Search NASA⌕ Search

SEARCH · Search NASA

Results for “SEQUENTIAL DETECTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

A new algorithm for estimating radioxenon concentrations

A new algorithm (Xcounts) is introduced for estimating the activity concentrations of the xenon isotopes 131m Xe, 133m Xe, 133 Xe, and 135 Xe using beta-gamma coincidence data. The algorithm simultaneously estimates the decay counts associated with the four xenon isotopes, background, and radon in contrast to the net-counts method that uses sequential residual removal to account for background and interreferences. Calibration data for background counts are determined from gas-background measurements and simulation. In Xcounts, the false positive count rates for 131m Xe and 133m Xe are lower than the false positive rates for 133 Xe and 135 Xe. This algorithm appears to reliably detect the metastable isotopes at lower activity levels than the net-counts method and have similar performance for the other isotopes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Bioleaching ion-unexchangeable rare earth in ion-adsorption type rare earth waste tailing

Ion-adsorption type rare earth ores (IREO) in China serve as the primary source of medium and heavy rare earth globally. With the rapidly growing demand for rare earth elements (REEs) and the dwindling supply of premium IREO, enhancing the recovery of REEs, especially the ion-unexchangeable REEs with ultra-low content and ambiguous speciation from IREO or its tailing, has become a critical trend and challenge. Here, this study identified the occurrences of ion-unexchangeable REEs, primarily detected in Fe-enriched minerals, xenotime, and monazite of IREO using TESCAN integrated mineral analyzer (TIMA) and laser ablation inductively coupled plasma mass spectrometer (LA-ICP-MS) analysis. To extract these elusive REEs, a bioleaching technique utilizing Aspergillus niger (A. niger) metabolites was proposed, achieving a leaching yield of 31.4 wt%. Complementary sequential chemical extraction methods (SCEM), X-ray photoelectron spectroscopy (XPS), and density functional theory (DFT) calculations further elucidate the underlying mechanism, involving the carboxylic acid produced by the metabolic process of microbes that dissolves goethite by disrupting Fe—O bonds and liberating REEs, which complexed with carboxylate (R—COO—), to promote further dissolution. This work offers insight into enhancing the recovery of ion-unexchangeable REEs from IREO or its tailing, paving the way for sustainable and efficient rare earth mining practices.

42 ENGINEERING↗

Quality-Controlled Meteorological Data from the Flood Control District of Maricopa County (FCDMC) Network, Phoenix, Arizona (1987-2024)

This dataset contains 15- or 30-minute interval meteorological data from the Flood Control District of Maricopa County (FCDMC), Arizona, USA, covering eight key variables across multiple sensor stations between 1987 and 2024. Each variable is stored as a separate CSV file, containing time-series data that have undergone rigorous quality control (QC) procedures and, where appropriate, short-gap interpolation for consistency. The quality control (QC) pipeline consisted of four sequential tests: (1) a range test to ensure all values fall within physically realistic limits, (2) a step test to identify abrupt and implausible changes between consecutive records, (3) a proximity test that validates flagged values from step test using data from nearby stations and exceedance probability thresholds, and (4) a persistence test to detect and remove periods of unrealistically constant readings. These thresholds were calibrated to Arizona’s environmental conditions and sensor specifications. After QC, short gaps (≤2 hours) were linearly interpolated to ensure consistent temporal resolution, except for wind variables. Due to a major upgrade in FCDMC’s data transmission system, only ALERT-2 protocol data (2016–2024) for wind variables are included; earlier ALERT-1 data were excluded because of irregular sampling and high missing rates. This dataset supports regional climate and infrastructure resilience studies by providing standardized, high-resolution meteorological data for the greater Phoenix metropolitan area.

54 ENVIRONMENTAL SCIENCES↗

Method and apparatus for telemetry adaptive bandwidth compression

Methods and apparatus are provided for automatic and/or manual adaptive bandwidth compression of telemetry. An adaptive sampler samples a video signal from a scanning sensor and generates a sequence of sampled fields. Each field and range rate information from the sensor are hence sequentially transmitted to and stored in a multiple and adaptive field storage means. The field storage means then, in response to an automatic or manual control signal, transfers the stored sampled field signals to a video monitor in a form for sequential or simultaneous display of a desired number of stored signal fields. The sampling ratio of the adaptive sample, the relative proportion of available communication bandwidth allocated respectively to transmitted data and video information, and the number of fields simultaneously displayed are manually or automatically selectively adjustable in functional relationship to each other and detected range rate. In one embodiment, when relatively little or no scene motion is detected, the control signal maximizes sampling ratio and causes simultaneous display of all stored fields, thus maximizing resolution and bandwidth available for data transmission. When increased scene motion is detected, the control signal is adjusted accordingly to cause display of fewer fields. If greater resolution is desired, the control signal is adjusted to increase the sampling ratio.

Graham, Olin L.↗

Delta-doped hybrid advanced detector for low energy particle detection

A delta-doped hybrid advanced detector (HAD) is provided which combines at least four types of technologies to create a detector for energetic particles ranging in energy from hundreds of electron volts (eV) to beyond several million eV. The detector is sensitive to photons from visible light to X-rays. The detector is highly energy-sensitive from approximately 10 keV down to hundreds of eV. The detector operates with milliwatt power dissipation, and allows non-sequential readout of the array, enabling various advanced readout schemes.

Cunningham, Thomas J.↗

Delta-doped hybrid advanced detector for low energy particle detection

A delta-doped hybrid advanced detector (HAD) is provided which combines at least four types of technologies to create a detector for energetic particles ranging in energy from hundreds of electron volts (eV) to beyond several million eV. The detector is sensitive to photons from visible light to X-rays. The detector is highly energy-sensitive from approximately 10 keV down to hundreds of eV. The detector operates with milliwatt power dissipation, and allows non-sequential readout of the array, enabling various advanced readout schemes.

Cunningham, Thomas J.↗

Preliminary Evidence of Gas-Phase Water Splitting on Holmium Nitrogen Oxide Clusters

Preliminary Evidence of Gas-Phase Water Splitting on Holmium Nitrogen Oxide Clusters Christopher A. Zarzana1, Makayla R. Baxter , Introduction: Molecular hydrogen is a potential energy carrier that could be used to help implement a clean energy economy if it is generated from splitting of water. Improvements in the efficiencies of water-splitting electrolyzers relies on development of novel materials with enhanced performance. However, research in this area is slowed due to underdeveloped understanding of the mechanisms of device performance due to challenges interrogating the fundamental chemical reactions at play in bulk materials. Studies of the intrinsic reactivity of clusters that are representative of the reactive sites of these materials can increase understanding of the fundamental reaction mechanisms involved in hydrogen production, allowing for more efficient development of new water-splitting materials. Methods: Holmium tetranitrato ([Ho(NO3)4]-) clusters were generated in gas-phase using the electrospray ionization source of a Bruker (Billerica, MA, USA) micrOTOF-Q II quadrupole time-of-flight mass spectrometer. Spray solutions consisted of aqueous holmium (Ho) nitrate solutions (at nominally 3 mM) diluted to 30 µM in acetonitrile. The holmium (Ho) tetranitrato clusters were isolated using the quadrupole and were subsequently activated and allowed to react with background water in the collision cell. High resolution, high mass accuracy spectra were recorded using the time-of-flight. Mass accuracy was ensured using external calibration with Agilent (Santa Clara, CA, USA) ESI-L Low Concentration tuning mix. Preliminary data: Collisional activation of the holmium tetranitrato complexes ([Ln(NO3)4]-) resulted in an expected series of ions resulting from the loss of ·NO and ·NO2. This included an ion at m/z = 382.885 assigned as [HoO2(NO3)3]- (theoretical m/z=382.884, error=-1.2 ppm), resulting from loss of ·NO, and an ion at m/z=366.890 assigned as [HoO(NO3)3]- (theorical m/z=366.889, error=-1.8 ppm), resulting from loss of ·NO2. Additional ions were detected that would result from more complicated losses from [Ho(NO3)4]-, including ions at m/z=320.898 assigned as [HoO2(NO3)2]- (theoretical m/z=320.896, error=-4.9 ppm), at m/z=304.904 assigned as [HoO(NO3)2]- (theoretical m/z=304.901, error=-8.1 ppm, very low signal), and at m/z=288.908 assigned as [Ho(NO3)2]- (theoretical m/z=288.907, error=-3.4 ppm). This ion series would arise from loss of some combination of ·NO, ·NO2, and ·NO3, although it is not known whether these losses occur sequentially (e.g. loss of ·NO and ·NO3 to yield [HoO2(NO3)2]-) or as a single species (e.g. direct loss of N2O4). These ions were accompanied by a complementary series representing addition of a single water molecule. This included an ion at m/z=338.908 assigned as [HoO2(NO3)2H2O]- (theoretical m/z=338.907, error=-4.1 ppm), an ion at m/z=322.912 assigned as [HoO(NO3)2H2O]- (theoretical m/z=322.912, error=1.2 ppm), and an ion at m/z=306.918 assigned as [Ho(NO3)2H2O]-, (theoretical m/z=306.918, error=-3.7 ppm). An additional hydrated ion was observed at m/z=276.921 assigned as [HoO2(NO3) H2O]- (theoretical m/z=276.919, error=-7.3 ppm), although corresponding dehydrated ion was not observed. An additional ion was observed at m/z=367.898 that has been assigned as [Ho(NO3)3OH]- (theoretical m/z=367.897, error=-2.5 ppm). It is hypothesized that this ion arises from addition of water to [Ho(NO3)3]- followed by elimination of a hydrogen radical. Neither [Ho(NO3)3]- nor [Ho(NO3)3H2O]- were detected, suggesting that, if the hypothesis is correct, addition of water to [Ho(NO3)3]- and its subsequent splitting is rapid. Elimination of HNO3 from [Ho(NO3)4H2O]- could also yield [Ho(NO3)3OH]-; however, no [Ho(NO3)4H2O]- ions were observed. Novelty: Potential evidence of water splitting on gas-phase lanthanide clusters offers a way to study the intrinsic reactivity of hydrogen-generation materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High-resolution in-beam video rate imaging with the ClearXCam for synchrotron beamlines

The ClearXCam detector is a new video rate imaging in-beam monitor based on a diamond sensor. Imaging with 2304 effective pixels is achieved by sequentially biasing one of 48 metal stripes on one side of a diamond sensor, while reading out the current from 48 stripes on the other side of the sensor. This system was characterized for real-time X-ray beam diagnostics at synchrotron beam­line 17-BM at the National Synchrotron Light Source II. Significant results include: detection of in-beam structure via the imaging mode, beam focusing in one minute with real-time imaging feedback during a focusing event, linearity over five orders of magnitude, validation of a fast mode operating at 100 Hz, and sub-micron beam-positioning resolution. The system is now available commercially.

36 MATERIALS SCIENCE↗

High-performance organic photodetectors enabled by a refined fibrillar multiphase morphology

Film morphology of donor:acceptor blend layers plays a critical role in photon-to-current efficiency and dark/noise current of organic photodetectors (OPDs). One effective approach to manipulate crystallization and mesoscale phase separation of such blend layers is sequential casting (SC). However, the guiding strategies to control the morphology and the impacts on OPD performance of the SC films remain elusive, as the film structural evolution during SC is different from conventional blend casting (BC). In this report a refined fibrillar multiphase morphology is demonstrated by SC in an NT812:IEICO-4F blend film, where the high-quality IEICO-4F crystallites infiltrate the robust NT812 fibril network from the surface to the bulk. Such a morphology leads to improved charge generation and collection, reduced trap states, and enhanced charge block capability of resultant device, enabling simultaneous achievement of high external quantum efficiency and low dark/noise current. A maximum special detectivity of 5 × 10 13 Jones is achieved at 860 nm under –0.1 V, which is among the highest detectivities for vis-to-NIR OPDs. The linear dynamic range and response speed are also improved. Such enhancements are parallelly observed from OPD devices based on other blend systems with similar fibrillar refinement, which provides guidelines for film structure manipulation towards high OPD performance.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Sequential Probability Ratio Test for Collision Avoidance Maneuver Decisions

When facing a conjunction between space objects, decision makers must chose whether to maneuver for collision avoidance or not. We apply a well-known decision procedure, the sequential probability ratio test, to this problem. We propose two approaches to the problem solution, one based on a frequentist method, and the other on a Bayesian method. The frequentist method does not require any prior knowledge concerning the conjunction, while the Bayesian method assumes knowledge of prior probability densities. Our results show that both methods achieve desired missed detection rates, but the frequentist method's false alarm performance is inferior to the Bayesian method's

Carpenter, J. Russell↗

A Practical Methodology for Quantifying Random and Systematic Components of Unexplained Variance in a Wind Tunnel

This paper documents a check standard wind tunnel test conducted in the Langley 0.3-Meter Transonic Cryogenic Tunnel (0.3M TCT) that was designed and analyzed using the Modern Design of Experiments (MDOE). The test designed to partition the unexplained variance of typical wind tunnel data samples into two constituent components, one attributable to ordinary random error, and one attributable to systematic error induced by covariate effects. Covariate effects in wind tunnel testing are discussed, with examples. The impact of systematic (non-random) unexplained variance on the statistical independence of sequential measurements is reviewed. The corresponding correlation among experimental errors is discussed, as is the impact of such correlation on experimental results generally. The specific experiment documented herein was organized as a formal test for the presence of unexplained variance in representative samples of wind tunnel data, in order to quantify the frequency with which such systematic error was detected, and its magnitude relative to ordinary random error. Levels of systematic and random error reported here are representative of those quantified in other facilities, as cited in the references.

Deloach, Richard↗

Wald Sequential Probability Ratio Test for Space Object Conjunction Assessment

This paper shows how satellite owner/operators may use sequential estimates of collision probability, along with a prior assessment of the base risk of collision, in a compound hypothesis ratio test to inform decisions concerning collision risk mitigation maneuvers. The compound hypothesis test reduces to a simple probability ratio test, which appears to be a novel result. The test satisfies tolerances related to targeted false alarm and missed detection rates. This result is independent of the method one uses to compute the probability density that one integrates to compute collision probability. A well-established test case from the literature shows that this test yields acceptable results within the constraints of a typical operational conjunction assessment decision timeline. Another example illustrates the use of the test in a practical conjunction assessment scenario based on operations of the International Space Station.

Navigation↗

KL techniques for optimal processing of time sequential imagery

Time-sequential imagery is difficult to analyze because of its high dimensionality. This paper advances a new algorithm that screens input data in an intelligent way, discards data with negligible information, and uses the remaining images to represent the sequence in an optimal compact form. Data are presented to illustrate how this algorithm can be used to do novelty filtering, novelty detection, segmentation, background independent modeling, and classification.

Vermeulen, Pieter↗

Detecting fractures and monitoring hydraulic fracturing processes at the first EGS Collab testbed using borehole DAS ambient noise

Enhanced geothermal systems (EGS) require cost-effective monitoring of fracture networks. We validate the capability of using borehole distributed acoustic sensing (DAS) ambient noise for fracture monitoring using core photos and core logs. The EGS Collab project has conducted 10 m scale field experiments of hydraulic fracture stimulation using 50–60 m deep experimental wells at the Sanford Underground Research Facility (SURF) in Lead, South Dakota. The first EGS Collab testbed is located at 1616.67 m (4850 ft) depth at SURF and consists of one injection well, one production well, and six monitoring wells. All wells are drilled subhorizontally from an access tunnel called a drift. The project uses a single continuous fiber-optic cable installed sequentially in the six monitoring wells to record DAS data for monitoring hydraulic fracturing during stimulation. We analyze 60 s time records of the borehole DAS ambient noise data and compute the noise root-mean-square (rms) amplitude on each channel (points along the fiber cable) to obtain DAS ambient noise rms amplitude depth profiles along the monitoring wellbore. Our noise rms amplitude profiles indicate amplitude peaks at distinct depths. We compare the DAS noise rms amplitude profiles with borehole core photos and core logs and find that the DAS noise rms amplitude peaks correspond to the locations of fractures or lithologic changes indicated in the core photos or core logs. We then compute the hourly DAS noise rms amplitude profiles in two monitoring wells during three stimulation cycles in 72 h and find that the DAS noise rms amplitude profiles vary with time, indicating the fracture opening/growth or closing during the hydraulic stimulation. Our results demonstrate that borehole DAS passive ambient noise can be used to detect fractures and monitor fracturing processes in EGS reservoirs.

58 GEOSCIENCES↗

Genarris 2.0: A Random Structure Generator for Molecular Crystals

Genarris is an open source Python package for generating random molecular crystal structures with physical constraints for seeding crystal structure prediction algorithms and training machine learning models. Here we present a new version of the code, containing several major improvements. A MPI-based parallelization scheme has been implemented, which facilitates the seamless sequential execution of user-defined workflows. A new method for estimating the unit cell volume based on the single molecule structure has been developed using a machine-learned model trained on experimental structures. A new algorithm has been implemented for generating crystal structures with molecules occupying special Wyckoff positions. A new hierarchical structure check procedure has been developed to detect unphysical close contacts efficiently and accurately. New intermolecular distance settings have been implemented for strong hydrogen bonds. To demonstrate these new features, we study two specific cases: benzene and glycine. Genarris finds the experimental structures of the two polymorphs of benzene and the three polymorphs of glycine. Program summary Program Title: Genarris 2.0 Program Files doi: http://dx.doi.org/10.17632/grx6mz4pjn.1 Licensing provisions: BSD-3 Clause Programming language: Python, C External routines/libraries: Spglib, ASE, pymatgen, SciPy, mpi4py, scikit-learn, PyTorch, FHI-aims. Nature of problem: Molecular crystal structure prediction. Solution method: Genarris 2.0 generates molecular crystal structures over the 230 space groups, on general and special Wyckoff positions, using physical constraints. Down-sampling of the generated structures may be performed subsequently, based on molecular crystal packing descriptors and an unsupervised machine learning algorithm. Lastly, ab initio structure relaxation may be performed for the final pool. Depending on the user-defined workflow implemented, Genarris may be used to generate diverse molecular crystal datasets to seed evolutionary algorithms or to train machine learning algorithms or as a standalone crystal structure prediction method. Restrictions: For crystal structure generation, the molecule of interest must be semi-rigid with no bond rotational degrees of freedom. Unusual features: Genarris 2.0 is a highly distributed program, making use of MPI for Python parallelization. The user has the ability to design and implement workflows by executing a user-defined list of procedures. Genarris 2.0 offers new features including a machine learning model for estimating the molecular volume in the solid state from the single molecule structure, structure generation in special Wyckoff positions of space groups, hierarchical structure checks including rigorous treatment of non-orthogonal structures, and clustering and down-selection workflows combining first principles simulations with machine learning. (C) 2020 Elsevier B.V. All rights reserved.

Crystal structure prediction↗

Selective photo-excitation of molecules enabled by stimulated Raman pre-excitation

Double resonance excitation, where the energies of vibrational and electronic molecular transitions are combined in a single, sequential excitation process, was introduced in the 1970s but has only been recently applied to microscopy due to the immense progress in Raman spectroscopy. The value of the technique is in combining the chemical selectivity of IR or Raman excitation with the much larger cross-sections of electronic transitions. Recently, it has been shown to be particularly suited for the detection and identification of chromophores at low concentrations and in the presence of spectral crosstalk. However, despite its low quantum yield per pulse sequence, we believe the technique has potential for selective photochemical transformations. There are some cases (e.g., the selective excitation of optogenetic switches) where the low yield may be overcome by repeated excitations to build up biochemically relevant concentrations. Here we show that double resonance excitation using general, non-resonant Raman pre-excitation is a viable candidate for selectively promoting molecules to chemically active energy levels. Further, the use of non-resonant Raman pre-excitation is less constraining than resonant Raman (used in previous double resonance microscopy works) since the choice of Raman pump-Stokes frequencies may be rather freely chosen.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

MTRE

Multi-Token Reliability Estimation (MTRE) is a lightweight, white-box hallucination detector for vision-language models. Instead of using only the first output token, MTRE aggregates logits from the first ~10 tokens and feeds them to a small attention-based reliability head; per-token scores are combined via a sequential log-likelihood-ratio test with early-stopping, and an MTRE-t variant calibrates thresholds via cross-fitting. MTRE reports average gains of +9.4% Accuracy and +14.8% AUROC over common baselines across MAD-Bench, MM-SafetyBench, MathVista, and arithmetic/counting tasks, while adding ~4.3M params and ~1% inference overhead (~26 MB VRAM, ~0.94 ms per detection). Key limitation: requires access to early token logits and is evaluated on a handful of open-source 7B VLMs.

Bhattarai, Manish [Los Alamos National Labs]↗

Techniques for writing and reading data on an optical disk which include formation of holographic optical gratings in plural locations on the optical disk

An optical memory for storing and/or reading data on an optical disk. The optical disk incorporates a material in which holographic gratings can be created, and subsequently detected, at plural locations within the disk by an electro-optical head. Creation and detection of holographic gratings with variable diffraction efficiency is possible with the electro-optical head. Multiple holographic gratings can also be created at each one of the plural locations via a beam of light which has a different wavelength or point of focus. These data elements can be read by the electro-optical head using a beam of light sequentially varied in wavelength or point of focus to correspond to the multiple holographic gratings to be recorded.

Liu, Tsuen-Hsi↗