Search NASA⌕ Search

SEARCH · Search NASA

Results for “Power system transient stability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

285 records · Page 16

Analog-Computer Investigation of Effects of Friction and Preload on the Dynamic Longitudinal Characteristics of a Pilot-Airplane Combination

With an electric analog computer, an investigation has been made of the effects of control frictions and preloads on the transient longitudinal response of a fighter airplane during abrupt small attitude corrections. The simulation included the airplane dynamics, powered control system, feel system, and a simple linearized pseudopilot. Control frictions at the stick pivot and at the servo valve as well as preloads of the stick and valve were considered individually and in combinations. It is believed that the results which are presented in the form of time histories and vector diagrams present a more detailed illustration of the effects of stray forces and compensating forces in the longitudinal control system than has previously been available. Consistent with the results of previous studies, the present results show that any of these four friction and preload forces caused some deterioration of the response. However, even a small amount of valve friction caused an oscillatory pitching response during which the phasing of the valve friction was such that it caused energy to be fed into the pitching oscillation of the air-plane. Of the other friction and preload forces which were considered, it was found that stick preload was close to 180 deg. out of phase with valve friction and thus could compensate in large measure for valve friction as long as the cycling of the stick encompassed the trim point. Either stick friction or valve preload provided a smaller stabilizing effect primarily through a reduction in the amplitude of the resultant force vector acting on the control system. Some data were obtained on the effects of friction when the damping or inertia of the control system or the pilot lag was varied.

Crane, Harold L.↗

Thermal Assessment of Swift BAT Instrument Thermal Control System in Flight

THE BAT is the primary instrument on the Swift spacecraft. The Swift mission is part of the National Aeronautics and Space Administration (NASA) Medium-Size Explorer (MIDEX) Program, and is managed by Goddard Space Flight Center (GSFC). It is designed to detect gamma ray burst over a broad region of the sky in a low Earth orbit of 600-km altitude and quickly align the telescopes on the spacecraft to the gamma ray source. It was successfully launched into orbit on November 20, 2004. The Swift mission is a first of its kind of multi-wavelength transient observatory for gamma ray burst astronomy. Its mission life is 2 years. The inclination is 22 deg maximum. The spacecraft bus voltage to the instruments is in the 24 V to 35 V range. The instruments will be turned off when the voltage is below 27 V. The BAT is mounted to the optical bench through five titanium flexures. The BAT has been developed at GSFC. Its telescope assembly consists of 256 Detector Modules (DMs) in the Detector Array. There are 16 Detector Array Blocks. Each Block holds 16 DMs, 3 Block Voltage Regulator (BVR) units and 3 Block Command & Data Handling (BCDH) units. The power dissipation of each Block has been measured to be 13 W. Therefore the total power dissipation of the 16 Blocks is 208 W. The DAP is 1.3 m (4.3 ft) x 1 m (3.3 ft), accommodates all the 16 Blocks. It also provides the mounting surface and the positional stability for the Blocks. The DMs are located at the top (+X side) of the DAP and is enclosed by graded-Z shields on the sides and a coded mask at the top. The BVRs and BCDHs are located at the bottom (-X side) of the DAP. Eight Blocks are located at the front (-Z side or radiator side) of the DAP, and eight are located at the rear (+Z side) of the DAP. The DMs and top of DAP are insulated with a 7-layer multi-layer insulation (MLI). There is a 5.08 cm (2 in) x 5.08 cm (2 in) MLI cutout over each Block heater controller so that heat radiates from the heater controller to the mask. The exterior of the mask, graded-Z shields and bottom of DAP is insulated with a 15-layer MLI.

Choi, Michael K.↗

Experimental Characterization Test of a Grid-Forming Inverter for Microgrid Applications

Standardized experimental testing protocols for grid forming (GFM) inverters to ensure expected operation under both normal and contingency conditions do not exist. Such protocols increase the confidence of system owner/operators that an inverter deployed in a proposed system will engage in typical behaviors to ensure interoperability with other units and ancillary equipment (e.g. protection equipment). This paper presents systematic and comprehensive test protocols to evaluate the performance of GFM inverters under the following operational configurations: islanded operation, heterogeneous islanded operation (parallel with a synchronous generator), grid-connected operation, and transition operation. A commercial GFM inverter is used to verify the test protocols and to understand the inverter's performance and functionalities. In particular, required configuration and tuning of the inverter will be explained in the full paper to enrich the testing protocol.

black start↗

Pressure Gain, Stability, and Operability of Methane/Syngas Based RDEs Under Steady and Transient Conditions (Final Project Report)

The scope of this work addresses key issues associated with losses associated with the detonation wave and other processes internal to the RDE operation, as well as it develops modeling tools for the evaluation of these losses and exhaust emissions in RDEs. The main challenge in studying RDEs is that RDE performance is highly reliant on the specifics of the design so much so that simple/canonical systems alone cannot provide useful engineering information, but practical RDE designs are sufficiently complex and involve extreme operational environments that detailed access either experimentally (laser diagnostics, for instance) or computationally (direct numerical simulations) are as yet to become practical. To overcome this challenge, we have conducted a combined experimental/simulation/analytical study investigating key phenomena that control the characteristics of operation of RDEs. As a result, the study has developed tools and methods that can be used to evaluate performance and design approaches using reduced-physics models, with the assumptions validated using detailed simulations, and the model prediction tested using experimental observations. The specific objectives of the research were: (1) Develop and demonstrate a low-loss fully axial injection concept, taking advantage of stratification effects to alter the detonation structure and position the wave favorably within the combustor; (2) Obtain stability and operability characteristics of an RDE across operating conditions to aid in the development of operability and performance rules for the operations of other systems; and (3) Develop quantitative metrics for performance gain as well as quantitative description of the loss mechanisms through a combination of diagnostics development, reduced-order modeling, and detailed simulations. The work conducted here has made contribution on design of low-loss inlets that has broad application within the power generation industry for use with pressure gain combustion. The operability and stability of different designs, while focusing on axial air inlet designs, has been analyzed. The effect of nozzle and injection conditions was studied. Models and simulations of exhaust emissions, focusing on NOx emission has been developed and used to investigate how operation of the RDE affect NOx production using Lagrangian analysis of RDE simulations. This work has built on previous programs, with the goal of further understanding operation of RDEs and elevate the readiness of design consideration. In addition, a suite of diagnostic and modeling tools have been developed to obtain quantitative metrics on performance based on measurements, which can be readily transferred to other experimental configurations.

08 HYDROGEN↗

Grid Resiliency with a 100% Renewable Microgrid

San Diego Gas & Electric Company (SDG&E) installed America’s first and largest utility-scale microgrid in Borrego Springs in 2013. The first generation Borrego Springs Microgrid utilized diesel generators to form and stabilize the microgrid island, with support from grid-scale batteries and local solar photovoltaic (PV) generation. In this project, SDG&E in partnership with National Renewable Energy Laboratory (NREL) demonstrated through modeling, simulation and utility field testing that blackstart and islanding of the microgrid can be led with 100% renewable, inverter based resources (IBRs), to help reduce community reliance on conventional generation resources. Through equipment upgrades, grid-forming island leader capability was transitioned to a battery IBR instead of the Borrego Springs Microgrid diesel generators. A new microgrid controller was integrated to the microgrid and programmed to control and manage multiple energy storage systems. Synchrophasor and other power quality data verified autonomous, high-speed response of the IBRs through blackstart, islanding, and load step testing. Results of project field evaluations provide distribution systems operators (DSO) with increased confidence that renewable, IBR can replace traditional generators to blackstart and island microgrids and rapidly establish stable island frequency with rapid changes in peak power demand. Importantly, the project validated the integration feasibility of a distributed energy resource management system (DERMS) controller that manages multiple grid-forming and grid-following IBRs, establishing a standard design interface to reduce the complexity of integrating new DERs in the future and supporting replication by the industry. As a result of learnings in this project, SDG&E has implemented the microgrid controller strategy at multiple other microgrid sites, thereby validating the replicability of the solution. Hardware-in-the-loop (HIL) simulations including power and controller HIL hardware — along with electromagnetic transient (EMT) simulations of Borrego Springs Microgrid —informed adjustments to inverter parameters and were important to characterize the performance of the IBRs in relevant operating conditions before deployment. The EMT and HIL simulations of islanding the entire community are important contributions in providing confidence in IBR performance prior to future islanding of the community in the field. High-fidelity EMT and/or HIL simulation of IBRs can de-risk field operations, and its relevance and importance as a tool is increasing as distribution grids and microgrids become more complex and dynamic with an increasing proportion of renewable generation, distributed energy storage, and two-way power and energy flows.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Integration of Storage in the DC Link of a Full Converter-Based Distributed Wind Turbine

Energy storage is known to support the dispatchability of variable renewable resources. In this paper, we model a battery energy storage system (BESS) integrated with the DC link of a Type IV full converter-based wind turbine and the necessary controls to achieve efficient dispatch. To support the validation of control methodologies, we build a detailed model of a Type IV research wind turbine at the National Renewable Energy Laboratory (NREL), the Controls Advanced Research Turbine (CART 3), and we integrated a lithium-ion BESS model in grid-following mode into the model. The simulation results illustrate the sizing and control of the DC link-integrated BESS for a given variable wind resource and varying dispatch strategies (i.e., under constant, uncertain, and ramping wind scenarios). The integrated storage can smooth variabilities in distributed wind output, hedge against uncertainties, provide the ramping capability, as well as support stability under voltage and frequency transients. All of these have been illustrated in MATLAB/Simulink.

DC-link voltage↗

Reliability and Safety Assessment of Urban Air Mobility Concept Vehicles

The following work was commissioned by the National Aeronautics and Space Administration (NASA) to guide industry and future regulation related to urban air mobility (UAM). Prior studies compared the relative safety of NASA concept vehicles, Figure ES1, designed for UAM and provided recommendations for industry research, aircraft architectural improvements, and regulatory updates. After the prior study completed, the European Aviation Safety Agency (EASA) released regulatory guidance in the form of a special condition (SC), SC-VTOL-01, for multirotors with distributed propulsion and flight controls (DPFC). The objective of the current work was to develop DPFC architectures that will comply with SC-VTOL-01. Vehicle designs, DPFC architectures, and stability & control (S&C) models were developed to find limitations and trends to guide industry. To guide this task, NASA developed quad, hex, and an octorotor to better define vehicle attributes and trade space. Aircraft for study included electric, hybrid-electric, and turboshaft powerplants and collective and RPM control schemes. Assessments are in terms of the safety level achieved, and/or aircraft component/features needed to meet SC-VTOL-01. The most challenging criteria being the catastrophic failure rate, ≤10-9 catastrophic failures per flight hour, and that no single failures may result in a catastrophic event. A disciplined process was followed, similar to that in Aerospace Recommended Practice (ARP) 4761. A preliminary system safety assessment (PSSA) leveraged prior work as a basis of creating failure rate budgets for system design teams. System designs were updated and iterated upon, working with reliability and safety subject matter experts to develop SC-VTOL-01 compliant designs. Design changes were reflected in updated PSSAs for initial verification of compliance. The DPFC architecture was broken into four system design teams, the (1) flight control system (FCS), (2) drive and power system, (3) thermal management system (TMS), and (4) electrical power and distribution system. The FCS including elements necessary to control the aircraft, drive and power including elements necessary to generate and transmit shaft power, the TMS including elements necessary to maintain temperature limits in all operating environments, and electrical pow-er and distribution including equipment necessary to store and transmit electrical energy. Results found that all aircraft evaluated may have paths to comply with SC-VTOL-01, Figure ES2. However, S&C models showed large power transients that must be addressed and PSSA results show that future work is needed in single load path structures, high voltage power storage and distribution, and in motor/rotor overspeed protection.

Boeing↗

High-Fidelity and High-Performance Computational Simulations for Rapid Design Optimization of Sulfur Thermal Energy Storage

Industrial process heating (IPH) accounts for approximately 70% of US manufacturing energy use and is primarily produced by fossil fuel combustion. Approximately 1500 TWht (approximately 60%) of IPH demand is in the temperature range of 100-300. Industrial applications in this temperature range include drying, hydrothermal processing, thermal enhanced oil recovery, food and beverage, bioethanol production, etc. Cost-effective thermal energy storage (TES) that increases the utilization of waste and renewable heat (solar, geothermal, etc.) could provide significant energy savings and reliable heat sources, decrease emissions, and increase US manufacturing competitiveness through reductions in fuel consumption. TES development has historically been dominated by technologies suitable for deployment with concentrating solar power (CSP). State-of-the-art thermal storage deployed commercially with power tower CSP plants uses a 60%/40% NaNO3/KNO3 molten salt and operates between temperatures of approximately 280 degrees Celsius and 570 degrees Celsius using a two-tank configuration. However, these nitrate salts are unsuitable for operation outside of this temperature range due to a high freezing point of approximately 220 degrees Celsius, and limits on high-temperature salt stability and corrosion resistance of containment alloys. Other materials being investigated for TES include those based on: (1) sensible energy storage (various molten salt compositions, inert solid particles, rocks or pebble beds, sulfur, water, concrete, graphite, etc.), (2) latent energy storage in materials that undergo solid-liquid phase change at relevant temperatures (organic materials for low-temperature applications, inorganic salts and/or metals for high-temperature applications), or (3) thermochemical energy storage (hydrides, hydroxides, carbonates, metal oxides, etc.). The application temperature and challenges pertaining to storage material and/or containment cost, energy density, long-term thermal and cyclic stability, and charge/discharge heat transfer effectiveness drive material selection for a given IPH or electricity generation application. Sulfur is a cheap commodity at $80/ton compared to $1100 - 1300/ton for conventional salts. When using a metric of storage cost per kWh, sulfur costs around 2-3 $/kWh. Previous sulfur TES development focused on high temperature (>600 degrees) concentrated solar power applications with sulfur encapsulated in pipes and flow of gaseous HTF (air) in the shell side. However, for lower-temperature IPH applications in the range of approximately 100-300 degrees Celsius Element 16 adopted a compact and scalable TES design with molten sulfur in the shell and HTF pipes submerged in the molten sulfur bath. The low-cost molten sulfur TES for dispatchable IPH has deployment potential for broad applications. The spatial and temporal evolution of the HTF and sulfur temperature is critical to the TES system performance, and thus detailed modeling can improve understanding of the performance and facilitate design improvements. Using high performance computing and computational fluid dynamics (CFD) a low-cost molten sulfur thermal energy storage (TES) system for industrial process heating (IPH) applications was developed. The unique challenges in CFD modeling of sulfur TES are the sharp property changes of sulfur relevant to the working temperatures. Above 159, liquid sulfur undergoes polymerization, and the viscosity of sulfur rapidly increases by several orders of magnitude between 159 degrees Celsius and 188 degrees Celsius, followed by a decrease in viscosity beyond 188 degrees Celsius due to thermal bound dissociation. In addition, various concentrations of H2S impurities can also modify sulfur viscosity. This numerical challenge is especially relevant to transient simulation of the sulfur TES charging and discharging processes as the extreme property variations limit the applicability of traditional heat transfer correlations. Transient CFD simulations including the temperature-dependent sulfur properties and geometric complexity of the TES design were used to predict the effect of natural convection during charging and discharging on the heat transfer process, sulfur temperature uniformity, charge/discharge rates, and performance of the storage devices. The CFD model was validated with experimental results for a full charge and discharge cycle. The work will show 3D and 2D simulation comparisons aimed to facilitate rapid design iterations and a machine learning based design optimization approach.

CFD↗

Tech-X contributions to the Center for Tokamak Transients (CTTS) Scientific Discovery through Advanced Computing (SciDAC) project (Final Report)

The Center for Tokamak Transients Simulations (CTTS) consists of computational plasma physicists, computer scientists, and applied mathematicians who are together developing and applying simulation software to improve our understanding of and ability to predict and control transient events in tokamak discharges, particularly those that lead to violent disruptions. We have major simulation activities concerning disruptions that are caused by violating ideal MHD stability criteria, vertical displacement events, resistive wall modes, and tearing modes. We are performing comprehensive modeling of disruption mitigation techniques, particularly by shattered pellet injection (SPI). The Center is built around two mature extended MHD codes: NIMROD and M3D-C1. These codes are being extended in a number of ways as required by the demands of disruption modeling, and are being optimized to work well for larger problem size and modern computer architectures as required to model tokamak plasmas with realistic parameters over the required timescales. The codes will be coupled to the FronTier code for state-of-the-art modeling of SPI. Validation with experimental data on DIII-D, NSTX, and JET is being facilitated by rigorous uncertainty quantification (UQ). The high-level objectives of the center are to: (1) Develop better understanding and improved predictive capability of when crossing a linear stability boundary will likely lead to a disruption, (2) Provide a tool for calculating vessel forces, both axisymmetric and non-axisymmetric, for worst case VDE and other disruptions in tokamaks, (3) Develop increased understanding and improved predictive capability for locked mode disruptions and how best to avoid them, (4) Develop, verify, and validate 3D models for disruption mitigation by shattered pellets that can be used to design and optimize a system for future tokamaks, and (5) Increase the efficiency and scalability of the M3D-C1 and NIMROD codes so that they can model disruptions in ITER scale devices using the most powerful DOE HPC hardware, and (6) Demonstrate code-coupling via FronTier coupling with NIMROD and M3D-C1 and by interfacing these codes within a WDM framework.

97 MATHEMATICS AND COMPUTING↗

Adaptive Protection and Validated Models to Enable Deployment of High Penetrations of Solar PV (PV-MOD)

The availability and validation of various PV models in commercial tools differ, with some models not yet thoroughly validated for advanced inverter functionalities and reliable performance under weak system conditions. Many existing models do not fully incorporate new inverter control functions, which can affect system stability. The increasing deployment of solar PV and other inverter-based resources (IBRs), including distributed energy resources (DERs), is influencing the reliable operation of protection schemes in distribution systems and microgrids. Emerging adaptive protection schemes (APS) offer new opportunities for protecting these systems during varying configurations and DER operating conditions, though their demonstration and validation remain limited. Adaptive protection schemes face similar challenges, as they are typically designed for specific configurations. There is a growing need for tools and methodologies to streamline the deployment of adaptive protection for safe and reliable DER integration. The project main objective was to develop and validate high-fidelity generic models of solar PV facilities for stability, protection, EMT, and QSTS analyses. This objective was achieved, and these models can now be integrated into commercial software tools, enabling utilities, vendors, and developers to study high-penetration PV systems more confidently. The project also demonstrated advanced applications of these models, including the design and deployment of adaptive protection schemes in high-penetration field applications and microgrids, supporting grid safety and reliability. Several milestones were reached by the end of the project. A sophisticated inverter test plan was developed, and inverters representative of the North American marketplace were selected. EPRI and NREL tested various inverters, conforming to IEEE standards. Improvements were made to existing generic models of IBR units, IBR plants, and aggregated feeders for various analyses. The first generic electromagnetic transient (EMT) model for a solar PV plant was developed, conforming to IEEE Std 2800™-2022 and validated against laboratory measurements of a 2.2 MVA large-scale battery energy storage system (BESS) inverter. That model was then used to produce reference responses illustrating examples of validated and verified IBR plant models that pass or fail tests for technical minimum capability and performance as specified in the IEEE standard. The developed, tested, and validated generic models can be used for transmission planning, stability assessments, expansion planning, and evaluating potential future IBR interconnection requirements. They can also support interconnection screens and conformity assessments of IBR plants, including solar PV. The project significantly contributed to the ongoing standardization and model-based representation and verification of IBR responses. The project further addressed challenges of common distribution protection schemes with increasing deployment of DER by developing, validating, and demonstrating adaptive protection schemes (APS) that can improve the reliable and safe integration of DER into distribution systems. New APS were designed using improved DER models for three common distribution systems: a radial feeder, a meshed network, and a microgrid. Modeling and hardware-in-the-loop (HIL) testing of the APS were conducted, successfully showing their effectiveness and selectivity. Proof-of-concept field demonstration was achieved for two APS, i.e., one on a radial feeder and another one in a microgrid. Field demonstration could not be achieved for the APS on a meshed network, primarily due apprehension of one utility partner and also due to limited access to the protective algorithms in the network protectors. Guidelines developed from the lessons learned in the project lay out the general process followed in the design, installation, and commissioning of APS for various distribution systems. Distribution utility partners’ apprehension about field demonstration of the new APS were addressed—with varying success—by taking a stepped risk-management approach of modeling of a wide range of sensitivities first, performing in-depth proof-of-concept testing in the laboratory including HIL next, and finally deliberately implementing and commissioning the actual protection equipment and algorithms into parts of—or in parallel operation to—the three real distribution systems. Future work should include pilot projects that further show the acceptable performance of the developed APS before these schemes be rolled out more widely. Inclusion of both utility and original equipment manufacturers (OEMs) in future projects could increase chances of successful field demonstration. Despite challenges in achieving the field demonstration goal of the project for all three APS, the research significantly contributed to the innovation of adaptive protection solutions for scalable and reliable DER integration into distribution systems. This project significantly enhances the understanding of the impact of using appropriate inverter models on distribution and transmission (T&D) systems. By addressing the limitations of existing generic models, the project introduces high-fidelity models for stability, protection, electromagnetic transient (EMT), and quasi-static time series (QSTS) analyses. These models, integrated into commercial software tools, enable utilities, vendors, and developers to confidently study high-penetration PV systems. The project also demonstrates advanced applications, including adaptive protection schemes (APS) for distribution systems and microgrids, ensuring grid safety and reliability. The technical effectiveness and economic feasibility of the methods are evident through the development and validation of sophisticated inverter test plans and the selection of representative inverters. Testing by EPRI and NREL on retail, commercial, and utility-scale inverters, conforming to IEEE standards, underscores the robustness of the models. Improvements to existing generic models for various analyses further enhance their validity and applicability. The project also identifies gaps in common distribution protection schemes and designed new APS using improved DER models, demonstrating their effectiveness through modeling and hardware-in-the-loop (HIL) testing. The project’s benefits to the public are manifold. By advancing the standardization and model-based representation of IBR response, it supports transmission planning, stability assessments, and future IBR interconnection requirements. The generic models can facilitate better communication between transmission planners and developers, supporting expected IBR plant capability and performance. Additionally, the development of APS for radial feeders, meshed networks, and microgrids supports the integration of distributed energy resources (DERs) into distribution systems, enhancing grid reliability and safety. The project’s emphasis on thorough testing and simplicity in design ensures practical and scalable solutions for DER integration.

14 SOLAR ENERGY↗

Hyper-fidelity depletion coupled with discrete pebble motion in pebble bed reactors

Pebble bed reactors have raised new interest during the past decade due to their attractive characteristics. Therefore, accurate simulations must be performed to better understand these systems and ensure optimal and safe designs. Most current methods use lower fidelity approaches with representative unit-cells or macro-zones with uniform fluxes, which have accuracy and flexibility limitations. A novel hyper-fidelity method for pebble bed reactors depletion is presented and internally couples Serpent 2 and a pseudo-motion routine. Pseudo-motion is applied handling vertical shifts of compositions in a static pebble bed, random reinsertion of used pebbles, insertion of fresh pebbles and used pebbles discarding. Associated with individual depletion to correctly determine the flux spectrum and composition in each pebble, this hyper-fidelity approach paves the way towards more accurate depletion calculation in pebble bed reactors. Using this method, a demonstration is completed on a small-scale reactor. In this application, the core reaches equilibrium, and the following data is extracted: core-wise parameters evolution, pebble-wise spatial and statistical distribution. Discarded pebbles are analyzed, and relevant information is shown. This work proves the feasibility of hyper fidelity depletion with Serpent 2, and the range of use for this method: reactor design and analysis for equilibrium and slow transients, lower fidelity methods validation and feeding fuel performance, thermal-hydraulics, or waste management models. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Control, Fault Management, and Grid Support Functionality of an MV AC-DC Solid State Transformer based EV Extreme Fast Charging Station

Electric vehicles (EVs) have become increasingly popular in recent times while revolutionizing the consumer and commercial transportation market. The development of charging infrastructure has become one of the priorities for increasing the adoption of EVs. Extreme fast charging (XFC) technology can reduce the so-called ’range anxiety’ of consumers as they significantly reduce the charging time. With the advent of wide band-gap (WBG) power devices and improvement in power electronic converters, medium voltage (MV) solid state transformer (SST) based XFC system has the potential to replace the traditional XFC stations because of the lower footprint, ease of installation, enhanced control feature, and better system efficiency. The control system design is one of the critical aspects of the SST development process. Careful consideration and detailed analysis are required to find out suitable control method for the SST based on its topology among different centralized and decentralized control architectures. Also, the control parameters selection and potential improvement to the transient response of the controller ought to be investigated. Another major concern of the SST is different types of internal fault which reduces the overall reliability of the XFC system. As a result, designing a robust protection system is essential. Among different fault modes, open circuit switch faults have received significant attention as an active research area because of their likelihood and severe effects on converters. Therefore, the power stages used in the XFC system require functional and accurate open circuit switch fault management methods. An equally significant aspect of this SST based XFC is its compatibility in a microgrid where there is no synchronous generator present. When the grid is not available, the XFC SSTs can provide grid forming capability and continue supplying the critical loads in islanded mode. The transition between grid connected and islanded mode, especially the grid resynchronization process has to be carefully performed for the safety of the microgrid components. The challenges posed by the aforementioned issues have inspired the work done in this dissertation. Here, a 13.2 kV, 1 MVA, AC/DC SST for the XFC system is examined and a comparative analysis is conducted to select the control architecture based on feasibility of implementation and performance. A detailed control parameter design process is demonstrated considering the sensor dynamics and delay. The selected decentralized control method is augmented by introducing a novel sensor-less load current feedforward method to provide better voltage regulation at the DC bus during a change of load. Next, in the fault management section, a hierarchical failure mode effect analysis (FMEA) is proposed to enable a systematic design of the internal fault protection of the XFC SST as there are limited examples in the literature regarding the analysis of the safety and design of the protection of a power electronic converter system. Novel open circuit switch fault management methods for the converters in the system are presented. Finally, XFC SST based MV microgrid operations in grid connected mode and islanded mode are explored. A secondary control method for grid resynchronization is presented and a design process of control parameters is shown to ensure the stability of the secondary voltage and frequency regulation.

30 DIRECT ENERGY CONVERSION↗

Identifying Potential Sub-Synchronous Oscillations Using Impedance Scan Approach: Preprint

This paper presents an impedance scan study on the real-world power system in Australia that has observed 17 to 20 Hz intermittent subsynchronous oscillations. Through the impedance scan of each of the IBRs, both individually and collectively, potential resonance modes are identified. The impedance scans were carried out using electromagnetic transient PSCAD models of the network. The network comprises of site-specific, black-boxed models of IBRs supplied by the generators. The impedance scan approach was divided in three major steps: (1) the first step is to identify IBRs where impedance analysis needs to be performed based on the magnitude of oscillations observed at their points of interconnection (POIs); (2) the second step focuses on performing impedance scans at selected IBRs in single-machine infinite-bus (SMIB) configuration to identify internal resonance modes of an IBR and to evaluate if any of these modes become unstable under certain grid conditions; (3) the third step performs impedance scans at a few selected IBRs while connected to the wider network model to obtain the impedance response of both the IBR and the grid - this step evaluates control interactions among IBRs. The impedance scan study found that a few IBRs have an underdamped resonance mode at around 17 Hz, which becomes unstable under a certain operating condition. Another interesting finding was that certain IBRs increase the effective grid impedance seen by another IBR in proximity for a particular operating condition. Under this operating condition, the resulting subsynchronous oscillation mode is more pronounced due to a combination of control interactions among IBRs through the transmission network under study and a resonance mode inside the IBRs.

control interactions↗

ARC physics basis–magnetohydrodynamics

ARC is designed to produce 400 ⁢MW of net electricity and prove the commercial feasibility of a fusion power plant. In order to achieve this goal ARC has to operate with optimal core performance in a stationary scenario that minimises wear on the first wall and divertor. This requires avoiding or mitigating magnetohydrodynamic (MHD) instabilities which have the potential to not only degrade the plasma core but also lead to deleterious transient heat loads on plasma facing components. Therefore, this work aims at characterising the MHD stability of the high performance ARC scenario and inform the design of error field correction coils. Firstly, simulations of vertical displacement events show that an in-vessel coil is not needed and instead the poloidal shaping coils can be used to control vertical stability. These simulations also inform the demands on the corresponding coil power supplies. Stability analysis of the ideal kink mode with or without a conducting wall and kinetic effects suggests that the ARC baseline scenario operates deeply in the stable region. Using RDCON, tearing modes at the 𝑚/𝑛 =2/1 and 3/2 surfaces (with poloidal mode number 𝑚, and toroidal mode number 𝑛) are shown to be linearly stable, and including thermal transport effects in the rational surfaces lead to further stabilisation. However, other transient plasma instabilities can seed neoclassical tearing modes (NTMs). The marginally stable width of NTMs in ARC strongly depends on the internal inductance and can fall below 0.1% of the normalised poloidal flux. Furthermore, an empirical cross-machine model of the 𝑛 =1 error field leading to a disruption predicts a critical error field larger than SPARC but smaller than ITER. Three-dimensional coils can be designed with the Generalised Purturbed Equilbium Code based on a simple model that calculates the maximum correctable error field that is limited by the neoclassical toroidal viscosity torque. Broad scans of different coil geometries identify a set of 2 rows of off-midplane coils to be a suitable solution. It is also determined that such a set of three-dimensional coils is capable of correcting 𝑛 =2 error fields to some degree and creating strong enough 𝑛 =2 or 𝑛 =3 edge resonant perturbation fields for the suppression of edge-localised modes at reasonable coil currents. The final design of the first ARC will be further informed by results from SPARC.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Physics-Based Methods of Failure Analysis and Diagnostics in Human Space Flight

The Integrated Health Management (IHM) for the future aerospace systems requires to interface models of multiple subsystems in an efficient and accurate information environment at the earlier stages of system design. The complexity of modern aeronautic and aircraft systems (including e.g. the power distribution, flight control, solid and liquid motors) dictates employment of hybrid models and high-level reasoners for analysing mixed continuous and discrete information flow involving multiple modes of operation in uncertain environments, unknown state variables, heterogeneous software and hardware components. To provide the information link between key design/performance parameters and high-level reasoners we rely on development of multi-physics performance models, distributed sensors networks, and fault diagnostic and prognostic (FD&P) technologies in close collaboration with system designers. The main challenges of our research are related to the in-flight assessment of the structural stability, engine performance, and trajectory control. The main goal is to develop an intelligent IHM that not only enhances components and system reliability, but also provides a post-flight feedback helping to optimize design of the next generation of aerospace systems. Our efforts are concentrated on several directions of the research. One of the key components of our strategy is an innovative approach to the diagnostics/prognostics based on the real time dynamical inference (DI) technologies extended to encompass hybrid systems with hidden state trajectories. The major investments are into the multiphysics performance modelling that provides an access of the FD&P technologies to the main performance parameters of e.g. solid and liquid rocket motors and composite materials of the nozzle and case. Some of the recent results of our research are discussed in this chapter. We begin by introducing the problem of dynamical inference of stochastic nonlinear models and reviewing earlier results. Next, we present our analytical approach to the solution of this problem based on the path integral formulation. The resulting algorithm does not require an extensive global search for the model parameters, provides optimal compensation for the effects of dynamical noise, and is robust for a broad range of dynamical models. In the following Section the strengths of the algorithm are illustrated illustrated by inferring the parameters of the stochastic Lorenz system and comparing the results with those of earlier research. Next, we discuss a number of recent results in application to the development of the IHM for aerospace system. Firstly, we apply dynamical inference approach to a solution of classical three tank problems with mixed unknown continuous and binary parameters. The problem is considered in the context of ground support system for filling fuel tanks of liquid rocket motors. It is shown that the DI algorithm is well suited for successful solution of a hybrid version of this benchmark problem even in the presence of additional periodic and stochastic perturbation of unknown strength. Secondly, we illustrate our approach by its application to an analysis of the nozzle fault in a solid rocket motor (SRM). The internal ballistics of the SRM is modelled as a set of one-dimensional partial differential equations coupled to the dynamics of the propellant regression. In this example we are specifically focussed on the inference of discrete and continuous parameters of the nozzle blocking fault and on the possibility of an application of the DI algorithm to reducing the probability of "misses" of an on-board FD&P for SRM. In the next section re-contact problem caused by first stage/upper stage separation failure is discussed. The reaction forces imposed on the nozzle of the upper stage during the re-contact and their connection to the nozzle damage and to the thrust vector control (TVC) signal are obtained. It is shown that transient impact induced torquean be modelled as a response of an effective damped oscillator. A possible application of the DI algorithm to the inference of damage parameters and predicting fault dynamics ahead of time using the actuator signal is discussed. Finally, we formulate Bayesian inferential framework for development of the IHM system for in-flight structural health monitoring (SHM) of composite materials. We consider the signal generated by piezoelectric actuator mounted on composite structure generating elastic waves in it. The signal received by the sensor is than compared with the baseline signal. The possibility of damage inference is discussed in the context of development of the SHM.

Smelyanskiy, Vadim N.↗