Search NASA⌕ Search

SEARCH · Search NASA

Results for “Proton imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

The Sodium Tail of the Moon

During the few days centered about new Moon, the lunar surface is optically hidden from Earth-based observers. However, the Moon still offers an observable: an extended sodium tail. The lunar sodium tail is the escaping "hot" component of a coma-like exosphere of sodium generated by photon-stimulated desorption, solar wind sputtering and meteoroid impact. Neutral sodium atoms escaping lunar gravity experience solar radiation pressure that drives them into the anti-solar direction forming a comet-like tail. During new Moon time, the geometry of the Sun, Moon and Earth is such that the anti-sunward sodium flux is perturbed by the terrestrial gravitational field resulting in its focusing into a dense core that extends beyond the Earth. An all-sky camera situated at the El Leoncito Observatory (CASLEO) in Argentina has been successfully imaging this tail through a sodium filter at each lunation since April 2006. This paper reports on the results of the brightness of the lunar sodium tail spanning 31 lunations between April 2006 and September 2008. Brightness variability trends are compared with both sporadic and shower meteor activity, solar wind proton energy flux and solar near ultra violet (NUV) patterns for possible correlations. Results suggest minimal variability in the brightness of the observed lunar sodium tail, generally uncorrelated with any single source, yet consistent with a multi-year period of minimal solar activity and non-intense meteoric fluxes.

Matta, M.↗

Production of Radioisotopes of Scandium for Imaging and Therapy (Final Report)

The theranostic approach is a powerful technique that enables scientists and physicians to diagnose and treat diseases using the same targeting moiety labeled with radionuclides for imaging and therapy. A challenge behind synthesizing and evaluating these theranostic radiopharmaceuticals lies in the production of suitable radionuclides. This study aimed to investigate the production of high radionuclidic purity 43 Sc from enriched [ 46 Ti]TiO 2 for Positron Emission Tomography (PET) and 47 Sc from enriched [ 50 Ti]TiO 2 for targeted radiotherapy, as well as establish a target recycling technique for continued production of these radionuclides. Methods: Targets were prepared with 100 mg of either enriched [ 46 Ti]TiO 2 or [ 50 Ti]TiO 2 , pressed into pellets, and placed into Ta target holders with a 0.127 mm natTi cover foil. The 46 Ti targets were bombarded with 18 MeV protons at 20 µA for 1.5 h, while 50Ti targets were bombarded with 24 MeV protons at 20 µA for 4 or 8 h. The radioscandium nuclides were purified using branched N, N, N’, N’ -tetra-2-ethylhexyldiglycolamide (DGA) resin. The titanium targets were recycled by precipitating the dissolved Ti collected from the column effluent and wash streams, pH adjustment, vacuum filtration, and then drying the solid at 250 °C prior to reforming the target for the subsequent bombardment. The apparent molar activity of the isolated radioscandiums was analyzed by titration with 1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid (DOTA). The relative imaging performance of 18 F, 43 Sc, and 68 Ga were analyzed with PET images acquired with 30-min static scans. Results: The average radioscandium recovery for 43Sc was 91.7 ± 7.4 %, with a radionuclidic purity of 98.8 %. The average recovery of 47Sc was 89.9 ± 3.9 %, with a radionuclidic purity of 90.8%. The average recovery of enriched TiO2 was 96 ± 4.0 %. The highest apparent molar activity for [43Sc]Sc-DOTA was 23.2 GBq/µmol and 3.39 GBq/µmol for [ 47 Sc]Sc-DOTA. The order of PET resolution from highest to lowest was 18 F > 43 Sc > 68 Ga. Conclusions: This work demonstrates the feasibility of using enriched recycled [ 46 Ti]TiO 2 and [ 50 Ti]TiO 2 targets for the production of the 43 Sc and 47 Sc theranostic isotope pair in high purity.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Atomic dynamics of gas-dependent oxide reducibility

Understanding oxide reduction is critical for advancing metal production, catalysis and energy technologies. Although carbon monoxide (CO) and hydrogen (H 2 ) are widely used reductants, the mechanisms by which they work are often presumed to be similar, both involving lattice oxygen removal. However, because of growing interest in replacing CO with H 2 to lower CO 2 emissions, distinguishing gas-specific reduction pathways is critical. Yet, capturing these atomic-scale processes under reactive gas and high-temperature conditions remains challenging. Here we use environmental transmission electron microscopy, which is capable of real-time, atomic-resolution imaging of gas–solid redox reactions to directly visualize the gas-dependent oxide reduction dynamics in NiO. We show that CO drives surface nucleation and the growth of metallic Ni islands, leading to self-limiting surface metallization. Conversely, H 2 activates a coupled surface-to-bulk transformation, where protons from dissociated H 2 infiltrate the oxide lattice to promote the inward migration of surface-generated oxygen vacancies and enabling bulk metallization. By contrast, oxygen vacancies formed by CO remain confined near the surface, where they rapidly form a metallic Ni layer that inhibits further reduction. Furthermore, these results reveal distinct atomistic pathways for CO and H 2 and provide insights that may guide metallurgical processes and catalyst design.

36 MATERIALS SCIENCE↗

GEOTAIL and POLAR Observations of Auroral Kilometric Radiation and Terrestrial Low Frequency Bursts and their Relationship to Energetic Particles, Auroras, and Other Substorm Phenomena

Terrestrial low frequency (LF) bursts are plasma wave phenomena that appear to be a part of the low frequency end of the auroral kilometric radiation (AKR) spectrum and are observed during strong substorms, GEOTAIL and POLAR plasma wave observations from within the magnetosphere show that the AKR increases in intensity and its lower frequency limits decrease when LF bursts are observed. The first is expected as it is shows substorm onset and the latter indicates that the AKR source region is expanding to higher altitudes. Images from the POLAR VIS Earth Camera operating in the far-UV range and the POLAR UVI experiment usually feature an auroral brightening and an expansion of the aurora to higher latitudes at the time of the LF bursts. Enhanced fluxes of X-rays from precipitating electrons have also been observed by POLAR PIXIE. High resolution ground Abstract: magnetometer data from the CANOPUS and IMAGE networks show that the LF bursts occur when the expansive phase onset signatures are most intense. The ground magnetometer data and the CANOPUS meridian scanning photometer data sometimes show that during the LF burst events the expansive phase onset starts at unusually low latitudes and moves poleward. Large injections of energetic protons and electrons have also been detected by the GOES and LANL geosynchronous satellites during LF burst events. While most of the auroral brightenings and energetic particle injections associated with the LF bursts occur near local midnight, several have been observed as early as mid-afternoon. From these various measurements, we are achieving a better understanding of the plasma and particle motions during substorms that are associated with the generation and propagation of terrestrial LF bursts

Anderson, R . R.↗

Neutron Imaging Camera

The Neutron Imaging Camera (NIC) is based on the Three-dimensional Track Imager (3DTI) technology developed at GSFC for gamma-ray astrophysics applications. The 3-DTI, a large volume time-projection chamber, provides accurate, approximately 0.4 mm resolution, 3-D tracking of charged particles. The incident direction of fast neutrons, En > 0.5 MeV, are reconstructed from the momenta and energies of the proton and triton fragments resulting from (sup 3)He(n,p) (sup 3)H interactions in the 3-DTI volume. The performance of the NIC from laboratory and accelerator tests is presented.

Hunter, Stanley↗

Measurement of deeply virtual Compton scattering off 4 He with the CEBAF Large Acceptance Spectrometer at Jefferson Lab

We report on the measurement of the beam spin asymmetry in the deeply virtual Compton scattering off $^4$He using the CEBAF Large Acceptance Spectrometer (CLAS) at Jefferson Lab using a 6 GeV longitudinally polarized electron beam incident on a pressurized $^4$He gaseous target. We detail the method used to ensure the exclusivity of the measured reactions, in particular the upgrade of CLAS with a radial time projection chamber to detect the low-energy recoiling $^4$He nuclei and an inner calorimeter to extend the photon detection acceptance at forward angles. Our results confirm the theoretically predicted enhancement of the coherent ($e^4$He$~\to~e'$$^4$He$'\gamma'$) beam spin asymmetries compared to those observed on the free proton, while the incoherent ($e^4$He$~\to~e'$p$'\gamma'$X$'$) asymmetries exhibit a 30$\%$ suppression. From the coherent data, we were able to extract, in a model-independent way, the real and imaginary parts of the only $^4$He Compton form factor, $\cal H_A$, leading the way toward 3D imaging of the partonic structure of nuclei.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Design, characterization, and intracellular trafficking of biofunctionalized chitosan nanomicelles

The hydrophobically modified glycol chitosan (HGC) nanomicelle has received increasing attention as a promising platform for the delivery of chemotherapeutic drugs. To improve the tumor selectivity of HGC, here an avidin and biotin functionalization strategy was applied. The hydrodynamic diameter of the biotin-avidin-functionalized HGC (cy5.5-HGC-B4F) was observed to be 104.7 nm, and the surface charge was +3.1 mV. Confocal and structured illumination microscopy showed that at 0.1 mg/ml, cy5.5-HGC-B4F nanomicelles were distributed throughout the cytoplasm of MDA-MB-231 breast cancer cells after 2 h of exposure without significant cytotoxicity. To better understand the intracellular fate of the nanomicelles, entrapment studies were performed and demonstrated that some cy5.5-HGC-B4F nanomicelles were capable of escaping endocytic vesicles, likely via the proton sponge effect. Quantitative analysis of the movements of endosomes in living cells revealed that the addition of HGC greatly enhanced the motility of endosomal compartments, and the nanomicelles were transported by early and late endosomes from cell periphery to the perinuclear region. Our results validate the importance of using live-cell imaging to quantitatively assess the dynamics and mechanisms underlying the complex endocytic pathways of nanosized drug carriers.

Li, Weiyi↗

NUMI Flux Systematic Uncertainties

The Imaging Cosmic And Rare Underground Signals (ICARUS) detector is a 476 t active liquid argon time projection chamber neutrino detector at Fermilab. ICARUS lies 795 m downstream and 5.75◦ off-axis from the Neutrinos at the Main Injector (NuMI) beam. To create a neutrino beam NuMI directs pulsed beam of 120 GeV protons onto a graphite target to create hadrons, which are then focused by magnetic horns and allowed to decay into neutrinos. At the ICARUS off-axis angle the neutrino flux originates from the decays of unfocused/antifocused pions decays and from high-transverse momentum kaon decays. These contributions allow ICARUS to observe a significant flux of (anti-)electron and (anti-)muon neutrinos in a kinematic region relevant to the upcoming DUNE experiment. These factors also introduce various model uncertainties that have not been studied in detail by existing on-axis experiments. This poster will explore the systematic uncertainties in the NuMI flux at ICARUS that arise from uncertainties on hadron interaction cross sections and beamline operation conditions.

Alrahman, Fatima Abd [Houston U.]↗

Constraints on Cosmic Rays, Magnetic Fields, and Dark Matter from Gamma-ray Observations of the Coma Cluster of Galaxies with VERITAS and FERMI

Observations of radio halos and relics in galaxy clusters indicate efficient electron acceleration. Protons should likewise be accelerated and, on account of weak energy losses, can accumulate, suggesting that clusters may also be sources of very high energy (VHE; E greater than100 GeV) gamma-ray emission. We report here on VHE gamma-ray observations of the Coma galaxy cluster with the VERITAS array of imaging Cerenkov telescopes, with complementing Fermi Large Area Telescope observations at GeV energies. No significant gamma-ray emission from the Coma Cluster was detected. Integral flux upper limits at the 99 confidence level were measured to be on the order of (2-5) x 10(sup -8) photons m(sup -2) s(sup -1) (VERITAS,greater than 220 GeV) and approximately 2 x 10(sup -6) photons m(sup -2) s(sup -1) (Fermi, 1-3 GeV), respectively. We use the gamma-ray upper limits to constrain cosmic rays (CRs) and magnetic fields in Coma. Using an analytical approach, the CR-to-thermal pressure ratio is constrained to be less than 16% from VERITAS data and less than 1.7% from Fermi data (averaged within the virial radius). These upper limits are starting to constrain the CR physics in self-consistent cosmological cluster simulations and cap the maximum CR acceleration efficiency at structure formation shocks to be 50. Alternatively, this may argue for non-negligible CR transport processes such as CR streaming and diffusion into the outer cluster regions. Assuming that the radio-emitting electrons of the Coma halo result from hadronic CR interactions, the observations imply a lower limit on the central magnetic field in Coma of approximately (2-5.5)microG, depending on the radial magnetic field profile and on the gamma-ray spectral index. Since these values are below those inferred by Faraday rotation measurements in Coma (for most of the parameter space), this renders the hadronic model a very plausible explanation of the Coma radio halo. Finally, since galaxy clusters are dark matter (DM) dominated, the VERITAS upper limits have been used to place constraints on the thermally averaged product of the total self-annihilation cross section and the relative velocity of the DM particles, (sigma upsilon)

cosmic↗

Production and purification of 43Sc and 47Sc from enriched [46Ti]TiO2 and [50Ti]TiO2 targets

Abstract The radioscandium isotopes, 43 Sc and 47 Sc, compose a promising elementally matched theranostic pair that can be used for the development of imaging and therapeutic radiopharmaceuticals with identical structures. This study aimed to investigate the production of high radionuclidic purity 43 Sc from enriched [ 46 Ti]TiO 2 targets and 47 Sc from enriched [ 50 Ti]TiO 2 targets and establish a target recycling technique. Enriched [ 46 Ti]TiO 2 targets were irradiated with 18 MeV protons, and enriched [ 50 Ti]TiO 2 targets were bombarded with 24 MeV protons. 43 Sc and 47 Sc were purified using ion chromatography attaining recovery yields of 91.7 ± 7.4% and 89.9 ± 3.9%, respectively. The average radionuclidic purity for 43 Sc was 98.8 ± 0.3% and for 47 Sc 91.5 ± 0.6%, while the average recovery of enriched titanium target material was 96 ± 4.0%. The highest apparent molar activity for [ 43 Sc]Sc-DOTA was 23.2 GBq/µmol and 3.39 GBq/µmol for [ 47 Sc]Sc-DOTA. This work demonstrates the feasibility of using enriched recycled [ 46 Ti]TiO 2 and [ 50 Ti]TiO 2 targets to produce high purity 43 Sc and 47 Sc as an elementally matched theranostic isotope pair.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Single Molecule Spectroscopy Studies of Acid–Base Chemical Gradients Using Nile Red as a Probe of Local Surface Acidity

Single molecule spectroscopy studies of local acidity along bifunctional acid-base gradients are reported. Gradients are prepared by directional vapor phase diffusion and subsequent reaction of 3-aminopropyl-trimethoxysilane with a uniform silica film. Gradient formation is confirmed by spectroscopic ellipsometry and by static water contact angle measurements. X-ray photoelectron spectroscopy is used to characterize the nitrogen content and degree of nitrogen protonation along the gradient. Nile Red is employed as the probe dye in single molecule spectroscopy studies of these gradients. While Nile Red is well-known for its solvent sensitivity, it is used here, for the first time, to sense the acid/base properties of the film in two-color wide-field fluorescence imaging experiments. The data reveal broad bimodal distributions of Nile Red emission spectra that vary along the gradient direction. The single-molecule results are consistent with solution-phase ensemble acid/base studies of the dye. The former reveal a gradual transition from a surface dominated by basic aminosilane sites at the high-amine end of the gradient to one dominated by acidic silanol sites at the low-amine end. The sub-diffraction-limited spatial resolution afforded by superlocalization of the single molecules reveals spatial correlations in the acid/base properties of the gradient over ~ 200 nm distances. Furthermore, these studies provide data relevant to the use of aminosilane-modified silica in bifunctional, cooperative chemical catalysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Neutron Imaging Camera

We describe the Neutron Imaging Camera (NIC) being developed for DTRA applications by NASA/GSFC and NSWC/Carderock. The NIC is based on the Three-dimensional Track Imager (3-DTI) technology developed at GSFC for gamma-ray astrophysics applications. The 3-DTI, a large volume time-projection chamber, provides accurate, approximately 0.4 mm resolution. 3-D tracking of charged particles. The incident direction of fast neutrons, E(sub N) > 0.5 MeV. arc reconstructed from the momenta and energies of the proton and triton fragments resulting from 3He(n,p)3H interactions in the 3-DTI volume. We present angular and energy resolution performance of the NIC derived from accelerator tests.

Hunter, Stanley D.↗

First Search for Dark-Trident Processes Using the MicroBooNE Detector

This thesis presents a first search for dark-trident scattering in a neutrino beam using a data set corresponding to $7.2 \times 10^{20}$ protons on target taken with the MicroBooNE detector at Fermilab. Proton interactions in the neutrino target at the Main Injector produce $\pi^0$ and $\eta$ mesons, which could decay into dark matter (DM) particles via a dark photon $A^{\prime}$. A convolutional neural network is trained to identify interactions of the DM particles in the liquid-argon time projection chamber (LArTPC) exploiting its image-like reconstruction capability. In the absence of a DM signal, limits at the $90\%$ confidence level on the squared kinematic mixing parameter $\varepsilon^2$ as a function of the dark-photon mass in the range $10\le M_{A^\prime}\le 400$~MeV are provided. The limits cover previously unconstrained parameter space for the production of fermion or scalar DM particles $\chi$ for two benchmark models with mass ratios $M_{\chi}/M_{A^\prime}=0.6$ and $2$ and for dark fine-structure constants $0.1\le\alpha_D\le 1$.Date of Award1 Aug 2024Original languageEnglishAwarding InstitutionThe University of ManchesterSupervisorStefan Soldner-Rembold (Supervisor) & Justin Evans (Supervisor)

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Dosimetry of heavy ions by use of CCD detectors

The design and the atomic composition of Charge Coupled Devices (CCD's) make them unique for investigations of single energetic particle events. As detector system for ionizing particles they detect single particles with local resolution and near real time particle tracking. In combination with its properties as optical sensor, particle transversals of single particles are to be correlated to any objects attached to the light sensitive surface of the sensor by simple imaging of their shadow and subsequent image analysis of both, optical image and particle effects, observed in affected pixels. With biological objects it is possible for the first time to investigate effects of single heavy ions in tissue or extinguished organs of metabolizing (i.e. moving) systems with a local resolution better than 15 microns. Calibration data for particle detection in CCD's are presented for low energetic protons and heavy ions.

Schott, J. U.↗

Radiation sensitivity of silicon imaging sensors on missions to the outer planets.

Review of the results of an investigation of the magnitude of the degradation effects of radiation on the operating characteristics of camera tubes using silicon diode arrays in the space environment, and discussion of the radiation damage mechanisms concerned. The effects produced by bombardment of bare-silicon-diode arrays or vidicon tubes with 85-kV X rays, Cobalt 60 gamma rays, 1 MeV and 11 MeV electrons, 3 MeV and 142 MeV protons, and reactor neutrons are presented. Interference effects produced by radiation bombardment during operation of television tubes are investigated, and limiting fluxes of electrons and protons are given.

Brucker, G. J.↗

Regulation of Absorption and Emission in a Protein/Fluorophore Complex

Human cellular retinol binding protein II (hCRBPII) was used as a protein engineering platform to rationally regulate absorptive and emissive properties of a covalently bound fluorogenic dye. We demonstrate the binding of a thio-dapoxyl analog via formation of a protonated imine between an active site lysine residue and the chromophore’s aldehyde. Rational manipulation of the electrostatics of the binding pocket results in a 204 nm shift in absorption and a 131 nm shift in emission. The protein is readily expressed in mammalian systems and binds with exogenously delivered fluorophore as demonstrated by live-cell imaging experiments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Surface-Induced Deprotonation of Thiol Ligands Impacts the Optical Response of CdS Quantum Dots

Cadmium chalcogenide quantum dots (QDs) passivated by thiol-based ligands exhibit several advantages in their applications in lighting, sensing, and imaging technologies. However, their emission is sensitive to thiol concentrations, pH conditions, and temperatures. Using calculations based on the density functional theory, we identify conditions for thiol/thiolate equilibrium at the CdS QD surface that either eliminate or introduce optically inactive hole trap states favoring or disfavoring the emission. Our calculations indicate much weaker interactions between the QD and protonated species (thiols), compared to their deprotonated counterparts (thiolates). Additionally, the surface of CdS QD facilitates the partial deprotonation of thiols, leading to the formation of an additional stable networking conformation where the proton is shared between the ligand and the QD surface. Thiolates strongly reduce the optical intensity of low-energy transitions in CdS QDs, contributing thiolate-localized hole trap states at the QD band gap. However, networking between the thiols and the surface, as well as the presence of native ligands such as primary amines, stabilize such trap states brightening the lowest optical transitions. This explains the increased emission of thiol-passivated QDs at lower concentrations in neutral or acidic solutions. Surface-mediated bias toward deprotonated species and their contribution to optically inactive states also rationalizes irreversible emission quenching and bleaching in the CdSe/CdS QDs exposed to high temperatures or intensive laser pulse.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A comparison of quality factors and weighting factors for characterizing astronaut radiation exposures

Radiation exposures are typically characterized by two quantities. The first is the absorbed dose, or the energy deposited per unit mass for specific types of radiation passing through specified materials. The same amount of energy deposited in material by two different types of radiation, however, can result in two different levels of risk. Because of this, for the purpose of radiation protection operations, absorbed dose is modified by a second factor intended to normalize the risk associated with a given exposure. We present here an inter-comparison of methods for this modification. First is the radiation quality factor (Q), as defined by ICRP publication 60. This quantity is related functionally to the unrestricted linear energy transfer (LET) of a given radiation, and is multiplied by the absorbed dose to derive the dose equivalent (H). The second method for modifying absorbed dose is the radiation weighting factor, also given in ICRP-60, or as modified in NCRP report 115. To implement the weighting factor, the absorbed dose resulting from incidence of a particular radiation is multiplied by a factor assigned to that type of radiation, giving the equivalent dose. We compare calculations done based on identical fields of radiation representative of that encountered by the MIR space station, applying each of these two methods. c2002 COSPAR. Published by Elsevier Science Ltd. All rights reserved.

NASA Center JSC↗