Search NASA⌕ Search

SEARCH · Search NASA

Results for “Quantitative analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Quantitative Analysis of Spaceflight Drug Stability Data to Support a Predictive Pharmaceutical Testing Strategy

To systematically quantify the time-dependent effect of spaceflight on active pharmaceutical ingredient (API) degradation, data were extracted from available published and unpublished spaceflight drug stability studies. Seven studies were identified that investigated the stability of individual medications following storage aboard crewed spacecraft. Medications stored for up to 2.4 years in low earth orbit (LEO) show limited change in API potency that, in all cases, falls within 10% of matched terrestrial controls, and within 5% of controls for the most drugs. This investigation shows that spaceflight is associated with a ~1.5-fold increase in the degradation rate relative to lot-matched terrestrial controls. Spaceflight is associated with an increased probability of drug failure over time; however, the incremental increase in degradation risk associated with spaceflight is minor compared to the baseline risk associated with terrestrial controls. Since most drugs across all NASA-supported studies were repackaged solid oral formulations that had been removed from protective manufacturer packaging, it is likely that prolonged exposure to atmospheric factors during both terrestrial and spaceflight treatments is a key contributor to degradation. Unique spaceflight environmental factors, particularly ionizing radiation and elevated CO2, may contribute to the additional cumulative effect of spaceflight. The results of this study show that the effect of spaceflight on drug stability is minor relative to the terrestrial baseline; however, the degradation rate and time-dependent failure of terrestrial controls highlights an extremely critical need to evaluate the effect of current repackaging methods and development of operationally appropriate methods to protected repackaged solid oral medications from environmental factors that mediate degradation.

J F Reichard↗

Quantitative Analysis of Spectral Impacts on Silicon Photodiode Radiometers

Inexpensive broadband pyranometers with silicon photodiode detectors have a non-uniform spectral response over the spectral range of 300-1100 nm. The response region includes only about 70% to 75% of the total energy in the terrestrial solar spectral distribution from 300 nm to 4000 nm. The solar spectrum constantly changes with solar position and atmospheric conditions. Relative spectral distributions of diffuse hemispherical irradiance sky radiation and total global hemispherical irradiance are drastically different. This analysis convolves a typical photodiode response with SMARTS 2.9.5 spectral model spectra for different sites and atmospheric conditions. Differences in solar component spectra lead to differences on the order of 2% in global hemispherical and 5% or more in diffuse hemispherical irradiances from silicon radiometers. The result is that errors of more than 7% can occur in the computation of direct normal irradiance from global hemispherical irradiance and diffuse hemispherical irradiance using these radiometers.

14 SOLAR ENERGY↗

Quantitative Analysis of Clustered DNA Damages Induced by Silicon Beams of Different Kinetic Energy

Humans may b exposed to highly energetic charged particle radiation as a result of medical treatments, occupational activitie or accidental events. In recent years, our increasing presence and burgeoning interest in space exploration beyond low Earth orbit has led to a large increase in the research of the biological effects ofcharged particle radiation typical of that encountered in the space radiation environment. The study of the effects of these types of radiation qualities in terms ofDNA damage induction and repair is fundamental to understand mechanisms both underlying their greater biological effectiveness as we)) as the short and long term risks of health effects such as carcinogenesis, degen rative diseases and premature aging. Charged particle radiation induces a variety of DNA alterations, notably bistranded clustered damages, defined as two or more closely-opposed strand break , oxidized bases or abasic sites within a few helical turns. The induction of such highly complex DNA damage enhances the probability of incorrect or incomplete repair and thus constitutes greater potential for genomic instability, cell death and transformation.

61 RADIATION PROTECTION AND DOSIMETRY↗

Quantitative analysis of supported membrane composition using the NanoSIMS

We have improved methods reported earlier [1] for sample preparation, imaging and quantifying components in supported lipid bilayers using high-resolution secondary ion mass spectrometry performed with the NanoSIMS 50. By selectively incorporating a unique stable isotope into each component of interest, a component-specific image is generated from the location and intensity of the unique secondary ion signals exclusively produced by each molecule. Homogeneous supported lipid bilayers that systematically varied in their isotopic enrichment levels were freeze-dried and analyzed with the NanoSIMS 50. The molecule-specific secondary ion signal intensities had an excellent linear correlation to the isotopically labeled lipid content. Statistically indistinguishable calibration curves were obtained using different sample sets analyzed months apart. Fluid bilayers can be patterned using lithographic methods and the composition of each corralled region varied systematically by simple microfluidic methods. The resulting composition variations can be imaged and quantified. This approach opens the possibility of imaging and quantifying the composition of microdomains within membranes, including protein components, without using bulky labels and with very high lateral resolution and sensitivity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗