Search NASA⌕ Search

SEARCH · Search NASA

Results for “Response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Comparison of aortic and carotid baroreflex stimulus-response characteristics in humans

In order to characterize the stimulus-response relationships of the arterial, aortic, and carotid baroreflexes in mediating cardiac chronotropic function, we measured heart rate (HR) responses elicited by acute changes in mean arterial pressure (MAP) and carotid sinus pressure (CSP) in 11 healthy individuals. Arterial (aortic + carotid) baroreflex control of HR was quantified using ramped changes in MAP induced by bolus injection of phenylephrine (PE) and sodium nitroprusside (SN). To assess aortic-cardiac responses, neck pressure (NP) and suction (NS) were applied during PE and SN administration, respectively, to counter alterations in CSP thereby isolating the aortic baroreflex. Graded levels of NP and NS were delivered to the carotid sinus using a customized neck collar device to assess the carotid-cardiac baroreflex, independent of drug infusion. The operating characteristics of each reflex were determined from the logistic function of the elicited HR response to the induced change in MAP. The arterial pressures at which the threshold was located on the stimulus-response curves determined for the arterial, aortic and carotid baroreflexes were not significantly different (72+/-4, 67+/-3, and 72+/-4 mm Hg, respectively, P > 0.05). Similarly, the MAP at which the saturation of the reflex responses were elicited did not differ among the baroreflex arcs examined (98+/-3, 99+/-2, and 102+/-3 mm Hg, respectively). These data suggest that the baroreceptor populations studied operate over the same range of arterial pressures. This finding indicates each baroreflex functions as both an important anti-hypotensive and anti-hypertensive mechanism. In addition, this investigation describes a model of aortic baroreflex function in normal healthy humans, which may prove useful in identifying the origin of baroreflex dysfunction in disease- and training-induced conditions.

Non-NASA Center↗

Time course of vasodilatory responses in skeletal muscle arterioles: role in hyperemia at onset of exercise

At the onset of dynamic exercise, muscle blood flow increases within 1-2 s. It has been postulated that local vasodilatory agents produced by the vascular endothelium or the muscle itself contribute to this response. We hypothesized that only vasodilators that act directly on the vascular smooth muscle could produce vasodilation of skeletal muscle arterioles in <2 s. To test this hypothesis, we determined the time course of the vasodilatory response of isolated skeletal muscle arterioles to direct application of potassium chloride, adenosine, acetylcholine, and sodium nitroprusside. Soleus and gastrocnemius muscles were dissected from the hindlimbs of male Sprague-Dawley rats. First-order arterioles (100-200 microm) were isolated, cannulated on micropipettes, and pressurized to 60 cmH(2)O in an organ bath. Vasodilatory agents were added directly to the bath, and diameter responses of the arterioles were recorded in real time on a videotape recorder. Frame-by-frame analysis of the diameter responses indicated that none of the vasodilator agents tested produced significant diameter increases in <4 s in either soleus or gastrocnemius muscle arterioles. These results indicate that, although these local vasodilators produce significant vasodilation of skeletal muscle resistance arterioles, these responses are not rapid enough (within 1-2 s) to contribute to the initiation of the exercise hyperemic response at the onset of dynamic exercise.

NASA Discipline Musculoskeletal↗

Short-latency primate vestibuloocular responses during translation

Short-lasting, transient head displacements and near target fixation were used to measure the latency and early response gain of vestibularly evoked eye movements during lateral and fore-aft translations in rhesus monkeys. The latency of the horizontal eye movements elicited during lateral motion was 11.9 +/- 5.4 ms. Viewing distance-dependent behavior was seen as early as the beginning of the response profile. For fore-aft motion, latencies were different for forward and backward displacements. Latency averaged 7.1 +/- 9.3 ms during forward motion (same for both eyes) and 12.5 +/- 6.3 ms for the adducting eye (e.g., left eye during right fixation) during backward motion. Latencies during backward motion were significantly longer for the abducting eye (18.9 +/- 9.8 ms). Initial acceleration gains of the two eyes were generally larger than unity but asymmetric. Specifically, gains were consistently larger for abducting than adducting eye movements. The large initial acceleration gains tended to compensate for the response latencies such that the early eye movement response approached, albeit consistently incompletely, that required for maintaining visual acuity during the movement. These short-latency vestibuloocular responses could complement the visually generated optic flow responses that have been shown to exhibit much longer latencies.

Non-NASA Center↗

Horizontal vestibuloocular reflex evoked by high-acceleration rotations in the squirrel monkey. II. Responses after canal plugging

The horizontal angular vestibuloocular reflex (VOR) evoked by high-frequency, high-acceleration rotations was studied in four squirrel monkeys after unilateral plugging of the three semicircular canals. During the period (1-4 days) that animals were kept in darkness after plugging, the gain during steps of acceleration (3, 000 degrees /s(2), peak velocity = 150 degrees /s) was 0.61 +/- 0.14 (mean +/- SD) for contralesional rotations and 0.33 +/- 0.03 for ipsilesional rotations. Within 18-24 h after animals were returned to light, the VOR gain for contralesional rotations increased to 0. 88 +/- 0.05, whereas there was only a slight increase in the gain for ipsilesional rotations to 0.37 +/- 0.07. A symmetrical increase in the gain measured at the plateau of head velocity was noted after animals were returned to light. The latency of the VOR was 8.2 +/- 0. 4 ms for ipsilesional and 7.1 +/- 0.3 ms for contralesional rotations. The VOR evoked by sinusoidal rotations of 0.5-15 Hz, +/-20 degrees /s had no significant half-cycle asymmetries. The recovery of gain for these responses after plugging was greater at lower than at higher frequencies. Responses to rotations at higher velocities for frequencies >/=4 Hz showed an increase in contralesional half-cycle gain, whereas ipsilesional half-cycle gain was unchanged. A residual response that appeared to be canal and not otolith mediated was noted after plugging of all six semicircular canals. This response increased with frequency to reach a gain of 0.23 +/- 0.03 at 15 Hz, resembling that predicted based on a reduction of the dominant time constant of the canal to 32 ms after plugging. A model incorporating linear and nonlinear pathways was used to simulate the data. The coefficients of this model were determined from data in animals with intact vestibular function. Selective increases in the gain for the linear and nonlinear pathways predicted the changes in recovery observed after canal plugging. An increase in gain of the linear pathway accounted for the recovery in VOR gain for both responses at the velocity plateau of the steps of acceleration and for the sinusoidal rotations at lower peak velocities. The increase in gain for contralesional responses to steps of acceleration and sinusoidal rotations at higher frequencies and velocities was due to an increase in the gain of the nonlinear pathway. This pathway was driven into inhibitory cutoff at low velocities and therefore made no contribution for rotations toward the ipsilesional side.

NASA Discipline Developmental Biology↗

Effects of vestibular loss on head stabilization in response to head and body perturbations

Control of head position during postural responses is important to facilitate both the interpretation of vestibular signals and the stabilization of gaze. In these experiments, we compared head stabilization for two different postural tasks: 1) in response to perturbations at the head, and 2) in response to perturbations induced at the support surface, which perturb both body and head position. To determine whether normal vestibular function is necessary for head stabilization in these two tasks, responses to forward and backward mechanical perturbations of the head and body were compared for 13 normal subjects and 4 patients with profound bilateral vestibular loss (two with vestibular loss in adulthood and two in infancy). Normal subjects showed little neck muscle activity for body perturbations, but large, early activations in both neck extensors and flexors for head perturbations. In contrast, vestibular patients showed excessive neck muscle activation for body perturbations and reduced or absent neck muscle activity for head perturbations. Patients with vestibular loss in adulthood also showed increased head acceleration in response to both head and body perturbations, but patients with vestibular loss in infancy showed more normal head accelerations. For body perturbations, the differences in head acceleration between patients and normals were greater for later head acceleration peaks, indicating poor head control during the execution of the postural response. Trunk angle changes were also higher in the patients for forward body perturbations, indicating that poorer control of trunk position could have contributed to their poorer head stabilization. These results indicate that the vestibular system plays an important role in head and trunk stabilization for both head and body perturbations. However, the more normal head accelerations of the patients with infant vestibular loss also indicate that other mechanisms, possibly involving neck reflexes, can at least partially substitute for the vestibular system to provide head and trunk stabilization.

NASA Discipline Neuroscience↗

Transgenic AEQUORIN reveals organ-specific cytosolic Ca2+ responses to anoxia and Arabidopsis thaliana seedlings

Using the transgenic AEQUORIN system, we showed that the cotyledons and leaves of Arabidopsis thaliana seedlings developed a biphasic luminescence response to anoxia, indicating changes in cytosolic Ca2+ levels. A fast and transient luminescence peak occurred within minutes of anoxia, followed by a second, prolonged luminescence response that lasted 1.5 to 4 h. The Ca2+ channel blockers Gd3+, La3+, and ruthenium red (RR) partially inhibited the first response and promoted a larger and earlier second response, suggesting different origins for these responses. Both Gd3+ and RR also partially inhibited anaerobic induction of alcohol dehydrogenase gene expression. However, although anaerobic alcohol dehydrogenase gene induction occurred in seedlings exposed to water-agar medium and in roots, related luminescence responses were absent. Upon return to normoxia, the luminescence of cotyledons, leaves, and roots dropped quickly, before increasing again in a Gd3+, La3+, ethyleneglycol-bis(beta-aminoethyl ether)-N,N'-tetraacetic acid-, and RR-sensitive fashion.

Non-NASA Center↗

Gender differences in endocrine responses to posture and 7 days of -6 degrees head-down bed rest

Endocrine regulation of fluids and electrolytes during 7 days of -6 degrees head-down bed rest (HDBR) was compared in male (n = 8) and, for the first time, female (n = 8) volunteers. The subjects' responses to quiet standing for 2 h before and after HDBR were also tested. In both sexes, diuresis and natriuresis were evident during the first 2-3 days of HDBR, resulting in a marked increase in the urinary Na(+)-to-K+ ratio and significant Na+ retention on re-ambulation. After the 1st day of HDBR, plasma renin activity (PRA) was increased relative to aldosterone (Aldo), plasma volume was decreased, and the renal response to Aldo appeared to be appropriate. Circulating levels of arginine vasopressin, cortisol, and ACTH were unchanged during HDBR. Plasma testosterone decreased slightly on day 2 of HDBR in males. The ratio of early morning ACTH to cortisol was lower in females than in males because ACTH was lower in females. Urinary cortisol increased and remained elevated throughout the HDBR in males only. There were no gender differences in the responses to 7 days of HDBR, except those in the pituitary-adrenal system; those differences appeared unrelated to the postural change. The provocative cardiovascular test of quiet standing before and after HDBR revealed both sex differences and effects of HDBR. There were significant sex differences in cardiovascular responses to standing before and after HDBR. Females had greater PRA and Aldo responses to standing before HDBR and larger Aldo responses to standing after HDBR than males.(ABSTRACT TRUNCATED AT 250 WORDS).

NASA Discipline Number 14-10↗

Vestibular short latency responses to pulsed linear acceleration in unanesthetized animals

Linear acceleration transients were used to elicit vestibular compound action potentials in non-invasively prepared, unanesthetized animals for the first time (chicks, Gallus domesticus, n = 33). Responses were composed of a series of up to 8 dominant peaks occurring within 8 msec of the stimulus. Response amplitudes for 1.0 g stimulus ranged from 1 to 10 microV. A late, slow, triphasic, anesthesia-labile component was identified as a dominant response feature in unanesthetized animals. Amplitudes increased and latencies decreased as stimulus intensity was increased (MANOVA P less than 0.05). Linear regression slope ranges were: amplitudes = 1.0-5.0 microV/g; latencies = -300 to -1100 microseconds/g. Thresholds for single polarity stimuli (0.035 +/- 0.022 g, n = 11) were significantly lower than those of alternating polarity (0.074 +/- 0.028 g, n = 18, P less than 0.001). Bilateral labyrinthectomy eliminated responses whereas bilateral extirpation of cochleae did not significantly change response thresholds. Intense acoustic masking (100/104 dB SL) produced no effect in 2 animals, but did produce small to moderate effects on response amplitudes in 7 others. Changes were attributed to effects on vestibular end organs. Results of unilateral labyrinth blockade (tetrodotoxin) suggest that P1 and N1 preferentially reflect ipsilateral eighth nerve compound action potentials whereas components beyond approximately 2 msec reflect activity from vestibular neurons that depend on both labyrinths. The results demonstrate that short latency vestibular compound action potentials can be measured in unanesthetized, non-invasively prepared animals.

NASA Discipline Neuroscience↗

Prolonged lobar hypoxia in vivo enhances the responsivity of isolated pulmonary veins to hypoxia

The hypoxic response of pulmonary vessels isolated from eight sheep whose right apical lobes (RAL) had inspired 100% N2 for 20 h was studied. The RAL of these conscious sheep inspired hypoxic gas and the remainder of the lung inspired air. During hypoxia, RAL perfusion was 33 +/- 3% of its air value, carotid arterial PO2 averaged 86 +/- 3 mm Hg and pulmonary perfusion pressure was not significantly different from the initial control period when the RAL inspired air. At the end of the hypoxic exposure, the sheep were killed, and pulmonary artery and vein rings (0.5 to 2 mm inner diameter) were isolated from both the RAL and the right cardiac lobe, which served as the control lobe (CL). Arteries from the RAL and CL did not contract in response to 6% O2/6% CO2/88% N2 (hypoxia). In contrast, RAL veins did contract vigorously in response to hypoxia, whereas CL veins did not contract or contracted only minimally. Rubbing of the endothelium or prior incubation of RAL veins with catalase (1,200 units/ml), indomethacin (10(-5) M), or the thromboxane A2/prostaglandin H2 (TxA2/PGH2) receptor antagonist, SQ 29,548 (3 X 10(-6) M) each significantly reduced the response to hypoxia. RAL veins were also found to be more reactive than CL veins to the prostaglandin endoperoxide analogue U46619. We conclude that prolonged lobar hypoxia in vivo increases the responsivity of isolated pulmonary veins to hypoxia. These contractions may result from an increase in reactive O2 species, which in turn modify production of, metabolism of, and/or tissue responsivity to TxA2/PGH2.

NASA Discipline Cardiopulmonary↗

The Effect of Tip Geometry on Active-Twist Rotor Response

A parametric examination of the effect of tip geometry on active-twist rotor system response is conducted. Tip geometry parameters considered include sweep, taper, anhedral, nonlinear twist, and the associated radial initiation location for each of these variables. A detailed study of the individual effect of each parameter on active-twist response is presented, and an assessment offered of the effect of combining multiple tip shape parameters. Tip sweep is shown to have the greatest affect on active-twist response, significantly decreasing the response available. Tip taper and anhedral are shown to increase moderately the active-twist response, while nonlinear twist is shown to have a minimal effect. A candidate tip shape that provides active-twist response equivalent to or greater than a rectangular planform blade is presented.

Wilbur, Matthew L.↗

Hypovolemia Induced Orthostatic Hypotension in Presyncopal Astronauts and Normal Subjects Relates to Hypo-Sympathetic Responsiveness

Circulating blood volume is reduced during spaceflight, leaving astronauts hemodynamically compromised after landing. Because of this hypovolemia, crew members are able to withstand a postflight 10 minute upright tilt test only if they are able to mount a hyper-sympathetic response. Previous work from this laboratory has shown that about 30% of astronauts, primarily female, have postflight sympathetic responses to tilt that are equal to or less than their preflight responses and thus, they become presyncopal. Part of the mission of the cardiovascular lab at the Johnson Space Center is to identify susceptible crewmembers before flight so that individualized countermeasures can be prescribed. The goal of this study was to develop a ground based model of hypovolemia that could be used for this purpose We tested the hypothesis that hypovolemia alone, in the absence of spaceflight, would reproduce the landing day rate of presyncope during upright tilt in normal volunteers. Further, we hypothesized that, during hypovolemia, subjects who had sympathetic responses that were equal to or less than their normovolemic responses would become presyncopal during upright tilt tests. We studied 20 subjects, 13 male and 7 female, on two separate occasions: during normovolemia and hypovolemia. We induced hypovolemia with intravenous furosemide 40 hours prior to the experiment day, followed by a 10MEq Na diet. On the normovolemia and hypovolemia test days, plasma volume, tilt tolerance and supine and standing arterial pressure, heart rate and plasma norepinephrine levels were measured. A two factor, repeated measures analysis of variance was performed to examine the differences between group (presyncopal vs. non-presyncopal) and day (normovolemia vs. hypovolemia) effects. There were no differences in baseline arterial pressure between normovolemia and hypovolemia or between presyncopal and non-presyncopal groups, but heart rates were higher with hypovolemia in both groups (presyncopal: 70 5 bpm vs. 63 3 bpm, P = 0.003, non-presyncopal: 59 2 bpm vs. 52 2 bpm, P = 0.003). Similar to patterns reported after flight, non-presyncopal subjects had greater norepinephrine responses to tilt during hypovolemia compared to normovolemia (580 79 vs. 298 37 pg/ml, P < 0.05), but presyncopal subjects did not (180 44 vs. 145 32 pg/ml, P = NS). This new model has the potential to accelerate the development of countermeasures and save flight resources. It can be used to identify astronauts who will become presyncopal on landing day, so that prospective, individualized countermeasures can be developed. In addition, it can also be used to screen candidate countermeasures prior to requests for bed rest or inflight resources.

Meck, Janice V.↗

WISE-2005: Adrenergic Responses Before and After 60 Days of 6 Degree Head-Down Bed-Rest in Women

Sixteen women who participated in the WISE-2005 headdown bed rest (HDBR) were studied before and on day 56 of bed rest to test the hypothesis that chronic changes in circulating norepinephrine (NOR) would change the response to adrenergic receptor agonists. Five minute infusions of 2 doses of isoproterenol (ISO), and 2 doses of NOR were administered while heart rate (HR), mean arterial pressure (MAP) and total peripheral resistance (TPR) were measured. Before HDBR, the higher dose of ISO increased HR by 13 beats/min (P<O.OOl) and decreased TPR by -50% (P<O.OOl) with no changes in MAP, the higher dose of NOR increased MAP by 8 mmHg (P<O.OOl) and increased TPR -20% (P=0.007) with no change in HR. On HDBR day 56, subjects who took part in daily exercise+lower body negative pressure (EX+LBNP) countermeasures had no change in HR response to ISO while the control group (CON) had greater increases in HR. MAP tended to be lower post-HDBR in CON but not in EX+LBNP, while TPR was higher in both groups. In response to NOR, MAP increased with elevated TPR with no change in HR. Post-HDBR TPR increased more in the EX+LBNP group. These studies indicate that HDBR alters the HR response to IS0 but that EX+LBNP countermeasure prevented this change. The greater TPR response to NOR in the post-HDBR for the EX+LBNP group might reflect enhanced peripheral vasoconstrictor response that could reduce the risk of orthostatic intolerance after this countermeasure.

Edgell, H.↗

Magnetic Field Response Measurement Acquisition System

This paper presents a measurement acquisition method that alleviates many shortcomings of traditional measurement systems. The shortcomings are a finite number of measurement channels, weight penalty associated with measurements, electrical arcing, wire degradations due to wear or chemical decay and the logistics needed to add new sensors. Wire degradation has resulted in aircraft fatalities and critical space launches being delayed. The key to this method is the use of sensors designed as passive inductor-capacitor circuits that produce magnetic field responses. The response attributes correspond to states of physical properties for which the sensors measure. Power is wirelessly provided to the sensing element by using Faraday induction. A radio frequency antenna produces a time-varying magnetic field used to power the sensor and receive the magnetic field response of the sensor. An interrogation system for discerning changes in the sensor response frequency, resistance and amplitude has been developed and is presented herein. Multiple sensors can be interrogated using this method. The method eliminates the need for a data acquisition channel dedicated to each sensor. The method does not require the sensors to be near the acquisition hardware. Methods of developing magnetic field response sensors and the influence of key parameters on measurement acquisition are discussed. Examples of magnetic field response sensors and the respective measurement characterizations are presented. Implementation of this method on an aerospace system is discussed.

Woodard, Stanley E.↗

Investigating Response from Turbulent Boundary Layer Excitations on a Real Launch Vehicle using SEA

Statistical Energy Analysis (SEA) response has been fairly well anchored to test observations for Diffuse Acoustic Field (DAF) loading by others. Meanwhile, not many examples can be found in the literature anchoring the SEA vehicle panel response results to Turbulent Boundary Layer (TBL) fluctuating pressure excitations. This deficiency is especially true for supersonic trajectories such as those required by this nation s launch vehicles. Space Shuttle response and excitation data recorded from vehicle flight measurements during the development flights were used in a trial to assess the capability of the SEA tool to predict similar responses. Various known/measured inputs were used. These were supplemented with a range of assumed values in order to cover unknown parameters of the flight. This comparison is presented as "Part A" of the study. A secondary, but perhaps more important, objective is to provide more clarity concerning the accuracy and conservatism that can be expected from response estimates of TBL-excited vehicle models in SEA (Part B). What range of parameters must be included in such an analysis in order to land on the conservative side in response predictions? What is the sensitivity of changes in these input parameters on the results? The TBL fluid structure loading model used for this study is provided by the SEA module of the commercial code VA One.

Harrison, Phillip↗

Advanced Response Surface Modeling of Ares I Roll Control Jet Aerodynamic Interactions

The Ares I rocket uses roll control jets. These jets have aerodynamic implications as they impinge on the surface and protuberances of the vehicle. The jet interaction on the body can cause an amplification or a reduction of the rolling moment produced by the jet itself, either increasing the jet effectiveness or creating an adverse effect. A design of experiments test was planned and carried out using computation fluid dynamics, and a subsequent response surface analysis ensued on the available data to characterize the jet interaction across the ascent portion of the Ares I flight envelope. Four response surface schemes were compared including a single response surface covering the entire design space, separate sector responses that did not overlap, continuously overlapping surfaces, and recursive weighted response surfaces. These surfaces were evaluated on traditional statistical metrics as well as visual inspection. Validation of the recursive weighted response surface was performed using additionally available data at off-design point locations.

Favaregh, Noah M.↗

Spaceflight Did Not Impair Cardiovascular Responses to Upright Posture in an Elderly Astronaut

Some of the cardiovascular changes associated with spaceflight have similarities to those associated with aging. We studied the neuroendocrine and hemodynamic responses to upright posture in a 77 year old astronaut before and after spaceflight and compared them to those of a group of 20 younger (41 plus or minus 1 years) astronauts. While arterial pressure responses to standing were similar between the young and old astronauts, hemodynamic profiles were quite different. The elderly astronaut achieved adequate standing arterial pressure primarily by maintaining stroke volume and thus cardiac output. In spite of very high norepinephrine release, he had very little increase in heart rate or total peripheral resistance. This pattern persisted on all test occasions. These responses suggest high sympathetic responses, down-regulated adrenergic receptors and decreased venous compliance typical of aging. In contrast, younger astronauts did not maintain stroke volume or cardiac output with standing, but had significant increases in heart rate and resistance. These results suggest that this elderly subject had cardiovascular responses to standing that are expected in an aged person. These responses were not deleteriously affected by spaceflight. We suggest that healthy, fit elderly individuals are able to withstand the stresses of extreme environments and are not necessarily limited in their activities simply due to their chronological age.

Rossum, Alfred C.↗

Improvements to a Response Surface Thermal Model for Orion Mated to the International Space Station

This study is an extension of previous work to evaluate the applicability of Design of Experiments (DOE)/Response Surface Methodology to on-orbit thermal analysis. The goal was to determine if the methodology could produce a Response Surface Equation (RSE) that predicted the thermal model temperature results within +/-10 F. An RSE is a polynomial expression that can then be used to predict temperatures for a defined range of factor combinations. Based on suggestions received from the previous work, this study used a model with simpler geometry, considered polynomials up to fifth order, and evaluated orbital temperature variations to establish a minimum and maximum temperature for each component. A simplified Outer Mold Line (OML) thermal model of the Orion spacecraft was used in this study. The factors chosen were the vehicle's Yaw, Pitch, and Roll (defining the on-orbit attitude), the Beta angle (restricted to positive beta angles from 0 to 75), and the environmental constants (varying from cold to hot). All factors were normalized from their native ranges to a non-dimensional range from -1.0 to 1.0. Twenty-three components from the OML were chosen and the minimum and maximum orbital temperatures were calculated for each to produce forty-six responses for the DOE model. A customized DOE case matrix of 145 analysis cases was developed which used analysis points at the factor corners, mid-points, and center. From this data set, RSE s were developed which consisted of cubic, quartic, and fifth order polynomials. The results presented are for the fifth order RSE. The RSE results were then evaluated for agreement with the analytical model predictions to produce a +/-3(sigma) error band. Forty of the 46 responses had a +/-3(sigma) value of 10 F or less. Encouraged by this initial success, two additional sets of verification cases were selected. One contained 20 cases, the other 50 cases. These cases were evaluated both with the fifth order RSE and with the analytical model. For the maximum temperature predictions, 12 of the 23 components had all predictions within +/-10 F and 17 were within +/-20 F. For the minimum temperature predictions, only 4 of the 23 components (the four radiator temperatures), were within the 10 F goal. The maximum temperature RSEs were then run through 59,049 screening cases. The RSE predictions were then filtered to find 55 cases that produced the hottest temperatures. These 55 cases were then analyzed using the thermal model and the results compared against the RSE predictions. As noted earlier, 12 of the 23 responses were within +/-10 F at 17 within +/-20 F. These results demonstrate that if properly formulated, an RSE can provide a reliable, fast temperature prediction. Despite this progress, additional work is needed to determine why the minimum temperatures responses and 6 of the hot temperature responses did not produce reliable RSEs. Recommend focus areas are the model itself (arithmetic vs. diffusion nodes) and seeking consultations with statistical application experts.

Miller, StephenW.↗

Altered Innate and Lymphocytic Immune Responses in Mouse Splenocytes Post-Flight

Space flight is known to affect immune responses of astronauts and animals, decreasing lymphocytic responses to mitogenic stimuli, delayed typed hypersensitivity reactions, and T-cell activation. Despite changes in immune suppression, there are no reports of consistent adverse clinical events post flight. To further investigate the spectrum of affected immune responses, murine splenocytes were stimulated immediately post-shuttle flight (14 days on STS-135) with T-cell stimulators or toll-like receptor agonists. Comparisons were made to ground control splenocytes from age-matched mice. Cell phenotypes were assessed, as well as activation markers and associated cytokine production. The CD4+ population decreased with no concurrent decrease in CD8+ cells from shuttle mice post flight compared to ground controls. Regarding antigen presenting cell populations, the number of CD11c+ cells were slightly elevated post flight, compared to ground controls, with increased MHC Class I expression (I-A(sup b)) and no change in Class II expression (H-2K(sup b)). CD86+ populations were also significantly diminished. However, the decreased markers did not correlate with activity. Stimulation of splenocytes post flight showed significant increase in bead uptake, increased Class I expression, increased TNF-alpha and IL-6 production in response to TLR-2 (zymosan) and TLR-4 (LPS) agonists. While most activated (ConA or anti-CD3/anti-CD28) CD4+ cells showed markedly diminished responses (reduced IL-2 production), non-specific T cell responses to superantigen (SEA/SEB) increased post flight as determined by expression of early activation markers. Production of additional cytokines was also dysregulated postflight. Overall, persistent immune changes during space flight could represent unique clinical risks for exploration class missions. The consequences of pathogenic encounter remain an important concern that should be addressed.

Hwang, ShenAn↗