Across the Brα Line: Periastron Passage Observations in February 2020

Context: Eta Carinae is a highly eccentric, massive binary system (semimajor axis∼15.5 au) with powerful stellar winds and a phase-dependent wind-wind collision (WWC) zone. The primary star, ηCar A, is a luminous blue variable (LBV); the secondary, η Car B, is a Wolf-Rayet or O star with a faster but less dense wind. Aperture-synthesis imaging allows us to study the mass loss from the enigmatic LBV η Car. Understanding LBVs is a crucial step toward improving our knowledge about massive stars and their evolution. Aims: Our aim is to study the intensity distribution and kinematics of η Car’s WWC zone. Methods: Using the VLTI-MATISSE mid-infrared interferometry instrument, we perform Brα imaging of η Car’s distorted wind. Results: We present the first VLTI-MATISSE aperture-synthesis images of η Car A’s stellar wind in several spectral channels distributed across the Brα 4.052 μm line (spectral resolving power R∼960). Our observations were performed close to periastron passage in February 2020 (orbital phase∼14.0022). The reconstructed iso-velocity images show the dependence of the primary stellar wind on wavelength or line-of-sight (LOS) velocity with a spatial resolution of 6 mas (∼14 au). The radius of the faintest outer wind regions is∼26 mas (∼60 au). At several negative LOS velocities, the primary stellar wind is less extended to the northwest than in other directions. This asymmetry is most likely caused by the WWC. Therefore, we see both the velocity field of the undisturbed primary wind and the WWC cavity. In continuum spectral channels, the primary star wind is more compact than in line channels. A fit of the observed continuum visibilities with the visibilities of a stellar wind CMFGEN model (CMFGEN is an atmosphere code developed to model the spectra of a variety of objects) provides a full width at half maximum fit diameter of the primary stellar wind of 2.84±0.06 mas (6.54±0.14 au). We compare the derived intensity distributions with the CMFGEN stellar wind model and hydrodynamic WWC models.

G Weigelt↗

Conditions Databases at FNAL

Conditions databases is an important class of database applications where the database is used to record the state of a set of quantities as a function of observation time. Conditions databases are used in Hight Energy Physics to record the state of the detector apparatus during data taking, and then to use the data during the event reconstruction and analysis phases. At FNAL, we have a set of 3 different conditions database products, Minerva Conditions DB, ConDB and UConDB, which cover the whole range of the use cases presented by the FNAL experiments. These products have common features such as conditions data representation model, data version control, ability to restore the database to a previous state, scalable web service data access interface. In the paper, we will present the common features of the products, common solutions used to build them and also the differences between the products and their target use cases.

Mandrichenko, Igor V.↗

High resolution x-ray lensless imaging by differential holographic encoding

X-ray free electron lasers (X-FEL{sub s}) will soon offer femtosecond pulses of laterally coherent x-rays with sufficient intensity to record single-shot coherent scattering patterns for nanoscale imaging. Pulse trains created by splitand-delay techniques even open the door for cinematography on unprecedented nanometer length and femtosecond time scales. A key to real space ultrafast motion pictures is fast and reliable inversion of the recorded reciprocal space scattering patterns. Here we for the first time demonstrate in the x-ray regime the power of a novel technique for lensless high resolution imaging, previously suggested by Guizar-Sicairos and Fienup termed holography with extended reference by autocorrelation linear differential operation, HERALD0. We have achieved superior resolution over conventional x-ray Fourier transform holography (FTH) without sacrifices in SNR or significant increase in algorithmic complexity. By combining images obtained from individual sharp features on an extended reference, we further show that the resolution can be even extended beyond the reference fabrication limits. Direct comparison to iterative phase retrieval image reconstruction and images recorded with stateof- the-art zone plate microscopes is presented. Our results demonstrate the power of HERALDO as a favorable candidate for robust inversion of single-shot coherent scattering patterns.

36 MATERIALS SCIENCE↗

Sampling and Reconstruction of the Pupil and Electric Field for Phase Retrieval

This technology is based on sampling considerations for a band-limited function, which has application to optical estimation generally, and to phase retrieval specifically. The analysis begins with the observation that the Fourier transform of an optical aperture function (pupil) can be implemented with minimal aliasing for Q values down to Q = 1. The sampling ratio, Q, is defined as the ratio of the sampling frequency to the band-limited cut-off frequency. The analytical results are given using a 1-d aperture function, and with the electric field defined by the band-limited sinc(x) function. Perfect reconstruction of the Fourier transform (electric field) is derived using the Whittaker-Shannon sampling theorem for 1<Q<2. The Fourier transform is constructed by periodic extension, i.e., by spacing copies of the transform in a definite way, recognizing that no aliasing occurs for values of the sampling ratio such that 1<Q<2, which can be used to advantage in the application of phase retrieval estimation. A method was developed for propagating the electro magnetic field with no aliasing, which has been extended to 2-d optical apertures.

Dean, Bruce↗

Continuous motion scan ptychography: Characterization for increased speed in coherent x-ray imaging

Ptychography is a coherent diffraction imaging (CDI) method for extended objects in which diffraction patterns are acquired sequentially from overlapping coherent illumination spots. The object’s complex transmission function can be reconstructed from those diffraction patterns at a spatial resolution limited only by the scattering strength of the object and the detector geometry. Most experiments to date have positioned the illumination spots on the sample using a move-settle-measure sequence in which the move and settle steps can take longer to complete than the measure step. We describe here the use of a continuous “fly-scan” mode for ptychographic data collection in which the sample is moved continuously, so that the experiment resembles one of integrating the diffraction patterns from multiple probe positions. This allows one to use multiple probe mode reconstruction methods to obtain an image of the object and also of the illumination function. We show in simulations, and in x-ray imaging experiments, some of the characteristics of fly-scan ptychography, including a factor of 25 reduction in the data acquisition time. This approach will become increasingly important as brighter x-ray sources are developed, such as diffraction limited storage rings.

43 PARTICLE ACCELERATORS↗

Doppler coherence imaging and tomography of flows in tokamak plasmas (invited)

This article describes the results of spatial heterodyne Doppler ''coherence imaging'' of carbon ion flows in the divertor region of the DIII-D tokamak. Spatially encoded interferometric projections of doubly ionized carbon emission at 465 nm have been demodulated and tomographically inverted to obtain the spatial distribution of the carbon ion parallel flow and emissivity. The operating principles of the new instruments are described, and the link between measured properties and line integrals of the flow field are established. An iterative simultaneous arithmetic reconstruction procedure is applied to invert the interferometric phase shift projections, and the reconstructed parallel flow field amplitudes are found to be in reasonable agreement with UEDGE modeling.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Statistical and Neural Network for Real Sensor-Data-Driven Anomaly Detection in Nuclear Applications

Anomaly detection (AD) in sensor data is critical to ensure uninterrupted functionality of nuclear power plants (NPPs). Consequently, AD model validation through real-world sensor data is important for applications in nuclear facilities. In this paper, we propose an Autoencoder (AE)—a multi-layered neural network, for AD in sensor data from an operational NPP testbed. Since the dataset lacks labels for irregularities, we introduce random noise and label them to effectively train our model. The proposed AE model assigns a higher reconstruction error to the abnormal samples that deviate from those encountered during the training phase and uses the reconstruction loss to detect anomalies in a representative imbalanced dataset. We also introduce an analytical solution—seasonal trend decomposition (STD)—as another AD scheme for identifying irregularities withinthe same time-series dataset. In contrast to the AE model which relies on reconstruction loss, the STD scheme decomposes the entire dataset into its trend, seasonality, and residual components to pinpoint irregularities. Our findings indicate that the proposed AE and STD models individually achieve recall scores of 97% and 92%, respectively. We validate the performance of the two models on both balanced and imbalanced data. We further solidify the results by picking the combined selected anomalies of the two solutions with an "AND" operator for more reliable predictions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Statistical and Neural Network for Real Sensor-Data-Driven Anomaly Detection in Nuclear Applications

Anomaly detection (AD) in sensor data is critical to ensure uninterrupted functionality of nuclear power plants (NPPs). Consequently, validation of AD models through real-world sensor data is important for their application in nuclear facilities. In this paper, we propose an Autoencoder (AE)— a multi-layered neural network, for AD in sensor data from an operational NPP testbed. Since the dataset lacks labels for irregularities, we introduce random noise and label them to effectively train our model. The proposed AE model assigns a higher reconstruction error to the abnormal samples that deviate from those encountered during the training phase and uses the reconstruction loss to detect anomalies in a representative imbalanced dataset. We also introduce an analytical solution—seasonal trend decomposition (STD) — as another AD scheme for identifying irregularities within the same time-series dataset. In contrast to the AE model which relies on reconstruction loss, the STD scheme decomposes the entire dataset into its trend, seasonality, and residual components to pinpoint irregularities. Our findings indicate that the proposed AE and STD models individually achieve recall scores of 97% and 92%, respectively. We also validate the performance of the two models on both balanced and imbalanced data. We further solidify the results by picking the combined selected anomalies of the two solutions with an "AND" operator for more reliable predictions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of Novel Amplitude/Phase Binning Algorithm on Commercial Four-Dimensional Computed Tomography Quality

Purpose: Respiratory motion is a significant source of anatomic uncertainty in radiotherapy planning and can result in errors of portal size and the subsequent radiation dose. Although four-dimensional computed tomography allows for more accurate analysis of the respiratory cycle, breathing irregularities during data acquisition can cause considerable image distortions. The aim of this study was to examine the effect of respiratory irregularities on four-dimensional computed tomography, and to evaluate a novel image reconstruction algorithm using percentile-based tagging of the respiratory cycle. Methods and Materials: Respiratory-correlated helical computed tomography scans were acquired for 11 consecutive patients. The inspiration and expiration data sets were reconstructed using the default phase-based method, as well as a novel respiration percentile-based method with patient-specific metrics to define the ranges of the reconstruction. The image output was analyzed in a blinded fashion for the phase- and percentile-based reconstructions to determine the prevalence and severity of the image artifacts. Results: The percentile-based algorithm resulted in a significant reduction in artifact severity compared with the phase-based algorithm, although the overall artifact prevalence did not differ between the two algorithms. The magnitude of differences in respiratory tag placement between the phase- and percentile-based algorithms correlated with the presence of image artifacts. Conclusion: The results of our study have indicated that our novel four-dimensional computed tomography reconstruction method could be useful in detecting clinically relevant image distortions that might otherwise go unnoticed and to reduce the image distortion associated with some respiratory irregularities. Additional work is necessary to assess the clinical impact on areas of possible irregular breathing.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Motion-map constrained image reconstruction (MCIR): Application to four-dimensional cone-beam computed tomography

Purpose: Utilization of respiratory correlated four-dimensional cone-beam computed tomography (4DCBCT) has enabled verification of internal target motion and volume immediately prior to treatment. However, with current standard CBCT scan, 4DCBCT poses challenge for reconstruction due to the fact that multiple phase binning leads to insufficient number of projection data to reconstruct and thus cause streaking artifacts. The purpose of this study is to develop a novel 4DCBCT reconstruction algorithm framework called motion-map constrained image reconstruction (MCIR), that allows reconstruction of high quality and high phase resolution 4DCBCT images with no more than the imaging dose as well as projections used in a standard free breathing 3DCBCT (FB-3DCBCT) scan.Methods: The unknown 4DCBCT volume at each phase was mathematically modeled as a combination of FB-3DCBCT and phase-specific update vector which has an associated motion-map matrix. The motion-map matrix, which is the key innovation of the MCIR algorithm, was defined as the matrix that distinguishes voxels that are moving from stationary ones. This 4DCBCT model was then reconstructed with compressed sensing (CS) reconstruction framework such that the voxels with high motion would be aggressively updated by the phase-wise sorted projections and the voxels with less motion would be minimally updated to preserve the FB-3DCBCT. To evaluate the performance of our proposed MCIR algorithm, we evaluated both numerical phantoms and a lung cancer patient. The results were then compared with the (1) clinical FB-3DCBCT reconstructed using the FDK, (2) 4DCBCT reconstructed using the FDK, and (3) 4DCBCT reconstructed using the well-known prior image constrained compressed sensing (PICCS).Results: Examination of the MCIR algorithm showed that high phase-resolved 4DCBCT with sets of up to 20 phases using a typical FB-3DCBCT scan could be reconstructed without compromising the image quality. Moreover, in comparison with other published algorithms, the image quality of the MCIR algorithm is shown to be excellent.Conclusions: This work demonstrates the potential for providing high-quality 4DCBCT during on-line image-guided radiation therapy (IGRT), without increasing the imaging dose. The results showed that (at least) 20 phase images could be reconstructed using the same projections data, used to reconstruct a single FB-3DCBCT, without streak artifacts that are caused by insufficient projections.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High-Speed X-ray Phase Imaging with Grating Interferometer and White Synchrotron Light

Taking advantage of the fact that an X-ray Talbot interferometer functions with X-rays of a broad energy band width, high-speed X-ray phase imaging and tomography have been achieved by using white synchrotron light. An X-ray phase tomogram could be measured with a 0.25 s exposure. Furthermore, a series of X-ray phase tomograms, in other words, a four-dimensional X-ray phase tomogram, could be reconstructed with a tomogram frame rate of 25.5 fps. This achievement advances X-ray phase imaging/tomography from a technique for static imaging to one for dynamic imaging of weakly absorbing objects.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Phase retrieval using radiation and matter-wave fields: Validity of Teague's method for solution of the transport-of-intensity equation

Although originally developed for coherent paraxial scalar electromagnetic radiation in the visible-light regime, phase retrieval using the transport-of-intensity equation has been successfully applied to a range of paraxial radiation and matter-wave fields. Such applications include using electron wave fields to quantitatively image magnetic skyrmions and spin ices, propagation-based phase-contrast imaging using cold neutrons and hard x-rays, and visible-light refractive imaging of the projected column density of cold-atom clouds. Teague's method for phase retrieval using the transport-of-intensity equation, which renders the phase of a paraxial complex wave indirectly measurable via the existence of a conserved current, has been applied to a broad variety of situations which include all of the experiments described above. However, these applications have been undertaken without a thorough analysis of the underlying validity of the method. Here we derive sufficient conditions for the phase-retrieval solution provided by Teague's method to coincide with the true phase of the paraxial radiation or matter-wave field. We also present a sufficient condition guaranteeing that the discrepancy between the true phase function and that reconstructed using Teague's solution is small. These conditions demonstrate that, in most practical cases, for phase-amplitude retrieval using the transport-of-intensity equation, the Teague solution is very close to the exact solution. However, we also describe a counter example in the context of phase-amplitude retrieval using hard x-rays, in which the relative root-mean-square difference between the exact solution and that obtained using Teague's method is 9%. These findings clarify the foundations of one of the most widely applied methods for propagation-based phase retrieval of both paraxial matter and radiation wave fields and define a region for its applicability.

74 ATOMIC AND MOLECULAR PHYSICS↗

CO-induced lifting of Au (001) surface reconstruction.

We report CO-induced lifting of the hexagonal surface reconstruction on Au(001). Using in situ surface X-ray scattering, we determined a pressure-temperature phase diagram for the reconstruction and measured the dynamical evolution of the surface structure in real time. Our observations provide evidence that, under certain conditions, even macroscopic Au surfaces, much larger than catalytic Au nanoparticles (Haruta, M. Catal. Today 1997, 36, 153), can exhibit some of the reactive properties and surface transitions observed in systems known to be catalytically active such as Pt(001).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A comparison between soft x-ray and magnetic phase data on the Madison symmetric torus

The Soft X-Ray (SXR) tomography system on the Madison Symmetric Torus uses four cameras to determine the emissivity structure of the plasma. This structure should directly correspond to the structure of the magnetic field; however, there is an apparent phase difference between the emissivity reconstructions and magnetic field reconstructions when using a cylindrical approximation. The difference between the phase of the dominant rotating helical mode of the magnetic field and the motion of the brightest line of sight for each SXR camera is dependent on both the camera viewing angle and the plasma conditions. Holding these parameters fixed, this phase difference is shown to be consistent over multiple measurements when only toroidal or poloidal magnetic field components are considered. These differences emerge from physical effects of the toroidal geometry which are not captured in the cylindrical approximation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improving Weak Lensing Mass Map Reconstructions using Gaussian and Sparsity Priors: Application to DES SV

Mapping the underlying density field, including non-visible dark matter, using weak gravitational lensing measurements is now a standard tool in cosmology. Due to its importance to the science results of current and upcoming surveys, the quality of the convergence reconstruction methods should be well understood. We compare three methods: Kaiser–Squires (KS), Wiener filter, and Glimpse. Kaiser–Squires is a direct inversion, not accounting for survey masks or noise. The Wiener filter is well-motivated for Gaussian density fields in a Bayesian framework. Glimpse uses sparsity, aiming to reconstruct non-linearities in the density field. We compare these methods with several tests using public Dark Energy Survey (DES) Science Verification (SV) data and realistic DES simulations. The Wiener filter and Glimpse offer substantial improvements over smoothed Kaiser–Squires with a range of metrics. Both the Wiener filter and Glimpse convergence reconstructions show a 12 per cent improvement in Pearson correlation with the underlying truth from simulations. To compare the mapping methods’ abilities to find mass peaks, we measure the difference between peak counts from simulated ΛCDM shear catalogues and catalogues with no mass fluctuations (a standard data vector when inferring cosmology from peak statistics); the maximum signal-to-noise of these peak statistics is increased by a factor of 3.5 for the Wiener filter and 9 for Glimpse. With simulations, we measure the reconstruction of the harmonic phases; the phase residuals’ concentration is improved 17 per cent by Glimpse and 18 per cent by the Wiener filter. The correlationbetween reconstructions from data and foreground redMaPPer clusters is increased 18 per cent by the Wiener filter and 32 per cent by Glimpse.

79 ASTRONOMY AND ASTROPHYSICS↗

Concurrent determination of nanocrystal shape and amorphous phases in complex materials by diffraction scattering computed tomography

Advanced functional materials often contain multiple phases which are (nano)crystalline and/or amorphous. The spatial distribution of these phases and their properties, including nanocrystallite size and shape, often drives material function yet is difficult to obtain with current experimental techniques. This article describes the use of diffraction scattering computed tomography, which maps wide-angle scattering information onto sample space, to address this challenge. The wide-angle scattering signal contains information on both (nano)crystalline and amorphous phases. Rietveld refinement of reconstructed diffraction patterns is employed to determine anisotropic nanocrystal shapes. The background signal from refinements is used to identify contributing amorphous phases through multivariate curve resolution. Thus it is demonstrated that reciprocal space analysis in combination with diffraction scattering computed tomography is a very powerful tool for the complete analysis of complex multiphase materials such as energy devices.

Birkbak, Mie Elholm↗