Search NASA⌕ Search

SEARCH · Search NASA

Results for “Plasma measurements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Nonlinear interactions of electromagnetic waves with a thermally generated cesium plasma.

The interaction of a large‐amplitude disturbing wave with a thermally generated, highly ionized cesium plasma has been investigated using a small‐amplitude sensing wave as a probe. The subsequent interaction between the disturbing and sensing waves is related to the plasma electron temperature. The plasma was contained in a magnetic field of 500–1000 G and had an electron plasma frequency near 10 GHz and an electron gyromagnetic frequency around 2 GHz. The sensing wave was a 10 GHz plane wave of approximately 1.5 mW input power and the disturbing wave was 7.5 GHz plane wave of about 1.2 W peak power. Measurements of the sensing‐wave transmitted power were made using standard microwave techniques. A notch filter in the sensing‐wave receiving circuit reduced the scattered disturbing‐wave interference to an immeasurably low level. Langmuir probes were used to detect disturbing‐wave modulation and to measure plasma temperatures and densities. Measurements of the interaction were correlated with a solution of the Boltzmann transport equation for a perturbed Maxwellian distribution function with binary Coulomb collisions.

Jack G Hewitt, Jr↗

Cassini Observations of Saturn's Dawn-Magnetotail Region and their Relation to Models of Saturn's Aurora: Preliminary Results

Using Cassini plasma and magnetic field observations from the dawn meridian of Saturn s outer magnetosphere to Saturn s magnetotail region, we investigate the applicability of the centrifugal instability model by Sittler et al. [2006] for Saturn s auroral response to the solar wind, versus the reconnection model of Saturn s aurora by Cowley et al. [2005]. We use Cassini Plasma Spectrometer (CAPS) Ion Mass Spectrometer (IMS) and Electron Plasma Spectrometer (ELS) observations to characterize the plasma environment. ELS and magnetometer observations are used to map out the morphology of the outer magnetosphere from dawn to midnight local time. IMS observations are used to measure plasma flow velocities from which one can infer rotation versus convective flows. IMS composition measurements are used to trace the source of plasma from the inner magnetosphere (protons, H2 and water group ions) versus an external solar wind source (protons and Heff ions). A critical parameter for both models is the strength of the convection electric field with respect to the rotational electric field for the large scale magnetosphere. Is there a significant return flow from the magnetotail? Pitch angle distributions also play an important role as a discriminator. If the magnetosphere tends to conserve angular momentum as suggested by Sittler et al. [2006], then we expect to see an anti-correlation between rotational flow component and radial flow velocities. All will be investigated.

Sittler, E. C.↗

Plasma Perturbations in High-Speed Probing of Hall Thruster Discharge Chambers: Quantification and Mitigation

An experimental investigation is presented to quantify the effect of high-speed probing on the plasma parameters inside the discharge chamber of a 6-kW Hall thruster. Understanding the nature of these perturbations is of significant interest given the importance of accurate plasma measurements for characterizing thruster operation. An array of diagnostics including a high-speed camera and embedded wall probes is employed to examine in real time the changes in electron temperature and plasma potential induced by inserting a high-speed reciprocating Langmuir probe into the discharge chamber. It is found that the perturbations onset when the scanning probe is downstream of the electron temperature peak, and that along channel centerline, the perturbations are best characterized as a downstream shift of plasma parameters by 15-20% the length of the discharge chamber. A parametric study is performed to investigate techniques to mitigate the observed probe perturbations including varying probe speed, probe location, and operating conditions. It is found that the perturbations largely disappear when the thruster is operated at low power and low discharge voltage. The results of this mitigation study are discussed in the context of recommended methods for generating unperturbed measurements of the discharge chamber plasma.

Jorns, Benjamin A.↗

Phase Contrast Imaging Diagnostic on DIII-D (1994-2007); Phase Contrast Imaging Diagnostic on DIII-D and Alcator C-Mod (2007-2010); Experimental Study of Waves, Turbulence and Transport, and Model Validation with Phase Contrast Imaging on DIII-D and Alcator C-Mod (2010-2012); Phase Contrast Imaging Diagnostic Upgrade on DIII-D for Measuring High-k Turbulence and Alfven modes (2021-2016); Phase Contrast Imaging Diagnostic Upgrade on DIII-D for Full Multi-Scale Measurements (2016-2020) (Final Report)

This report describes the first twenty-five years of development and use of the Phase Contrast Imaging (PCI) diagnostic for measuring plasma fluctuations on the DIII–D tokamak. One of the key challenges in moving tokamak technology forward to the stage of a nuclear reactor remains understanding how energy and particles are transported across the magnetic field by the action of turbulence and waves, and PCI provides a highly flexible and capable measurement of these fluctuations. The PCI diagnostic uses a laser beam to probe the plasma and optical filtering to produce an amplitude variation on a linear detector array which provides an image of the density waves in the plasma. The PCI covers an exceptional range in frequency and wavelength of the measured fluctuations, allowing observation of plasma-sized magnetohydrodynamic (MHD) modes and ion- and electron-scale turbulence. Modulation of the beam amplitude allows measurement of radio frequency (RF) waves.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ion populations in the tail of Venus

Plasma measurements in the tails of Venus showed the existence of several ion populations. Measurements performed on Venera and Pioneer Venus spacecraft at different planetocentric distances showed the evolution of the plasma parameters along the tail. Low-energy ion fluxes measured in the tail at close downstream distances, are also observed farther downstream, and show low acceleration from 0.5 R(sub V) to 12 R(sub V). High energy ions (energetic O(+) ions) reported from Pioneer Venus Orbiter (PVO) observations in the tail at 10-12 R(sub V) seem to be the same ion component that was observed as energetic ions at the tail boundary close to the planet on Venera spacecraft. We give evidence that these ions are accelerated in the narrow shear layer near the tail boundary.

Vaisberg, O.↗

Biofluid-based staging of Alzheimer’s disease

Recently, conceptual systems for the in vivo staging of Alzheimer’s disease (AD) using fluid biomarkers have been suggested. Thus, it is important to assess whether available fluid biomarkers can successfully stage AD into clinically and biologically relevant categories. In the TRIAD cohort, we explored whether p-tau217, p-tau205 and NTA-tau (biomarkers of early, intermediate and late AD pathology, respectively) have potential for biofluid-based staging in cerebrospinal fluid (CSF; n = 219) and plasma (n = 150), and compared them in a paired CSF and plasma subset (n = 76). Our findings suggest a good concordance between biofluid staging and underlying pathology when classifying amyloid-positivity into three categories based on neurofibrillary pathology: minimal/non-existent (p-tau217 positive), early-to-intermediate (p-tau217 and p-tau205 positivity), and advanced tau tangle deposition (p-tau217, p-tau205 and NTA-tau positive), as indexed by tau-PET. Discordant cases accounted for 4.6% and 13.3% of all CSF and plasma measurements respectively (9.2% and 11.8% in paired samples). Notably, CSF- and plasma-based staging matched one another in 61.7% of the cases, while approximately 32% of the remaining participants were one to three biofluid stages higher in CSF as compared to plasma. Overall, these exploratory results suggest that biofluid staging of AD holds potential for offering valuable insights into underlying AD hallmarks and disease severity. However, its applicability beyond molecular characterization at research settings has yet to be demonstrated.

60 APPLIED LIFE SCIENCES↗

Examining Periodic Solar-Wind Density Structures Observed in the SECCHI Heliospheric Imagers

We present an analysis of small-scale, periodic, solar-wind density enhancements (length scales as small as approximately equals 1000 Mm) observed in images from the Heliospheric Imager (HI) aboard STEREO-A. We discuss their possible relationship to periodic fluctuations of the proton density that have been identified at 1 AU using in-situ plasma measurements. Specifically, Viall, Kepko, and Spence examined 11 years of in-situ solar-wind density measurements at 1 AU and demonstrated that not only turbulent structures, but also nonturbulent, periodic density structures exist in the solar wind with scale sizes of hundreds to one thousand Mm. In a subsequent paper, Viall, Spence, and Kasper analyzed the alpha-to-proton solar-wind abundance ratio measured during one such event of periodic density structures, demonstrating that the plasma behavior was highly suggestive that either temporally or spatially varying coronal source plasma created those density structures. Large periodic density structures observed at 1 AU, which were generated in the corona, can be observable in coronal and heliospheric white-light images if they possess sufficiently high density contrast. Indeed, we identify such periodic density structures as they enter the HI field of view and follow them as they advect with the solar wind through the images. The smaller, periodic density structures that we identify in the images are comparable in size to the larger structures analyzed in-situ at 1 AU, yielding further evidence that periodic density enhancements are a consequence of coronal activity as the solar wind is formed.

Viall, Nicholeen M.↗

MESSENGER Orbital Observations of Large-Amplitude Kelvin-Helmholtz Waves at Mercury's Magnetopause

We present a survey of Kelvi\ n-Helmholtz (KH) waves at Mercury's magnetopause during MESSENGER's first Mercury year in orb it. The waves were identified on the basis of the well-established sawtooth wave signatures that are associated with non-linear KH vortices at the magnetopause. MESSENGER frequently observed such KH waves in the dayside region of the magnetosphere where the magnetosheath flow velocity is still sub -sonic, which implies that instability growth rates at Mercury's magnetopau~ are much larger than at Earth. We attribute these greater rates to the limited wave energy dissipation in Mercury's highly resistive regolith. The wave amplitude was often on the order of ' 00 nT or more, and the wave periods were - 10- 20 s. A clear dawn-dusk asymmetry is present in the data, in that all of the observed wave events occurred in the post-noon and dusk-side sectors of the magnetopause. This asymmetry is like ly related to finite Larmor-radius effects and is in agreement with results from particle-in-cell simulations of the instability. The waves were observed almost exclusively during periods when the north-south component of the magnetosheath magnetic field was northward, a pattern similar to that for most terrestrial KH wave events. Accompanying plasma measurements show that the waves were associated with the transport of magnetosheath plasma into the magnetosphere.

Sundberg, Torbjorn↗

Observational Consequences of Coronal Heating Mechanisms

The coronal heating problem remains unsolved today, 80 years after its discovery, despite 50 years of suborbital and orbital coronal observatories. Tens of theoretical coronal heating mechanisms have been suggested, but only a few have been able to be ruled out. In this talk, we will explore the reasons for the slow progress and discuss the measurements that will be needed for potential breakthrough, including imaging the solar corona at small spatial scales, measuring the chromospheric magnetic fields, and detecting the presence of high temperature, low emission measure plasma. We will discuss three sounding rocket instruments developed to make these measurements: the High resolution Resolution Coronal Imager (Hi-C), the Chromospheric Lyman-Alpha Spectropolarimeter (CLASP), and the Marshall Grazing Incidence X-ray Spectrometer (MaGIXS).

Winebarger, Amy R.↗

New Instruments to Isolate the Coronal Heating Mechanism

The coronal heating problem remains unsolved today, 80 years after its discovery, despite 50 years of suborbital and orbital coronal observatories. Tens of theoretical coronal heating mechanisms have been suggested, but only a few have been able to be ruled out. In this talk, we will explore the reasons for the slow progress and discuss the measurements that will be needed for potential breakthrough, including imaging the solar corona at small spatial scales, measuring the chromospheric magnetic fields, and detecting the presence of high temperature, low‐emission measure plasma. We will discuss three sounding rocket instruments developed to make these measurements: the High‐resolution Resolution Coronal Imager (Hi‐C), the Chromospheric Lyman‐Alpha Spectropolarimeter (CLASP), and the Marshall Grazing Incidence X‐ray Spectrometer (MaGIXS).

Winebarger, Amy↗

The 2 Pi Charged Particles Analyzer: All-Sky Camera Concept and Development for Space Missions

Increasing the temporal resolution and instant coverage of velocity space of space plasma measurements is one of the key issues for experimentalists. Today, the top-hat plasma analyzer appears to be the favorite solution due to its relative simplicity and the possibility to extend its application by adding a mass-analysis section and an electrostatic angular scanner. Similarly, great success has been achieved in MMS mission using such multiple top-hat analyzers to achieve unprecedented temporal resolution. An instantaneous angular coverage of charged particles measurements is an alternative approach to pursuing the goal of high time resolution. This was done with 4-D Fast Omnidirectional Nonscanning Energy Mass Analyzer and, to a lesser extent, by DYMIO instruments for Mars-96 and with the Fast Imaging Plasma Spectrometer instrument for MErcury Surface, Space ENvironment, GEochemistry, and Ranging mission. In this paper we describe, along with precursors, a plasma analyzer with a 2 electrostatic mirror that was developed originally for the Phobos-Soil mission with a follow-up in the frame of the BepiColombo mission and is under development for future Russian missions. Different versions of instrument are discussed along with their advantages and drawbacks.

Vaisberg, O.↗

Wave properties near the subsolar magnetopause - Pc 3-4 energy coupling for northward interplanetary magnetic field

Strong slow mode waves in the Pc 3-4 frequency range are found in the magnetosheath close to the magnetopause. We have studied these waves at one of the ISEE subsolar magnetopause crossings using the magnetic field, electric field, and plasma measurements. We use the pressure balance at the magnetopause to calibrate the Fast Plasma Experiment data versus the magnetometer data. When we perform such a calibration and renormalization, we find that the slow mode structures are not in pressure balance and small scale fluctuations in the total pressure still remain in the Pc 3-4 range. Energy in the total pressure fluctuations can be transmitted through the magnetopause by boundary motions. The Poynting flux calculated from the electric and magnetic field measurements suggests that a net Poynting flux is transmitted into the magnetopause. The two independent measurements show a similar energy transmission coefficient. The transmitted energy flux is about 18 percent of the magnetic energy flux of the waves in the magnetosheath. Part of this transmitted energy is lost in the sheath transition layer before it enters the closed field line region. The waves reaching the boundary layer decay rapidly. Little wave power is transmitted into the magnetosphere.

Song, P.↗

LC/MS Method for the Determination of Stable Isotope Labeled Promethazine in Human Plasma

Promethazine (PMZ) is taken by astronauts orally (PO), intramuscularly (IM) or rectally (PR) for space motion sickness. LC/MS method was developed with off-line solid phase extraction to measure plasma concentrations of PMZ given as stable isotope-labeled (SIL) formulations by the three different routes of administration simultaneously. Samples (0.5ml) were loaded on to Waters Oasis HLB co-polymer cartridges and eluted with 1.0 mL methanol. HPLC separation of the eluted sample was performed using an Agilent Zorbax SB-CN column (50 x 2.1 mm) at a flow rate of 0.2 mL/min for 6 min. Acetonitrile/ ammonium acetate (30 mM) in water (3:2, v/v), pH 5.6 plus or minus 0.1, was used as the mobile phase for separation. Concentrations of PMZ, PMZ-d4 and PMZ-d7 and chlorpromazine (internal standard) were determined using a Micromass ZMD single quadrupole mass spectrometer with Electrospray Ionization (ESI). ESI mass spectra were acquired in positive ion mode with selected ion monitoring of [M+ H]dot plus. The method is rapid, reproducible and the assay specific parameters are listed in a table. A novel, sensitive and specific method for the measurement of PMZ and SIL PMZ in human plasma is reported.

Zuwei, Wang↗

Surface conversion techniques for low energy neutral atom imagers

This investigation has focused on development of key technology elements for low energy neutral atom imaging. More specifically, we have investigated the conversion of low energy neutral atoms to negatively charged ions upon reflection from specially prepared surfaces. This 'surface conversion' technique appears to offer a unique capability of detecting, and thus imaging, neutral atoms at energies of 0.01 - 1 keV with high enough efficiencies to make practical its application to low energy neutral atom imaging in space. Such imaging offers the opportunity to obtain the first instantaneous global maps of macroscopic plasma features and their temporal variation. Through previous in situ plasma measurements, we have a statistical picture of large scale morphology and local measurements of dynamic processes. However, with in situ techniques it is impossible to characterize or understand many of the global plasma transport and energization processes. A series of global plasma images would greatly advance our understanding of these processes and would provide the context for interpreting previous and future in situ measurements. Fast neutral atoms, created from ions that are neutralized in collisions with exospheric neutrals, offer the means for remotely imaging plasma populations. Energy and mass analysis of these neutrals provides critical information about the source plasma distribution. The flux of neutral atoms available for imaging depends upon a convolution of the ambient plasma distribution with the charge exchange cross section for the background neutral population. Some of the highest signals are at relatively low energies (well below 1 keV). This energy range also includes some of the most important plasma populations to be imaged, for example the base of the cleft ion fountain.

Quinn, J. M.↗

SUMMA hot-ion plasma heating research at NASA Lewis Research Center

The SUMMA superconducting magnetic mirror facility and the associated hot-ion plasma research were described. SUMMA is characterized by intense magnetic fields and a large-diameter working bore (41 cm diameter) with room-temperature access. The goal of the plasma research program is to produce steady-state plasmas of fusion reactor densities and temperatures (but not confinement times). The program includes electrode development to produce a hot, dense, large-volume, steady-state plasma and diagnostics development to document the plasma properties. SUMMA and its hot-ion plasma are ideally suited to develop advanced plasma diagnostics methods. Two such methods whose requirements are well matched to SUMMA are: (1) heavy ion beam probing to measure plasma space potential; and (2) submillimeter wavelength laser Thomson scattering to measure local ion temperature.

Reinmann, J. J.↗

SUMMA hot-ion plasma heating research at NASA Lewis Research Center

This report describes the SUMMA superconducting magnetic mirror facility at the NASA Lewis Research Center and the hot-ion plasma research conducted therein. SUMMA is characterized by intense magnetic fields (designed for 8.6 T at the mirrors) and a large-diameter working bore (41 cm diameter) with room-temperature access. The goal of the plasma research program is to produce steady-state plasmas of fusion reactor densities and temperatures (but not confinement times). The program includes electrode development to produce a hot, dense, large-volume, steady-state plasma and diagnostics development to document the plasma properties. SUMMA and its hot-ion plasma are ideally suited to develop advanced plasma diagnostics methods. Two such methods whose requirements are well matched to SUMMA are: (1) heavy ion beam probing to measure plasma space potential, and (2) submillimeter wavelength laser Thomson scattering to measure local ion temperature. Two NASA University Grants were established to identify major requirements for developing these two diagnostic techniques in SUMMA.

Reinmann, J. J.↗

Cosmological constraints on hot plasma in a closed universe

A hot uniform collisionally heated intergalactic medium (IGM) at closure density is reconsidered. Optical depth measurements, plasma cooling and ionic abundances during the recombination epoch are discussed. The data are used to calculate X-radiation at critical energies. The results indicate a present temperature from 160,000 to 4,200,000 K if the reheating of the IGM ceased at the latest possible time. As cessation of heating moves to earlier times, the range of present plasma temperature narrows until at the earliest possible cessation time only about 160,000 K is acceptable. Relevant formulae are provided to modify these numbers as new data become available. This IGM avoids any hard X-ray production and thus assumes that discrete sources alone constitute the entire cosmic X-ray background.

Sherman, R. D.↗