Search NASA⌕ Search

SEARCH · Search NASA

Results for “QUALITY FACTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

All-Ceramic Passive Wireless Temperature Sensor Realized by Tin-Doped Indium Oxide (ITO) Electrodes for Harsh Environment Applications

In this work, an all-ceramic passive wireless inductor–capacitor (LC) resonator was presented for stable temperature sensing up to 1200 °C in air. Instead of using conventional metallic electrodes, the LC resonators are modeled and fabricated with thermally stable and highly electroconductive ceramic oxide. The LC resonator was modeled in ANSYS HFSS to operate in a low-frequency region (50 MHz) within 50 × 50 mm geometry using the actual material properties of the circuit elements. The LC resonator was composed of a parallel plate capacitor coupled with a planar inductor deposited on an Al2O3 substrate using screen-printing, and the ceramic pattern was sintered at 1250 °C for 4 h in an ambient atmosphere. The sensitivity (average change in resonant frequency with respect to temperature) from 200–1200 °C was ~170 kHz/°C. The temperature-dependent electrical conductivity of the tin-doped indium oxide (ITO, 10% SnO2 doping) on the quality factor showed an increase of Qf from 36 to 43 between 200 °C and 1200 °C. The proposed ITO electrodes displayed improved sensitivity and quality factor at elevated temperatures, proving them to be an excellent candidate for temperature sensing in harsh environments. The microstructural analysis of the co-sintered LC resonator was performed using a scanning electron microscope (SEM) which showed that there are no cross-sectional and topographical defects after several thermal treatments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparisons of Integrated Radiation Transport Models with Microdosimetry Data in Spaceflight

Astronauts are exposed to galactic cosmic rays (GCR), trapped protons, and possible solar particle events (SPE) during spaceflight. For such complicated mixtures of radiation types and kinetic energies, tissue equivalent proportional counters (TEPC's) represent a simple time-dependent approach for radiation monitoring. Of interest in radiation protection is the average quality factor of a radiation field defined as a function of linear energy transfer, LET, Q(sub ave)(LET). However TEPC's measure the average quality factors as a function of lineal energy (y), Q(sub ave)(y) defined as the average energy deposition in a volume divided by the average chord length of the volume. Lineal energy, y deviates from LET due to energy straggling, delta-ray escape or entry, and nuclear fragments produced in the detector. Using integrated space radiation models that includes the transport code HZETRN/BRYNTRN, the quantum nuclear interaction model, QMSFRG, and results from Monte-Carlo track simulations of TEPC's response to ions, we consider comparisons of model calculations to TEPC results from NASA missions in low Earth orbit and make predictions for lunar and Mars missions. Good agreement between the model and measured spectra from past NASA missions is found. A finding of this work is that TEPC's values for trapped or solar protons of Q(sub ave)(y) range from 1.9-2.5, overestimating Q(sub ave)(LET), which ranges from 1.4-1.6 with both quantities increasing with shielding depth due to nuclear secondaries Comparisons for the complete GCR spectra show that Q(sub ave)(LET) for GCR is approximately 3.5-4.5, while TEPC's measure 2.9-3.4 for Q(sub ave)(y) with the GCR values decreasing with depth as heavy ions are absorbed in shielding material. Our results support the use of TEPC's for space radiation environmental monitoring when computational analysis is used for proper data interpretation.

Cucinotta, Francis A.↗

On the nature of two-photon transitions for a collection of molecules in a Fabry–Perot cavity

Here, we investigate the effect of a cavity on nonlinear two-photon transitions of a molecular system and we analyze how such an effect depends on the cavity quality factor, the field enhancement, and the possibility of dephasing. We find that the molecular response to strong light fields in a cavity with a variable quality factor can be understood as arising from a balance between (i) the ability of the cavity to enhance the field of an external probe and promote multiphoton transitions more easily and (ii) the fact that the strict selection rules on multiphoton transitions in a cavity support only one resonant frequency within the excitation range. Although our simulations use a classical level description of the radiation field (i.e., we solve Maxwell–Bloch or Maxwell–Liouville equations within the Ehrenfest approximation for the field–molecule interaction), based on experience with this level of approximation in the past studies of plasmonic and polaritonic systems, we believe that our results are valid over a wide range of external probing.

74 ATOMIC AND MOLECULAR PHYSICS↗

Axion Dark Matter EXperiment 2A Cavity Characterization

The axion is a highly motivated dark matter candidate for its capacity to solve the strong CP problem in quantum chromodynamics. To detect the axion, the 2A phase of the Axion Dark Matter EXperiment (ADMX) utilizes four identical cylindrical resonant cavities that can detect the photons converted from axions in a strong magnetic field. We found the quality factors for various tunings in cavity D, and we also learned that the piezo motors are not currently equipped to handle cryogenic temperatures. However, the measured quality factors are much more promising than those shown in the last 2A cooldown, improving by about a factor of five.

Maglione, Diego↗

Effect of chemical and heat treatment on the superconducting properties of niobium used in superconducting radiofrequency cavity fabrication

Niobium is the material of choice for the fabrication of the superconducting radiofrequency (SRF) cavities used in particle accelerator. In the last four decades, much work has been done to push the performance of SRF cavity to its theoretical limits of the accelerating gradient and high quality factor. One of the issues towards achieving those limits is the high residual loss and occurrence of a sharp increase of the RF losses (decrease in quality factor) when the peak magnetic field reaches about 100 mT, consequently limiting the operational accelerating gradient of SRF cavities. We present the result on the effect of the surface and heat treatment on ac and dc superconducting properties to explore the limiting factors of the SRF cavity performance.

Dhakal, Pashupati↗

NASA Models of Space Radiation Induced Cancer, Circulatory Disease, and Central Nervous System Effects

The risks of late effects from galactic cosmic rays (GCR) and solar particle events (SPE) are potentially a limitation to long-term space travel. The late effects of highest concern have significant lethality including cancer, effects to the central nervous system (CNS), and circulatory diseases (CD). For cancer and CD the use of age and gender specific models with uncertainty assessments based on human epidemiology data for low LET radiation combined with relative biological effectiveness factors (RBEs) and dose- and dose-rate reduction effectiveness factors (DDREF) to extrapolate these results to space radiation exposures is considered the current "state-of-the-art". The revised NASA Space Risk Model (NSRM-2014) is based on recent radio-epidemiology data for cancer and CD, however a key feature of the NSRM-2014 is the formulation of particle fluence and track structure based radiation quality factors for solid cancer and leukemia risk estimates, which are distinct from the ICRP quality factors, and shown to lead to smaller uncertainties in risk estimates. Many persons exposed to radiation on earth as well as astronauts are life-time never-smokers, which is estimated to significantly modify radiation cancer and CD risk estimates. A key feature of the NASA radiation protection model is the classification of radiation workers by smoking history in setting dose limits. Possible qualitative differences between GCR and low LET radiation increase uncertainties and are not included in previous risk estimates. Two important qualitative differences are emerging from research studies. The first is the increased lethality of tumors observed in animal models compared to low LET radiation or background tumors. The second are Non- Targeted Effects (NTE), which include bystander effects and genomic instability, which has been observed in cell and animal models of cancer risks. NTE's could lead to significant changes in RBE and DDREF estimates for GCR particles, and the potential effectiveness of radiation mitigator's. The NSRM- 2014 approaches to model radiation quality dependent lethality and NTE's will be described. CNS effects include both early changes that may occur during long space missions and late effects such as Alzheimer's disease (AD). AD effects 50% of the population above age 80-yr, is a degenerative disease that worsens with time after initial onset leading to death, and has no known cure. AD is difficult to detect at early stages and the small number of low LET epidemiology studies undertaken have not identified an association with low dose radiation. However experimental studies in mice suggest GCR may lead to early onset AD. We discuss modeling approaches to consider mechanisms whereby radiation would lead to earlier onset of occurrence of AD. Biomarkers of AD include amyloid beta (A(Beta)) plaques, and neurofibrillary tangles (NFT) made up of aggregates of the hyperphosphorylated form of the micro-tubule associated, tau protein. Related markers include synaptic degeneration, dentritic spine loss, and neuronal cell loss through apoptosis. Radiation may affect these processes by causing oxidative stress, aberrant signaling following DNA damage, and chronic neuroinflammation. Cell types to be considered in multi-scale models are neurons, astrocytes, and microglia. We developed biochemical and cell kinetics models of DNA damage signaling related to glycogen synthase kinase-3(Beta) (GSK3(Beta)) and neuroinflammation, and considered multi-scale modeling approaches to develop computer simulations of cell interactions and their relationships to A(Beta) plaques and NFTs. Comparison of model results to experimental data for the age specific development of A(Beta) plaques in transgenic mice will be discussed.

Cucinotta, Francis A.↗

Application of real-time radiation dosimetry using a new silicon LET sensor

A new type of real-time radiation monitoring device, RRMD-III, consisting of three double-sided silicon strip detectors (DSSDs), has been developed and tested on-board the Space Shuttle mission STS-84. The test succeeded in measuring the linear energy transfer (LET) distribution over the range of 0.2 keV/micrometer to 600 keV/micrometer for 178 h. The Shuttle cruised at an altitude of 300 to 400 km and an inclination angle of 51.6 degrees for 221.3 h, which is equivalent to the International Space Station orbit. The LET distribution obtained for particles was investigated by separating it into galactic cosmic ray (GCR) particles and trapped particles in the South Atlantic Anomaly (SAA) region. The result shows that the contribution in dose-equivalent due to GCR particles is almost equal to that from trapped particles. The total absorbed dose rate during the mission was 0.611 mGy/day; the effective quality factor, 1.64; and the dose equivalent rate, 0.998 mSv/day. The average absorbed dose rates are 0.158 mGy/min for GCR particles and 3.67 mGy/min for trapped particles. The effective quality factors are 2.48 for GCR particles and 1.19 for trapped particles. The absorbed doses obtained by the RRMD-III and a conventional method using TLD (Mg(2)SiO(4)), which was placed around the RRMD-III were compared. It was found that the TLDs showed a lower efficiency, just 58% of absorbed dose registered by the RRMD-III.

NASA Discipline Radiation Health↗

Cavity Controlled Upconversion in CdSe Nanoplatelet Polaritons

Exciton-polaritons provide a versatile platform for investigating quantum electrodynamics effects in chemical systems, such as polariton-altered chemical reactivity. However, using polaritons in chemical contexts will require a better understanding of their photophysical properties under ambient conditions, where chemistry is typically performed. Here, we used cavity quality factor to control strong light–matter interactions and in particular the excited state dynamics of colloidal CdSe nanoplatelets (NPLs) coupled to a Fabry– Pérot optical cavity. With increasing cavity quality factor, we observe significant population of the upper polariton (UP) state, exemplified by the rare observation of substantial UP photoluminescence (PL). Excitation of the lower polariton (LP) states results in upconverted PL emission from the UP branch due to efficient exchange of population between the LP, UP and the reservoir of dark states present in collectively coupled polaritonic systems. In addition, we measure time scales for polariton dynamics ~100 ps, implying great potential for NPL based polariton systems to affect photochemical reaction rates. State-of-the-art quantum dynamical simulations show outstanding quantitative agreement with experiments, and thus provide important insight into polariton photophysical dynamics of collectively coupled nanocrystal-based systems. These findings represent a significant step toward the development of practical polariton photochemistry platforms.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effect of low temperature baking in nitrogen on the performance of a niobium superconducting radio frequency cavity

Here, we report the rf performance of a single-cell superconducting radiofrequency cavity after low temperature baking in a nitrogen environment. A significant increase in quality factor has been observed when the cavity was heat treated in the temperature range of 120-160 °C with a nitrogen partial pressure of ~25 mTorr. This increase in quality factor as well as the Q-rise phenomenon (anti-Q-slope) is similar to those previously obtained with high temperature nitrogen doping as well as titanium doping. In this study, a cavity N 2 -treated at 120 °C and at 140 °C, showed no degradation in accelerating gradient, however the accelerating gradient was reduced by ~25% with a 160 °C N 2 treatment, compared to the baseline tests after electropolishing. Sample coupons treated in the same conditions as the cavity were analyzed by scanning electron microscope, x-ray photoelectron spectroscopy and secondary ion mass spectroscopy revealed a complex surface composition of Nb 2 O 5 , NbO and NbN (1-x) O x within the rf penetration depth. Furthermore, magnetization measurements showed no significant change on bulk superconducting properties.

36 MATERIALS SCIENCE↗

Development of the first 1 GHz niobium-tin quarter-wave cavity

Niobium-Tin (Nb3Sn) is a promising alternative to pure niobium for low-beta ion accelerators due to low RF losses even at high frequencies. At 4.5 K, the expected Bardeen-Cooper-Schrieffer resistance of Nb3Sn is a few nano-Ohms at 1 GHz, with two orders of magnitude improvement compared to pure niobium. The low Nb3Sn RF losses allow the use of higher frequency, much smaller cavities while maintaining 4.5 K operation that is compatible with cryocoolers. This work aims to demonstrate the feasibility of coating a high-frequency 1 GHz, compact quarter-wave cavity. The development of this cavity has the potential to transform low-beta ion accelerators through size reductions and by enabling the replacement of large helium cryoplants with small plug-in cryocoolers. We have designed, built, and tested a 1GHz Nb3Sn coated quarter-wave cavity. Nb3Sn coating has been performed once by vapor diffusion at Fermilab. Cryogenic cold tests show a quality factor of ~1E9 at low accelerating electric fields or ~7 times higher than the theoretical limit for pure niobium at 1GHz. This first coating does not yet meet our quality factor or gradient goals; however, we plan to continue to develop this cavity.

Zhou, Yang [Argonne]↗

Deepest sensitivity to wavelike dark photon dark matter with superconducting radio frequency cavities

Wavelike, bosonic dark matter candidates like axions and dark photons can be detected using microwave cavities known as haloscopes. Traditionally, haloscopes consist of tunable copper cavities operating in the TM 010 mode, but ohmic losses have limited their performance. In contrast, superconducting radio frequency (SRF) cavities can achieve quality factors of ∼ 10 10 , perhaps 5 orders of magnitude better than copper cavities, leading to more sensitive dark matter detectors. In this paper, we first derive that the scan rate of a haloscope experiment is proportional to the loaded quality factor Q L , even if the cavity bandwidth is much narrower than the dark matter halo line shape. We then present a proof-of-concept search for dark photon dark matter using a nontunable ultrahigh-quality SRF cavity. We exclude dark photon dark matter with kinetic mixing strengths of χ > 1.5 × 10 − 16 for a dark photon mass of m A ′ = 5.35 μ eV , achieving the deepest exclusion to wavelike dark photons by almost an order of magnitude. Published by the American Physical Society 2024

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Passive dosimetry aboard the Mir Orbital Station: internal measurements

Passive radiation dosimeters were exposed aboard the Mir Orbital Station over a substantial portion of the solar cycle in order to measure the change in dose and dose equivalent rates as a function of time. During solar minimum, simultaneous measurements of the radiation environment throughout the habitable volume of the Mir were made using passive dosimeters in order to investigate the effect of localized shielding on dose and dose equivalent. The passive dosimeters consisted of a combination of thermoluminescent detectors to measure absorbed dose and CR-39 PNTDs to measure the linear energy transfer (LET) spectrum from charged particles of LET infinity H2O > or = 5 keV/micrometers. Results from the two detector types were then combined to yield mean total dose rate, mean dose equivalent rate, and average quality factor. Contrary to expectations, both dose and dose equivalent rates measured during May-October 1991 near solar maximum were higher than similar measurements carried out in 1996-1997 during solar minimum. The elevated dose and dose equivalent rates measured in 1991 were probably due to a combination of intense solar activity, including a large solar particle event on 9 June 1991, and the temporary trapped radiation belt created in the slot region by the solar particle event and ensuing magnetic storm of 24 March 1991. During solar minimum, mean dose and dose equivalent rates were found to vary by factors of 1.55 and 1.37, respectively, between different locations through the interior of Mir. More heavily shielded locations tended to yield lower total dose and dose equivalent rates, but higher average quality factor than did more lightly shielding locations. However, other factors such as changes in the immediate shielding environment surrounding a given detector location, changes in the orientation of the Mir relative to its velocity vector, and changes in the altitude of the station also contributed to the variation. Proton and neutron-induced target fragment secondaries, not primary galactic cosmic rays, were found to dominate the LET spectrum above 100 keV/micrometers. This indicates that in low earth orbit, trapped protons in the South Atlantic Anomaly are responsible for the major fraction of the total dose equivalent. c2002 Elsevier Science Ltd. All rights reserved.

NASA Experiment Number 9401620↗

Mirror-smooth surfaces and repair of defects in superconducting RF cavities by mechanical polishing

Mechanical techniques for polishing the inside surface of niobium superconducting radio-frequency (SRF) cavities have been systematically explored. By extending known techniques to fine polishing, mirror-like finishes were produced, with <15 nm RMS (root mean square) roughness over 1 mm2 scan area. This is an order of magnitude less than the typical roughness produced by the electropolishing of niobium cavities. The extended mechanical polishing (XMP) process was applied to several SRF cavities which exhibited equator defects that caused quench at <20 MV m-1 and were not improved by further electropolishing. Cavity optical inspection equipment verified the complete removal of these defects, and minor acid processing, which dulled the mirror finish, restored performance of the defective cells to the high gradients and quality factors measured for adjacent cells when tested with other harmonics. This innate repair feature of XMP could be used to increase manufacturing yield. Excellent superconducting properties resulted after initial process optimization, with quality factor Q of 3 × 1010 and accelerating gradient of 43 MV m-1 being attained for a single-cell TESLA cavity, which are both close to practical limits. Several repaired nine-cell cavities also attained Q > 8 × 109 at 35 MV m-1, which is the specification for the International Linear Collider. Future optimization of the process and pathways for eliminating requirements for acid processing are also discussed.

43 PARTICLE ACCELERATORS↗

Coupling, Q-Factor, and Integration Aspects of Microsphere Applications

With suggested applications varying from microlaser and cavity QED through optical locking of diode lasers to modulators and sensors, high-Q silica microspheres with whispering-gallery (WG) modes so far remain the subject of tabletop feasibility demonstrations. Despite the uniquely high quality-factor and submillimeter dimensions suitable for tight packaging, this novel type of high-finesse cavity still has to be adapted to fiber- and integrated-optic hardware. In the visible and near infrared-band experiments (633-850nm) measuring the ringdown time tau of free oscillations, Q = (0.6 to 0.8 ) x 10(exp 10) has been obtained in silica spheres of diameter -800 microns (corresponding tau = 3 to 4 microseconds). It was proved that under normal laboratory conditions, quality-factor is subject to deterioration within several-minute scale down to (2 ... 3 ) x 10(exp 9). The responsible mechanism was identified as adsorption of a monolayer of atmospheric water, so that preservation of the ultimate Q requires manipulation in dry environment, or fast packaging into sealed devices. Larger Q can be expected closer to minimum of attenuation in fused silica alpha = 0.2 dB/km; Q greater than or equal to 1 x 10(exp 11) at lambda=1.55 microns, with corresponding energy storage time tau approx. 0.1ms. Experiments are currently underway to determine whether this high Q can be realized experimentally. The evident difficulty is that OH-related optical absorption has its peaks located near the reported minimum of attenuation in silica. We can also mention here that some of proposed fiber materials, yet not ready for fiber drawing, have been predicted to have smaller attenuation than fused silica and may be suitable for microsphere fabrication (sodium-magnesium silicate glass, alpha = 0.06dB/km). WG modes possess very small radiative loss (it does not prevent Q-10(exp 20) and more) and therefore are electromagnetically isolated and cannot be excited by free-space beams. If no modification (such as grating) is made on the sphere surface, the coupling has to he provided by an appropriate near-field device. A systematic theoretical approach has been recently developed to quantify the performance of near-field couplers for WG modes. Efficient coupling can be obtained upon fulfillment of two main conditions: (1) mode matching and (2) sufficient coupling strength to provide the buildup of a WG mode with a given intrinsic loss. In other words, the wave in the coupler has to be phase-matched and sufficiently overlapped with the WG mode to provide enough buildup in the cavity. If the coupling efficiency is characterized by the fractional depth K(sup 2) of the resonance dip in intensity transmittance observed upon varying the frequency of the exciting wave in the coupler.

Ilchenko, V. S.↗

Porous silicon ring resonator for compact, high sensitivity biosensing applications

A ring resonator is patterned on a porous silicon slab waveguide to produce a compact, high quality factor biosensor with a large internal surface area available for enhanced recognition of biological and chemical molecules. The porous nature of the ring resonator allows molecules to directly interact with the guided mode. Quality factors near 10,000 were measured for porous silicon ring resonators with a radius of 25 μm. A bulk detection sensitivity of 380 nm/RIU was measured upon exposure to salt water solutions. Specific detection of nucleic acid molecules was demonstrated with a surface detection sensitivity of 4 pm/nM.

47 OTHER INSTRUMENTATION↗

Anomalous bulk viscosity of two-phase fluids and implications for planetary interiors

The irreversible entropy production is calculated for the imposition of a pressure perturbation on a two-phase medium composed of a dilute suspension of droplets (or snowflakes) and a liquid phase of other materials. An absence of metastability is assumed, allowing the relaxation to be dominated by the solute finite diffusivity. The fluid medium was found to display a behavior suggestive of a bulk viscosity near 10 trillion P, a finding that is significant for studies of dissipation in planetary cores for tidal or seismic disturbances. A minimum quality factor for acoustic or tidal pressure oscillations and the accompanying frequency are calculated. An example is provided in terms of helium rain clouds in the deep interiors of giant planets. Additionally, a tidal quality factor of 10 to the 15th is found necessary to account for Io volcanism and resurfacing on Enceladus.

Stevenson, D. J.↗

Evaluation of 2 possible further developments of the UK in-flight radiation warning meter for SSTS

A mass reduction of the moderator and the response to the nucleon flux, responsible for the tissue-star component of the total-dose equivalent rate using a high atomic number material, are discussed. Radiation situations at SST cruising altitudes (approximately 20 km) due to solar proton flares were simulated in the stratosphere and on the ground. Actual stratospheric situations due to galactic cosmic radiation with a limited range of quality factor values (2-4) were encountered during slow ascents by balloons to 36 km. Synthetic situations obtained from high and low energy acclerator radiations were used to obtain radiation distributions having a larger range of quality factor values (11/2-9) than experienced in the stratosphere. The measurements made in these simulations related to the directly ionizing, neutron and tissue-star components of dose-equivalent rate. Due to the restricted range of neutron spectra encountered in the stratosphere, a significant mass reduction of the moderator by 4 kg was made, with the moderator clad with cadmium or some other slow neutron absorber.

Wilson, I. J.↗

Correction of Q Factor Effects for Simultaneous Collection of Elemental Analysis and Relaxation Times by Nuclear Magnetic Resonance

A new method for measurement of elemental analysis by nuclear magnetic resonance (NMR) of unknown samples is discussed in this report as a quick and robust means to measure elemental ratios without the use of internal or external calibration standards. The determination of elemental ratios was done by normalizing the signal intensities by the frequency dependent quality factor (Q) and the gyromagnetic ratios (γ) for each measured nucleus. The correction for the frequency dependence was found by characterizing the output signal of the probe as a function of the quality factor (Q) and the frequency, and the correction for γ was discussed in a previous study. A Carr–Purcell–Meiboom–Gill (CPMG) pulse sequence was used for evaluation of the relative signal intensities, which allows for derivation of elemental ratios, and was correspondingly used to simultaneously measure the T 2 * of samples for an added parameter for more accurate identification of unknown samples.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗