Search NASA⌕ Search

SEARCH · Search NASA

Results for “Positioning Resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Utilizing ERTS-A imagery for tectonic analysis through study of Big Horn Mountains region

The author has identified the following significant results. MSS scene 1085-17294 of the Big Horn region has been subjected to detailed structural analysis. Band 7 is particularly good for revealing structural and drainage patterns because of enhance topographic detail and the subdued vegetational contrasts. Considerable stereo coverage through sidelap with adjoining scenes adds to the effectiveness of the study and has been used on both positive transparencies and enlarged prints. Negative prints of Band 7 positive transparencies have proven to be much more useful than positive prints because the higher resolution of the positive transparencies can be maintained. The Bighorn Mountains are crisscrossed by a number of prominent topographic linears, most of which can be correlated with known fault and shear zones in the Precambrian crystalline core. Many of these do not appear to continue into the flanking sedimentary rocks and a few that do (Tensleep, Tongue River lineaments) are very difficult to trace farther out into the basins. The Tongue River lineament, long a source of speculation and uncertainty as to its existence, appears as a very prominent discontinuity in the imagery.

Hoppin, R. A.↗

Fluorescence-type Monochromatic X-ray Beam-position Monitor with High-spatial Resolution for the NSLS-II Beamlines

We developed a fluorescence-type monochromatic X-ray beam-position monitor (X-BPM) with high-spatial resolution for end-station experiments at the initial project beamlines of the NSLS-II. We designed a ring array of multi-segmented Si PIN-junction photodiodes to use as a position sensor. Further, we integrated a low-noise charge-preamplification HERMES4 ASIC chip into an electronic readout system for photon-counting application. A series of precision measurements to characterize electronically the Si-photodiode sensor and the ASIC chip demonstrated that the inherent noise from the detector system is sufficiently low to meet our stringent requirements. Using a Gaussian beam, we parametrically modeled the optimum working distance to ensure the detector's best performance. Based upon the results from the parametric modeling, prototypes of the next versions of the X-BPM are being developed. In this paper, we describe the methodology for developing the new compact monochromatic X-ray BPM, including its instrumentation, detector modeling, and future plan.

43 PARTICLE ACCELERATORS↗

The new cold neutron chopper spectrometer at the Spallation Neutron Source: Design and performance

The design and performance of the new cold neutron chopper spectrometer (CNCS) at the Spallation Neutron Source in Oak Ridge are described. CNCS is a direct-geometry inelastic time-of-flight spectrometer, designed essentially to cover the same energy and momentum transfer ranges as IN5 at ILL, LET at ISIS, DCS at NIST, TOFTOF at FRM-II, AMATERAS at J-PARC, PHAROS at LANSCE, and NEAT at HZB, at similar energy resolution. Measured values of key figures such as neutron flux at sample position and energy resolution are compared between measurements and ray tracing Monte Carlo simulations, and good agreement (better than 20% of absolute numbers) has been achieved. The instrument performs very well in the cold and thermal neutron energy ranges, and promises to become a workhorse for the neutron scattering community for quasielastic and inelastic scattering experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Get the Picture?

Positive Systems has worked in conjunction with Stennis Space Center to design the ADAR System 5500. This is a four-band airborne digital imaging system used to capture multispectral imagery similar to that available from satellite platforms such as Landsat, SPOT and the new generation of high resolution satellites. Positive Systems has provided remote sensing services for the development of digital aerial camera systems and software for commercial aerial imaging applications.

Source record↗

Flight representative positive isolation disconnect

Resolutions were developed for each problem encountered and a tradeoff analysis was performed to select a final configuration for a flight representative PID (Positive Isolation Disconnect) that is reduced in size and comparable in weight and pressure drop to the developmental PID. A 6.35 mm (1/4-inch) line size PID was fabricated and tested. The flight representative PID consists of two coupled disconnect halves, each capable of fluid isolation with essentially zero clearance between them for zero leakage upon disconnect half disengagement. An interlocking foolproofing technique prevents uncoupling of disconnect halves prior to fluid isolation. Future development efforts for the Space Shuttle subsystems that would benefit from the use of the positive isolation disconnect are also recommended. Customary units were utilized for principal measurements and calculations with conversion factors being inserted in equations to convert the results to the international system of units.

Rosener, A. A.↗

Introducing minimum Fisher regularisation tomography to AXUV and soft x-ray diagnostic systems of the COMPASS tokamak

The contribution focuses on plasma tomography via the minimum Fisher regularisation (MFR) algorithm applied on data from the recently commissioned tomographic diagnostics on the COMPASS tokamak. The MFR expertise is based on previous applications at Joint European Torus (JET), as exemplified in a new case study of the plasma position analyses based on JET soft x-ray (SXR) tomographic reconstruction. Subsequent application of the MFR algorithm on COMPASS data from cameras with absolute extreme ultraviolet (AXUV) photodiodes disclosed a peaked radiating region near the limiter. Moreover, its time evolution indicates transient plasma edge cooling following a radial plasma shift. In the SXR data, MFR demonstrated that a high resolution plasma positioning independent of the magnetic diagnostics would be possible provided that a proper calibration of the cameras on an x-ray source is undertaken.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Plasmonic Force Propulsion Revolutionizes Nano/Picosatellite Capability

This project investigated a new type of small spacecraft propulsion for attitude control, specifically proximity and precision pointing control. Plasmonic force propulsion uses solar light focused on deep-subwavelength nanostructures to excite strong optical forces that accelerate and expel nanoparticle propellant. The goal of the project was to assess the feasibility of plasmonic force propulsion for nano/pico-satellite applications by evaluating key mission parameters for a nano/pico-satellite using plasmonic force propulsion in a NASA-relevant mission context. We achieved this goal and objective by evaluating plasmonic force propulsion within a NASA mission that required attitude control and precision pointing of a small satellite. We numerically simulated plasmonic force fields with asymmetric/gradient geometry and relevant solar light constraints, predicted nanoparticle velocity, mass flow rate, and resulting propulsion performance (thrust, specific impulse), and evaluated spacecraft position control resolution and pointing precision. Additionally we compared the precision pointing capabilities of plasmonic propulsion, as well as the mass, volume, and power requirements, with other state-of-the-art control techniques, such as reaction wheels and colloid/electrospray electric propulsion. The results are very exciting. Plasmonic force propulsion can significantly enhance the state-of-the-art in small spacecraft position and attitude control by 1-2 orders of magnitude. This is most succinctly shown in the figure below, which compares proximity and attitude control of plasmonic force propulsion (PFP) with other state-of-the-art thruster systems (μCAT, VAT, electrospray). Additionally this figure also shows the proximity and attitude control required for different existing (James Webb Space Telescope, Hubble) and future (LISA and Stellar Imager) NASA missions. While some of these NASA missions are not small spacecraft missions, the requirements serve to illustrate the fact that more precise proximity and attitude control will be required for future NASA science missions. Stellar imager is a proposed NASA missions that requires an extremely high pointing precision of 0.1 milliarcseconds (2.7x10(exp -7) deg.) for an ultraviolet telescope that has over 200× the resolution of the Hubble Space Telescope, is able to take images showing details on the surfaces of other stars, consists of 20-30 small "mirror sats" flying in formation to produce a giant mirror, and requires each mirror-sat to be placed with nanometer precision and control its attitude with milliarcsecond precision.

Rovey, Joshua L.↗

Local Sensitivities of the Gulf Stream Separationa

Abstract Robust and accurate Gulf Stream separation remains an unsolved problem in general circulation modeling whose resolution will positively impact the ocean and climate modeling communities. Oceanographic literature does not face a shortage of plausible hypotheses that attempt to explain the dynamics of the Gulf Stream separation, yet a single theory that the community agrees on is missing. In this paper, the authors investigate the impact of the deep western boundary current (DWBC), coastline curvature, and continental shelf steepening on the Gulf Stream separation within regional configurations of the Massachusetts Institute of Technology General Circulation Model. Artificial modifications to the regional bathymetry are introduced to investigate the sensitivity of the separation to each of these factors. Metrics for subsurface separation detection confirm the direct link between flow separation and the surface expression of the Gulf Stream in the Mid-Atlantic Bight. It is shown that the Gulf Stream separation and mean surface position are most sensitive to the continental slope steepening, consistent with a theory proposed by Melvin Stern in 1998. In contrast, the Gulf Stream separation exhibits minimal sensitivity to the presence of the DWBC and coastline curvature. The implications of these results to the development of a “separation recipe” for ocean modeling are discussed. This study concludes adequate topographic resolution is a necessary, but not sufficient, condition for proper Gulf Stream separation.

58 GEOSCIENCES↗

Impact of horizontal resolution on simulation of precipitation extremes in an aqua-planet version of the Community Atmosphere Model (CAM)

One key question regarding current climate models is whether the projection of climate extremes converges to a realistic representation as the spatial and temporal resolutions of the model are increased. Ideally the model extreme statistics should approach a fixed distribution once the resolutions are commensurate with the characteristic length and time scales of the processes governing the formation of the extreme phenomena of interest. In this study, a series of AGCM runs with idealized 'aquaplanet-steady-state' boundary conditions have been performed with the Community Atmosphere Model CAM3 to investigate the effect of horizontal resolution on climate extreme simulations. The use of the aquaplanet framework highlights the roles of model physics and dynamics and removes any apparent convergence in extreme statistics due to better resolution of surface boundary conditions and other external inputs. Assessed at a same large spatial scale, the results show that the horizontal resolution and time step have strong effects on the simulations of precipitation extremes. The horizontal resolution has a much stronger impact on precipitation extremes than on mean precipitation. Updrafts are strongly correlated with extreme precipitation at tropics at all the resolutions, while positive low-tropospheric temperature anomalies are associated with extreme precipitation at mid-latitudes.

54 ENVIRONMENTAL SCIENCES↗

mpfit: a robust method for fitting atomic resolution images with multiple Gaussian peaks

The standard technique for sub-pixel estimation of atom positions from atomic resolution scanning transmission electron microscopy images relies on fitting intensity maxima or minima with a two-dimensional Gaussian function. While this is a widespread method of measurement, it can be error prone in images with non-zero aberrations, strong intensity differences between adjacent atoms or in situations where the neighboring atom positions approach the resolution limit of the microscope. Here we demonstrate mpfit, an atom finding algorithm that iteratively calculates a series of overlapping two-dimensional Gaussian functions to fit the experimental dataset and then subsequently uses a subset of the calculated Gaussian functions to perform sub-pixel refinement of atom positions. Based on both simulated and experimental datasets presented in this work, this approach gives lower errors when compared to the commonly used single Gaussian peak fitting approach and demonstrates increased robustness over a wider range of experimental conditions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Study of precision weak-link stage systems with large travel range and sub-nanometer-scale resolution

To use x-ray optics with nanometer resolution limit, scanning x-ray nanoprobes with corresponding mechanical positioning capability need to be designed. In particular, positioning stages with both sub-nanometer resolution and a positioning/scanning range of several millimeters are required. Based on our design of precision weak-link stages with interferometric encoders for the Center for Nanoscale Materials (CNM) hard x-ray nanoprobe at the Advanced Photon Source (APS) Sector 26, we have developed a new two-dimensional (2-D) weak-link stage system for nanopositioning of a specimen holder. This system provides sub-nanometer resolution, coupled with sub-nanometer metrology at a travel range of several millimeters. The 2-D weak-link stage system is designed with high structure stiffness using laminar overconstrained weak-link mechanisms [4-6]. In this paper we present the study of a linear precision weak-link stage system with sub-centimeter travel range and sub-nanometer positioning resolution. Design of a rotary weak-link stage system with 10-nrad resolution and 10-degree-level travel range is also discussed in this paper.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Recent advances in well-based monitoring of CO2 sequestration

Recent CO{sub 2} sequestration pilot projects have implemented novel approaches to well-based subsurface monitoring aimed at increasing the amount and quality of information available from boreholes. Some of the drivers for the establishment of new well-based technologies and methodologies arise from: (1) the need for data to assess physical and geochemical subsurface processes associated with CO{sub 2} emplacement; (2) the high cost of deep boreholes and need to maximize data yield from each; (3) need for increased temporal resolution to observe plume evolution; (4) a lack of established processes and technologies for integrated permanent sensors in the oil and gas industry; and (5) a lack of regulatory guidance concerning the amount, type, and duration of monitoring required for long-term performance confirmation of a CO{sub 2} storage site. In this paper we will examine some of the latest innovations in well-based monitoring and present examples of integrated monitoring programs.

54 ENVIRONMENTAL SCIENCES↗

Development of ORRUBA: A Silicon Array for the Measurement of Transfer Reactions in Inverse Kinematics

The development of high quality radioactive beams has made possible the measurement of transfer reactions in inverse kinematics on unstable nuclei. Measurement of (d,p) reactions on neutron-rich nuclei yield data on the evolution of nuclear structure away from stability, and are of astrophysical interest. Experimentally, (d,p) reactions on heavy (Z=50) fission fragments are complicated by the strongly inverse kinematics, and relatively low beam intensities. Consequently, ejectile detection with high resolution in position and energy, a high dynamic range and a high solid angular coverage is required. The Oak Ridge Rutgers University Barrel Array (ORRUBA) is a new silicon detector array optimized for the measurement of (d,p) reactions in inverse kinematics.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Optimal integer resolution for attitude determination using global positioning system signals

In this paper, a new motion-based algorithm for GPS integer ambiguity resolution is derived. The first step of this algorithm converts the reference sightline vectors into body frame vectors. This is accomplished by an optimal vectorized transformation of the phase difference measurements. The result of this transformation leads to the conversion of the integer ambiguities to vectorized biases. This essentially converts the problem to the familiar magnetometer-bias determination problem, for which an optimal and efficient solution exists. Also, the formulation in this paper is re-derived to provide a sequential estimate, so that a suitable stopping condition can be found during the vehicle motion. The advantages of the new algorithm include: it does not require an a-priori estimate of the vehicle's attitude; it provides an inherent integrity check using a covariance-type expression; and it can sequentially estimate the ambiguities during the vehicle motion. The only disadvantage of the new algorithm is that it requires at least three non-coplanar baselines. The performance of the new algorithm is tested on a dynamic hardware simulator.

Crassidis, John L.↗

Lifetime measurement of the 6.79 MeV state in {sup 15}O with the AGATA demonstrator

The preliminary results of a new direct measurement of the lifetime of the first excited 3/2{sup +} state in {sup 15}O are discussed. An accurate evaluation of this lifetime is of paramount importance for the determination of the cross section of the {sup 14}N(p,{gamma}){sup 15}O reaction, the slowest one in the CNO cycle, at the energies of the solar Gamow peak. The {sup 2}H({sup 14}N,{sup 15}O)n reaction in inverse kinematics at 32MeV beam energy (XTU Tandem, LNL) was used to populate the level of interest, which decays via a 6.79 MeV E1 gamma-ray transition to the ground state. Gamma rays were detected with 4 triple clusters of HPGe detectors of the AGATA Demonstrator array. The energy resolution and position sensitivity of this state-of-the-art gamma-ray spectrometer have been exploited to investigate the Doppler Shift Attenuation effect on the lineshape of the gamma-ray peak in the energy spectrum. The deconvolution of the lifetime effects from those due to the kinematics of the emitting nuclei has been performed using detailed Monte Carlo simulations of the gamma emission and detection. CDCC-CRC calculations for the nucleon transfer process have been used for this purpose and preliminary results are shown.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

THE INTERMEDIATE-MASS BLACK HOLE CANDIDATE IN THE CENTER OF NGC 404: NEW EVIDENCE FROM RADIO CONTINUUM OBSERVATIONS

We present the results of deep, high-resolution, 5 GHz Expanded Very Large Array (EVLA) observations of the nearby, dwarf lenticular galaxy and intermediate-mass black hole candidate (M{sub BH} {approx} 4.5 Multiplication-Sign 10{sup 5} M{sub Sun }), NGC 404. For the first time, radio emission at frequencies above 1.4 GHz has been detected in this galaxy. We found a modestly resolved source in the NGC 404 nucleus with a total radio luminosity of 7.6 {+-} 0.7 Multiplication-Sign 10{sup 17} W Hz{sup -1} at 5 GHz and a spectral index from 5 to 7.45 GHz of {alpha} = -0.88 {+-} 0.30. NGC 404 is only the third central intermediate-mass black hole candidate detected in the radio regime with subarcsecond resolution. The position of the radio source is consistent with the optical center of the galaxy and the location of a known, hard X-ray point source (L{sub X} {approx} 1.2 Multiplication-Sign 10{sup 37} erg s{sup -1}). The faint radio and X-ray emission could conceivably be produced by an X-ray binary, star formation, a supernova remnant, or a low-luminosity active galactic nucleus powered by an intermediate-mass black hole. In light of our new EVLA observations, we find that the most likely scenario is an accreting intermediate-mass black hole, with other explanations being either incompatible with the observed X-ray and/or radio luminosities or statistically unlikely.

79 ASTRONOMY AND ASTROPHYSICS↗

A non-intrusive optical (NIO) approach to characterize heliostats in utility-scale power tower plants: Sensitivity study

Power towers, a type of concentrating power tower technology, use a large number of heliostats to concentrate sunlight and produce renewable energy. Optical errors of heliostats can cause drastic losses in the efficiency of power-tower plants. Accurately measuring optical errors is crucial to assessing and improving plant performance. This analysis discusses an innovate non-intrusive optical (NIO) approach to measure slope, canting, and tracking errors by detecting distortions in the reflected tower structure in heliostat images. Further in this work a sensitivity study is carefully conducted to determine the uncertainty requirements to allow the method to calculate slope errors with an accuracy of 0.25 mrad. Measurement uncertainty sources include camera resolution and position uncertainty, tower position uncertainty, and number of collected images. Each uncertainty source is investigated to determine its impact on the accuracy of the slope-error calculation. A combination of theoretical results and experimental results obtained from data collected on a heliostat at Sandia National Laboratories is used to determine and validate uncertainty requirements. The analysis shows that a measurement uncertainty of 0.25 mrad can be realized by realistically controlling uncertainty sources when implementing the NIO method. It demonstrates the superior performance of NIO in performing in-situ optical characterization.

14 SOLAR ENERGY↗