Search NASA⌕ Search

SEARCH · Search NASA

Results for “RADIOACTIVE SOURCES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Remote detection of radioactive material using mid-IR laser–driven electron avalanche

Remote detection of a distant, shielded sample of radioactive material is an important goal, but it is made difficult by the finite spatial range of the decay products. Here, we present a proof-of-principle demonstration of a remote detection scheme using mid-infrared (mid-IR) (λ = 3.9 μm) laser–induced avalanche breakdown of air. In the scheme’s most basic version, we observe on-off breakdown sensitivity to the presence of an external radioactive source. In another realization of the technique, we correlate the shift of the temporal onset of avalanche to the degree of seed ionization from the source. We present scaling of the interaction with laser intensity, verify observed trends with numerical simulations, and discuss the use of mid-IR laser–driven electron avalanche breakdown to detect radioactive material at range.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Methodology for Determining the Concentration of Naturally Occurring Radioactive Materials in an Urban Environment

The detection of radioactive sources in an urban setting is greatly complicated by natural background radiation, which emanates from various materials including roadways, sidewalks, soil, and building exteriors. The method presented and demonstrated here represents an effort to characterize the concentration of naturally occurring radioactive material (NORM) in these types of materials. The location surveyed in this work was the Fort Indiantown Gap Combined Arms Collective Training Facility in Lebanon County, Pennsylvania. Over 70 measurements with a high-purity germanium detector were performed to ascertain the NORM concentrations present in the soil, asphalt, gravel, concrete, and walls found throughout the site. Monte Carlo radiation transport calculations were used to obtain detector responses for these various geometries and materials to convert these measurements into NORM concentration estimates. Lastly, synthetic spectra were simulated using the predicted source terms and compared to actual measurements, showing acceptable agreement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Energy Differential Response of Cancer Cells for Low Dose Irradiation:Impact of Monoenergetic Brachytherapy Sources

Purpose: The purpose of this work was to evaluate the energy differential response of cancer cells under identical dose exposure to asses the relevancy of mono-energetic sources for Brachytherapy treatments. Method and Materials: An electron energy spectrum impinging on lived breast cancer cell lines (MDA321) was obtained by placing a 19.65 {micro}Ci {sup 90}Sr/{sup 90}Y radioactive source in front of a non-uniform magnetic field constructed from two 5.08 x 5.0 cm x 2.54 cm neodimium ion permanent dipole magnets with a 1 cm separation gap. The cell lines were placed on the exit pole face of the magnet and were subsequently irradiated with different electron energies ranging from about 0.75 MeV to 1.85 MeV. The energy distribution was accurately measured with a scintillating fiber detector system that provided a 0.5% agreement with ICRU and a 5% energy resolution. The dosimetry was performed using a series of data acquired with a {sup 9}Sr/{sup 90}Y 4.5 mCi SIA-6 eye applicator, 6-21 MeV fixed energies from a Varian 2100 EX linac, EBT Gafchromic and Kodak ERT2 films, and an ion chamber detector. The accuracy of the dose rate obtained at different locations along and away from the magnet inside the cell containers was within 10.7%. Results: The cell lines were irradiated with a 0.5-4 Gy dose range. The data indicate a very strong differential energy response for electrons around 1 MeV (more lethal) compare to those with lesser or greater energy and a survival rate of at most 10% at very low dose (0.5-2 Gy). Conclusion: Mono-energetic Brachytherapy sources may provide a new pathway for radio-therapy treatment optimizations following a dedicated study showing very unusual high lethality in a specific energy window for MDA321 breast cancer cells.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Characterizing the radiation response of Cherenkov glass detectors with isotopic sources

Abstract Cherenkov detectors are widely used for particle identification and threshold detectors in high-energy physics. Glass Cherenkov detectors that are sensitive to beta emissions originating from neutron activation have been demonstrated recently as a potential replacement for activation foils. In this work, we set the groundwork to evaluate large Cherenkov glass detectors for sensitivity to MeV photons through first understanding the measured response of small Cherenkov glass detectors to isotopic gamma-ray sources. Counting and pulse height measurements are acquired with reflected glass Cherenkov detectors read out with a photomultiplier tube. Simulation was used to inform our understanding of the measured results. This simulation included radioactive source decay, radiation interaction, Cherenkov light generation, optical ray tracing, and photoelectron production. Implications for the use of Cherenkov glass detectors to measure low energy gammaray response are discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Monte Carlo calculated TG-60 dosimetry parameters for the {beta}{sup -} emitter {sup 153}Sm brachytherapy source

Purpose: The formalism recommended by Task Group 60 (TG-60) of the American Association of Physicists in Medicine (AAPM) is applicable for {beta} sources. Radioactive biocompatible and biodegradable {sup 153}Sm glass seed without encapsulation is a {beta}{sup -} emitter radionuclide with a short half-life and delivers a high dose rate to the tumor in the millimeter range. This study presents the results of Monte Carlo calculations of the dosimetric parameters for the {sup 153}Sm brachytherapy source. Methods: Version 5 of the (MCNP) Monte Carlo radiation transport code was used to calculate two-dimensional dose distributions around the source. The dosimetric parameters of AAPM TG-60 recommendations including the reference dose rate, the radial dose function, the anisotropy function, and the one-dimensional anisotropy function were obtained. Results: The dose rate value at the reference point was estimated to be 9.21{+-}0.6 cGy h{sup -1} {mu}Ci{sup -1}. Due to the low energy beta emitted from {sup 153}Sm sources, the dose fall-off profile is sharper than the other beta emitter sources. The calculated dosimetric parameters in this study are compared to several beta and photon emitting seeds. Conclusions: The results show the advantage of the {sup 153}Sm source in comparison with the other sources because of the rapid dose fall-off of beta ray and high dose rate at the short distances of the seed. The results would be helpful in the development of the radioactive implants using {sup 153}Sm seeds for the brachytherapy treatment.

60 APPLIED LIFE SCIENCES↗

On the property of measurements with the PTW microLion chamber in continuous beams

Purpose: The performance of liquid ionization chambers, which may prove to be useful tools in the field of radiation dosimetry, is based on several chamber and liquid specific characteristics. The present work investigates the performance of the PTW microLion liquid ionization chamber with respect to recombination losses and perturbations from ambient electric fields at various dose rates in continuous beams. Methods: In the investigation, experiments were performed using two microLion chambers, containing isooctane (C{sub 8}H{sub 18}) and tetramethylsilane [Si(CH{sub 3}){sub 4}] as the sensitive media, and a NACP-02 monitor chamber. An initial activity of approximately 250 GBq {sup 18}F was employed as the radiation source in the experiments. The initial dose rate in each measurement series was estimated to 1.0 Gy min{sup -1} by Monte Carlo simulations and the measurements were carried out during the decay of the radioactive source. In the investigation of general recombination losses, employing the two-dose-rate method for continuous beams, the liquid ionization chambers were operated at polarizing voltages 25, 50, 100, 150, 200, and 300 V. Furthermore, measurements were also performed at 500 V polarizing voltage in the investigation of the sensitivity of the microLion chamber to ambient electric fields. Results: The measurement results from the liquid ionization chambers, corrected for general recombination losses according to the two-dose-rate method for continuous beams, had a good agreement with the signal to dose linearity from the NACP-02 monitor chamber for general collection efficiencies above 70%. The results also displayed an agreement with the theoretical collection efficiencies according to the Greening theory, except for the liquid ionization chamber containing isooctane operated at 25 V. At lower dose rates, perturbations from ambient electric fields were found in the microLion chamber measurement results. Due to the perturbations, measurement results below an estimated dose rate of 0.2 Gy min{sup -1} were excluded from the present investigation of the general collection efficiency. The perturbations were found to be more pronounced when the chamber polarizing voltage was increased. Conclusions: By using the two-dose-rate method for continuous beams, comparable corrected ionization currents from experiments in low and medium energy photon beams can be achieved. However, the valid range of general collection efficiencies has been found to vary in a comparison between experiments performed in continuous beams of 120 kVp x ray, and the present investigation of 511 keV annihilation photons. At very high dose rates in continuous beams, there are presently no methods that can be used to correct for general recombination losses and at low dose rates the microLion chamber may be perturbed by ambient electric fields. Increasing the chamber polarizing voltage, which diminishes the general recombination effect, was found to increase the microLion chamber sensitivity to ambient electric fields. Prudence is thus advised when employing the microLion chamber in radiation dosimetry, as ambient electric fields of the strength observed in the present work may be found in many common situations. Due to uncertainties in the theoretical basis for recombination losses in liquids, further studies on the underlying theories for the initial and general recombination effect are needed if liquid ionization chambers are to become a viable option in high precision radiation dosimetry.

60 APPLIED LIFE SCIENCES↗

The Auger Radioisotope Microscope: an instrument for characterization of Auger electron multiplicities and energy distributions

We describe a new instrument, the Argonne Auger Radioisotope Microscope (ARM), capable of characterizing the Auger electron (AE) emission of radionuclides, including candidates relevant in nuclear medicine. Our approach relies on event-by-event ion–electron coincidence, time-of-flight, and spatial readout measurement to determine correlated electron multiplicity and energy distributions of Auger decays. We present a proof-of-principle measurement with the ARM using x-ray photoionization of stable krypton beyond the K-edge and identify a bifurcation in the electron multiplicity distribution depending on the emission of K-LX electrons. Extension of the ARM to the characterization of radioactive sources of AE emissions is enabled by the combination of two recent developments: (1) cryogenic buffer gas beam technology to introduce Auger emitters into the detection region with well-defined initial conditions, and (2) large-area micro-channel plate detectors with multi-hit detection capabilities to simultaneously detect multiple electrons emitted in a single decay.

Auger emitters↗

Loading Capabilities of Irradiated 3-D Printed Polymers

Gamma radiation is the emission of a high-energy photon from a radioactive source. The photon then interacts with an atom potentially damaging it. While time has shown that gamma radiation has a little effect on metals, the same cannot be said about plastic. The use of these types of materials in radioactive areas has increased for many reasons ranging from the weight difference between plastics and metals to the costs associated with doing so. For example, a potential use for radiation resistant plastics could be longer lasting, cost effective, and light weight radiation detection devices sent to probe an area that may present unsafe conditions for humans to survey. For these reasons and more, finding a plastic polymer that can withstand radiation for an extended period of time would make a great impact on the nuclear industry. In this experiment, two different polymers will undergo a series of strength tests before and after being exposed to radiation after different amounts of time up to two weeks. There are two sets of plastic polymers that will be used. Each set will consist of an nonirradiated, control subset, and subsets subject to radiation for one day, one week, and two weeks. The radiation source is 1100 Ci cobalt- 60. The specimens are placed on a foam platform such that they will be exposed as evenly as possible. They are then lowered into the radiation chamber where they are surround by cobalt-60 sources and irradiated for the given amount of time. The specimens will be tested for tensile strength and flexural strength according to ASTM standards. For tensile testing, the specimen has a 'dog bone' shape. The specimen is gripped at the wide ends, and pulled away from the center at a constant rate until failure. To test flexural strength, the specimens will be subject to a 3-point bend test. The specimen is held in place by three points, center top side and both ends bottom side. Load is applied at a constant rate on the center of the specimen until failure. The calculations to be considered for comparison after performing these tests include the tensile strength and stress, elongation, flexural stress and strain, and elasticity. Once these tests are completed, testing specimens that have been 3D printed with different print orientations will be considered and tested. The results from both experiments will help create strong, radiation resistant products in a expeditious manner that could really push the current limitations and expand the use of radiation resistant material.

36 MATERIALS SCIENCE↗

Pulsational Pair-instability Model for Superluminous Supernova PTF12dam:Interaction and Radioactive Decay

Being a superluminous supernova, PTF12dam can be explained by a {sup 56}Ni-powered model, a magnetar-powered model, or an interaction model. We propose that PTF12dam is a pulsational pair-instability supernova, where the outer envelope of a progenitor is ejected during the pulsations. Thus, it is powered by a double energy source: radioactive decay of {sup 56}Ni and a radiative shock in a dense circumstellar medium. To describe multicolor light curves and spectra, we use radiation-hydrodynamics calculations of the STELLA code. We found that light curves are well described in the model with 40 M {sub ⊙} ejecta and 20–40 M {sub ⊙} circumstellar medium. The ejected {sup 56}Ni mass is about 6 M {sub ⊙}, which results from explosive nucleosynthesis with large explosion energy (2–3)×10{sup 52} erg. In comparison with alternative scenarios of pair-instability supernova and magnetar-powered supernova, in the interaction model, all the observed main photometric characteristics are well reproduced: multicolor light curves, color temperatures, and photospheric velocities.

79 ASTRONOMY AND ASTROPHYSICS↗

Silicon-Equivalent Neutron Dose Estimations

Radiation transport calculations are often used to estimate dose or exposure to components and personnel surrounding a radiation source. The sources for these calculations are decaying radionuclides within the various nuclear materials. Under long-term radiation exposure, some components may show signs of material damage such as hardening, cracking, discoloration, etc. resulting from the dose received from nearby radioactive sources. Radiation dose quantities are a useful means to correlate material damage or degradation to radiation interactions. The degradation is often dependent on how incident radiation interacts and deposits energy into the material. This dependence implies that radiation dose should be properly defined for the material effect of interest. Generic dose quantities, such as total energy deposited, may not necessarily correlate well for degradation of any given material.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Sensitivity calibration of a Carestream HPX-1 image plate scanner

There is a need to measure the sensitivity of the image plate scanners used to scan Z shot data. The Carestream HPX-1 image plate scanner was tested, and its performance was characterized to determine the system sensitivity in terms of signal per incident photon as a function of x-ray energy. A Manson source was used to simultaneously expose an Amptek x-ray multi-channel analyzer and image plates, allowing for a comparison of the counts as a function of energy to the signal recorded on the image plates. NIST-certified radioactive sources were used to assign an absolute sensitivity. Results indicate that the HPX-1 scanner response matches the shape of the modeled response, allowing for absolute scaling using NIST-certified radioisotope sources. The HPX-1 scanner shows a stable response with measurements taken over one week. In contrast, the sensitivity of the DITABIS scanner was characterized using the same approach, but it exhibits changes in its response that varied by more than 50% over the span of 4 days.

42 ENGINEERING↗

Security of Mobile Radiological Sources: Overview of Industry Applied Technologies

Small radiological sources used in industrial settings recurrently require transit between job sites. Securing these sources, while stationary, can be addressed with standard security approaches and equipment. Transport of these sources increases the risk and complexity of managing and maintaining control of these sources. Implementing methodologies to securely monitor and locate sources improves response and resolution of anomalous events during transit. The Mobile Source Transit Security (MSTS) system was developed to improve security and provide situational awareness of these mobile sources throughout their job cycle. The MSTS development effort focused on creating a set of systems that could be successfully implemented in industrial radiography and well-logging applications. The MSTS team worked to address source presence and location through use and storage. The MSTS system monitors radiological sources as they move from the base of operations to the job site and back. The system provides near-real-time monitoring of the mobile source location and status and early notification of source loss or theft by transmitting operational status and alerting anomalous conditions over telematic links worldwide. The MSTS system can trigger an armed response or initiation of search and recovery operations and will automatically alert management and responsible staff if a radioactive source is lost or stolen whether it is on-site, in transport, or in storage.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

SU-F-T-05: Dosimetric Evaluation and Validation of Newlydeveloped Well Chamber for Use in the Calibration of Brachytherapy Sources

Purpose: To evaluate the dosimetric characteristics of newly developed well type ionization chamber and to validate the results with the commercially available calibrated well chambers that are being used for the calibration of brachytherapy sources. Methods: The newly developed well type ionization chamber (BDS 1000) has been designed for the convenient use in brachytherapy which is open to atmospheric condition. The chamber has a volume of 240 cm3 and weight of 2.5 Kg. The calibration of the radioactive source with activities from 0.01 mCi to 20 Ci can be carried out using this chamber. The dosimetric parameters such as leakage current, stability, scattering effect, ion collection efficiency, reference air kerma rate and nominal response with energy were carried out with the BDS 1000 well type ion chamber. The evaluated dosimetric characteristics of BDS1000 well chamber were validated with two other commercially available well chambers (HDR 1000 plus and BTC/3007). Results: The measured leakage current observed was negligible for the newly developed BDS 1000 well type ion chamber. The ion collection efficiency was close to 1 and the response of the chamber was found to be very stable. The determined sweet spot was at 42 mm from bottom of the chamber insert. The reference air kerma rate was found to be 4.634 × 105 Gym2hr-1A-1 for the BDS 1000 well chamber. The overall dosimetric characteristics of BDS 1000 well chamber was in good agreement with the dosimetric properties of other two well chambers. Conclusion: The dosimetric study shows that the newly developed BDS 1000 well type ionization chamber is high sensitive and reliable chamber for reference air kerma strength calibration. The results obtained confirm that this chamber can be used for the calibration of HDR and LDR brachytherapy sources.

07 ISOTOPE AND RADIATION SOURCES↗

KATRIN background due to surface radioimpurities

The goal of the KArlsruhe TRItrium Neutrino (KATRIN) experiment is the determination of the effective electron antineutrino mass with a sensitivity of 0.2 eV/c 2 at 90 % C.L. 1 . This goal can only be achieved with a very low background level in the order of 10 mcps 2 in the detector region of interest. A possible background source are α-decays on the inner surface of the KATRIN Main Spectrometer. Rydberg atoms, produced in sputtering processes accompanying the α-decays, are not influenced by electric or magnetic fields and freely propagate inside the vacuum of the Main Spectrometer. Here, they can be ionized by thermal radiation and the released electrons directly contribute to the KATRIN background. Two α-sources, 223 Ra and 228 Th, were installed at the Main Spectrometer with the purpose of temporarily increasing the background in order to study α-decay induced background processes. In this paper, we present a possible background generation mechanism and measurements performed with these two radioactive sources. Our results show a clear correlation between α-activity on the inner spectrometer surface and background from the volume of the spectrometer. Two key characteristics of the Main Spectrometer background – the dependency on the inner electrode offset potential, and the radial distribution – could be reproduced with this artificially induced background. These findings indicate a high contribution of α-decay induced events to the residual KATRIN background.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

3D Gamma Source Mapping and Intervention Analysis - 19243

3D gamma source mapping and intervention analysis, through Transco Products, Inc.'s RadVision3D{sup R}, uses the N-Visage Scanner{sup TM} by Createc combining laser scanning, optical imaging, and CZT (Cadmium Zinc Telluride) technologies to capture plant geometry, images, and gamma radiation data. By capturing multiple scans in an area of interest a full 3D analysis can be performed using N-Visage Fusion{sup TM} software by Createc which develops a 3D model showing radioactive sources in the environment and allowing various interventions, such as shielding or source removal, to be modeled virtually. The output of a RadVision3D{sup R} project is a scaled virtual environment that the user can 'walk through' on a PC for training and work planning activities. Included in the viewer are dose planes for the as-scanned conditions as well as for each intervention, showing the dose rate at any point in the room. A virtual dosimeter is built into the viewer to allow users to be fully immersed in the environment in which they will be working, without being exposed to actual radiation or other hazardous conditions. This technology can help save dose at operating nuclear power plants when used for planning large work scopes in high radiation areas and is valuable as a characterization tool for decommissioning facilities. Adopters of 3D gamma source mapping and intervention analysis save time, money, and dose by evaluating options well in advance of the performance of any work, and optimizing interventions using accurate modelling techniques to plan work evolutions. (author)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Integrated soft snake robot for gamma spectroscopy of radiologically contaminated ducting

Anticipated growth in the number and complexity of nuclear facilities entering the decommissioning phase of their lifespan requires innovative methods of mitigating radiological and safety hazards for workers. Advancements in robotics provide opportunities for remote characterization of radiologically contaminated ducts and pipes, reducing worker exposure. However, the nuclear decommissioning industry has shown a hesitancy in adopting new technology due to concerns regarding capital costs and a lack of demonstration data in representative environments. This work aims to leverage novel soft robotics to develop and demonstrate a sensor-integrated characterization tool for contaminated ducting systems. Two gamma spectrometers – one scintillation-based and one solid-state – were selected and integrated into a pneumatically-actuated snake-like soft robot using stretchable electronic cabling. The robot was then demonstrated at the Idaho National Laboratory’s Critical Infrastructure Test Range Complex. The robot maneuvered through a pseudo-constrained corridor containing several sealed sources and the integrated spectrometers collected spectra at various points along the path of travel. Both spectrometers successfully collected spectra with identifiable, isotope-specific peaks. To evaluate the effect of contamination buildup on the collected spectra, the robot with the integrated scintillation detector was tested using a liquid radioactive source. The resulting spectra showed little detection interference from the liquid contamination; however, a short-lived isotope was used which may not be representative of longer-lived contamination.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Quantitative Measurements of X-ray Intensity

This chapter describes the characterization of several X-ray sources and their use in calibrating different types of X-ray cameras at National Security Technologies, LLC (NSTec). The cameras are employed in experimental plasma studies at Lawrence Livermore National Laboratory (LLNL), including the National Ignition Facility (NIF). The sources provide X-rays in the energy range from several hundred eV to 110 keV. The key to this effort is measuring the X-ray beam intensity accurately and traceable to international standards. This is accomplished using photodiodes of several types that are calibrated using radioactive sources and a synchrotron source using methods and materials that are traceable to the U.S. National Institute of Standards and Technology (NIST). The accreditation procedures are described. The chapter begins with an introduction to the fundamental concepts of X-ray physics. The types of X-ray sources that are used for device calibration are described. The next section describes the photodiode types that are used for measuring X-ray intensity: power measuring photodiodes, energy dispersive photodiodes, and cameras comprising photodiodes as pixel elements. Following their description, the methods used to calibrate the primary detectors, the power measuring photodiodes and the energy dispersive photodiodes, as well as the method used to get traceability to international standards are described. The X-ray source beams can then be measured using the primary detectors. The final section then describes the use of the calibrated X-ray beams to calibrate X-ray cameras. Many of the references are web sites that provide databases, explanations of the data and how it was generated, and data calculations for specific cases. Several general reference books related to the major topics are included. Papers expanding some subjects are cited.

47 OTHER INSTRUMENTATION↗

Determination of ammonia in ethylene using ion mobility spectrometry

A simple procedure to analyze ammonia in ethylene by ion mobility spectrometry is described. The spectrometer is operated with a silane polymer membrane., 63Ni ion source, H+ (H2O)n reactant ion, and nitrogen drift and source gas. Ethylene containing parts per billion (ppb) (v/v) concentrations of ammonia is pulled across the membrane and diffuses into the spectrometer. Preconcentration or preseparation is unnecessary, because the ethylene in the spectrometer has no noticeable effect on the analytical results. Ethylene does not polymerize in the radioactive source. Ethylene's flammability is negated by the nitrogen inside the spectrometer. Response to ammonia concentrations between 200 ppb and 1.5 ppm is near linear, and a detection limit of 25 ppb is calculated.

NASA Discipline Environmental Health↗