Search NASA⌕ Search

SEARCH · Search NASA

Results for “RAMAN EFFECT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Tunable-Bandwidth Filter System

A tunable-bandwidth filter system (TBFS), now undergoing development, is intended to be part of a remote sensing multispectral imaging system that will operate in the visible and near infrared spectral region (wavelengths from 400 to 900 nm). Attributes of the TBFS include rapid tunability of the pass band over a wide wavelength range and high transmission efficiency. The TBFS is based on a unique integration of two pairs of broadband Raman reflection holographic filters with two rotating spherical lenses. In experiments, a prototype of the TBFS, was shown to be capable of spectral sampling of images in the visible range over a 200 nm spectral range with a spectral resolution of 30 nm. The figure depicts the optical layout of a prototype of the TBFS as part of a laboratory multispectral imaging system for the spectral sampling of color test images in two orthogonal polarizations. Each pair of broadband Raman reflection holographic filters is mounted at an equatorial plane between two halves of a spherical lens. The two filters in each pair are characterized by steep spectral slopes (equivalently, narrow spectral edges), no ripple or side lobes in their pass bands, and a few nanometers of non-overlapping wavelength range between their pass bands. Each spherical lens and thus the filter pair within it is rotated in order to rapidly tune its pass band. The rotations of are effected by electronically controlled, programmable, high-precision rotation stages. The rotations are coordinated by electronic circuits operating under overall supervision of a personal computer in order to obtain the desired variation of the overall pass bands with time. Embedding the filters inside the spherical lenses increases the range of the hologram incidence angles, making it possible to continuously tune the pass and stop bands of the filters over a wider wavelength range. In addition, each spherical lens also serves as part of the imaging optics: The telephoto lens focuses incoming light to a field stop that is also a focal point of each spherical lens. A correcting lens in front of the field stop compensates for the spherical aberration of the spherical lenses. The front surface of each spherical lens collimates the light coming from the field stop. After the collimated light passes through the filter in the spherical lens, the rear surface of the lens focuses the light onto a charge-coupled-device image detector.

Bailey, John W.↗

Impact of Uncertainties and Errors in Converting NWS Radiosonde Hygristor Resistances to Relative Humidity

A set of 2,600 6-second, National Weather Service soundings from NASA's FIRE-II Cirrus field experiment are used to illustrate previously known errors and new potential errors in the VIZ and SDD ) brand relative humidity (RH) sensors and the MicroART processing software. The entire spectrum of RH is potentially affected by at least one of these errors. (These errors occur before being converted to dew point temperature.) Corrections to the errors are discussed. Examples are given of the effect that these errors and biases may have on numerical weather prediction and radiative transfer. The figure shows the OLR calculated for the corrected and uncorrected soundings using an 18-band radiative transfer code. The OLR differences are sufficiently large to warrant consideration when validating line-by-line radiation calculations that use radiosonde data to specify the atmospheric state, or when validating satellite retrievals. in addition, a comparison of observations of RH during FIRE-II derived from GOES satellite, raman lidar, MAPS analyses, NCAR CLASS sondes, and the NWS sondes reveals disagreement in the RH distribution and underlines our lack of an understanding of the climatology of water vapor.

Westphal, Douglas L.↗

Impact of Uncertainties and Errors in Converting NWS Radiosonde Hygristor Resistances to Relative Humidity

A set of 2,600 6-second, National Weather Service soundings from NASA's FIRE-II Cirrus field experiment are used to illustrate previously known errors and new potential errors in the VIZ and SDD brand relative humidity (RH) sensors and the MicroART processing software. The entire spectrum of RH is potentially affected by at least one of these errors. (These errors occur before being converted to dew point temperature.) Corrections to the errors are discussed. Examples are given of the effect that these errors and biases may have on numerical weather prediction and radiative transfer. The figure shows the OLR calculated for the corrected and uncorrected soundings using an 18-band radiative transfer code. The OLR differences are sufficiently large to warrant consideration when validating line-by-line radiation calculations that use radiosonde data to specify the atmospheric state, or when validating satellite retrievals. In addition, a comparison of observations of RE during FIRE-II derived from GOES satellite, raman lidar, MAPS analyses, NCAR CLASS sondes, and the NWS sondes reveals disagreement in the RH distribution and underlines our lack of an understanding of the climatology of water vapor.

Westphal, Douglas L.↗

Photocatalytic Coatings for Exploration and Spaceport Design

This project developed self-cleaning photocatalytic coatings that remove contamination without human intervention. The coatings chemically remove organic contaminants and leave no residue. The photocatalyst will not negatively affect other coating properties, especially corrosion resistance. Titanium dioxide, TiO2, is an extremely popular photocatalyst because of its chemical stability, nontoxicity, and low cost. TiO2 is commonly used in the photocatalytic oxidation of organic matter or pollutants in the gas and liquid phases. However, TiO2 does have some drawbacks. It has limited light absorption because of its large band-gap and suffers from a photonic efficiency of less than 10 percent for organic degradation. Dopants can lower the band-gap and improve efficiency. Since the photocatalytically active form of TiO2 is a nanocrystalline powder, it can be difficult to make a robust coating with enough catalyst loading to be effective. Photocatalysts become active when certain light energy is absorbed. When photons with an energy greater than the band-gap, Eg, (wavelengths shorter than 400 nm) impinge upon the surface of the TiO2, an electron-hole pair is formed. The electron-hole pair oxidizes adsorbed substances either directly or via reactive intermediates that form on the surface, such as hydroxyl radicals (OH) or superoxide ions (O2-). Several factors can influence the band-gap energy of TiO2, two of which are crystal structure and impurities. TiO2 exists as three crystal structures brookite, anatase, and rutile that can be controlled via heat treatment. Anatase is the most photocatalytically active crystal form of TiO2. Doping TiO2 with impurities can alter its band-gap energy, as well as its effectiveness as a catalyst. Depending on their size, dopant atoms can occupy either the substitutional or interstitial lattice positions. Atoms that are relatively large will assume the interstitial positions and create a much greater energy disturbance in the crystal than will smaller atoms that take on the substitutional positions. This energy disturbance narrows the band-gap and thus allows photons with longer wavelengths and smaller energies (such as those in the visible-light spectrum) to create electron-hole pairs. Raman spectroscopy was performed for the purpose of determining the crystal structure and the degree of crystallinity of the TiO2 particles. Reflectance measurements indicated the wavelengths of light absorbed by the different catalysts.

Source record↗

Tunable-Bandwidth Filter System

A tunable-bandwidth filter system (TBFS), now undergoing development, is intended to be part of a remote-sensing multispectral imaging system that will operate in the visible and near infrared spectral region (wavelengths from 400 to 900 nm). Attributes of the TBFS include rapid tunability of the pass band over a wide wavelength range and high transmission efficiency. The TBFS is based on a unique integration of two pairs of broadband Raman reflection holographic filters with two rotating spherical lenses. In experiments, a prototype of the TBFS was shown to be capable of spectral sampling of images in the visible range over a 200-nm spectral range with a spectral resolution of .30 nm. The figure depicts the optical layout of a prototype of the TBFS as part of a laboratory multispectral imaging system for the spectral sampling of color test images in two orthogonal polarizations. Each pair of broadband Raman reflection holographic filters is mounted at an equatorial plane between two halves of a spherical lens. The two filters in each pair are characterized by steep spectral slopes (equivalently, narrow spectral edges), no ripple or side lobes in their pass bands, and a few nanometers of non-overlapping wavelength range between their pass bands. Each spherical lens and thus the filter pair within it is rotated in order to rapidly tune its pass band. The rotations of the lenses are effected by electronically controlled, programmable, high-precision rotation stages. The rotations are coordinated by electronic circuits operating under overall supervision of a personal computer in order to obtain the desired variation of the overall pass bands with time. Embedding the filters inside the spherical lenses increases the range of the hologram incidence angles, making it possible to continuously tune the pass and stop bands of the filters over a wider wavelength range. In addition, each spherical lens also serves as part of the imaging optics: The telephoto lens focuses incoming light to a field stop that is also a focal point of each spherical lens. A correcting lens in front of the field stop compensates for the spherical aberration of the spherical lenses. The front surface of each spherical lens collimates the light coming from the field stop. After the collimated light passes through the filter in the spherical lens, the rear surface of the lens focuses the light onto a charge-coupled-device image detector.

Aye, Tin↗

Method for measuring temperatures and densities in hypersonic wind tunnel air flows using laser-induced O2 fluorescence

Laser-induced fluorescence in oxygen, in combination with Raman scattering, is shown to be an accurate means by which temperature, density, and their fluctuations owing to turbulence can be measured in air flows associated with high-speed wind tunnels. For temperatures above 60 K and densities above 0.01 amagat, the uncertainties in the temperature and density measurements can be less than 2 percent, if the signal uncertainties are dominated by photon statistical noise. The measurements are unaffected by collisional quenching and can be achieved with laser fluences for which nonlinear effects are insignificant. Temperature measurements using laser-induced fluorescence alone have been demonstrated at known densities in the range of low temperatures and densities which are expected in a hypersonic wind tunnel.

Laufer, Gabriel↗

Development of a Premixed Combustion Capability for Scramjet Combustion Experiments

Hypersonic air-breathing engines rely on scramjet combustion processes, which involve high speed, compressible, and highly turbulent flows. The combustion environment and the turbulent flames at the heart of these engines are difficult to simulate and study in the laboratory under well controlled conditions. Typically, wind-tunnel testing is performed that more closely approximates engine testing rather than a careful investigation of the underlying physics that drives the combustion process. The experiments described in this paper, along with companion data sets being developed separately, aim to isolate the chemical kinetic effects from the fuel-air mixing process in a dual-mode scramjet combustion environment. A unique fuel injection approach is taken that produces a nearly uniform fuel-air mixture at the entrance to the combustor. This approach relies on the precombustion shock train upstream of the dual-mode scramjet combustor. A stable ethylene flame anchored on a cavity flameholder with a uniformly mixed combustor inflow has been achieved in these experiments allowing numerous companion studies involving coherent anti-Stokes Raman scattering (CARS), particle image velocimetry (PIV), and planar laser induced fluorescence (PLIF) to be performed.

Rockwell, Robert D.↗

The growth and characterization of Al(x)Ga(1-x)As/Ge heterostructures

The effects of the growth temperature and the Al(x)Ga(1-x)As layer thickness on the structural, optical, and electrical properties of Al(x)Ga(1-x)As/Ge heterostructures grown for photovoltaic applications were investigated using different-thickness (between 1 micron and 5 microns) Al(x)Ga(1-x)As layers grown by MOCVD in the temperature range between 660 and 780 C. Results obtained from double-crystal X-ray rocking curve measurements, electron beam induced current, cross-sectional TEM, Raman spectroscopy, SIMS, and steady-state and time-resolved photoluminescence measurements are presented. It was found that the highest minority carrier lifetime, 2.41 ns, was obtained for T(G) = 780 C, but the lowest interfacial recombination velocity, 1.6 x 10 exp 4, was obtained at 660 C.

Choi, S. W.↗

A method for measuring temperatures and densities in hypersonic wind tunnel air flows using laser-induced O2 fluorescence

Laser-induced fluorescence in oxygen, in combination with Raman scattering, is shown to be an accurate means by which temperature, density, and their fluctuations due to turbulence can be measured in air flows associated with high-speed wind tunnels. For temperatures above 60 K and densities above 0.01 amagat, the uncertainty in the temperature and density measurements can be less than 2 and 3 percent, respectively, if the signal uncertainties are dominated by photon-statistical noise. The measurements are unaffected by collisional quenching and can be achieved with laser fluences for which nonlinear effects are insignificant. Temperature measurements using laser-induced fluorescence alone have been demonstrated at known densities in the range of low temperatures and densities which are expected in a hypersonic wind tunnel.

Laufer, Gabriel↗

Observation of Stratospheric Ozone with NIES Lidar System in Tsukuba, Japan

Lidars are expected to play important roles in an international monitoring network of the stratosphere such as the Network for the Detection of Stratospheric Change (NDSC). The National Institute for Environmental Studies (NIES) in Tsukuba constructed an ozone lidar system in March 1988 and started observation in August 1988. The lidar system has a 2-m telescope and injection locked XeCl and XeF excimer lasers which can measure ozone profiles (15-45 km) and temperature profiles (30-80 km). From December 1991, lidar observations have been carried out in which the second Stokes line of the stimulated Raman scattering of a KrF laser has been used. Ozone profiles obtained with the NIES lidar system are compared with the data provided by the SAGE II satellite sensor. Results showed good agreement for the individual and the zonal mean profiles. Variations of ozone with various time scales at each altitude can be studied using the data obtained with the NIES ozone lidar system. Seasonal variations are easily found at 20 km, 30 km, and 35 km, which are qualitatively understood as a result of dynamical and photochemical effects. Systematic errors of ozone profiles due to the Pinatubo stratospheric aerosols have been detected using multi-wavelength observation.

Nakane, H.↗

Critical behavior in the hydrogen insulator-metal transition

The vibrational Raman spectrum of solid hydrogen has been measured from 77 to 295 K in the vicinity of the recently observed insulator-metal transition and low-temperature phase transition at 150 gigapascals. The measurements provide evidence for a critical point in the pressure-temperature phase boundary of the low-temperature transition. The result suggests that below the critical temperature the insulator-metal transition changes from continuous to discontinuous, consistent with the general criteria originally proposed by Mott (1949) for metallization by band-gap closure. The effect of temperature on hydrogen metallization closely resembles that of the lower-pressure insulator-metal transitions in doped V2O3 alloys.

Hemley, R. J.↗

Evaluation of Vapor Pressure and Ultra-High Vacuum Tribological Properties of Ionic Liquids (2) Mixtures and Additives

Ionic liquids are salts, many of which are typically viscous fluids at room temperature. The fluids are characterized by negligible vapor pressures under ambient conditions. These properties have led us to study the effectiveness of ionic liquids containing both organic cations and anions for use as space lubricants. In the previous paper we have measured the vapor pressure and some tribological properties of two distinct ionic liquids under simulated space conditions. In this paper we will present vapor pressure measurements for two new ionic liquids and friction coefficient data for boundary lubrication conditions in a spiral orbit tribometer using stainless steel tribocouples. In addition we present the first tribological data on mixed ionic liquids and an ionic liquid additive. Post mortem infrared and Raman analysis of the balls and races indicates the major degradation pathway for these two organic ionic liquids is similar to those of other carbon based lubricants, i.e. deterioration of the organic structure into amorphous graphitic carbon. The coefficients of friction and lifetimes of these lubricants are comparable to or exceed these properties for several commonly used space oils.

Morales, Wilfredo↗

Water-vapor absorption line measurements in the 940-nm band by using a Raman-shifted dye laser

We report water-vapor absorption line measurements that are made by using the first Stokes radiation (930-982 nm) with HWHM 0.015/cm generated by a narrow-linewidth, tunable dye laser. Forty-five absorption line strengths are measured with an uncertainty of 6 percent and among them are fourteen strong lines that are compared with previous measurements for the assessment of spectral purity of the light source. Thirty air-broadened linewidths are measured with 8 percent uncertainty at ambient atmospheric pressure with an average of 0.101/cm. The lines are selected for the purpose of temperature-sensitive or temperature-insensitive lidar measurements. Results for these line strengths and linewidths are corrected for broadband radiation and finite laser linewidth broadening effects and compared with the high-resolution transmission molecular absorption.

Chu, Zhiping↗

Microgravity Effects on Nonequilibrium Melt Processing of Neodymium Titanate: Thermophysical Properties, Atomic Structure, Glass Formation and Crystallization

The relationships between materials processing and structure can vary between terrestrial and reduced gravity environments. As one case study, we compare the nonequilibrium melt processing of a rare-earth titanate, nominally 83TiO 2 -17Nd 2 O 3 , and the structure of its glassy and crystalline products. Density and thermal expansion for the liquid, supercooled liquid, and glass are measured over 300–1850 °C using the Electrostatic Levitation Furnace (ELF) in microgravity, and two replicate density measurements were reproducible to within 0.4%. Cooling rates in ELF are 40–110 °C s −1 lower than those in a terrestrial aerodynamic levitator due to the absence of forced convection. X-ray/neutron total scattering and Raman spectroscopy indicate that glasses processed on Earth and in microgravity exhibit similar atomic structures, with only subtle differences that are consistent with compositional variations of ~2 mol. % Nd 2 O 3 . The glass atomic network contains a mixture of corner- and edge-sharing Ti-O polyhedra, and the fraction of edge-sharing arrangements decreases with increasing Nd 2 O 3 content. X-ray tomography and electron microscopy of crystalline products reveal substantial differences in microstructure, grain size, and crystalline phases, which arise from differences in the melt processes.

thermophysical properties↗

An assumed pdf approach for the calculation of supersonic mixing layers

In an effort to predict the effect that turbulent mixing has on the extent of combustion, a one-equation turbulence model is added to an existing Navier-Stokes solver with finite-rate chemistry. To average the chemical-source terms appearing in the species-continuity equations, an assumed pdf approach is also used. This code was used to analyze the mixing and combustion caused by the mixing layer formed by supersonic coaxial H2-air streams. The chemistry model employed allows for the formation of H2O2 and HO2. Comparisons are made with recent measurements using laser Raman diagnostics. Comparisons include temperature and its rms, and concentrations of H2, O2, N2, H2O, and OH. In general, good agreement with experiment was noted.

Baurle, R. A.↗

Morphology and Luminescence Properties of Transition Metal Doped Zinc Selenide Crystals

Zinc selenide is an excellent matrix material to dope with rare-earth and transition metal to achieve mid-infrared luminescence to develop high power lasers. The luminescence, morphology and refractive index is significantly affected by the doping and defects generated due to size and valency of dopants, concentration, growth process and convection during the growth. The aim of the study is to investigate effect of point and line defects generated due to low doping of iron and chromium on the emission and morphology of the zinc selenide. Luminescence and morphological properties of large iron and chromium doped zinc selenide single crystals were studied to evaluate the effect of extremely low residual impurities and defects associated with the doping process. The emission properties following both short wavelength (i.e., ultraviolet; 350 – 370 nm) excitation and longer wavelength (i.e., near infrared; 850 – 870 nm) excitation were characterized. Luminescence emission bands were identified in both doped crystals. In addition to the primary emission bands, satellite peaks and intra-center transitions were also observed. Due to local population defects associated with the residual impurities (ppm to ppb) in the Fe-ZnSe and Cr-ZnSe crystals, peak emission wavelengths were observed to shift. Raman studies using 266 and 532 – nm excitation revealed different positions of longitudinal and transverse peaks for Fe-ZnSe and Cr-ZnSe crystals, associated with different levels of defects due to the different ion sizes. The emission bands were found to decrease in intensity due to recombination of residual impurity co-dopants and complex defects generated during growth and fabrication. Cryogenic temperature analyses revealed a very clean emission band due to freezing of some of the point and line defects. An emission band observed at 980 nm for both crystals at room temperature as well as cryogenic temperatures indicates a vibronic peak in ZnSe. The scanning electron microscopy (SEM) images of the local morphology support the conclusion that small crystallites in doped crystals are also present.

Zinc selenide↗

Design and Study of a LOX/GH2 Throttleable Swirl Injector for Rocket Applications

A LOX/GH2 swirl injector was designed for a 10:1 propellant throttling range. To accomplish this, a dual LOX (liquid oxygen) manifold was used feeding a single common vortex chamber of the swirl element. Hot-fire experiments were conducting for rocket chamber pressures from 80 to 800 psia at a mixture ratio of nominally 6.0 using steady flow, single-point-per-firing cases as well as dynamic throttling conditions. Low frequency (mean) and high frequency (fluctuating) pressure transducer data, flow meter measurements, and Raman spectroscopy images for mixing information were obtained. The injector design, experimental setup, low frequency pressure data, and injector performance analysis will be presented. C efficiency was very high (approximately 100%) at the middle of the throttle-able range with somewhat lower performance at the high and low ends. From the analysis of discreet steady state operating conditions, injector pressure drop was slightly higher than predicted with an inviscid analysis, but otherwise agreed well across the design throttling range. Analysis of the dynamic throttling data indicates that the injector may experience transient conditions that effect pressure drop and performance when compared to steady state results.

Greene, Christopher↗

A New Differential Absorption Lidar to Measure Sub-Hourly Fluctuation of Tropospheric Ozone Profiles in the Baltimore - Washington D.C. Region

Tropospheric ozone profiles have been retrieved from the new ground based National Aeronautics and Space Administration (NASA) Goddard Space Flight Center TROPospheric OZone DIfferential Absorption Lidar (GSFC TROPOZ DIAL) in Greenbelt, MD (38.99 N, 76.84 W, 57 meters ASL) from 400 m to 12 km AGL. Current atmospheric satellite instruments cannot peer through the optically thick stratospheric ozone layer to remotely sense boundary layer tropospheric ozone. In order to monitor this lower ozone more effectively, the Tropospheric Ozone Lidar Network (TOLNet) has been developed, which currently consists of five stations across the US. The GSFC TROPOZ DIAL is based on the Differential Absorption Lidar (DIAL) technique, which currently detects two wavelengths, 289 and 299 nm. Ozone is absorbed more strongly at 289 nm than at 299 nm. The DIAL technique exploits this difference between the returned backscatter signals to obtain the ozone number density as a function of altitude. The transmitted wavelengths are generated by focusing the output of a quadrupled Nd:YAG laser beam (266 nm) into a pair of Raman cells, filled with high pressure hydrogen and deuterium. Stimulated Raman Scattering (SRS) within the focus generates a significant fraction of the pump energy at the first Stokes shift. With the knowledge of the ozone absorption coefficient at these two wavelengths, the range resolved number density can be derived. An interesting atmospheric case study involving the Stratospheric-Tropospheric Exchange (STE) of ozone is shown to emphasize the regional importance of this instrument as well as assessing the validation and calibration of data. The retrieval yields an uncertainty of 16-19 percent from 0-1.5 km, 10-18 percent from 1.5-3 km, and 11-25 percent from 3 km to 12 km. There are currently surface ozone measurements hourly and ozonesonde launches occasionally, but this system will be the first to make routine tropospheric ozone profile measurements in the Baltimore-Washington DC area.

Stimulated Raman Scattering↗