Search NASA⌕ Search

SEARCH · Search NASA

Results for “Radiative Parameters”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Helium diffusion in the sun

We calculate improved standard solar models using the new Livermore (OPAL) opacity tables, an accurate (exportable) nuclear energy generation routine which takes account of recent measurements and analyses, and the recent Anders-Grevesse determination of heavy element abundances. We also evaluate directly the effect of the diffusion of helium with respect to hydrogen on the calculated neutrino fluxes, on the primordial solar helium abundance, and on the depth of the convective zone. Helium diffusion increases the predicted event rates by about 0.8 SNU, or 11 percent of the total rate, in the chlorine solar neutrino experiment, by about 3.5 SNU, or 3 percent, in the gallium solar neutrino experiments, and by about 12 percent in the Kamiokande and SNO solar neutrino experiments. The best standard solar model including helium diffusion and the most accurate nuclear parameters, element abundances, and radiative opacity predicts a value of 8.0 SNU +/- 3.0 SNU for the C1-37 experiment and 132 +21/-17 SNU for the Ga - 71 experiment, where the uncertainties include 3 sigma errors for all measured input parameters.

Bahcall, J. N.↗

Mitigation Strategies for Space Radiation Health Risks

Astronauts embarking on missions beyond low Earth orbit (LEO) will be exposed to a radiation field that may increase the risks of developing cancer, cardiovascular diseases, central nervous system disorders, and immune decrements. Operational parameters will be the primary determinants of crew radiation exposure. NASA uses integrated design tools and risk models to optimize these parameters to minimize radiation exposure. NASA is also considering medical countermeasures (MCMs) to reduce radiation-associated health risks. MCMs for potential use in space-based applications can be developed from a variety of sources, including: a) population-based chemoprevention trials against targeted diseases b) drug development efforts focused on treating acute effects from accidental radiation exposures c) drug development to mitigate side effects of radiotherapy d) mechanistic studies of distinct damage caused by high charge (Z) and energy (HZE) radiation. Use of agents developed for other applications, or repurposed, is advantageous because long-term safety in humans is already established.

Huff, Janice L.↗

Radiative transfer of visible radiation in turbid atmosphere

Methods are presented for solving radiative transfer problems; they include the doubling method and the closely related matrix method, iterative method, Chandrasekhar's method of discrete ordinates, and Monte Carlo method. To consider radiation transport through turbid atmosphere, an atmospheric model was developed characterizing aerosols by parameters. Intensity and polarization of radiation in turbid atmospheres is discussed, as well as lower atmospheric heating due to solar radiation absorption by aerosols.

Yamamoto, G.↗

Evaluation of turbulence induced noise in coherent anti-Stokes Raman scattering

The effect of turbulence in a transonic wind tunnel on coherent anti-Stokes Raman scattering is considered. The driving pump and Stokes waves are taken to be coaxially propagating Gaussian beam waves which are focused on the Raman active medium through the turbulent boundary layer of the flow tube. The random index of refraction variations in the layer are modeled as phase perturbations of the driving waves which cause a reduction of the mean on-axis field and an increase in the mean diameter of the beams. Effective Gaussian beam parameters are developed and the radiated anti-Stokes power calculated as a function of the phase screen parameters. A significant reduction in signal strength occurs for realistic estimates of the phase screen parameter appropriate to a confined transonic flow. A method for estimating the signal degradation which could be applied to other experimental situations is presented.

Elliott, R. A.↗

Thermodynamic limits to the efficiency of solar energy conversion by quantum devices

The second law of thermodynamics imposes a strict limitation to the energy converted from direct solar radiation to useful work by a quantum device. This limitation requires that the amount of energy converted to useful work (energy in any form other than heat) can be no greater than the change in free energy of the radiation fields. Futhermore, in any real energy conversion device, not all of this available free energy in the radiation field can be converted to work because of basic limitations inherent in the device itself. A thermodynamic analysis of solar energy conversion by a completely general prototypical quantum device is presented. This device is completely described by two parameters, its operating temperature T sub R and the energy threshold of its absorption spectrum. An expression for the maximum thermodynamic efficiency of a quantum solar converter was derived in terms of these two parameters and the incident radiation spectrum. Efficiency curves for assumed solar spectral irradiance corresponding to air mass zero and air mass 1.5 are presented.

Buoncristiani, A. M.↗

Enthalpy-Based Thermal Evolution of Loops: II. Improvements to the Model

This paper further develops the zero-dimensional (0D) hydrodynamic coronal loop model "Enthalpy-based Thermal Evolution of Loops" (EBTEL) originally proposed by Klimchuk et al (2008), which studies the plasma response to evolving coronal heating. It has typically been applied to impulsive heating events. The basis of EBTEL is the modelling of mass exchange between the corona and transition region and chromosphere in response to heating variations, with the key parameter being the ratio of transition region to coronal radiation. We develop new models for this parameter that now include gravitational stratification and a physically motivated approach to radiative cooling. A number of examples are presented, including nanoflares in short and long loops, and a small flare. It is found that while the evolution of the loop temperature is rather insensitive to the details of the model, accurate tracking of the density requires the inclusion of our new features. In particular, we are able to now obtain highly over-dense loops in the late cooling phase and decreases to the coronal density arising due to stratification. The 0D results are compared to a 1D hydro code (Hydrad). The agreement is acceptable, with the exception of the flare case where some versions of Hydrad can give significantly lower densities. This is attributed to the method used to model the chromosphere in a flare. EBTEL is suitable for general use as a tool for (a) quick-look results of loop evolution in response to a given heating function and (b) situations where the modelling of hundreds or thousands of elemental loops is needed. A single run takes a few seconds on a contemporary laptop.

Cargill, P. J.↗

Problems of rate chemistry in the flight regimes of aeroassisted orbital transfer vehicles

The dissociating and ionizing nonequilibrium flows behind a normal shock wave are calculated for the density and vehicle regimes appropriate for aeroassisted orbital transfer vehicles; the departure of vibrational and electron temperatures from the gas temperature as well as viscous transport phenomena are accounted for. From the thermodynamic properties so determined, radiative power emission is calculated using an existing code. The resulting radiation characteristics are compared with the available experimental data. Chemical parameters are varied to investigate their effect on the radiation characteristics. It is concluded that the current knowledge of rate chemistry leads to a factor-of-4 uncertainty in nonequilibrium radiation intensities. The chemical parameters that must be studied to improve the accuracy are identified.

Park, C.↗

Problems of Rate Chemistry in the Flight Regimes of Aeroassisted Orbital Transfer Vehicles

The dissociating and ionizing nonequilibrium flows behind a normal shock wave are calculated for the density and vehicle regimes appropriate for aeroassisted orbital transfer vehicles; the departure of vibrational and electron temperatures from the gas temperature as well as viscous transport phenomena are accounted for. From the thermodynamic properties so determined, radiative power emission is calculated using an existing code. The resulting radiation characteristics are compared with the available experimental data. Chemical parameters are varied to Investigate their effect on the radiation characteristics. It is concluded that the current knowledge of rate chemistry leads to a factor-of-4 uncertainty In nonequilibrium radiation intensities. The chemical parameters that must be studied to Improve the accuracy are identified.

Park, Chul↗

Application of stepwise multiple regression techniques to inversion of Nimbus 'IRIS' observations.

Exploratory studies with Nimbus-3 infrared interferometer-spectrometer (IRIS) data indicate that, in addition to temperature, such meteorological parameters as geopotential heights of pressure surfaces, tropopause pressure, and tropopause temperature can be inferred from the observed spectra with the use of simple regression equations. The technique of screening the IRIS spectral data by means of stepwise regression to obtain the best radiation predictors of meteorological parameters is validated. The simplicity of application of the technique and the simplicity of the derived linear regression equations - which contain only a few terms - suggest usefulness for this approach. Based upon the results obtained, suggestions are made for further development and exploitation of the stepwise regression analysis technique.

Ohring, G.↗

Solution of the equation of radiative transfer for remote sensing over nonuniform surface reflectivity

An understanding of radiative transfer in the earth's atmosphere is a necessity for the remote sensing of surface reflectivity from satellites and aircraft. The range of the adjacency effect, which represents the effect of bright areas on the radiance above dark areas, is the main parameter that distinguishes atmospheric radiative transfer over a nonuniform surface from that over a uniform one. A radiative transfer model which expresses this range correctly is, therefore, critical for developing remote sensing methods for the case of an atmosphere over a nonuniform surface. The present investigation is concerned with the development of a new approximate solution of the radiative transfer (RT) equation. The solution is not limited to nonabsorbing atmospheres, but it will still be limited to nadir observations. The results compare favorably with Monte Carlo simulations.

Kaufman, Y. J.↗

Success of the Tracking and Data Relay Satellite System (TDRSS)

The paper provides historical data and presents two parameters for evaluating the success of the Tracking and Data Relay Satellite System (TDRSS). The TDRSS provides high rate data from missions such as the Shuttle and Landsats, and lower rate data from missions such as the Solar Mesosphere Explorer and the Earth Radiation Budget Satellite. Two parameters have been established as measurements of the ability of the system to transmit user commands and telemetry data, i.e., availability and proficiency. Availability is the system's readiness to support any and all user requirements 24 hours per day, 7 days per week. Proficiency is the ratio of actual support provided to scheduled support.

Harris, David W.↗

Measurement of Device Parameters Using Image Recovery Techniques in Large-Scale IC Devices

Devices that respond to radiation on a cell level will produce histograms showing the relative frequency of cell damage as a function of damage. The measured distribution is the convolution of distributions from radiation responses, measurement noise, and manufacturing parameters. A method of extracting device characteristics and parameters from measured distributions via mathematical and image subtraction techniques is described.

radiation↗

Real Time Radiation Monitoring Using Nanotechnology

System and method for monitoring receipt and estimating flux value, in real time, of incident radiation, using two or more nanostructures (NSs) and associated terminals to provide closed electrical paths and to measure one or more electrical property change values .DELTA.EPV, associated with irradiated NSs, during a sequence of irradiation time intervals. Effects of irradiation, without healing and with healing, of the NSs, are separately modeled for first order and second order healing. Change values.DELTA.EPV are related to flux, to cumulative dose received by NSs, and to radiation and healing effectivity parameters and/or.mu., associated with the NS material and to the flux. Flux and/or dose are estimated in real time, based on EPV change values, using measured .DELTA.EPV values. Threshold dose for specified changes of biological origin (usually undesired) can be estimated. Effects of time-dependent radiation flux are analyzed in pre-healing and healing regimes.

Li, Jing↗

A Study of Surface Temperatures, Clouds and Net Radiation

This study focused on the seasonal relationships and interactions of climate parameters such as the surface temperatures, net radiation, long wave flux, short wave flux, and clouds on a global basis. Five years of observations (December 1984 to November 1989) from the Earth Radiation Budget Experiment (ERBE) and the International Satellite Cloud Climatology Program (ISCCP) were used to study both seasonal variations and interannual variations by use of a basic radiation budget equation. In addition, the study was extended to include an analysis of the cloud forcing due El-Nino's impact on the ERBE parameters.

Dhuria, Harbans↗

Microwave radiation measurements near the electron plasma frequency of the NASA Lewis bumpy torus plasma

Microwave emission near the electron plasma frequency was observed, and its relation to the average electron density and the dc toroidal magnetic field was examined. The emission was detected using a spectrum analyzer and a 50 omega miniature coaxial probe. The radiation appeared as a broad amplitude peak that shifted in frequency as the plasma parameters were varied. The observed radiation scanned an average plasma density ranging from 10 million/cu cm to 8 hundred million/cu cm. A linear relation was observed betweeen the density calculated from the emission frequency and the average plasma density measured with a microwave interferometer. With the aid of a relative density profile measurement of the plasma, it was determined that the emissions occurred from the outer periphery of the plasma.

Mallavarpu, R.↗

Microwave radiation measurements near the electron plasma frequency of the NASA Lewis Bumpy Torus plasma

Microwave emission near the electron plasma frequency of the NASA Lewis Bumpy Torus plasma has been observed, and its relation to the average electron density and the dc toroidal magnetic field was examined. The emission was detected using a spectrum analyzer and a 50-ohm miniature coaxial probe. The radiation appeared as a broad amplitude peak that shifted in frequency as the plasma parameters were varied. The observed radiation scanned an average plasma density ranging from 20 billion to 800 billion per cu cm. A linear relation was observed between the density calculated from the emission frequency and the average plasma density measured with a microwave interferometer. With the aid of a relative density profile measurement of the plasma, it was determined that the emissions occurred from the outer periphery of the plasma.

Mallavarpu, R.↗

Radiation dependence of inverter propagation delay from timing sampler measurements

A timing sampler consisting of 14 four-stage inverter-pair chains with different load capacitances was fabricated in 1.6-micron n-well CMOS and irradiated with cobalt-60 at 10 rad(Si)/s. For this CMOS process the measured results indicate that the rising delay increases by about 2.2 ns/Mrad(Si) and the falling delay increase is very small, i.e., less than 300 ps/Mrad(Si). The amount of radiation-induced delay depends on the size of the load capacitance. The maximum value observed for this effect was 5.65 ns/pF-Mrad(Si). Using a sensitivity analysis, the sensitivity of the rising delay to radiation can be explained by a simple timing model and the radiation sensitivity of dc MOSFET parameters. This same approach could not explain the insensitivity of the falling delay to radiation. This may be due to a failure of the timing model and/or trapping effects.

Buehler, M. G.↗

Polarimeter Arrays for Cosmic Microwave Background Measurements

We discuss general system architectures and specific work towards precision measurements of Cosmic Microwave Background (CMB) polarization. The CMB and its polarization carry fundamental information on the origin, structure, and evolution of the universe. Detecting the imprint of primordial gravitational radiation on the faint polarization of the CMB will be difficult. The two primary challenges will be achieving both the required sensitivity and precise control over systematic errors. At anisotropy levels possibly as small as a few nanokelvin, the gravity-wave signal is faint compared to the fundamental sensitivity limit imposed by photon arrival statistics, and one must make simultaneous measurements with large numbers, hundreds to thousands, of independent background-limited direct detectors. Highly integrated focal plane architectures, and multiplexing of detector outputs, will be essential. Because the detectors, optics, and even the CMB itself are brighter than the faint gravity-wave signal by six to nine orders of magnitude, even a tiny leakage of polarized light reflected or diffracted from warm objects could overwhelm the primordial signal. Advanced methods of modulating only the polarized component of the incident radiation will play an essential role in measurements of CMB polarization. One promising general polarimeter concept that is under investigation by a number of institutions is to first use planar antennas to separate millimeter-wave radiation collected by a lens or horn into two polarization channels. Then the signals can be fed to a pair of direct detectors through a planar circuit consisting of superconducting niobium microstrip transmission lines, hybrid couplers, band-pass filters, and phase modulators to measure the Stokes parameters of the incoming radiation.

Stevenson, Thomas↗