Search NASA⌕ Search

SEARCH · Search NASA

Results for “RIGIDITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Thermal Ratcheting Analysis of TEDS Packed-bed Thermocline Energy Storage Tank - Modeling Methodology and Data Validation

This report investigates numerical modeling methods for thermal ratcheting analysis of packed-bed thermal energy storage (TES) tank and discusses the validation results via comparison with experimental data. The experimental data obtained from various design characteristics of packed-bed thermocline tanks, including the Thermal Energy Distribution System (TEDS) TES tank at Idaho National Laboratory (INL), were used to validate thermal and mechanical models developed in this study to evaluate the thermal ratcheting potential. The thermal model was shown to predict the transient thermal propagation through the packed-bed thermocline tanks generally well. However, a larger discrepancy was observed during the comparison with the data from TEDS, presumably due to the uncertainty of boundary conditions given from the experiment. Based on the comparative study between the thermal model predictions and experimental data of various packed-bed thermocline tanks, potential improvements were suggested for the future TEDS experiments for more precise validation study. For mechanical (thermally induced stress) analysis, two different modeling approaches were tested to evaluate hoop stress applied to the packed-bed TES tank wall, which is a major cause of thermal ratcheting process: (i) infinite rigidity model and (ii) Drucker-Prager (DP) model. The ‘model (i)’ is a conservative method with infinite rigidity assumption of granular filler inside a TES tank, whereas the ‘model (ii)’ is a method that takes into account more realistic processes such as thermal expansion of filler and tank wall as well as inter-particle interactions during the cyclic operation of a packed-bed TES tank. The validity of each modeling method was examined by comparing the numerical simulation with the experimental data obtained from the packed-bed TES tank for Solar One pilot plant. Then, the effects of various model parameters were discussed to evaluate the thermal ratcheting potential of the TEDS TES tank. The preliminary thermal ratcheting analysis implies that the TEDS TES tank will hold its structural integrity during the normal operation cycles.

25 ENERGY STORAGE↗

Smoothed Retarded Potentials and Fields

This note will follow the derivation of the Liénard–Wiechert potentials for a moving charge, which give the entire electromagnetic field generated by that charge including time delays, while concurrently deriving a version for a smoothed charge. The smoothed charge replaces the delta function charge density ρ ∝ δ 3 (x) by a spherically symmetric function f(|x|), so instead of a potential φ ∝ 1/ |x| for a charge at rest, the potential will be the 3D convolution of f with 1/ |x|. The smoothing will be defined in the ‘laboratory frame’ rather than the rest frame of the particle. If a spherically-symmetric distribution is required in a different rest frame, for example the averaged rest frame of a whole particle beam, the particle histories may be Lorentz boosted and the resulting fields Lorentz boosted back. Another motivation for using the lab frame is that if a beam is uniformly accelerated by an electric field, it maintains its lab frame size, rather than shrinking as a rigid object would (if the beam enters an electric field from the side, the particles maintain their time separation and the length actually increases with the beam velocity). Properly defining a charge distribution of fixed size in the changing reference frame of an accelerating particle is somewhat complicated and relates to the concept of Born rigidity.

43 PARTICLE ACCELERATORS↗

Tuning Organic Semiconductor Packing and Morphology through Non-equilibrium Solution Processing (Final Report)

Organic semiconductors (OSCs) are a promising candidate to produce low-cost, large area, and flexible electronics. There has previously been successful development of organic field effect transistors (OFETs), photovoltaics (OPV), and bioelectronics using OSCs. Solution processing of these materials allows for the fabrication of large-area devices in the kinetic crystallization regime. The charge transport capabilities have been shown to depend on the morphology and molecular packing of the OSC within thin films. Our hypothesis is that solution processing conditions may significantly impact OSC morphology and as a result the charge transport. Therefore, this work has focused on obtaining a fundamental understanding of the morphology and molecular packing of OSCs for optimal device performance. Through our work, we have gained a better understanding of how these structural conditions were influenced by the solution processing conditions. Our studies have led to a more systematic understanding of the various parameters that impact OSC morphology. Solution processing leads to non-equilibrium films, thus allowing for the formation of diverse morphologies that are inaccessible by other fabrication methods. Previously, our group has focused on tuning the morphology of small-molecular OSCs [53, 55-57]. However, little work had been devoted to polymer OSCs. There was a lack of detailed studies characterizing the solution-state of polymer OSCs in terms of their conformation, degree of entanglement, polymer aggregation, and chain relaxation dynamics. The solution state properties are also likely to be influenced by the rigidity and molecular weight of the polymer OSCs investigated. Thus, we have focused our attention on gaining a better insight of polymer OSC films and solution processing methods. Through this proposal, our approach is to investigate the correlation between solution-state properties and the morphology of the resulting polymer OSC films. We worked three specific aims: investigate the effects of 1) polymer OSC solution-state properties on final film morphology; 2) molecular additives on the solution-state and final film properties; 3) controlled pre-aggregation in the solution-state in the final film morphology. More rigid and planar polymer backbones should promote interchain charge transport and more efficient interchain hopping between polymer chains. Through tailoring the polymer backbone, polymer sidechains, and molecular weight, we expected the altered solution-state properties to affect the final film morphology. In addition, reducing the entanglements and promoting chain alignment will likely prevent charge carrier trapping through conformation disorders. We thus studied different mechanisms, such as molecular additives, to reduce entanglements in solution. Devices fabricated from these solutions were expected to have improved charge transport abilities. In addition to tailoring the solution-state characteristics of the polymer OSCs, we investigated the effect of solution processing methods on the molecular packing and morphology of polymer OSC films. Two main solution processing techniques, e.g., spin-coating and solution shearing, were employed to fabricate OFETs. Spin coating was employed to prepare OSC films, which produce isotropic films. This technique creates several parameters to tune such as spin coating speed, acceleration, and time. Additionally, our research group developed the solution shearing method, which consists of the solution initially sandwiched between two plates. By sliding the top plate, the solution front is exposed and drying begins. This technique allows for the creation of aligned large crystalline domains. Solution shearing consists of different processing parameters which can affect the final morphology, such as shearing speed, substrate temperature and temperature gradient, distance between both plates, and the tilt angle of the top plate. Due to the complexity of the polymer systems investigated, numerous techniques were employed to characterize the polymer OSC solution state and films. All the materials were characterized using the DOE supported synchrotron X-ray scattering facilities at the Stanford Synchrotron Radiation Lightsource (SSRL). Using grazing incidence X-ray scattering (GIXS) and Near Edge X-ray Absorption Fine Structure (NEXAFS) techniques, the crystalline structure and molecular orientations of the thin films were measured. Optical absorption (UV-Vis) spectroscopy was employed to determine the aggregation state in solution and films of the polymer systems. Polarized UV-Vis also allowed for the determination of the relative degree of polymer chain alignment for solution sheared films. Additionally, various other techniques were used to investigate other properties within the film, such as atomic force microscopy (AFM) and solution rheology. Finally, the device performance is quantified through the fabrication and characterization of OFETs, which will highlight the effects of morphology on charge transport.

36 MATERIALS SCIENCE↗

Multifunctional Nanofiber Reinforcement for Improved Thermomechanical and Chemical Stability of Perovskite Solar Cells

This project focused on the development of metal halide perovskite-polymeric nanofiber nanocomposites for robust and efficient solar cells. Metal halide perovskite solar cells are a potentially disruptive technology with high efficiencies and low-cost solution processability amenable with roll-to-roll fabrication of flexible devices. However, perovskites exhibit extreme brittleness, high internal film stresses, and chemical instabilities that significantly limit service lifetimes under normal operating conditions. To date, most work addressing these shortcomings has been focused on encapsulating devices between thick layers of rigid materials such as glass, which increases the total weight and cost of devices. Furthermore, these rigid and heavy encapsulants do not translate well to emerging solar markets vital for national security, including integrated mobile power, emergency deployments for disaster relief and military engagement, and lightweight power for space. It is therefore critical to improve the thermomechanical and chemical stability of perovskite devices in a way that is compatible with flexible and lightweight substrates. In this project, we integrated nylon-6,6 nanofibers into MAPbI3 to mechanically reinforce the perovskite, demonstrating films that exhibited fracture energies 5-fold greater than pristine MAPbI3 while also maintaining similar power conversion efficiencies due to beneficial light scattering effects from the polymeric nanofibers. These results required successful development of approaches to control the deposition thickness of nanofiber mats down to 100s of nanometers, and to ensure the polymer nanofibers did not inhibit charge transport to the at the perovskite-transport layer interface.

14 SOLAR ENERGY↗

Innovative Interfacial Engineering for Simultaneous Enhancement in Efficiency, Stability, and Reliability in Perovskite Devices

The overarching objective of this project was to increase significantly the mechanical adhesion toughness of the key interfaces in PSCs, thereby improving the durability and reliability of PSCs and minimodules, while simultaneously enhancing their PCE. This is achieved by incorporating rationally-chosen self-assembled monolayers (SAMs) at key PSC interfaces. Inherently scalable methods for the deposition of MHP light-absorber thin films and SAMs are employed to ensure a viable path towards manufacturability. Furthermore, detailed understanding of mechanisms of PSCs and minimodules degradation, and SAMs-induced mitigation, is provided. As part of the project accomplishments, >60% increase in the adhesion toughness of the key PSC interfaces over their SAMs-free control counterparts was achieved. Also, PCEs >20% and >19% in rigid and flexible, respectively, single-junction PSCs (~1 cm 2 area) were achieved. It was shown that <20% PCE loss in flexible PSCs with SAMs can be achieved after bend testing. It was demonstrated that T80 (80% retention of initial PCE) of >5,000 hours in rigid PSCs (~1 cm2 area) can be achieved. Comprehensive understanding of the degradation mechanisms in PSCs was obtained. These strategies were adopted towards developing minimodules. PCE of >21% was obtained in an 6-cm 2 area minimodule, with T91 of 1,000 hours.

14 SOLAR ENERGY↗

UAE6 - Wind Tunnel Tests Data - UAE6 - Sequence Q - Raw Data

Sequence Q: Dynamic Inflow (P) This sequence was designed to characterize the dynamic inflow variation using the five-hole probes that extend upwind of the leading edge of the blade. This test sequence used an upwind, rigid turbine with a 0° cone angle. The wind speeds ranged from 5 m/s to 15 m/s, and data were collected at a 0° yaw angle. The rotor rotated at 72 RPM. Blade and probe pressure measurements were collected. The teeter dampers were replaced with rigid links, and these two channels were flagged as not applicable by setting the measured values in the data file to -99999.99 Nm. The teeter link load cell was pretensioned to 40,000 N. The blade pitch angle was changed from the initial tip pitch angle to the final tip pitch angle at the maximum rate of 67°/s. This angle was maintained for the specified delay time duration. Then the blade was pitched back to the initial pitch angle and held for the specified hold time. This was repeated 20 times. The campaign at 15 m/s was aborted early due to excessive low-speed shaft torque loads. The file length varied depending on the time required to obtain 20 pitch cycles for the specified range of angles. The name convention was the standard format, except for the short campaigns collected to ascertain the functionality of the instrumentation. These points were collected at a 3° pitch angle and use the characters REF in the four digits that normally represent yaw angle.

17 WIND ENERGY↗

UAE6 - Wind Tunnel Tests Data - UAE6 - Sequence W - Raw Data

Sequence W: Extended Blade (F) This test sequence used an upwind, rigid turbine with a 0° cone angle. The wind speed ranged from 5 m/s to 21 m/s, and the yaw angle was held at 0°. The blade pitch angle was 3°. The rotor rotated at 72 RPM. Blade pressure measurements were collected. The five-hole probes were removed and the plugs were installed. Plastic tape 0.03-mm thick was used to smooth the interface between the plugs and the blade. The teeter dampers were replaced with rigid links, and these two channels were flagged as not applicable by setting the measured values in the data file to –99999.99 Nm. The teeter link load cell was pretensioned to 40,000 N. During postprocessing, the probe channels were set to read –99999.99. The standard tip blocks were replaced with blade extensions that created a 5.532-m radius rotor as shown in Appendix A. The extension used the S809 airfoil throughout, and the linear taper of the blade continued along the extension. Note that the blade radius was not changed during post-processing so the pressure tap locations are at the same radial location, but the reference to 30% represents 30% of 5.029 m, not 5.532 m. Throughout this report, references to the blade span are made for the 5.029-m radius, not the 5.532-m radius.

17 WIND ENERGY↗

UAE6 - Wind Tunnel Tests Data - UAE6 - Sequence 5 - Raw Data

Sequence 5: Sweep Wind Speed (F,P) This test sequence used an upwind, rigid turbine with a 0° cone angle. The wind speed was ramped from 5 m/s to 25 m/s by the wind tunnel operator. This was repeated with a decreasing ramp. The yaw angle was maintained at 0°. The blade tip pitch was 3° or 6°. The rotor rotated at 72 RPM. Blade pressure and probe measurements were collected for both pitch angles. The five-hole probes were removed and the plugs were installed for another 3° pitch case. Plastic tape 0.03 mm thick was used to smooth the interface between the plugs and the blade. The teeter dampers were replaced with rigid links, and these two channels were flagged as not applicable by setting the measured values in the data file to –99999.99 Nm. The teeter link load cell was pre-tensioned to 40,000 N. During post-processing, the probe channels were set to read -99999.99. The 6- minute campaigns were named using the sequence designation 5, followed by DN or UP, which indicates the wind speed ramp direction. The next four digits are 0000, and the sequence digit is at the end.

17 WIND ENERGY↗

UAE6 - Wind Tunnel Tests Data - UAE6 - Sequence E - Raw Data

Sequence E: Yaw Releases (P) This test sequence used a downwind, rigid turbine with a 3.4° cone angle. The wind speeds ranged from 7 m/s to 17 m/s. Initial yaw angles of ±90° were achieved. The blade tip pitch was 3°. The rotor rotated at 72 RPM. Blade and probe pressure measurements were collected. The teeter dampers were replaced with rigid links, and these two channels were flagged as not applicable by setting the measured values in the data file to –99999.99 Nm. The teeter link load cell was pre-tensioned to 40,000 N. The turbine was positioned at each specified yaw angle. A 30- second data set was collected with the yaw brake engaged. These points used a letter for the last digit beginning with A and proceeding through the alphabet as repeat points were needed. These points were plotted and compared to ascertain the functionality of the instrumentation. The files ending in numbers beginning with 0 and increasing with each repetition represent yaw release points. Once the fixed-position yaw test was complete, the yaw drive was engaged to hold the turbine. The yaw brake was released, and the yaw drive was disabled allowing the turbine to yaw freely. The yaw drive was disabled about 5 seconds into the campaign, and the turbine was allowed to yaw freely for the rest of the 30-second duration. When the yaw drive is disabled, no torque is applied to the motor, and the inertia and yawing force of the nacelle and rotor overcomes the friction and inertia of the yaw gear and motor. The yaw releases were repeated five times at each condition. Four additional campaigns were collected to determine the turbine’s natural yaw error by releasing the brake at 0° yaw error. These file names use the E designation, followed by two digits for wind speed, followed by XXXX, followed by the repetition digit.

17 WIND ENERGY↗

UAE6 - Wind Tunnel Tests Data - UAE6 - Sequence F - Raw Data

Sequence F: Downwind High Cone (F) This test sequence used a downwind, rigid turbine with an 18° cone angle. The wind speed ranged from 10 m/s to 20 m/s. Excessive inertial loading due to the high cone angle prevented operation at lower wind speeds. Yaw angles of ±20° were achieved. The blade tip pitch was 3°. The rotor rotated at 72 RPM. Blade and probe pressure measurements were collected. The teeter dampers were replaced with rigid links, and these two channels were flagged as not applicable by setting the measured values in the data file to –99999.99 Nm. The teeter link was replaced with a shorter bar so the load cell was not installed during this test. However, the teeter link load cell channel was flagged as not applicable by setting the measured values in the data file to -99999.99 N.

17 WIND ENERGY↗

UAE6 - Wind Tunnel Tests Data - UAE6 - Sequence K - Raw Data

Sequence K: Step AOA, Probes (P) This sequence was designed to quantify the 3-D blade static angle-of-attack response in the presence of rotational influences by varying the blade pitch angle. Sequence K used an upwind, rigid turbine with a 0° cone angle. The wind speeds ranged from 6 m/s to 20 m/s, and data were collected at yaw angles of 0° and 30°. The rotor rotated at 72 RPM. Blade and probe pressure measurements were collected. The teeter dampers were replaced with rigid links, and these two channels were flagged as not applicable by setting the measured values in the data file to -99999.99 Nm. The teeter link load cell was pre-tensioned to 40,000 N. The blade pitch angle ramped continuously at 0.18°/s over a wide range of increasing and decreasing pitch angles. A step sequence was also performed. The blade pitch was stepped 5°, the flow was allowed to stabilize, and the pitch angle was held for 8 seconds. Then the pitch angle step was repeated. Again, a wide range of pitch angles was obtained, both increasing and decreasing. The file lengths for this sequence varied from 96 seconds to 6 minutes, depending on the pitch angle range. Some short points were collected at 0° yaw and 3° pitch to verify the functionality of the instrumentation. The file name convention used the initial letter K, followed by two digits specifying wind speed, followed by two digits for yaw angle, followed by RU, RD, or ST, followed by the repetition digit. The angle-of-attack motion was differentiated by RU (ramp up), RD (ramp down), and ST (step down then step up). This sequence is related to sequences L and R.

17 WIND ENERGY↗

UAE6 - Wind Tunnel Tests Data - UAE6 - Sequence 7 - Raw Data

Sequence 7: Shroud Operating (P) This test sequence used a downwind, rigid turbine with a 3.4° cone angle. The wind speed ranged from 5 m/s to 25 m/s. Turntable angles from 0° to 30° were achieved, but the yaw error angle was maintained at 0° by adjusting the nacelle yaw. The blade tip pitch was 3°. The rotor rotated at 72 RPM. Blade and probe pressure measurements were collected. The teeter dampers were replaced with rigid links, and these two channels were flagged as not applicable by setting the measured values in the data file to –99999.99 Nm. The teeter link load cell was pre-tensioned to 40,000 N. An airfoil-shaped aluminum shroud was placed on the tower below the 34% span five-hole probe. It extended below the 91% span five-hole probe. The turntable angle was adjusted to position the shroud at various angles relative to the flow, but the turbine yaw error angle was maintained at 0°. Two additional points were collected where the turntable angle was 0°, and the turbine yaw angle was 20° (71000200) or -20° (710M0200).

17 WIND ENERGY↗

UAE6 - Wind Tunnel Tests Data - UAE6 - Sequence 8 - Raw Data

Sequences 8 and 9: Downwind Sonics (F,P) and Downwind Sonics Parked (P) This test sequence used an upwind, rigid turbine with a 0° cone angle. The wind speed ranged from 5 m/s to 25 m/s. Yaw angles of 0° to 60° were achieved. The blade tip pitch was 3°. The rotor rotated at 72 RPM during Sequence 8, but it was parked during Sequence 9. Blade pressure measurements were collected. The five-hole probes were removed and the plugs were installed. Plastic tape 0.03-mm-thick was used to smooth the interface between the plugs and the blade. The teeter dampers were replaced with rigid links, and these two channels were flagged as not applicable by setting the measured values in the data file to –99999.99 Nm. The teeter link load cell was pre-tensioned to 40,000 N. During post-processing, the probe channels were set to read -99999.99. Sonic anemometers were mounted on a strut downwind of the turbine. The strut was mounted to the T-frame, which was rotated to align the anemometers aft of the 9% and 49% radius locations at hub height. Because of this configuration, the tunnel balance data are considered invalid. Sequence 9 was designed to compare the downwind sonic anemometer readings with the upwind sonic anemometers without interference from the turbine. The rotor was parked with the instrumented blade at 0° azimuth. All pressure measurements obtained in Sequence 9 are invalid because sufficient time for temperature stabilization did not occur, thus all associated data values were flagged as not applicable by setting the measured values in the data file to 0.0000 Pa. This test is further described in Appendix G.

17 WIND ENERGY↗

UAE6 - Wind Tunnel Tests Data - UAE6 - Sequence 9 - Raw Data

Sequences 8 and 9: Downwind Sonics (F,P) and Downwind Sonics Parked (P) This test sequence used an upwind, rigid turbine with a 0° cone angle. The wind speed ranged from 5 m/s to 25 m/s. Yaw angles of 0° to 60° were achieved. The blade tip pitch was 3°. The rotor rotated at 72 RPM during Sequence 8, but it was parked during Sequence 9. Blade pressure measurements were collected. The five-hole probes were removed and the plugs were installed. Plastic tape 0.03-mm-thick was used to smooth the interface between the plugs and the blade. The teeter dampers were replaced with rigid links, and these two channels were flagged as not applicable by setting the measured values in the data file to –99999.99 Nm. The teeter link load cell was pre-tensioned to 40,000 N. During post-processing, the probe channels were set to read -99999.99. Sonic anemometers were mounted on a strut downwind of the turbine. The strut was mounted to the T-frame, which was rotated to align the anemometers aft of the 9% and 49% radius locations at hub height. Because of this configuration, the tunnel balance data are considered invalid. Sequence 9 was designed to compare the downwind sonic anemometer readings with the upwind sonic anemometers without interference from the turbine. The rotor was parked with the instrumented blade at 0° azimuth. All pressure measurements obtained in Sequence 9 are invalid because sufficient time for temperature stabilization did not occur, thus all associated data values were flagged as not applicable by setting the measured values in the data file to 0.0000 Pa. This test is further described in Appendix G.

17 WIND ENERGY↗

UAE6 - Wind Tunnel Tests Data - UAE6 - Sequence H - Raw Data

Sequences H, I, and J: Upwind Baseline (F), Upwind Low Pitch (F), Upwind High Pitch (F) This test sequence used an upwind, rigid turbine with a 0° cone angle. The wind speed ranged from 5 m/s to 25 m/s. Yaw angles of –30 to 180° were achieved at low wind speeds, and angles of ±10° were achieved for high wind speeds. The blade tip pitch was 3° for sequence H, 0° for sequence I, and 6° for sequence J. These three sequences were interleaved during testing because the pitch angle change was easily made by the turbine operator. The rotor rotated at 72 RPM. Blade and probe pressure measurements were collected. The teeter dampers were replaced with rigid links, and these two channels were flagged as not applicable by setting the measured values in the data file to –99999.99 Nm. The teeter link load cell was pretensioned to 40,000 N. In addition to the standard 30-second campaigns, yaw sweeps were done at 7 m/s and 10 m/s. These 6-minute campaigns were collected while the yaw drive rotated the turbine 360° at a rate of 1°/s. The file names for these campaigns use the letter designation, followed by two digits for wind speed, followed by YS, followed by 000.

17 WIND ENERGY↗

UAE6 - Wind Tunnel Tests Data - UAE6 - Sequence I - Raw Data

Sequences H, I, and J: Upwind Baseline (F), Upwind Low Pitch (F), Upwind High Pitch (F) This test sequence used an upwind, rigid turbine with a 0° cone angle. The wind speed ranged from 5 m/s to 25 m/s. Yaw angles of –30° to 180° were achieved at low wind speeds, and angles of ±10° were achieved for high wind speeds. The blade tip pitch was 3° for sequence H, 0° for sequence I, and 6° for sequence J. These three sequences were interleaved during testing because the pitch angle change was easily made by the turbine operator. The rotor rotated at 72 RPM. Blade and probe pressure measurements were collected. The teeter dampers were replaced with rigid links, and these two channels were flagged as not applicable by setting the measured values in the data file to –99999.99 Nm. The teeter link load cell was pre-tensioned to 40,000 N. In addition to the standard 30-second campaigns, yaw sweeps were done at 7 m/s and 10 m/s. These 6-minute campaigns were collected while the yaw drive rotated the turbine 360° at a rate of 1°/s. The file names for these campaigns use the letter designation, followed by two digits for wind speed, followed by YS, followed by 000.

17 WIND ENERGY↗

UAE6 - Wind Tunnel Tests Data - UAE6 - Sequence J - Raw Data

Sequences H, I, and J: Upwind Baseline (F), Upwind Low Pitch (F), Upwind High Pitch (F) This test sequence used an upwind, rigid turbine with a 0° cone angle. The wind speed ranged from 5 m/s to 25 m/s. Yaw angles of –30° to 180° were achieved at low wind speeds, and angles of ±10° were achieved for high wind speeds. The blade tip pitch was 3° for sequence H, 0° for sequence I, and 6° for sequence J. These three sequences were interleaved during testing because the pitch angle change was easily made by the turbine operator. The rotor rotated at 72 RPM. Blade and probe pressure measurements were collected. The teeter dampers were replaced with rigid links, and these two channels were flagged as not applicable by setting the measured values in the data file to –99999.99 Nm. The teeter link load cell was pre-tensioned to 40,000 N. In addition to the standard 30-second campaigns, yaw sweeps were done at 7 m/s and 10 m/s. These 6-minute campaigns were collected while the yaw drive rotated the turbine 360° at a rate of 1°/s. The file names for these campaigns use the letter designation, followed by two digits for wind speed, followed by YS, followed by 000.

17 WIND ENERGY↗

UAE6 - Wind Tunnel Tests Data - UAE6 - Sequence L - Raw Data

Sequence L: Step AOA, Parked (P) This sequence was designed to quantify the 3-D blade static angle-of-attack response in the absence of rotational influences by varying the blade pitch angle. This test sequence used an upwind, rigid turbine with a 0° cone angle. Wind speeds of 20 m/s and 30 m/s were used, and all data were collected at a yaw angle of 0°. The rotor was parked with the instrumented blade fixed at 0° azimuth, and the rotor lock was installed (see Appendix A). Blade and probe pressure measurements were collected. The teeter dampers were replaced with rigid links, and these two channels were flagged as not applicable by setting the measured values in the data file to -99999.99 Nm. The teeter link load cell was pre-tensioned to 40,000 N. The blade pitch angle ramped continuously at 0.18°/s over a wide range of increasing and decreasing pitch angles. A step sequence was also performed. The blade pitch was stepped 5°, the flow was allowed to stabilize, and the pitch angle was held for 8 seconds. Then the pitch angle step was repeated. Again, a wide range of pitch angles was obtained, both increasing and decreasing. The file lengths for this sequence varied from 5 to 10 minutes, depending on the pitch angle range. The file name convention used the initial letter L followed by two digits specifying wind speed, followed by 00 for yaw angle, followed by RU, RD, or ST, followed by the repetition digit. The angle-of-attack motion was differentiated by RU (ramp up), RD (ramp down), and ST (step down, then step up). This sequence is related to sequences K and R.

17 WIND ENERGY↗