Search NASA⌕ Search

SEARCH · Search NASA

Results for “Posture”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Recommendations on the Use of Commercial-Off-The-Shelf (COTS) Electrical, Electronic, and Electromechanical (EEE) Parts for NASA Missions - Phase II

This assessment had two Phases. Phase I captured NASA Centers’ current practices for commercial-off-the-shelf (COTS) Electrical, Electronic, and Electromechanical (EEE) parts 1 used in spaceflight systems and ground support equipment (available at https://ntrs.nasa.gov/citations/20205011579) [ref. 1]. The Phase II report provides guidance for selecting and using COTS parts in NASA missions. The approaches proposed in this report differ from current agency practices. This top-level executive summary touches on these new approaches for using COTS parts but does not provide the detailed information that is critical in understanding the rationale behind these new approaches. Readers will need to read the entire report to gain full understanding and effectively use the recommendations herein. NASA’s historical approach to selecting and applying parts has been to define certain parts, primarily specific classes of military specification (MIL-SPEC) parts, as “standard”, leaving all others, including COTS parts, as nonstandard. Standard parts typically are used without further testing (“use-as-is”). Nonstandard parts are subjected to initial screening and subsequent lot acceptance testing of representative samples from each procured lot per MIL-SPEC or similar requirements. Decades later, top-tier commercial part manufacturers have evolved significant manufacturing, statistical control, and technological improvements that can now provide parts as reliable or more reliable than MIL-SPEC parts, when used within their datasheet limits. Concurrently, the space science and exploration community’s needs demand technological advances unavailable with MIL-SPEC parts. This ongoing change necessitates using COTS parts for space missions. Properly selected COTS parts in appropriate applications can offer performance and supply availability advantages compared to MIL-SPEC parts. Their utility and demonstrated reliability result from large volumes and automated production and testing processes. However, careful review and a thorough understanding of their specifications (i.e., datasheet limitations) is needed, and verifying that manufacturer specifications and reliability meet space hardware application needs are necessary. This report recommends MIL-SPEC screening and non-radiation-related lot acceptance testing be reduced or eliminated in cases where evidence of sufficient quality and reliability exists for COTS parts. The extent of NASA's insight into COTS manufacturers and the amount and nature of the needed evidence will differ by mission and will likely be driven by a mission's resources and associated risk posture. To facilitate this goal, two new terminologies have been defined and described: “Industry Leading Parts Manufacturer (ILPM)” and “Established COTS parts.” An ILPM is a COTS manufacturer that produces high quality and reliable parts. Some parts produced by ILPMs, defined as Established COTS parts, do not need any additional MIL-SPEC or NASA screening and lot acceptance testing to be used in space applications. This report provides guidance for selecting, procuring, and applying COTS parts and for performing part-, board-, and system-level COTS parts verification. The recommendation to select Established COTS parts from ILPMs will assure those COTS parts will have comparable quality to corresponding MIL-SPEC parts. Selecting, applying, and verifying Established COTS parts from ILPMs requires a holistic team approach, engaging parts engineers, circuit designers, quality, reliability, and systems engineers, procurement specialists, radiation specialists, avionics leads, and program/project managers. A mission-specific approach tailored to a project’s Mission, Environment, Applications and Lifetime (MEAL) [ref. 2] requirements should be developed and approved by program/project managers. Any associated risks should be clearly identified, quantified, mitigated, and/or accepted. Different approaches are recommended according to program/project Risk Classes A, B, C, and D [ref. 3] and human-rated missions [ref. 4]: 1. Recommend Classes A and B and human-rated missions consider a “MIL-SPEC parts- based design” approach. ”MIL-SPEC parts-based design” approach is one in which most parts are MIL-SPEC parts and Established COTS parts from ILPMs are used only when an equivalent MIL-SPEC part does not meet functional or size, weight, and power (SWaP) or performance requirements, or is not available. 2. Recommend Classes D and Sub-D missions consider a “System of COTS” approach. “System of COTS” approach is one which most parts are Established COTS parts from ILPMs. 3. Recommend Class C missions determine which approach is the best for their projects; that is, use either a “MIL-SPEC parts-based design” approach, “System of COTS” approach, or a combined approach utilizing elements of both. This report intends to provide guidance in using COTS parts for NASA missions with risk classifications of A through D and human-rated missions; but it does not address the costs of using COTS parts. Costs of using COTS parts in different NASA mission classes can vary significantly even if the same parts are used in different risk postures, due to differing verification levels needed. The guidance does not distinguish between critical or non-critical systems, and a given project will need to apply the appropriate guidance based on their risk posture. The intended audience of this report are NASA personnel and commercial practitioners who support NASA’s spaceflight missions, including spaceflight program or project managers, parts engineers, parts manufacturers, radiation engineers, avionics engineers, system engineers, circuit design engineers, reliability engineers, safety and mission assurance (SMA) personnel, and parts procurement specialists. The NEPP Program will perform a pathfinder study to explore implementing the guidance in this NESC report. An ILPM verification process is not the same as conventional vendor qualification processes performed according to military standards and specifications. This NESC report intends to provide guidance in utilizing available parts data from ILPM manufacturers for parts assurance assessments needed for NASA missions. The report also captured the current practices from DoD and Federal Aviation Administration (FAA) in Section 10. Note each DoD and FAA report was provided by the corresponding agencies regarding their practices, which are independent from the NESC recommendations in the report.

Commercial-Off-The-Shelf↗

3D Scanning System to Assess Gravity-Dependent Body Shape Changes

The human body shows unique physiological and morphological changes when exposed to different gravity conditions, including muscle atrophy, fluid shift, spinal elongation, and body posture adjustments. Such changes need to be incorporated for human-system integration in the vehicle habitat, garment, and spacesuit designs, as inaccurate body measurements can result in suboptimal crew protection that can potentially decrease injury tolerance. However, the traditional linear measurements, such as stature, segment lengths or circumferences measured using a caliper or tape measure, often show limited consistency and are unable to capture the nonlinear characteristics of the human body. While 3D body scanning can provide significant advantages over linear measurements, the technologies have not been fully developed or customized for in-flight scanning. For ground laboratory use, several different scanner types are commercially available. However, in-flight scanning requires additional technical considerations, such as minimal scan time, simplified calibration, and sufficient capture volume. This work aims to develop a prototype 3-D body scanning system that is customized for in-flight use to scan crewmembers, with the configuration and performance optimized for detecting known gravity-dependent body shape and posture changes. A hardware system will be custom built using a network of commercial off-the-shelf 3D sensors. The sensor parameters and settings will be optimized to detect the targeted body shape changes, specifically using body manikins of which the shape and size are iteratively permuted to simulate the known changes by fluid shift and spinal elongation. The capture volume will be also matched for a range of body sizes from a 1st percentile female to 99th percentile male. Unintentional body motions or floating in microgravity will be also simulated and incorporated. A data acquisition software will be developed for efficient in-flight operations with minimal overhead and easy-to-use user interface. A simplified calibration procedure will be designed for robust scanning against frequent vibration or unexpected sensor position shifts. The system will be tested in the ground laboratory for accuracy and reliability against a reference scanning system. New anthropometry measurements will be also identified to sensitively capture the gravity dependent body shape changes, in addition to the traditional anthropometry measurements. A novel landmark-based technique will be tested for consistent anthropometry measurements across posture variations. If successfully developed and deployed, the new system is expected to provide previously unavailable body shape and size data from different gravitational environments, including 0-g, 1/6-g, and 1-g. Such data can improve suit fit, habitat design, exercise efficacy quantification and sizing of orthostatic intolerance garments.

K H Kim↗

Effect of Varying HUT Sizing on Human-Spacesuit Contact Patterns

Fit, comfort, and mobility of the spacesuit rely on the location, magnitude, and type of contact between the suit and wearer. Typically, spacesuits include the Hard Upper Torso (HUT) comprising the upper torso of the spacesuit. Potential injuries from hard contact between the wearer’s shoulders and the HUT are a concern; therefore, to investigate spacesuit-wearer contact patterns, data from a retrospective study was analyzed. This study had eight subjects wearing the Shuttle Extravehicular Mobility Unit (EMU) spacesuit in two configurations, one with a nominally sized HUT and another with an oversized HUT. The subjects were sized per the NASA standard suit fit procedure. The suit’s arms and lower body were also resized to provide nominal arm and lower body fit, accounting for the larger HUT. Subjects held various shoulder postures (neutral posture, and various maximum shoulder rotations) with the suit pressurized to 4.3 PSI. For each posture, subjects reported the intensity of their perceived contact with the suit on a Borg CR10 scale, 0 indicating a non-existent contact intensity, and 10 representing a maximal contact intensity. Ratings were recorded for 11 regions covering the upper body and these ratings were used to determine the impact of body shape and size on suit contact. Our preliminary findings suggest that oversized HUTs had less contact regions than compared to the nominal HUT; and the region of contact, contact patterns, and contact intensities varied from person to person with the oversized HUT. This variance could be linked to subjects’ body shape and size. The next goal is to establish a causal factor between body shape and size, pose, contact region, and the HUT size. The outcome is expected to help understand the overall contact trends and insights into the influence of HUT sizing on suit fit.

Will Green↗

3D Scanning System to Assess Gravity-Dependent Body Shape Changes

The human body shows unique physiological and morphological changes when exposed to different gravity conditions, including muscle atrophy, fluid shift, spinal elongation, and body posture adjustments. Such changes need to be incorporated for human-system integration in the vehicle habitat, garment, and spacesuit designs, as inaccurate body measurements can result in suboptimal crew protection that can potentially decrease injury tolerance. However, the traditional linear measurements, such as stature, segment lengths or circumferences measured using a caliper or tape measure, often show limited consistency and are unable to capture the nonlinear characteristics of the human body. While 3D body scanning can provide significant advantages over linear measurements, the technologies have not been fully developed or customized for in-flight scanning. For ground laboratory use, several different scanner types are commercially available. However, in-flight scanning requires additional technical considerations, such as minimal scan time, simplified calibration, and sufficient capture volume. This work aims to develop a prototype 3-D body scanning system that is customized for in-flight use to scan crewmembers, with the configuration and performance optimized for detecting known gravity-dependent body shape and posture changes. A hardware system will be custom built using a network of commercial off-the-shelf 3D sensors. The sensor parameters and settings will be optimized to detect the targeted body shape changes, specifically using body manikins of which the shape and size are iteratively permuted to simulate the known changes by fluid shift and spinal elongation. The capture volume will be also matched for a range of body sizes from a 1st percentile female to 99th percentile male. Unintentional body motions or floating in microgravity will be also simulated and incorporated. A data acquisition software will be developed for efficient in-flight operations with minimal overhead and easy-to-use user interface. A simplified calibration procedure will be designed for robust scanning against frequent vibration or unexpected sensor position shifts. The system will be tested in the ground laboratory for accuracy and reliability against a reference scanning system. New anthropometry measurements will be also identified to sensitively capture the gravity dependent body shape changes, in addition to the traditional anthropometry measurements. A novel landmark-based technique will be tested for consistent anthropometry measurements across posture variations. If successfully developed and deployed, the new system is expected to provide previously unavailable body shape and size data from different gravitational environments, including 0-g, 1/6-g, and 1-g. Such data can improve suit fit, habitat design, exercise efficacy quantification and sizing of orthostatic intolerance garments.

K H Kim↗

An Evaluation of The Dynamic Physical Security Risk Assessment Methodology for Fleet-Wide Applications

The requirements for U.S. nuclear power plants to maintain a large onsite physical security force contribute to their high operational costs. The cost of maintaining the current physical security posture is approximately 10% of the overall operation and maintenance budget for commercial nuclear power plants. The goal of the Light Water Reactor Sustainability (LWRS) program’s physical security pathway is to develop tools, methods, and technologies and provide the technical basis for an optimized physical security posture. The conservatisms built into current security postures may be analyzed and minimized to reduce security costs while still ensuring adequate security and operational safety. The research performed at Idaho National Laboratory within LWRS program’s physical security pathway has successfully developed a dynamic force-on-force modeling framework using various computer simulation tools and integrating them with the dynamic assessment Event Modeling Risk Assessment using Linked Diagrams (EMRALD) tool. This integrated process for physical security analysis is named Modeling and Analysis for Safety Security using Dynamic EMRALD Framework (MASS-DEF). This document provides an update on the progress in applying the MASS-DEF process to an operating commercial nuclear power plant as well as additional industry feedback regarding use of the tool for other physical security risk-informed topics. This report is only a summary of the progress and does not contain specific modeling results as those contain sensitive security information. Previous reports described how a user could integrate their plant-specific force-on-force models with the dynamic simulation tool EMRALD, model operator actions, and integrate with probabilistic risk assessment tools, such as CAFTA (Computer Aided Fault Tree Analysis System) or SAPHIRE (Systems Analysis Programs for Hands-on Integrated Reliability Evaluations), and with thermal-hydraulic tools, such as RELAP-5 or MAAP. Previous reports applied various combinations of available simulations codes with EMRALD using generic plant models to demonstrate how to perform the analysis. This report is an update the progress of applying the dynamic computational framework to an actual nuclear facility using their security scenarios and timelines. This report also provides an update to the procedural guidance for the MASS-DEF process and an overview of the generic models available for use by utilities. This report does not contain any plant’s sensitive information and/or safeguards information. This study’s purpose was to verify that the results achieved using generic models are similar to actual plant results and refine our guidance on the use of the framework. This assessment enables further analysis, such as what-if scenarios and staff-reduction evaluation, thereby optimizing physical security at plants.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Influence of central set on anticipatory and triggered grip-force adjustments

The effects of predictability of load magnitude on anticipatory and triggered grip-force adjustments were studied as nine normal subjects used a precision grip to lift, hold, and replace an instrumented test object. Experience with a predictable stimulus has been shown to enhance magnitude scaling of triggered postural responses to different amplitudes of perturbations. However, this phenomenon, known as a central-set effect, has not been tested systematically for grip-force responses in the hand. In our study, predictability was manipulated by applying load perturbations of different magnitudes to the test object under conditions in which the upcoming load magnitude was presented repeatedly or under conditions in which the load magnitudes were presented randomly, each with two different pre-load grip conditions (unconstrained and constrained). In constrained conditions, initial grip forces were maintained near the minimum level necessary to prevent pre-loaded object slippage, while in unconstrained conditions, no initial grip force restrictions were imposed. The effect of predictable (blocked) and unpredictable (random) load presentations on scaling of anticipatory and triggered grip responses was tested by comparing the slopes of linear regressions between the imposed load and grip response magnitude. Anticipatory and triggered grip force responses were scaled to load magnitude in all conditions. However, regardless of pre-load grip force constraint, the gains (slopes) of grip responses relative to load magnitudes were greater when the magnitude of the upcoming load was predictable than when the load increase was unpredictable. In addition, a central-set effect was evidenced by the fewer number of drop trials in the predictable relative to unpredictable load conditions. Pre-load grip forces showed the greatest set effects. However, grip responses showed larger set effects, based on prediction, when pre-load grip force was constrained to lower levels. These results suggest that anticipatory processes pertaining to load magnitude permit the response gain of both voluntary and triggered rapid grip force adjustments to be set, at least partially, prior to perturbation onset. Comparison of anticipatory set effects for reactive torque and lower extremity EMG postural responses triggered by surface translation perturbations suggests a more general rule governing anticipatory processes.

Non-NASA Center↗

Relation of blood volume and blood pressure in orthostatic intolerance

A complex but crucial relationship exists between blood volume and blood pressure in human subjects; it has been recognized that in essential hypertension, renovascular hypertension, and pheochromocytoma, the relationship between plasma volume and diastolic blood pressure is an inverse one. This phenomenon has not been studied in individuals with low normal and reduced blood pressures. Orthostatic intolerance is a commonly encountered abnormality in blood pressure regulation often associated with tachycardia in the standing position. Most of these patients have varying degrees of reduced blood volume. We tested the hypothesis that the relationship previously found between plasma volume and diastolic blood pressure in pressor states would also hold in orthostatic intolerance. We studied 16 patients with a history of symptomatic orthostatic intolerance associated with an elevation in plasma norepinephrine in the upright posture and hypovolemia in 9 patients and normovolemia in 7 patients. Our studies demonstrate an inverse relationship between plasma volume and diastolic blood pressure in patients with orthostatic intolerance. This finding also holds for the change in diastolic blood pressure in response to upright posture. In this relationship, patients with orthostatic intolerance with high plasma norepinephrine resemble those with essential hypertension, renovascular hypertension, and pheochromocytoma. We conclude that in a variety of conditions at both ends of the blood pressure spectrum, the seemingly paradoxical association of hypovolemia and diastolic blood pressure is preserved.

NASA Discipline Regulatory Physiology↗

Effect of upright tilt on ventricular/vascular coupling in chronically instrumented primates

Studies of the hydraulic loading conditions on the heart in humans, especially pulsatile load, have primarily been limited to the supine state. Therefore, we have chosen a nonhuman primate model, the baboon, to assess left ventricular/vascular coupling in both supine and upright positions. Primate subjects were studied by catheterization under sedation and then after surgical implantation of transducers. This allowed the evaluation of postural stress in the chronically instrumented conscious baboon and then after light dissociative doses of ketamine. Basic hemodynamic variables were evaluated for baboons in supine and upright positions. Fourier analysis was applied to aortic pressure and flow to obtain input and characteristic impedance and the ratio of pulsatile (Wp) to total (Wt) left ventricular power (Wp/Wt). The aortic reflected, or backward, pressure was also calculated. Peripheral resistance increased (P = 0.01) and reflected pressure decreased (17.74 +/- 1.50 vs. 15.21 +/- 2 mmHg; P < 0.01) in upright subjects. Characteristic impedance and Wp/Wt were unchanged. Postoperatively, peripheral resistance increased (2,651 +/- 311 vs. 3,667 +/- 276; P < 0.05) and mean power and Wt decreased (P < 0.01) without changes in reflected pressure. All variables were unchanged after light dissociative doses of ketamine. Thus there is no significant change in efficiency of left ventricular/vascular coupling formulated in terms of Wp/Wt or input impedance with postural stress.

NASA Program Space Physiology and Countermeasures↗

Implementing an Objectives-Driven, Risk-Informed, and Case-Assured Approach to Safety and Mission Success at NASA

NASA is developing a “Standard for Assurance of Space Flight Safety and Mission Success” that implements an objectives-driven, risk-informed, and case-assured approach to safety and mission success (S&MS) for NASA space flight programs and projects. The standard aligns with the philosophy of risk leadership that has recently been established in NASA policy to assure acceptable levels of flight crew safety and mission success risk. It is consistent with existing NASA risk management requirements and is compatible with NASA program management and systems engineering requirements. The methodology described in the standard is presented in terms of an S&MS assurance framework that is designed to allow substantial flexibility in the specific means by which programs and projects achieve acceptable mission S&MS risk. Such flexibility is necessary to accommodate the increasingly broad range of acquisition strategies employed by NASA, including commercial transportation services, as well as to accommodate the increasingly rapid evolution of space flight-related technologies and practices. A key feature of the S&MS assurance framework is the specification of S&MS success criteria for each life-cycle review (LCR). The S&MS assurance case is structured around these criteria, the satisfaction of which indicates that the program/project is adhering to the S&MS risk posture. This enables the evolving S&MS assurance case to be used as a fundamental program/project submittal at each LCR, where its inherent structure of argument, supported by evidence, directly supports the evaluation of the program/project with respect to the S&MS success criteria, and by extension, the S&MS risk posture. As such, the S&MS assurance case is integral to program/project systems engineering, risk management, and S&MS oversight activities, and provides the principal basis for S&MS risk acceptance by the Decision Authority throughout the program/project life cycle.

Risk Posture↗

FEMP Cybersecurity Arsenal

The FEMP Cyber Security Arsenal is a family of cyber security tools for the federal facility owners and operators. Using these tools, facility owners can evaluate their overall cybersecurity posture. These tools are web-based front-end tools. The tools are meant to help federal owners and operators to evaluate their overall cybersecurity posture. These tools are developed based on the NIST Cybersecurity framework, risk management framework, and DOE C2M2 architectures. Version 3 provides significant updates and features in ten areas

Ashley, Travis [Pacific Northwest National Laborat↗

Land-Based Wind Reference Architecture

This report describes a summary and the final deliverables for the Wind Reference Architecture project funded by the Department of Energy's (DOE) Wind Energy Technology Office (WETO). The project objective was to further refine the reference architecture of the existing wind power plant reference architecture developed by Idaho National Laboratory (INL) and Sandia National Laboratories (SNL) by expanding the wind turbine generator (WTG) into a separate individual wind turbine reference architecture. Additional details regarding the wind turbine system and how it integrates with a wind power plant were researched and reflected in the reference architecture. This addition is important because it allows researchers to understand the components and devices in a wind turbine, how they function and how a wind turbine integrates into a wind power plant to be able to perform cybersecurity evaluations on the system. The communication and control systems were the focus while developing this reference architecture to understand the cybersecurity posture of a wind turbine and power plant. The information technology (IT) and operational technology (OT) systems perspective are integral in helping improve the cybersecurity posture by creating a starting point to study how wind energy can be safely designed and deployed in our power grid from an integrated systems standpoint. A holistic wind power plant and turbine reference architecture and simulation was developed and made open-sourced for further research efforts.

17 WIND ENERGY↗

A model describing vestibular detection of body sway motion.

An experimental technique was developed which facilitated the formulation of a quantitative model describing vestibular detection of body sway motion in a postural response mode. All cues, except vestibular ones, which gave a subject an indication that he was beginning to sway, were eliminated using a specially designed two-degree-of-freedom platform; body sway was then induced and resulting compensatory responses at the ankle joints measured. Hybrid simulation compared the experimental results with models of the semicircular canals and utricular otolith receptors. Dynamic characteristics of the resulting canal model compared closely with characteristics of models which describe eye movement and subjective responses to body rotational motions. The average threshold level, in the postural response mode, however, was considerably lower. Analysis indicated that the otoliths probably play no role in the initial detection of body sway motion.

Nashner, L. M.↗

Effects of simulated artificial gravity on human performance

The ability of test subjects to perform operational type tasks was evaluated at rotational rates to 6 rpm and radii to 78 ft (24 m). The tasks included fine motor activity, mental operations, postural equilibrium, cargo handling, radial and tangential locomotion. Performance data indicate that 6 rpm presents a physiological limit at radii to 75 ft (23 m). Radial locomotion was not found to produce excessive adverse stimuli, and tangential locomotion was readily accomplished at walking rates of 2 of 4.8 ft/s (.6 to 1.4 m/s). The absence of vision dramatically reduced an individual's postural equilibrium during rotation. The use of selected anti-motion pharmaceuticals had, generally, a positive effect upon psychomotor performance at 6 rpm, but did not prove to be a panacea for the adverse effects of rotation at this rate.

Green, J. A.↗

Hemodynamics, renal function, plasma renin, and aldosterone in man after 5 to 14 days of bedrest

Continuous bedrest for 5 to 14 days had no significant effect on resting heart rate, blood pressure, or cardiac output in six normal men. Head-up tilt induced greater tachycardia in 5 of 6 patients after bed rest than in the control period. Propranolol diminished both tachycardia and the incidence of hypotension and faintness in upright posture. Plasma volume fell, extracellular fluid volume increased, and plasma renin activity was significantly elevated following bedrest. Unusually large increases in plasma renin followed head-up tilt or administration of isoproterenol during bedrest and after resuming normal activity. During bedrest, plasma aldosterone was often increased in the early morning. It is concluded that after bedrest, upright posture evokes strong beta-adrenergic activity as well as exaggerated metabolic and circulatory responses which can be reduced or abolished by the beta-adrenergic blocker, propranolol.

Melada, G. A.↗

Some influences of touch and pressure cues on human spatial orientation

In order to evaluate the influences of touch and pressure cues on human spatial orientation, blindfolded subjects were exposed to 30 rmp rotation about the Z-axis of their bodies while the axis was horizontal or near horizontal. It was found that the manipulation of pressure patterns to which the subjects are exposed significantly influences apparent orientation. When provided with visual information about actual orientation the subjects will eliminate the postural illusions created by pressure-cue patterns. The localization of sounds is dependent of the apparent orientation and the actual pattern of auditory stimulation. The study provides a basis for investigating: (1) the postural illusions experienced by astronauts in orbital flight and subjects in the free-fall phase of parabolic flight, and (2) the spatial-constancy mechanisms distinguishing changes in sensory afflux conditioned by a subject's movements in relation to the environment, and those conditioned by movements of the environment.

Lackner, J. R.↗

Man and machine design for space flight

The factors involved in creating effective designs for living and working in a weightless environment are discussed. Among the areas covered are special provisions for eating and drinking, a special shower nozzle to remove soap, electric shavers designed for vacuum containment of the clippings, and the need for restraint systems at the crew's workstations. Attention is given to the fact that the crewmen assume a neutral body posture in weightlessness which is an important consideration in designing displays, controls, and windows. It is concluded that the incorporation of the change in body posture and the requirement for restraint into future designs will greatly facilitate the crewman's task in the weightless environment.

Louviere, A. J.↗

Decision Aids for Airborne Intercept Operations in Advanced Aircrafts

A tactical decision aid (TDA) for the F-14 aircrew, i.e., the naval flight officer and pilot, in conducting a multitarget attack during the performance of a Combat Air Patrol (CAP) role is presented. The TDA employs hierarchical multiattribute utility models for characterizing mission objectives in operationally measurable terms, rule based AI-models for tactical posture selection, and fast time simulation for maneuver consequence prediction. The TDA makes aspect maneuver recommendations, selects and displays the optimum mission posture, evaluates attackable and potentially attackable subsets, and recommends the 'best' attackable subset along with the required course perturbation.

Madni, A.↗