Search NASA⌕ Search

SEARCH · Search NASA

Results for “Related References”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

First-Principles Calculations of Acoustic and Anharmonic Properties of Ferromagnetic Cu{sub 2}MnZ (Z = Al and In) Heusler Alloys

The acoustic and anharmonic properties of ferromagnetic Cu{sub 2}MnZ (Z = Al and In) Heusler alloys have been investigated by first-principles calculations method. The obtained lattice parameters, magnetic moments, elastic properties are found to be in good agreement with the available experimental values. From the elastic properties, the sound velocities and the related Debye temperatures and minimum thermal conductivities have been obtained for the two alloys. The sound velocities and thermal conductivities of both alloys are found to show significant anisotropy, and the Cu{sub 2}MnAl with small density and large elastic constants has large sound velocities, high Debye temperature, and large thermal conductivities. Also, the effective second-order elastic constants, generalized Grüneisen constants, and nonlinear ultrasonic parameters to characterize anharmonic properties have been studied for the two alloys. These predictions on the acoustic and anharmonic properties can provide a valuable guidance or reference for further related investigations.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Water Level Data from Wells PLM1 and PLM6 for the East River Watershed, Colorado

This dataset (Williams et al., 2020) contains the original un-QA/QC-ed water level data for PLM1 and PLM6 and has been obsoleted. The data contained within this dataset is not to be used. Refer to Faybishenko et al., 2022 (DOI: 10.15485/1866836) for the latest QA/QC-ed data available via ESS-DIVE.This data set contains water level data for the PLM1 and PLM6 wells. PLM1 and PLM6 are location identifiers used by the Watershed Function SFA project for two groundwater monitoring wells along an elevation gradient located along the lower montane life zone of a hillslope near the Pumphouse location. These wells used to monitor subsurface water and carbon inventories and fluxes at the East River Watershed, Colorado, USA. Complete metadata information on the PLM1 and PLM6 wells are available in the related data package reference Varadharajan C, et al (2020). https://doi.org/10.15485/1660962.Data are reported in .csv files per well. The latitude and longitude of each location are given in a file called locations.csv. These data are used for determining the seasonally dependent flow of groundwater under the PLM hillslope. The downslope flow of groundwater in combination with data on groundwater chemistry can be used to estimate rates of solute export from the hillslope to the floodplain and river.These data products are part of the Watershed Function Scientific Focus Area collection effort to further scientific understanding of biogeochemical dynamics from genome to watershed scales.

54 ENVIRONMENTAL SCIENCES↗

Reducing radiation dose to the female breast during CT coronary angiography: A simulation study comparing breast shielding, angular tube current modulation, reduced kV, and partial angle protocols using an unknown-location signal-detectability metric

Purpose: The authors compared the performance of five protocols intended to reduce dose to the breast during computed tomography (CT) coronary angiography scans using a model observer unknown-location signal-detectability metric.Methods: The authors simulated CT images of an anthropomorphic female thorax phantom for a 120 kV reference protocol and five “dose reduction” protocols intended to reduce dose to the breast: 120 kV partial angle (posteriorly centered), 120 kV tube-current modulated (TCM), 120 kV with shielded breasts, 80 kV, and 80 kV partial angle (posteriorly centered). Two image quality tasks were investigated: the detection and localization of 4-mm, 3.25 mg/ml and 1-mm, 6.0 mg/ml iodine contrast signals randomly located in the heart region. For each protocol, the authors plotted the signal detectability, as quantified by the area under the exponentially transformed free response characteristic curve estimator (A-caret{sub FE}), as well as noise and contrast-to-noise ratio (CNR) versus breast and lung dose. In addition, the authors quantified each protocol's dose performance as the percent difference in dose relative to the reference protocol achieved while maintaining equivalent A-caret{sub FE}.Results: For the 4-mm signal-size task, the 80 kV full scan and 80 kV partial angle protocols decreased dose to the breast (80.5% and 85.3%, respectively) and lung (80.5% and 76.7%, respectively) with A-caret{sub FE} = 0.96, but also resulted in an approximate three-fold increase in image noise. The 120 kV partial protocol reduced dose to the breast (17.6%) at the expense of increased lung dose (25.3%). The TCM algorithm decreased dose to the breast (6.0%) and lung (10.4%). Breast shielding increased breast dose (67.8%) and lung dose (103.4%). The 80 kV and 80 kV partial protocols demonstrated greater dose reductions for the 4-mm task than for the 1-mm task, and the shielded protocol showed a larger increase in dose for the 4-mm task than for the 1-mm task. In general, the CNR curves indicate a similar relative ranking of protocol performance as the corresponding A-caret{sub FE} curves, however, the CNR metric overestimated the performance of the shielded protocol for both tasks, leading to corresponding underestimates in the relative dose increases compared to those obtained when using the A-caret{sub FE} metric.Conclusions: The 80 kV and 80 kV partial angle protocols demonstrated the greatest reduction to breast and lung dose, however, the subsequent increase in image noise may be deemed clinically unacceptable. Tube output for these protocols can be adjusted to achieve a more desirable noise level with lesser breast dose savings. Breast shielding increased breast and lung dose when maintaining equivalent A-caret{sub FE}. The results demonstrated that comparisons of dose performance depend on both the image quality metric and the specific task, and that CNR may not be a reliable metric of signal detectability.

61 RADIATION PROTECTION AND DOSIMETRY↗

Phase retrieval in x-ray lensless holography by reference beam tuning

We show the ability to determine the relative phase between the object and a reference scatterer by tuning the overall intensity and phase of the reference wave. The proposed reference-guided phase retrieval algorithm uses the relative phase as a constraint to iteratively reconstruct the object and the reference simultaneously, and thus does not require precisely defined reference structures. The algorithm also features rapid and reliable convergence and overcomes the uniqueness problem. The method is demonstrated by a soft-x-ray coherent imaging experiment that utilizes a large micrometer-sized reference structure that can be turned on and off, yielding an object image with resolution close to the reconstruction pixel size of 21 nm.

47 OTHER INSTRUMENTATION↗

Measuring the activity of BioBrick promoters using an in vivo reference standard

The engineering of many-component, synthetic biological systems is being made easier by the development of collections of reusable, standard biological parts. However, the complexity of biology makes it difficult to predict the extent to which such efforts will succeed. As a first practical example, the Registry of Standard Biological Parts started at MIT now maintains and distributes thousands of BioBrick™ standard biological parts. However, BioBrick parts are only standardized in terms of how individual parts are physically assembled into multi-component systems, and most parts remain uncharacterized. Standardized tools, techniques, and units of measurement are needed to facilitate the characterization and reuse of parts by independent researchers across many laboratories. We found that the absolute activity of BioBrick promoters varies across experimental conditions and measurement instruments. We choose one promoter (BBa_J23101) to serve as an in vivo reference standard for promoter activity. We demonstrated that, by measuring the activity of promoters relative to BBa_J23101, we could reduce variation in reported promoter activity due to differences in test conditions and measurement instruments by ~50%. We defined a Relative Promoter Unit (RPU) in order to report promoter characterization data in compatible units and developed a measurement kit so that researchers might more easily adopt RPU as a standard unit for reporting promoter activity. We distributed a set of test promoters to multiple labs and found good agreement in the reported relative activities of promoters so measured. We also characterized the relative activities of a reference collection of BioBrick promoters in order to further support adoption of RPU-based measurement standards. Relative activity measurements based on an in vivoreference standard enables improved measurement of promoter activity given variation in measurement conditions and instruments. Furthermore, these improvements are sufficient to begin to support the measurement of promoter activities across many laboratories. Additional in vivo reference standards for other types of biological functions would seem likely to have similar utility, and could thus improve research on the design, production, and reuse of standard biological parts.

59 BASIC BIOLOGICAL SCIENCES↗

Rapid 18 F-FDG Uptake in Brain of Awake, Behaving Rat and Anesthetized Chicken has Implications for Behavioral PET Studies in Species With High Metabolisms

Brain-behavior studies using 18 F-FDG PET aim to reveal brain regions that become active during behavior. In standard protocols, 18 F-FDG is injected, the behavior is executed during 30–60 min of tracer uptake, and then the animal is anesthetized and scanned. Hence, the uptake of 18 F-FDG is not itself observed and could, in fact, be complete in very little time. This has implications for behavioral studies because uptake is assumed to reflect concurrent behavior. Here, we utilized a new, miniature PET scanner termed RatCAP to measure uptake simultaneously with behavior. We employed a novel injection protocol in which we administered 18 F-FDG (i.v.) four times over two 2 h to allow for repeated measurements and the correlation of changes in uptake and behavioral activity. Furthermore, using standard PET methods, we explored the effects of injection route on uptake time in chickens, a model for avians, for which PET studies are just beginning. We found that in the awake, behaving rat most of the 18 F-FDG uptake occurred within minutes and overlapped to a large extent with 18F-FDG data taken from longer uptake periods. By contrast, behavior which occurred within minutes of the 18 F-FDG infusion differed markedly from the behavior that occurred during later uptake periods. Accordingly, we found that changes in 18 F-FDG uptake in the striatum, motor cortex and cerebellum relative to different reference regions significantly predicted changes in behavioral activity during the scan, if the time bins used for correlation were near the injection times of 18 F-FDG. However, when morphine was also injected during the scan, which completely abolished behavioral activity for over 50 min, a large proportion of the variance in behavioral activity was also explained by the uptake data from the entire scan. In anesthetized chickens, tracer uptake was complete in about 80 min with s.c. injection, but 8 min with i.v. injection. In conclusion, uptake time needs to be taken into account to more accurately correlate PET and behavioral data in mammals and avians. Additionally, RatCAP together with multiple, successive injections of 18 F-FDG may be useful to explore changes in uptake over time in relation to changes in behavior.

Behavioral Sciences↗

Difference distributions applicable to certain health physic's measurements

This paper discusses calculational methods for the determination of the difference distributions associated with certain health physics measurements. These measurements include the check source response counts relative to an initial reference count, the Albatross (i.e., HPI model 2080B) neutron tube counts relative to the gamma tube counts, and those that involve the use of the automatic background subtraction feature within portable health physics instrumentation. This paper therefore provides a technical basis for the necessary source strength of a check source in order to meet daily limits, the gamma field limitations of the HPI2080 Albatross, as well as the consequences of automatic background subtraction. Examples are provided that illustrate the methods for a few specific measurements.

61 RADIATION PROTECTION AND DOSIMETRY↗

Guaranteeing Failsafe Operation of Extended-Scene Shack-Hartmann Wavefront Sensor Algorithm

A Shack-Hartmann sensor (SHS) is an optical instrument consisting of a lenslet array and a camera. It is widely used for wavefront sensing in optical testing and astronomical adaptive optics. The camera is placed at the focal point of the lenslet array and points at a star or any other point source. The image captured is an array of spot images. When the wavefront error at the lenslet array changes, the position of each spot measurably shifts from its original position. Determining the shifts of the spot images from their reference points shows the extent of the wavefront error. An adaptive cross-correlation (ACC) algorithm has been developed to use scenes as well as point sources for wavefront error detection. Qualifying an extended scene image is often not an easy task due to changing conditions in scene content, illumination level, background, Poisson noise, read-out noise, dark current, sampling format, and field of view. The proposed new technique based on ACC algorithm analyzes the effects of these conditions on the performance of the ACC algorithm and determines the viability of an extended scene image. If it is viable, then it can be used for error correction; if it is not, the image fails and will not be further processed. By potentially testing for a wide variety of conditions, the algorithm s accuracy can be virtually guaranteed. In a typical application, the ACC algorithm finds image shifts of more than 500 Shack-Hartmann camera sub-images relative to a reference sub -image or cell when performing one wavefront sensing iteration. In the proposed new technique, a pair of test and reference cells is selected from the same frame, preferably from two well-separated locations. The test cell is shifted by an integer number of pixels, say, for example, from m= -5 to 5 along the x-direction by choosing a different area on the same sub-image, and the shifts are estimated using the ACC algorithm. The same is done in the y-direction. If the resulting shift estimate errors are less than a pre-determined threshold (e.g., 0.03 pixel), the image is accepted. Otherwise, it is rejected.

Sidick, Erikin↗

Impact of hydrogen and oxygen defects on the lattice parameter of chemical vapor deposited zinc sulfide

The lattice parameter of cubic chemical vapor deposited (CVD) ZnS with measured oxygen concentrations < 0.6 at.% and hydrogen impurities of < 0.015 at.% have been measured and found to vary between -0.10% and +0.09% relative to the reference lattice parameter (5.4093 Å) of oxygen-free cubic ZnS as reported in the literature. Defects other than substitutional O must be invoked to explain these observed volume changes. The structure and thermodynamic stability of a wide range of native and impurity induced defects in ZnS have been determined by Ab initio calculations. Lattice contraction is caused by S-vacancies, substitutional O on S sites, Zn vacancies, H in S vacancies, peroxy defects, and dissociated water in S-vacancies. The lattice is expanded by interstitial H, H in Zn vacancies, dihydroxy defects, interstitial oxygen, Zn and [ZnHn] complexes (n=1,…,4), interstitial Zn, and S2 dumbbells. Oxygen, though present, likely forms substitutional defects for sulfur resulting in lattice contraction rather than as interstitial oxygen resulting in lattice expansion. It is concluded based on measurement and calculations that excess zinc atoms either at anti-sites (i.e. Zn atoms on S-sites) or possibly as interstitial Zn are responsible for the relative increase of the lattice parameter of commercially produced CVD ZnS.

ab initio↗

Clustering properties and halo masses for central galaxies in the local universe

We investigate the clustering and dark matter halo mass for a sample of ∼16,000 central galaxies selected from the SDSS/DR7 group catalog. We select subsamples of central galaxies on three two-dimensional planes, each formed by stellar mass (M{sub ∗}) and one other property out of optical color (g − r), surface stellar mass density (μ{sub ∗}), and central stellar velocity dispersion (σ{sub ∗}). For each subsample we measure both the projected cross-correlation function (w{sub p}(r{sub p})) relative to a reference galaxy sample, and an average mass of the host dark matter halos (M{sub h}). Both w{sub p}(r{sub p}) and M{sub h} show the strongest dependence on M{sub ∗}, and there is no clear dependence on the other properties when M{sub ∗} is fixed. This result provides strong support to the previously adopted assumption that, for central galaxies, stellar mass is the best indicator of the host dark halo mass. For comparison we have estimated w{sub p}(r{sub p}) for the full galaxy population and the population of satellite galaxies. Both populations show similar clustering properties in all cases, but they are similar to the centrals only at high masses (M{sub ∗} ≳10{sup 11} M{sub ⊙}). At lower masses, their w{sub p}(r{sub p}) depends more strongly on σ{sub ∗} and g − r than on M{sub ∗}. It is thus necessary to consider central and satellite galaxies separately when studying the link between galaxies and dark matter halos. We discuss the implications of our results for the relative roles of halo mass and galaxy structure in quenching the star formation in central galaxies.

79 ASTRONOMY AND ASTROPHYSICS↗

ZPPR-15 Small Reactivity Worth Experiments

In addition to measuring the worth of sodium voiding and the worth of simulated control rods, the ZPPR staff measured the Doppler worth of four standard samples, the worth of axial expansion and the worth of radial bowing in ZPPR-15. Doppler sample worths were measured in ZPPR-15A, ZPPR-15B and ZPPR-15D. The Doppler samples were natural UO 2 , depleted uranium metal, depleted U-10Zr alloy and 33% enriched UO 2 . These samples were placed in a sample capsule in the inner core of ZPPR-15 and heated to various temperatures between 300 K and 1100 K. The resulting changes in reactivity relative to the reference configuration were measured to determine the Doppler worths of the samples. Special segmented drawers were constructed to measure the worth of axial expansion in ZPPR15. The segments were connected to each other, and the back segment was connected to a spring-loaded cable. Pulling the cable introduced small gaps between drawer segments to simulate axial expansion, and releasing the cable eliminated those gaps. The worth of this simulated axial expansion was measured in ZPPR-15A, ZPPR-15B and ZPPR-15D. The worth of radial bowing was measured in ZPPR-15, but the experimenters regarded the result as unsatisfactory. Radial bowing was measured by two methods in ZPPR-17A, so the ZPPR-17A bowing measurements were analyzed in place of the unpublished ZPPR-15 radial bowing measurement. The first ZPPR-17A measurement consisted of rearranging the plates in 96 core drawers at the core-radial blanket boundary to simulate outward motion of the fuel during bowing. The second ZPPR-17A measurement used a new bowing oscillator to move the core plates a small distance vertically in a special drawer. The published uncertainties for the Doppler worth, axial expansion worth and radial bowing worth measurements are the statistical uncertainties in the measurements. In reality, the published uncertainty for each of these measurements is just one component of the total uncertainty. There are additional uncertainties specific to each measurement and a common uncertainty related to conversion from the natural measurement units, cents, to pcm for calculations. A full uncertainty analysis was performed for each measurement. The significant uncertainties were quantified, and a total uncertainty was determined for each measurement. The ZPPR-15 and ZPPR-17A experimental records were used to create detailed as-built Monte Carlo models of the Doppler worth, axial expansion and radial bowing measurement configurations.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Metrology Camera System Using Two-Color Interferometry

A metrology system that contains no moving parts simultaneously measures the bearings and ranges of multiple reflective targets in its vicinity, enabling determination of the three-dimensional (3D) positions of the targets with submillimeter accuracy. The system combines a direction-measuring metrology camera and an interferometric range-finding subsystem. Because the system is based partly on a prior instrument denoted the Modulation Sideband Technology for Absolute Ranging (MSTAR) sensor and because of its 3D capability, the system is denoted the MSTAR3D. Developed for use in measuring the shape (for the purpose of compensating for distortion) of large structures like radar antennas, it can also be used to measure positions of multiple targets in the course of conventional terrestrial surveying. A diagram of the system is shown in the figure. One of the targets is a reference target having a known, constant distance with respect to the system. The system comprises a laser for generating local and target beams at a carrier frequency; a frequency shifting unit to introduce a frequency shift offset between the target and local beams; a pair of high-speed modulators that apply modulation to the carrier frequency in the local and target beams to produce a series of modulation sidebands, the highspeed modulators having modulation frequencies of FL and FM; a target beam launcher that illuminates the targets with the target beam; optics and a multipixel photodetector; a local beam launcher that launches the local beam towards the multi-pixel photodetector; a mirror for projecting to the optics a portion of the target beam reflected from the targets, the optics being configured to focus the portion of the target beam at the multi-pixel photodetector; and a signal-processing unit connected to the photodetector. The portion of the target beam reflected from the targets produces spots on the multi-pixel photodetector corresponding to the targets, respectively, and the signal-processing unit centroids the spots to determine bearings of the targets, respectively. As the spots oscillate in intensity because they are mixed with the local laser beam that is flood illuminating the focal plane, the phase of oscillation of each spot is measured, the phase of sidebands in the oscillation of each spot being proportional to a distance to the corresponding target relative to the reference target A.

Dubovitsky, Serge↗

“Best” Iterative Coupled-Cluster Triples Model? More Evidence for 3CC

To follow up on the unexpectedly good performance of several coupled-cluster models with approximate inclusion of 3-body clusters we performed a more complete assessment of the 3CC method for accurate computational thermochemistry in the standard HEAT framework. New spin-integrated implementation of the 3CC method applicable to closed- and open-shell systems utilizes a new automated toolchain for derivation, optimization, and evaluation of operator algebra in many-body electronic structure. We found that with a double-ζ basis set the 3CC correlation energies and their atomization energy contributions are almost always more accurate (with respect to the CCSDTQ reference) than the CCSDT model as well as the standard CCSD(T) model. The mean absolute errors in cc-pVDZ {3CC, CCSDT, and CCSD(T)} electronic (per valence electron) and atomization energies relative to the CCSDTQ reference for the HEAT data set, were {24, 70, 122} μE h /e and {0.46, 2.00, 2.58} kJ/mol, respectively. The mean absolute errors in the complete-basis-set limit {3CC, CCSDT, and CCSD(T)} atomization energies relative to the HEAT model reference, were {0.52, 2.00, and 1.07} kJ/mol, The significant and systematic reduction of the error by the 3CC method and its lower cost than CCSDT suggests it as a viable candidate for post- CCSD(T) thermochemistry applications, as well as the preferred alternative to CCSDT in general.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Measurements of Radical Reactivity with an Imine, (CF 3 ) 2 CNH: Rate Constants for Chlorine Atoms and Hydroxyl Radicals and the Global Warming Potential

The rate constant kOH for the reaction of 1,1,1,3,3,3-hexafluoroprop-2-imine with OH radicals was measured relative to two reference compounds, CH 3 F and CH 3 CHF 2 , to be k OH = (4.2 ± 1.1) × 10 −14 cm 3 molecule −1 s −1 at 295 K. This implies an atmospheric lifetime with respect to consumption by OH of 0.75 years. Reaction with Cl atoms yielded k Cl = (7.9 ± 1.7) × 10 −16 cm 3 molecule −1 s −1 at 295 K, and reaction with O 3 has an upper limit of k O3 < 4 × 10 −23 cm 3 molecule −1 s −1 , so that the atmospheric consumption by Cl and O 3 is negligibly slow. Absolute infrared cross sections of the imine yield a radiative efficiency of 0.34 W m −2 ppb −1 , which is corrected to 0.23 W m −2 ppb −1 for the effects of atmospheric lifetime. The imine’s corresponding 100-year global warming potential is 64 ± 19. This value is an upper limit, given that heterogenous atmospheric removal paths, such as hydrolysis in water droplets, are not included.

climate metric↗

SU-E-T-552: Monte Carlo Calculation of Correction Factors for a Free-Air Ionization Chamber in Support of a National Air-Kerma Standard for Electronic Brachytherapy

Purpose: To use Monte Carlo radiation transport methods to calculate correction factors for a free-air ionization chamber in support of a national air-kerma standard for low-energy, miniature x-ray sources used for electronic brachytherapy (eBx). Methods: The NIST is establishing a calibration service for well-type ionization chambers used to characterize the strength of eBx sources prior to clinical use. The calibration approach involves establishing the well-chamber’s response to an eBx source whose air-kerma rate at a 50 cm distance is determined through a primary measurement performed using the Lamperti free-air ionization chamber. However, the free-air chamber measurements of charge or current can only be related to the reference air-kerma standard after applying several corrections, some of which are best determined via Monte Carlo simulation. To this end, a detailed geometric model of the Lamperti chamber was developed in the EGSnrc code based on the engineering drawings of the instrument. The egs-fac user code in EGSnrc was then used to calculate energy-dependent correction factors which account for missing or undesired ionization arising from effects such as: (1) attenuation and scatter of the x-rays in air; (2) primary electrons escaping the charge collection region; (3) lack of charged particle equilibrium; (4) atomic fluorescence and bremsstrahlung radiation. Results: Energy-dependent correction factors were calculated assuming a monoenergetic point source with the photon energy ranging from 2 keV to 60 keV in 2 keV increments. Sufficient photon histories were simulated so that the Monte Carlo statistical uncertainty of the correction factors was less than 0.01%. The correction factors for a specific eBx source will be determined by integrating these tabulated results over its measured x-ray spectrum. Conclusion: The correction factors calculated in this work are important for establishing a national standard for eBx which will help ensure that dose is accurately and consistently delivered to patients.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterizing energy dependence and count rate performance of a dual scintillator fiber-optic detector for computed tomography

Purpose: Kilovoltage (kV) x-rays pose a significant challenge for radiation dosimetry. In the kV energy range, even small differences in material composition can result in significant variations in the absorbed energy between soft tissue and the detector. In addition, the use of electronic systems in light detection has demonstrated measurement losses at high photon fluence rates incident to the detector. This study investigated the feasibility of using a novel dual scintillator detector and whether its response to changes in beam energy from scatter and hardening is readily quantified. The detector incorporates a tissue-equivalent plastic scintillator and a gadolinium oxysulfide scintillator, which has a higher sensitivity to scatter x-rays. Methods: The detector was constructed by coupling two scintillators: (1) small cylindrical plastic scintillator, 500 μm in diameter and 2 mm in length, and (2) 100 micron sheet of gadolinium oxysulfide 500 μm in diameter, each to a 2 m long optical fiber, which acts as a light guide to transmit scintillation photons from the sensitive element to a photomultiplier tube. Count rate linearity data were obtained from a wide range of exposure rates delivered from a radiological x-ray tube by adjusting the tube current. The data were fitted to a nonparalyzable dead time model to characterize the time response. The true counting rate was related to the reference free air dose air rate measured with a 0.6 cm{sup 3} Radcal{sup ®} thimble chamber as described in AAPM Report No. 111. Secondary electron and photon spectra were evaluated using Monte Carlo techniques to analyze ionization quenching and photon energy-absorption characteristics from free-in-air and in phantom measurements. The depth/energy dependence of the detector was characterized using a computed tomography dose index QA phantom consisting of nested adult head and body segments. The phantom provided up to 32 cm of acrylic with a compatible 0.6 cm{sup 3} calibrated ionization chamber to measure the reference air kerma. Results: Each detector exhibited counting losses of 5% when irradiated at a dose rate of 26.3 mGy/s (Gadolinium) and 324.3 mGy/s (plastic). The dead time of the gadolinium oxysulfide detector was determined to be 48 ns, while the dead time of the plastic scintillating detector was unable to accurately be calculated due to poor counting statistics from low detected count rates. Noticeable depth/energy dependence was observed for the plastic scintillator for depths greater than 16 cm of acrylic that was not present for measurements using the gadolinium oxysulfide scintillator, leading us to believe that quenching may play a larger role in the depth dependence of the plastic scintillator than the incident x-ray energy spectrum. When properly corrected for dead time effects, the energy response of the gadolinium oxysulfide scintillator is consistent with the plastic scintillator. Using the integrated dual detector method was superior to each detector individually as the depth-dependent measure of dose was correctable to less than 8% between 100 and 135 kV. Conclusions: The dual scintillator fiber-optic detector accommodates a methodology for energy dependent corrections of the plastic scintillator, improving the overall accuracy of the dosimeter across the range of diagnostic energies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Inertial orientation tracker having automatic drift compensation for tracking human head and other similarly sized body

A self contained sensor apparatus generates a signal that corresponds to at least two of the three orientational aspects of yaw, pitch and roll of a human-scale body, relative to an external reference frame. A sensor generates first sensor signals that correspond to rotational accelerations or rates of the body about certain body axes. The sensor may be mounted to the body. Coupled to the sensor is a signal processor for generating orientation signals relative to the external reference frame that correspond to the angular rate or acceleration signals. The first sensor signals are impervious to interference from electromagnetic, acoustic, optical and mechanical sources. The sensors may be rate sensors. An integrator may integrate the rate signal over time. A drift compensator is coupled to the rate sensors and the integrator. The drift compensator may include a gravitational tilt sensor or a magnetic field sensor or both. A verifier periodically measures the orientation of the body by a means different from the drift sensitive rate sensors. The verifier may take into account characteristic features of human motion, such as stillness periods. The drift compensator may be, in part, a Kalman filter, which may utilize statistical data about human head motion.

Foxlin, Eric M.↗

Inertial orientation tracker apparatus method having automatic drift compensation for tracking human head and other similarly sized body

A self contained sensor apparatus generates a signal that corresponds to at least two of the three orientational aspects of yaw, pitch and roll of a human-scale body, relative to an external reference frame. A sensor generates first sensor signals that correspond to rotational accelerations or rates of the body about certain body axes. The sensor may be mounted to the body. Coupled to the sensor is a signal processor for generating orientation signals relative to the external reference frame that correspond to the angular rate or acceleration signals. The first sensor signals are impervious to interference from electromagnetic, acoustic, optical and mechanical sources. The sensors may be rate sensors. An integrator may integrate the rate signal over time. A drift compensator is coupled to the rate sensors and the integrator. The drift compensator may include a gravitational tilt sensor or a magnetic field sensor or both. A verifier periodically measures the orientation of the body by a means different from the drift sensitive rate sensors. The verifier may take into account characteristic features of human motion, such as stillness periods. The drift compensator may be, in part, a Kalman filter, which may utilize statistical data about human head motion.

Foxlin, Eric M.↗