Search NASA⌕ Search

SEARCH · Search NASA

Results for “Position Sensitive Detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Parallel-plate avalanche counters for heavy-ion beam tracking: History and mysteries

Despite being an old detector concept, position-sensitive parallel-plate avalanche counters (PPACs) remain widely used today for heavy-ion position and timing measurements. In modern rare isotope beam facilities and large-acceptance fragment separators, PPACs are used to characterize beam properties (diagnostics), facilitate beam delivery (tuning), and provide event-by-event beam tracking for particle identification (PID). Most popular particle localization methods in PPAC detectors are based on strip electrodes electrically connected to resistive-chain circuits or delay lines. More exotic systems include optical readouts based on recording electroluminescence light with high-granularity photodetector arrays or high-resolution resistive anode electrodes. PPACs with conventional resistive-chain or delay-line readouts achieve typical position and time resolutions of below 1 mm ( σ ) and around 150 ps ( σ ), respectively. In addition, delay-line systems are capable of counting rates above several hundred kHz for beam areas of a few millimeters square, and around 1 MHz for larger beam sizes. Resistive-chain readouts have limited rates of a few tens of kHz. A review of the operation principles and performance of PPAC detectors is presented in this paper. We will discuss decades-long experience building and operating PPACs developed at the National Superconducting Cyclotron Laboratory, and then refined at the Facility for Rare Isotope Beams (FRIB), mostly focusing on the delay-line readout technique (DLPPAC). We will also discuss problems that arise due to electric discharges at high rates and briefly describe ongoing developments at FRIB. Published by the American Physical Society 2024

Physics↗

Gated truncated readout system

A gated truncated readout system for position sensitive or imaging detectors that improves resolution over traditional readout systems. The readout system includes two or more amplifiers that receive a multichannel output analog data from the detector. Analog gates control circuitry, included in the readout circuit, receives the signals from the amplifiers, determines a fractional value of the sum-integral of the signals, and enables analog gates operation around an area of interest, disabling all other channels where noise dominates the signal value and thereby improving interpolation accuracy of the signals centroid position and the detector resolution. Filtered signals are transmitted to a centroid interpolation signal processing device for computation of the centroid position. As a result disabling all channels where noise dominates the signal value, the gated truncated readout system provides better accuracy improved detector resolution.

Popov, Vladimir↗

Technical aspects of real time positron emission tracking for gated radiotherapy

Purpose: Respiratory motion can lead to treatment errors in the delivery of radiotherapy treatments. Respiratory gating can assist in better conforming the beam delivery to the target volume. We present a study of the technical aspects of a real time positron emission tracking system for potential use in gated radiotherapy. Methods: The tracking system, called PeTrack, uses implanted positron emission markers and position sensitive gamma ray detectors to track breathing motion in real time. PeTrack uses an expectation–maximization algorithm to track the motion of fiducial markers. A normalized least mean squares adaptive filter predicts the location of the markers a short time ahead to account for system response latency. The precision and data collection efficiency of a prototype PeTrack system were measured under conditions simulating gated radiotherapy. The lung insert of a thorax phantom was translated in the inferior–superior direction with regular sinusoidal motion and simulated patient breathing motion (maximum amplitude of motion ±10 mm, period 4 s). The system tracked the motion of a {sup 22}Na fiducial marker (0.34 MBq) embedded in the lung insert every 0.2 s. The position of the was marker was predicted 0.2 s ahead. For sinusoidal motion, the equation used to model the motion was fitted to the data. The precision of the tracking was estimated as the standard deviation of the residuals. Software was also developed to communicate with a Linac and toggle beam delivery. In a separate experiment involving a Linac, 500 monitor units of radiation were delivered to the phantom with a 3 × 3 cm photon beam and with 6 and 10 MV accelerating potential. Radiochromic films were inserted in the phantom to measure spatial dose distribution. In this experiment, the period of motion was set to 60 s to account for beam turn-on latency. The beam was turned off when the marker moved outside of a 5-mm gating window. Results: The precision of the tracking in the IS direction was 0.53 mm for a sinusoidally moving target, with an average count rate ∼250 cps. The average prediction error was 1.1 ± 0.6 mm when the marker moved according to irregular patient breathing motion. Across all beam deliveries during the radiochromic film measurements, the average prediction error was 0.8 ± 0.5 mm. The maximum error was 2.5 mm and the 95th percentile error was 1.5 mm. Clear improvement of the dose distribution was observed between gated and nongated deliveries. The full-width at halfmaximum of the dose profiles of gated deliveries differed by 3 mm or less than the static reference dose distribution. Monitoring of the beam on/off times showed synchronization with the location of the marker within the latency of the system. Conclusions: PeTrack can track the motion of internal fiducial positron emission markers with submillimeter precision. The system can be used to gate the delivery of a Linac beam based on the position of a moving fiducial marker. This highlights the potential of the system for use in respiratory-gated radiotherapy.

61 RADIATION PROTECTION AND DOSIMETRY↗

WE-EF-303-03: A New Aperture-Based Imaging System for Prompt-Gamma Range Verification of Proton Beam Therapy

Purpose: To develop and characterize a novel aperture-based imaging system for high-energy gamma-rays. This collimated system will provide 2-dimensional imaging capability for verification of proton beam range and Bragg peak dose via prompt-gamma detection. Methods: A multi-knife-edge slit collimator has been designed, constructed, and characterized via simulations and experimental measurements. The 20×20×7.5 cm{sup 3} tungsten collimator and accompanying LSO scintillation detector were simulated using the TOPAS Geant4 -based Monte Carlo package. Iterative reconstruction methods were combined with point response functions to characterize the imaging performance of the system. The response of the system has begun to be characterized experimentally as well, using 2.6 MeV gamma-rays from Th-228. Results: Both simulation and experimental results indicate that this collimated system provides 2-D imaging capability in the energy range of interest for prompt-gamma dose verification. In the current configuration, with collimator to source distance of 13 cm, image reconstruction of point sources resulted in spatial resolution (FWHM) of approximately 4 mm in both x-and y-directions in the imaging plane. The accuracy of positioning the point sources is less than 1 mm. Conclusion: This work has characterized, via simulation and measurements, a novel multi-knife-edge slit collimator in front of a more conventional position-sensitive LSO scintillator detector. The multi-slit pattern is designed to increase detection efficiency and provide spatial information in 2-dimensions -- an improvement over a single-slit collimator design. The thickness and density of the collimator will allow this detection system to perform well in an environment with high gamma flux, while ultimately providing peak determination accuracy on the order of 1 mm. This material is based upon work supported by the Department of Energy National Nuclear Security Administration under Award Number: DE-NA0000979 through the Nuclear Science and Security Consortium.

60 APPLIED LIFE SCIENCES↗

Remediating neutron damage in large area planar Ge-DSSD with amorphous germanium contacts through annealing and pulse-height correction

Large area, position sensitive planar germanium detectors offer new opportunities in -ray spectroscopy. For in-beam studies remediating neutron damage is important. This work studied a mechanically cooled circular planar 9 × 1 cm wafer with orthogonal 16 × 16 amorphous germanium strip electrodes. Before neutron irradiation the wafer was heated in-cryostat to above 373 K for more than 24 h in order to test the robustness of the contacts and the mechanical cooler. No deterioration in performance was observed. The detector was then exposed to controlled doses of 2.2 MeV neutrons, produced from the 7 Li(p,n) 7 Be reaction until substantial damage was observed. Averaged over the surface of the wafer, a flux of 1.9(1) x 10 9 n/cm 2 was delivered. The detector then survived thermal cycling and 350 K (~77°C) annealing for 70 h which substantially reduced hole trapping. pulse-height correction is investigated to further mitigate the neutron damage. Higher temperature annealing at 365 K was not successful.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Single-particle structure of neutron-rich nuclei

Neutron transfer (d,p) reactions have been measured with rare isotope beams of {sup 132}Sn, {sup 130}Sn and {sup 134}Te accelerated to {approx}4.5 MeV/u interacting with CD{sub 2} targets. Reaction protons were detected in an early implementation of the ORRUBA array of position-sensitive silicon strip detectors. Neutron excitations in the 2f{sub 7/2}, 3p{sub 3/2}, 3p{sub 1/2} and 2f{sub 5/2} orbitals were populated.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Absence of a guiding effect and charge transfer in the interaction of keV-energy negative ions with Al{sub 2}O{sub 3} nanocapillaries

In this work, the efficient electron loss process was observed for the transmission of 10- to 18-keV Cu{sup -} and Cl{sup -} ions through Al{sub 2}O{sub 3} nanocapillaries. The fractions of the scattered particles were simultaneously measured using a position-sensitive microchannel plate detector. The neutrals were guided through the capillary via multiple grazing scattering. In particular, the scattered Cl{sup -} ions were observed in the transmission, whereas no Cu{sup -} ion was formed. In contrast to highly charged ions, these results support strongly the fact that the scattering events dominate the transport of negative ions through the nanocapillaries and that there is no direct evidence for the formation of negative charge patches inside the capillaries which are able to repulse and guide negative ions efficiently.

74 ATOMIC AND MOLECULAR PHYSICS↗

In-beam conversion-electron spectroscopy of {sup 180}Hg

Excited states in {sup 180}Hg were populated using the {sup 147}Sm({sup 36}Ar,3n){sup 180}Hg reaction and studied by in-beam conversion-electron spectroscopy. Conversion electrons emitted at the target position were measured using the Silicon Array for Conversion Electron Detection (SACRED) spectrometer and tagged through the characteristic {alpha} decays of {sup 180}Hg detected in a position-sensitive silicon strip detector located at the focal plane of the gas-filled recoil separator Recoil Ion Transport Unit (RITU). Electron conversion of transitions previously assigned to {sup 180}Hg through in-beam {gamma}-ray spectroscopy studies was identified up to the 10{sup +}{yields}8{sup +} transition and the intensities of the conversion-electron transitions were found to be consistent with the previous multipolarity assignments. Evidence was also found for two highly converted transitions in {sup 180}Hg: a 167 keV transition is interpreted as the transition from the newly identified 2{sub 2}{sup +} state at 601 keV to the 2{sub 1}{sup +} state at 434 keV, while a 420 keV transition is assigned as the E0 decay from the 0{sup +} bandhead of the prolate-deformed configuration to the weakly deformed ground state.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Informing direct neutron capture on tin isotopes near the N = 82 shell closure

Half of the elements heavier than iron are believed to be produced through the rapid neutron-capture process ($r$-process). The astrophysical environment(s) where the $r$-process occurs remains an open question, even after recent observations of neutron-star mergers and the associated kilonova. Features in the abundance pattern of $r$-process ashes may provide critical insight for distinguishing contributions from different possible sites, including neutron-star mergers and core-collapse supernovae. In particular, the largely unknown neutron-capture reaction rates on neutron-rich unstable nuclei near 132 Sn could have a significant impact on the final $r$-process abundances. To better determine these neutron-capture rates, the ($d,p$) reaction has been measured in inverse kinematics using radioactive ion beams of 126 Sn and 128 Sn and a stable beam of 124 Sn interacting with a (CD 2 )$_n$ target. An array of position-sensitive silicon strip detectors, including the Super Oak Ridge Rutgers University Barrel Array, was used to detect light reaction products. In addition to the present measurements, previous measurements of 130,132 Sn($d,p$) were reanalyzed using state-of-the-art reaction theory to extract a consistent set of spectroscopic factors for ($d,p$) reactions on even tin nuclei between the heaviest stable isotope 124 Sn and doubly magic 132 Sn. The spectroscopic information was used to calculate direct-semidirect ($n,γ$) cross sections, which will serve as important input for r-process abundance calculations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Constraining spectroscopic factors near the r -process path using combined measurements: Kr 86 ( d , p ) 87 Kr

Background: Current nuclear structure models indicate that the shell structure near the valley of stability, with well-established shell closures at N=50, for example, changes in very neutron-rich nuclei far from stability. Single-particle properties of nuclei away from stability can be probed in single-neutron (d,p) transfer reactions with beams of rare isotopes. The interpretation of these data requires reaction theories with various effective interactions. Often, approximations made to the final bound-state potential introduce a large uncertainty in the extracted single-particle properties, in particular the spectroscopic factor. Purpose: Mitigate this uncertainty using a combined measurement method to constrain the shape of the bound-state potential and to reliably extract the spectroscopic factor. Methods: The 2 H( 86 Kr,p) 87 Kr reaction was measured at 33 MeV/u at the National Superconducting Cyclotron Laboratory (NSCL) as a test of the combined method. The reaction protons were detected with the Oak Ridge Rutgers University Barrel Array (ORRUBA) of position sensitive silicon strip detectors, the first implementation of ORRUBA coupled to the S800 spectrograph with fast beams at NSCL. Results: These measurements at 33 MeV/u are combined with previous studies of the 86 Kr(d,p) reaction at 5.5 MeV/u to demonstrate a successful case of the combined method to constrain the shape of the single-particle potential and deduce asymptotic normalization coefficients and spectroscopic factors. In particular, the single-particle asymptotic normalization coefficient for the ground state of 87 Kr was constrained to b d5/2 =6.46$^{+1.12}_{–0.57}$ fm –1/2 , and therefore the deduced spectroscopic factor is S=0.44$^{+0.09}_{–0.13}$ with uncertainties dominated by experimental statistics. Conclusions: By combining measurements at two very different beam energies, single-particle asymptotic normalization coefficients, at least for low angular momentum transfers, can be constrained. Thus, spectroscopic factors can be deduced with uncertainties dominated by experimental uncertainties, rather than limited knowledge of bound-state potential parameters.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Track and vertex reconstruction: From classical to adaptive methods

This paper reviews classical and adaptive methods of track and vertex reconstruction in particle physics experiments. Adaptive methods have been developed to meet the experimental challenges at high-energy colliders, in particular, the CERN Large Hadron Collider. They can be characterized by the obliteration of the traditional boundaries between pattern recognition and statistical estimation, by the competition between different hypotheses about what constitutes a track or a vertex, and by a high level of flexibility and robustness achieved with a minimum of assumptions about the data. The theoretical background of some of the adaptive methods is described, and it is shown that there is a close connection between the two main branches of adaptive methods: neural networks and deformable templates, on the one hand, and robust stochastic filters with annealing, on the other hand. As both classical and adaptive methods of track and vertex reconstruction presuppose precise knowledge of the positions of the sensitive detector elements, the paper includes an overview of detector alignment methods and a survey of the alignment strategies employed by past and current experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Inferring small-sample-reactivity worth from oscillation experiment with auto-corrected local flux

To estimate reactivity changes as a function of time from the signal of detectors count rates, one usually uses point kinetic equations. However, when detectors are located inside the core, it is often necessary to compute a correction factor to account for the flux-shape deformation (i.e. the change of detector efficiency that may have been induced by neutron absorbers movements). Various simulation methods have been developed depending on transients observed. They range from the resolution of static equations up to full-time-dependent neutron transport in 3D. However, those methods require high computational-cost calculations of local reaction rates that rely on nuclear data evaluations. Therefore, a 'measured' reactivity is never determined through pure measurements. Taking advantage of the known oscillation movement of a small sample at the center of the MINERVE reactor, the innovative algorithm presented in this paper derives the correction factor needed to get no time drift on reactivity steps. Derived correction factors are in good agreement with those obtained independently with TRIPOLI-4 through sensitivity analysis. Low sensitivity to the sample composition and moderate sensitivity to the detectors position reinforce the reliability of those results. This application paves the way to almost pure nuclear data reactivity measurements. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

AXEAP (ARGONNE X-RAY EMISSION PACKAGE)

Argonne X-ray Emission Package (AXEAP), a singular purpose software package for processing X-ray emission (XES) images collected with a 2-dimensional position sensitive pixel array detector, has been developed. AXEAP can rapidly convert XES image files into a spectral form by applying parallel computation and unsupervised machine learning to compute vast amount of image data. Special focus has been placed on designing user-friendly-interface for processing multiple edges, non-resonant and resonant x-ray emission image analysis, in order to make data processing quick and easy. AXEAP is free software and is written in MATLAB, armed with powerful libraries and toolboxes. The software runs on all common operating systems such as Linux, Window, and Mac.

SUN, CHENGJUN↗

Numerical studies of the flux-to-current ratio method in the KIPT neutron source facility

The reactivity of a subcritical assembly has to be monitored continuously in order to assure its safe operation. In this paper, the flux-to-current ratio method has been studied as an approach to provide the on-line reactivity measurement of the subcritical system. Monte Carlo numerical simulations have been performed using the KIPT neutron source facility model. It is found that the reactivity obtained from the flux-to-current ratio method is sensitive to the detector position in the subcritical assembly. However, if multiple detectors are located about 12 cm above the graphite reflector and 54 cm radially, the technique is shown to be very accurate in determining the k{sub eff} this facility in the range of 0.75 to 0.975. (authors)

97 MATHEMATICS AND COMPUTING↗

Energy-sensitive imaging detector applied to the dissociative recombination of D{sub 2}H{sup +}

We report on an energy-sensitive imaging detector for studying the fragmentation of polyatomic molecules in the dissociative recombination of fast molecular ions with electrons. The system is based on a large area (10x10 cm{sup 2}) position-sensitive, double-sided Si-strip detector with 128 horizontal and 128 vertical strips, whose pulse height information is read out individually. The setup allows us to uniquely identify fragment masses and is thus capable of measuring branching ratios between different fragmentation channels, kinetic energy releases, and breakup geometries as a function of the relative ion-electron energy. The properties of the detection system, which has been installed at the Test Storage Ring (TSR) facility of the Max-Planck Institute for Nuclear Physics in Heidelberg, is illustrated by an investigation of the dissociative recombination of the deuterated triatomic hydrogen cation D{sub 2}H{sup +}. A huge isotope effect is observed when comparing the relative branching ratio between the D{sub 2} + H and the HD + D channel; the ratio 2B(D{sub 2} + H)/B(HD + D), which is measured to be 1.27{+-}0.05 at relative electron-ion energies around 0 eV, is found to increase to 3.7{+-}0.5 at {approx}5 eV.

74 ATOMIC AND MOLECULAR PHYSICS↗

Hammerhead, an ultrahigh resolution ePix camera for wavelength-dispersive spectrometers

Wavelength-dispersive spectrometers (WDS) are often used in synchrotron and FEL applications where high energy resolution (in the order of eV) is important. Increasing WDS energy resolution requires increasing spatial resolution of the detectors in the dispersion direction. The common approaches are not ideal: using strip detectors loses the 2D position sensitivity (important for, e.g., background estimation) and the high counting rate; using pixel detectors with a small pitch results in complex charge sharing behaviour and typically have a small size. Developing pixel detectors with high aspect ratio and a small pitch in the wavelength dispersive direction would be ideal, however, it would require a substantial ASIC development. We present a new approach, with a novel sensor design using rectangular pixels with a high aspect ratio (between strips and pixels, further called “strixels”), and strixel redistribution to match the square pixel arrays of typical ASICs. This results in a sensor area of 17.4 mm × 77 mm, with a fine pitch of 25 µm in the horizontal direction resulting in 3072 columns and 176 rows. The sensors use ePix100 readout ASICs, leveraging their low noise (43 e - , or 180 eV rms). We present results obtained with a Hammerhead ePix100 camera, showing that the small pitch (25 µm) in the dispersion direction maximizes performance for both high and low photon occupancies, resulting in optimal WDS energy resolution. The low noise level at high photon occupancy allows precise photon counting, while at low occupancy, both the energy and the subpixel position can be reconstructed for every photon, allowing an ultrahigh resolution (in the order of 1 µm) in the dispersion direction and rejection of scattered beam and harmonics. Using strixel sensors with redistribution and flip-chip bonding to standard ePix readout ASICs results in ultrahigh position resolution (~1 µm) and low noise in WDS applications, leveraging the advantages of hybrid pixel detectors (high production yield, good availability, relatively inexpensive) while minimizing development complexity through sharing the ASIC, hardware, software and DAQ development with other versions of ePix cameras.

47 OTHER INSTRUMENTATION↗

SU-E-T-377: Inaccurate Positioning Might Introduce Significant MapCheck Calibration Error in Flatten Filter Free Beams

Purpose: This study investigates the calibration error of detector sensitivity for MapCheck due to inaccurate positioning of the device, which is not taken into account by the current commercial iterative calibration algorithm. We hypothesize the calibration is more vulnerable to the positioning error for the flatten filter free (FFF) beams than the conventional flatten filter flattened beams. Methods: MapCheck2 was calibrated with 10MV conventional and FFF beams, with careful alignment and with 1cm positioning error during calibration, respectively. Open fields of 37cmx37cm were delivered to gauge the impact of resultant calibration errors. The local calibration error was modeled as a detector independent multiplication factor, with which propagation error was estimated with positioning error from 1mm to 1cm. The calibrated sensitivities, without positioning error, were compared between the conventional and FFF beams to evaluate the dependence on the beam type. Results: The 1cm positioning error leads to 0.39% and 5.24% local calibration error in the conventional and FFF beams respectively. After propagating to the edges of MapCheck, the calibration errors become 6.5% and 57.7%, respectively. The propagation error increases almost linearly with respect to the positioning error. The difference of sensitivities between the conventional and FFF beams was small (0.11 ± 0.49%). Conclusion: The results demonstrate that the positioning error is not handled by the current commercial calibration algorithm of MapCheck. Particularly, the calibration errors for the FFF beams are ~9 times greater than those for the conventional beams with identical positioning error, and a small 1mm positioning error might lead to up to 8% calibration error. Since the sensitivities are only slightly dependent of the beam type and the conventional beam is less affected by the positioning error, it is advisable to cross-check the sensitivities between the conventional and FFF beams to detect potential calibration errors due to inaccurate positioning. This work was partially supported by a DOD Grant No.; DOD W81XWH1010862.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗