Search NASA⌕ Search

SEARCH · Search NASA

Results for “SCINTILLATION COUNTING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Real-time neutron multiplicity and source localization for criticality safety during fuel debris removal

Advancing neutron detection and analysis techniques for complex radiation environments is an ongoing focus in nuclear instrumentation and monitoring. This proposal presents research and development of a generalized real-time neutron monitoring and analysis system, applicable to any detector capable of producing time-tagged neutron count data. While the work is demonstrated using the Neutron Multiplication Analysis Detector (NoMAD), a modular 15-tube helium-3 (He-3) array, due to its availability, spatial resolution, and flexible deployment, the methods developed are extensible to other systems, including organic scintillators and fast digital detectors. This research investigates two complementary analytical techniques for real-time characterization of neutron emitting sources: neutron multiplicity estimation based on the Hage-Cifarelli formalism and spatial localization using supervised machine learning applied to spatial count rate patterns. These methods are designed to operate under dynamic, evolving conditions such as fuel debris retrieval or reactor startup, where neutron-emitting material geometries may be partially unknown or changing over time. By integrating statistical neutron emission data with spatial localization, this research aims to develop and evaluate methods for real time neutron monitoring, source characterization, and material verification. Key contributions include implementation of a low-latency data pipeline for continuous neutron multiplicity analysis, development and validation of machine learning models for spatial inference, and experimental evaluation of system performance under variable measurement conditions. The outcomes are intended to support applications in nuclear safeguards, verification, emergency response, and reactor startup.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improved light yield and growth of large-volume ultrafast single crystal scintillators Cs 2 ZnCl 4 and Cs 3 ZnCl 5

Due to their reported fast decay times, Cs 2 ZnCl 4 and Cs 3 ZnCl 5 are promising candidates for detection of gamma rays and X-rays in high count rate and fast timing applications. In this work, we show that single crystals with better optical quality than previously demonstrated – and larger in size – can be grown via the vertical Bridgman method. Highly transparent Ø7 mm crystals of undoped Cs 2 ZnCl 4 and Cs 3 ZnCl 5 are grown and measured to have light yields surpassing those previously reported, achieving 1980 ± 100 ph/MeV and 1460 ± 70 ph/MeV at 662 keV – a 55% and 232% improvement, respectively. We observe single-component scintillation decay times for both Cs 2 ZnCl 4 (1.66 ns) and Cs 3 ZnCl 5 (0.82 ns) and radioluminescence emission with maximum intensity at ~290 nm. Scalability of these materials is also evaluated based on growth of Ø22 mm crystals. Minimal cracking is observed, and the fast decay times are maintained at this size. Coincidence time resolution of 3 × 3 × 5 mm 3 and 7 × 7 × 10 mm 3 pixels cut from Ø22 mm Cs 2 ZnCl 4 are measured to be 148 ± 1 ps FWHM and 175 ± 1 ps FWHM, respectively. Here, the improved performance and ability to be fabricated in large sizes now place Cs 2 ZnCl 4 and Cs 3 ZnCl 5 on the map as potential contenders for radiation detection applications where BaF 2 – the most commonly used ultrafast inorganic scintillator – is typically considered.

36 MATERIALS SCIENCE↗

Development of a Phoswich Neutron Detector with Energy Spectroscopy Capability

Neutron measurement technology is critical to the detection and identification of nuclear materials and sources. Portable neutron detectors that enable thermal neutron and fast neutron measurements with a single system are still an experimental area. The ability to employ three signatures (photons, thermal neutrons, and fast neutrons) simultaneously for identification provides an extra element of certainty in results. The energy of fast neutrons can also provide a unique spectral signature for source quantification. A phoswich detector is based on the use of two dissimilar scintillators with a single photomultiplier tube (PMT) for the purpose of radiation detection. Past development was focused primarily on the application of the multi-scintillator design to gamma-ray, alpha- and beta-particle measurements. To this end, the work presented here has focused on the development of a phosphor sandwich ('phoswich') detector capable of differentiating between photons, thermal neutrons, and fast neutrons. The portable phoswich neutron detector was designed using two solid-sate scintillators: the {sup 6}Li-loaded glass and the EJ-299-33A plastic. Experiments showed that detector provides simultaneously count rates of photons, thermal neutrons, and fast neutrons with the energy spectroscopy option. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An event-triggered coincidence algorithm for fast-neutron multiplicity assay corrected for cross-talk and photon breakthrough

Here, a model quantifying detector cross-talk and the misidentification of events in fast neutron coincidence distributions is described. This is demonstrated for two experimental arrangements comprising rings of 8 and 15 organic liquid scintillation detectors. Correction terms developed as part of this model are tested with 252 Cf and a relationship is developed between the 235 U enrichment of U 3 O 8 and the order of correlated, fast neutron multiplets induced by an americium–lithium source. The model is also supported by Geant4 simulations. The results suggest that a typical assay, for experimental arrangements that are similar to the examples investigated in this research, will exhibit cross-talk for less than 1% of all detected fast neutrons but, if not accounted for, this can bias the numerical analysis by a margin of 10% and 35% in second- and third-order coincidences (i.e. couplet and triplet counts), respectively. Further, for the case of 252 Cf, it is shown that a relatively low proportion of 4% breakthrough by rays (that is, photons misidentified as neutrons by the pulse-shape discrimination process) can lead to an erroneous increase of 20% in total neutron counts in the assay of a mixed-field, in this case of 252 Cf. These findings will help direct the developments needed to enable organic scintillation detectors with pulse shape discriminators to be applied reliably to nuclear safeguards and non-proliferation verification tasks.

42 ENGINEERING↗

{sup 6}LiF:ZnS(Ag) Neutrons Scintillator Detector Configuration for Optimal Readout

A Chromatic Analysis Neutron Diffractometer Or Reflectometer (CANDOR) is under development at the NIST Center for Neutron Research (NCNR). The CANDOR neutron sensor will rely on scintillator material for detecting the neutrons scattered by the sample under test. It consists of {sup 6}LiF:ZnS(Ag) scintillator material into which wavelength shifting (WLS) fibers have been embedded. Solid state photo-sensors (silicon photomultipliers) coupled to the WLS fibers are used to detect the light produced by the neutron capture event ({sup 6}Li (n,α) {sup 3}H reaction) and ionization of the ZnS(Ag). This detector configuration has the potential to accomplish the CANDOR performance requirements for efficiency of 90% for 5 A (3.35 meV) neutrons with high gamma rejection (10{sup 7}) along with compact design, affordable cost and materials availability. However this novel design includes challenges for precise neutron detection. The recognizing of the neutron signature versus the noise event produce by gamma event cannot be easy overcome by pulse height discrimination obstacle as can be achieved with {sup 3}He gas tube. Furthermore the selection of silicon photomultipliers (SiPM) as the light sensor maintains the obstacle of dark noise that does not exist when a photomultiplier tube is coupled to the scintillator. A proper selection of SiPM should focus on increasing the output signal and reducing the dark noise in order to optimize the detection sensitivity and to provide a clean signal pulse shape discrimination. The main parameters for evaluation are: - Quantum Efficiency (QE) - matching the SiPM peak QE with the peak transmission wavelength emission of the WLS. - Recovery time - a short recovery time is preferred to minimize the pulse width beyond the intrinsic decay time of the scintillator crystal (improves the gamma rejection based output pulse shape (time)). - Diode dimensions -The dark noise is proportional to the diode active area while the signal is provided by the WLS fibers; therefore the diode area should ideally be only minimally larger than fiber bundle area. - Low dark noise - it is desirable to minimize the dark noise during the pulse integration period so as to minimize the background for pulse shape discrimination. - Photon Detection Efficiency - it is desirable to increase the SiPM PDE in order to enhance light collection. This will increase the likelihood of detecting neutron events with lower light production and will present a cleaner raw signal for pulse shape discrimination. We will present the SiPM optimization process and studies of dark noise and gamma and neutron sensitivity as a function of bias voltage and operating temperature that have enabled us to optimize the detector sensitivity and gamma rejection. The gamma rejection performance goal requires to overcome the challenge of discriminating between the light signature accepted by neutron event to the one received by the noise. In addition there is a huge variation between the number of light photons that reaching the WLS fibers for different neutron events caused by the heavy ions energy losses prior to ionizing the ZnS(Ag) and the high light attenuation of the scintillation mixture. This variation in the light signal along with the long decay time of the ZnS(Ag) (tens of microseconds) can cause double counting of the same neutron event in the case of high light output signature or preventing the detection of low sequential light output signature neutron event. We will presents the algorithm developed for {sup 6}LiF:ZnS(Ag) sensor readout and the results achieved by an off-line analysis by Matlab software code that successfully achieved both the high gamma rejection with a sensitive and accurate neutron event detection. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of the filter method for neutron pulse-height distributions measured with organic scintillators

Identification of neutron sources is of interest in several fields, such as homeland security or basic nu-clear physics. Organic scintillators offer the possibility to unfold fast-neutron energy spectra. Since organic scintillators are sensitive to neutrons and gamma-rays, a method to discriminate these two types of particles is required. This paper is focused on investigation of the discrimination properties of the filter method by using a new procedure. We compare the results of an experimental filter method to a digital pulse-shape discrimination (PSD) method based on charge integration. In addition, these methods are compared to the simulation results obtained with the MCNPX-PoliMi code. The experimental and nu-merical investigations were performed with a 252Cf spontaneous-fission neutron source. The integration of the number of counts gave the relative differences between the experimental filter and digital PSD neutron pulse-height distributions (PHDs) and simulated PHDs less than approximately 5% in the range between 60 keVee and 1.715 MeVee of light output. Above 1.715 MeVee, the PSD method has advantages over the filter method, due to the filter method having significantly worse counting statistics. The results show that the filter method has potential for robust neutron measurements when the PSD method cannot be applied, such as for ‘old’ organic plastic scintillators without PSD capability.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Proton-induced radioactivity in NaI (Tl) scintillation detectors

Radioactivity induced by protons in sodium iodide scintillation crystals were calculated and directly measured. These data are useful in determining trapped radiation and cosmic-ray induced, background-counting rates in spaceborne detectors.

Fishman, G. J.↗

Testing of the KRI-developed Silicon PIN Radioxenon Detector

Radioxenon detectors are used for the verification of the Comprehensive Nuclear-Test-Ban Treaty (CTBT) in a network of detectors throughout the world called the International Monitoring System (IMS). The Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO) Provisional Technical Secretariat (PTS) has tasked Pacific Northwest National Laboratory (PNNL) with testing a V.G. Khlopin Radium Institute (KRI) and Lares Ltd-developed Silicon PIN detector for radioxenon detection. PNNL measured radioxenon with the silicon PIN detector and determined its potential compared to current plastic scintillator beta cells. While the PNNL tested Si detector experienced noise issues, a second detector was tested in Russia at Lares Ltd, which did not exhibit the noise issues. Without the noise issues, the Si detector produces much better energy resolution and isomer peak separation than a conventional plastic scintillator cell used in the SAUNA systems in the IMS. Under the assumption of 1 cm 3 of Xe in laboratory-like conditions, 24-hr count time (12-hr count time for the SAUNA), with the respective shielding the minimum detectable concentrations for the Si detector tested by Lares Ltd (and a conventional SAUNA system) were calculated to be: 131m Xe – 0.12 mBq/m 3 (0.12 mBq/m 3 ); 133 Xe – 0.18 mBq/m 3 (0.21 mBq/m 3 ); 133m Xe – 0.07 mBq/m 3 (0.15 mBq/m 3 ); 135 Xe – 0.45 mBq/m 3 (0.67 mBq/m 3 ). Detection limits, which are one of the important factors in choosing the best detection technique for radioxenon in field conditions, are significantly better than for SAUNA-like detection systems for 131m Xe and 133m Xe, but similar for 133 Xe and 135 Xe. Another important factor is the amount of “memory effect” or carry over signal from one radioxenon measurement to the subsequent sample. The memory effect is reduced by a factor of 10 in the Si PIN detector compared to the current plastic scintillator cells. There is potential for further reduction with the removal of plastics within the cell, which will need to be explored in future work. A third important parameter in choosing the best detection technique for radioxenon is the resolution of the electron detection. While the resolution is important in determining the minimum detectable concentration, it plays a larger role in source identification when there is a visible signal. The Silicon PIN diodes generated improved resolution over a similar plastic scintillator cell. With the improved resolution, it becomes easier to distinguish the radioxenon isomers ( 133m Xe and 131m Xe) from the 133 Xe beta continuum background. With the beta background from 133 Xe ever present with the detection of the isomers, the improved resolution proves vital in calculating the ratios of the three isotopes. With an accurate measurement of the isotopic ratios, the anthropogenic sources of radioxenon (medical isotope production and nuclear reactors) can be more accurately distinguished. Based on the results shown within this report, a Si PIN beta cell shows the potential to aid in the operation and discriminating power of the IMS for the CTBTO. However, there are a number of issues that need attention before a detector of this design would be reliable enough for field operations in the IMS. Issues that need develop include, but are not limited to: studying the robustness of the design in field conditions, eliminating or minimizing the noise and variability of individual Si detector elements, understanding the long-term gain stability of the Si detectors, and reducing the non-Si materials within the cell (i.e. the plastic housing).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DANCEing with the Stars: Measuring Neutron Capture on Unstable Isotopes with DANCE

Isotopes heavier than iron are known to be produced in stars through neutron capture processes. Two major processes, the slow (s) and rapid (r) processes are each responsible for 50% of the abundances of the heavy isotopes. The neutron capture cross sections of the isotopes on the s process path reveal information about the expected abundances of the elements as well as stellar conditions and dynamics. Until recently, measurements on unstable isotopes, which are most important for determining stellar temperatures and reaction flow, have not been experimentally feasible. The Detector for Advance Neutron Capture Experiments (DANCE) located at the Los Alamos Neutron Science Center (LANSCE) was designed to perform time-of-flight neutron capture measurements on unstable isotopes for nuclear astrophysics, stockpile stewardship, and reactor development. DANCE is a 4-{pi}BaF{sub 2} scintillator array which can perform measurements on sub-milligram samples of isotopes with half-lives as short as a few hundred days. These cross sections are critical for advancing our understanding of the production of the heavy isotopes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The quick and ultrasensitive determination of K in NaI using inductively coupled plasma mass spectrometry

A highly sensitive, novel and quick assay method utilizing inductively coupled plasma mass spectrometry was developed for the determination of K in NaI powders and NaI(Tl) scintillator crystals for use in ultralow background applications. The determination of K (viz. 40K), as well as Th and U and their daughters, is important in ultralow background detector materials to ensure incorporation of materials of sufficiently high radiopurity. Through the use of improved instrumentation, cool plasma operating conditions, and meticulously clean sample preparations, detection limits of 11 fg natK∙g-1 (or 341 pBq 40K∙kg-1) was attained for K in pure water. Detection limits in the sample matrix (i.e., NaI) were 0.529 ng natK∙g NaI-1 (or 16.4 Bq 40K∙kg NaI -1). A number of different precursor NaI powder samples and NaI(Tl) scintillator crystals were assayed for their K content. Determinations ranged from 0.757 – 31.4 ng natK∙g NaI-1. This method allows for the screening of materials to unprecedented levels in a fraction of the time compared to gamma counting techniques, providing a useful method for a more effective screening tool of K in ultralow background detector materials.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Design, Construction, and Initial Characterization of an Ultra-Low-Background Gas-Proportional Counting System

ABSTRACT Over the past several years, the Pacific Northwest National Laboratory (PNNL) has developed an ultra-low background proportional counter (ULBPC) technology. The resulting detector is the product of an effort to produce a low-background, physically robust gas proportional counter for applications like radon emanation measurements, groundwater tritium, and 37Ar. In order to fully take advantage of the inherent low-background properties designed into the ULBPC, a comparably low-background dedicated counting system is required. An ultra-low-background counting system (ULBCS) was recently built in the new shallow underground laboratory at PNNL. With a design depth of 30 meters water-equivalent, the shallow underground laboratory provides approximately 100x fewer fast neutrons and 6x fewer muons than a surface location. The ULBCS itself provides additional shielding in the form of active anti-cosmic veto (via 2-in. thick plastic scintillator paddles) and passive borated poly (1 in.), lead (6 in.), and copper (~3 in.) shielding. This work will provide details on PNNL’s new shallow underground laboratory, examine the motivation for the design of the counting system, and provide results from the characterization of the ULBCS, including initial detector background.

ultra-low-background, proportional counters, shall↗

Effect of natural gamma background radiation on portal monitor radioisotope unmixing

It is well known that national security relies on several layers of protection. One of the most important is the traffic control at borders and ports that exploits Radiation Portal Monitors (RPMs) to detect and deter potential smuggling attempts. Most portal monitors rely on plastic scintillators to detect gamma rays. Despite their poor energy resolution, their cost effectiveness and the possibility of growing them in large sizes make them the gamma-ray detector of choice in RPMs. Unmixing algorithms applied to organic scintillator spectra can be used to reliably identify the bare and unshielded radionuclides that triggered an alarm, even with fewer than 1000 detected counts and in the presence of two or three nuclides at the same time. In this work, we experimentally studied the robustness of a state-of-the-art unmixing algorithm to different radiation background spectra, due to varying atmospheric conditions, in the 16 °C to 28 °C temperature range. In the presence of background, the algorithm is able to identify the nuclides present in unknown radionuclide mixtures of three nuclides, when at least 1000 counts from the sources are detected. With fewer counts available, we found larger differences of approximately 35.9% between estimated nuclide fractions and actual ones. In these low count rate regimes, the uncertainty associated by our algorithm with the identified fractions could be an additional valuable tool to determine whether the identification is reliable or a longer measurement to increase the signal-to-noise ratio is needed. Moreover, the algorithm identification performances are consistent throughout different data sets, with negligible differences in the presence of background types of different intensity and spectral shape.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Charged particle diagnostics for inertial confinement fusion and high-energy-density physics experiments

MeV-range ions generated in inertial confinement fusion (ICF) and high-energy-density physics experiments carry a wealth of information, including fusion reaction yield, rate, and spatial emission profile; implosion areal density; electron temperature and mix; and electric and magnetic fields. Here, the principles of how this information is obtained from data and the charged particle diagnostic suite currently available at the major US ICF facilities for making the measurements are reviewed. Time-integrating instruments using image plate, radiochromic film, and/or CR-39 detectors in different configurations for ion counting, spectroscopy, or emission profile measurements are described, along with time-resolving detectors using chemical vapor deposited diamonds coupled to oscilloscopes or scintillators coupled to streak cameras for measuring the timing of ion emission. A brief description of charged-particle radiography setups for probing subject plasma experiments is also given. The goal of the paper is to provide the reader with a broad overview of available capabilities, with reference to resources where more detailed information can be found.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

WE-AB-BRB-02: Development of a Micro-Sized Dosimeter for Real-Time Dose Monitoring and Small Field Dosimetry

Purpose: To investigate a miniature optical dosimeter for real-time, high-resolution dosimetry, and explore its potential applications for in vivo measurements and small field dosimetry. Methods: A micro-sized hemispherical (400 µm radius) scintillating detector was constructed from lanthanide activated phosphors doped with Europium (GOS:Eu) and encapsulated in a 17 gauge plastic catheter. A photon counting PMT and CCD-chip spectrometer were used to detect signals emitted from the detector. A single band-passing spectral approach (630nm) was implemented to discriminate the micro-phosphor optical signal from background signals (Cerenkov radiation) in the optical fiber. To test real-time monitoring capabilities, a 3D-printed phantom was used to detect an 192Ir HDR brachytherapy source at locations ranging from 1 to 4 cm radially and 12 cm along the travel axis of the HDR wire. To test the application of the micro-sized detector for small field dosimetry, the linearity of detector was characterized through irradiation of 6MV photon beam at dose-rates ranging from 100 to 600 MU, and the effect of field size was characterized through detections of beams ranging from 30×30 to 1×1 cm2 size. Results: With a 1 second integration time for the spectrometer, the recorded measurements indicated that the micro-sized detector allowed accurate detection of source position at distances of up to 6 cm along the axis of travel in water. EB measurements showed that the detected signal was linearly correlated with dose rate (R{sup 2} = 0.99). The crossbeam profile was determined with a step size of ∼500 µm. Conclusion: Miniaturization of optical dosimeters is shown to be possible through the construction of lanthanide activated doped phosphors detectors. The small size of the detector makes it amenable to a variety of applications, including real-time dose delivery verification during HDR brachytherapy and EB beam calibrations in small fields.

60 APPLIED LIFE SCIENCES↗

Single-Volume Scatter Camera (Final Report)

This document serves as a comprehensive final report for the Single-Volume Scatter Camera (SVSC) project. Most of the work over the course of this project has been documented in journal articles, conference papers, and other reports. We therefore reference those materials for detailed presentation of our technical results. The most recent efforts on the project have not been published and are presented in detail here. We present characterizations of two neutron scatter camera prototypes; one using a monolithic geometry, and one using an optically segmented geometry. Both detectors employ plastic scintillator with SiPM-based readout. For the monolithic prototype, we present calibrations of several detector parameters made using a set of dark counts. In particular, we employ a coincidence analysis to characterize the distribution external optical crosstalk, along with the relative timing of the different SiPMs. For the optically segmented prototype we present the results of calibrations made using a tagged 22 Na source, as well as the results of an imaging measurement made using a tagged AmBe source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Two-component model for cosmic-ray fluctuations at neutron monitor energies

A formal model for the fluctuations of the cosmic-ray intensity near earth is presented. For frequencies exceeding 5 x 10 to the -6 Hz, the fluctuations are due to field-aligned-anisotropy induced interplanetary 'scintillations' of cosmic rays, while for lower frequencies the effects of non-field-aligned anisotropies dominate. Cross-correlations between neutron monitor counting rates and the interplanetary magnetic field components are presented which support the model.

Jokipii, J. R.↗

Spectrum of the gamma-ray diffuse component observed from HEAO-1

The spectrum of the diffuse X and gamma ray background was measured between 15 keV and 4 MeV with the scintillation detectors aboard the HEAO 1 satellite. The apertures of the detectors were modulated on time scales of hours and the difference in counting rates measured the diffuse component flux. The observed spectrum is presented and compared with other measurements. At least two components are indicated, one below -100 keV and the other above. Possible origins are discussed.

Gruber, D. E.↗

Muon-induced backgrounds in the CUORICINO experiment

To better understand the contribution of cosmic ray muons to the CUORICINO background, ten plastic scintillator detectors were installed at the CUORICINO siteand operated during the final 3 months of the experiment. From these measurements, an upper limit of 0.0021 counts/(keV.kg.yr) (95percent c.l.) was obtained on the cosmicray induced background in the neutrinoless double beta decay region of interest. The measurements were also compared to Geant4 simulations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗