Search NASA⌕ Search

SEARCH · Search NASA

Results for “SIGNAL DISCRIMINATOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Close binding of identity and location in visual feature perception

The binding of identity and location information in disjunctive feature search was studied. Ss searched a heterogeneous display for a color or a form target, and reported both target identity and location. To avoid better than chance guessing of target identity (by choosing the target less likely to have been seen), the difficulty of the two targets was equalized adaptively; a mathematical model was used to quantify residual effects. A spatial layout was used that minimized postperceptual errors in reporting location. Results showed strong binding of identity and location perception. After correction for guessing, no perception of identity without location was found. A weak trend was found for accurate perception of target location without identity. We propose that activated features generate attention-calling "interrupt" signals, specifying only location; attention then retrieves the properties at that location.

Orientation↗

A Small Angle Scattering Sensor System for the Characterization of Combustion Generated Particulate

One of the critical issues for the US space program is fire safety of the space station and future launch vehicles. A detailed understanding of the scattering signatures of particulate is essential for the development of a false alarm free fire detection system. This paper describes advanced optical instrumentation developed and applied for fire detection. The system is being designed to determine four important physical properties of disperse fractal aggregates and particulates including size distribution, number density, refractive indices, and fractal dimension. Combustion generated particulate are the primary detection target; however, in order to discriminate from other particulate, non-combustion generated particles should also be characterized. The angular scattering signature is measured and analyzed using two photon optical laser scattering. The Rayleigh-Debye-Gans (R-D-G) scattering theory for disperse fractal aggregates is utilized. The system consists of a pulsed laser module, detection module and data acquisition system and software to analyze the signals. The theory and applications are described.

Feikema, Douglas A.↗

Improved Regolith-Landform and Geological Mapping using AIRSAR Data as an Aid to Mineral Exploration in the North-Eastern Goldfields Region, Western Australia

The distinctive contribution of AIRSAR data in characterizing the regolith-landforms in a relatively vegetation free environment are discussed. AIRSAR frame processed data were initially MAF-cleaned to enhance the signal content of the data before geocoding to AMG coordinates. Colors in a three frequency single polarization combination image C-, L- P- bands, and in an enhancement of pedestal height, relate directly to the scale of surface roughness of the various regolith units Examination of the AIRSAR enhancements reveals that in mafic terrain, and to a lesser extent, in felsic terrain, AIRSAR data provides discrimination between the principle geomorphic regimes, relict, erosional and depositional. A multivariate statistical technique called an all-possible subsets calculation was used to examine the degree of polarimetric separation between selected regolith-landforms for all combinations of the nine band AIRSAR radar. An unanticipated aspect of the research was the identification on the AIRSAR imagery of previously unmapped structural features.

Tapley, Ian J.↗

Active microwave classification of sea ice

Radar backscatter studies of Arctic sea ice have been carried out over a number of years with the intent to acquire physical property information through the examination of microwave signatures. The breadth of these studies continues to expand; as an example, measurements are now conducted at frequencies from 500 MHz to about 100 GHz. One of the scientific goals of this work has been to develop an improved outstanding of the scattering processes at play. A second, equally important goal has been to apply the knowledge gained in examining the backscatter response of ice and snow made in conjunction with the detailed scene characterizations, the insight gained through theoretical modeling and parametric study, and the data entered into the radar signature library to develop procedures to convert microwave signal information (available in the very near future) into valuable data products. This should ultimately provide a better understanding of the environment. The author discusses what has been learned through the many efforts associated with the near-surface scatterometer measurement programs and how the knowledge gained is assisting in the development of future sea ice type satellite algorithms. The logic and mechanisms used in discriminating sea ice types are presented.

Onstott, Robert G.↗

The use of digital techniques to examine the intermittent region of a turbulent jet

Voltage signals, sampled at a high rate in the intermittent region of a round jet, are analyzed to provide instantaneous velocity vector information and measures of the vorticity and dissipation scales. A clustering routine to assess the feasibility of using the voltage readings to define the vortical, nonvortical state of the flow is also utilized. The results indicate that the clustering routine is partially successful; more sophisticated discrimination techniques will be required for a complete specification.

Foss, J. F.↗

Arctic Tundra Vegetation Functional Types Based on Photosynthetic Physiology and Optical Properties

Climate change in tundra regions may alter vegetation species composition and ecosystem carbon balance. Remote sensing provides critical tools for monitoring these changes as optical signals provide a way to scale from plot measurements to regional patterns. Gas exchange measurements of pure patches of key vegetation functional types (lichens, mosses, and vascular plants) in sedge tundra at Barrow AK, show three significantly different values of light use efficiency (LUE) with values of 0.013+/-0.001, 0.0018+/-0.0002, and 0.0012 0.0001 mol C/mol absorbed quanta for vascular plants, mosses and lichens, respectively. Further, discriminant analysis of patch reflectance identifies five spectral bands that can separate each vegetation functional type as well as nongreen material (bare soil, standing water, and dead leaves). These results were tested along a 100 m transect where midsummer spectral reflectance and vegetation coverage were measured at one meter intervals. Area-averaged canopy LUE estimated from coverage fractions of the three functional types varied widely, even over short distances. Patch-level statistical discriminant functions applied to in situ hyperspectral reflectance successfully unmixed cover fractions of the vegetation functional types. These functions, developed from the tram data, were applied to 30 m spatial resolution Earth Observing-1 Hyperion imaging spectrometer data to examine regional variability in distribution of the vegetation functional types and from those distributions, the variability of LUE. Across the landscape, there was a fivefold variation in tundra LUE that was correlated to a spectral vegetation index developed to detect vegetation chlorophyll content.

Huemmrich, Karl F.↗

Measurement of atmospheric OH by titration of near-IR fluorescent dyes

Recent research has shown that certain polymethine dyes can be detected at ultratrace levels (greater than or equal to 6x10(exp -14) M) in solution by fluorimetry. These detection limits are possible because of the inherent sensitivity of fluorescence techniques, because the dyes fluoresce in the near infrared region where background interference is negligible, and because powerful infrared diode lasers are now available to improve the signal to noise ratio. Other work has shown that the hydroxyl radical destroys the ability of polymethine dyes to fluoresce. These observations form the basis for a new hydroxyl radical detector that is essentially a fluorometric titrator. Theoretically, the detector should show an acceptable sensitivity and response time. Assuming that the atmospheric HO concentration is about 10(exp -11) moles m(exp -3) (i.e. 10(exp 6) molecules cm(exp -3)), then 10 L of air 'titrated' with 20 mL of 10(exp -11) M dye solution (an easily detected concentration) should result in a drop in the fluorescent signal of 50 percent - a readily detectable change. At a flow rate of 3 L min(exp -1) the sampling time would be 3 minutes. The biggest potential problem is selectivity: other oxidants may also cause the fluorescence signal to be lost. The chemistry of polymethine dyes has not been studied in detail and so no quantitative data are available. However, a survey of the literature suggests that in general HO should react up to six orders of magnitude faster than HO2 and other radicals such as RO2 and RO. It should also react much more rapidly than H2O2 and O3. Thus it may be possible to discriminate kinetically against potential interfering substances. It was shown in the laboratory that 10(exp -4) M H2O2 has little effect on the absorption spectrum of the dye IR125 over a period of hours but that the band at 780 nm is slowly lost in water over a period of days even under argon in the dark. By contrast, DMSO solutions of IR125 are stable.

Betterton, Eric A.↗

Data Format Classification for Autonomous Software Defined Radios

We present maximum-likelihood (ML) coherent and noncoherent classifiers for discriminating between NRZ and Manchester coded (biphase-L) data formats for binary phase-shift-keying (BPSK) modulation. Such classification of the data format is an essential element of so-called autonomous software defined radio (SDR) receivers (similar to so-called cognitive SDR receivers in the military application) where it is desired that the receiver perform each of its functions by extracting the appropriate knowledge from the received signal and, if possible, with as little information of the other signal parameters as possible. Small and large SNR approximations to the ML classifiers are also proposed that lead to simpler implementation with comparable performance in their respective SNR regions. Numerical performance results obtained by a combination of computer simulation and, wherever possible, theoretical analyses, are presented and comparisons are made among the various configurations based on the probability of misclassification as a performance criterion. Extensions to other modulations such as QPSK are readily accomplished using the same methods described in the paper.

classification↗

Study to investigate and evaluate means of optimizing the Ku-band combined radar/communication functions for the space shuttle

The performance of the space shuttle orbiter's Ku-Band integrated radar and communications equipment is analyzed for the radar mode of operation. The block diagram of the rendezvous radar subsystem is described. Power budgets for passive target detection are calculated, based on the estimated values of system losses. Requirements for processing of radar signals in the search and track modes are examined. Time multiplexed, single-channel, angle tracking of passive scintillating targets is analyzed. Radar performance in the presence of main lobe ground clutter is considered and candidate techniques for clutter suppression are discussed. Principal system parameter drivers are examined for the case of stationkeeping at ranges comparable to target dimension. Candidate ranging waveforms for short range operation are analyzed and compared. The logarithmic error discriminant utilized for range, range rate and angle tracking is formulated and applied to the quantitative analysis of radar subsystem tracking loops.

Weber, C. L.↗

Varying potential silicon carbide gas sensor

A hydrocarbon gas detection device operates by dissociating or electro-chemically oxidizing hydrocarbons adsorbed to a silicon carbide detection layer. Dissociation or oxidation are driven by a varying potential applied to the detection layer. Different hydrocarbon species undergo reaction at different applied potentials so that the device is able to discriminate among various hydrocarbon species. The device can operate at temperatures between 100.degree. C. and at least 650.degree. C., allowing hydrocarbon detection in hot exhaust gases. The dissociation reaction is detected either as a change in a capacitor or, preferably, as a change of current flow through an FET which incorporates the silicon carbide detection layers. The silicon carbide detection layer can be augmented with a pad of catalytic material which provides a signal without an applied potential. Comparisons between the catalytically produced signal and the varying potential produced signal may further help identify the hydrocarbon present.

Shields, Virgil B.↗

Improved Detection System Description and New Method for Accurate Calibration of Micro-Channel Plate Based Instruments and Its Use in the Fast Plasma Investigation on NASA's Magnetospheric MultiScale Mission

The Fast Plasma Investigation (FPI) on NASAs Magnetospheric MultiScale (MMS) mission employs 16 Dual Electron Spectrometers (DESs) and 16 Dual Ion Spectrometers (DISs) with 4 of each type on each of 4 spacecraft to enable fast (30 ms for electrons; 150 ms for ions) and spatially differentiated measurements of the full 3D particle velocity distributions. This approach presents a new and challenging aspect to the calibration and operation of these instruments on ground and in flight. The response uniformity, the reliability of their calibration and the approach to handling any temporal evolution of these calibrated characteristics all assume enhanced importance in this application, where we attempt to understand the meaning of particle distributions within the ion and electron diffusion regions of magnetically reconnecting plasmas. Traditionally, the micro-channel plate (MCP) based detection systems for electrostatic particle spectrometers have been calibrated using the plateau curve technique. In this, a fixed detection threshold is set. The detection system count rate is then measured as a function of MCP voltage to determine the MCP voltage that ensures the count rate has reached a constant value independent of further variation in the MCP voltage. This is achieved when most of the MCP pulse height distribution (PHD) is located at higher values (larger pulses) than the detection system discrimination threshold. This method is adequate in single-channel detection systems and in multi-channel detection systems with very low crosstalk between channels. However, in dense multi-channel systems, it can be inadequate. Furthermore, it fails to fully describe the behavior of the detection system and individually characterize each of its fundamental parameters. To improve this situation, we have developed a detailed phenomenological description of the detection system, its behavior and its signal, crosstalk and noise sources. Based on this, we have devised a new detection system calibration method that enables accurate and repeatable measurement and calibration of MCP gain, MCP efficiency, signal loss due to variation in gain and efficiency, crosstalk from effects both above and below the MCP, noise margin, and stability margin in one single measurement. More precise calibration is highly desirable as the instruments will produce higher quality raw data that will require less post-acquisition data correction using results from in-flight pitch angle distribution measurements and ground calibration measurements. The detection system description and the fundamental concepts of this new calibration method, named threshold scan, will be presented. It will be shown how to derive all the individual detection system parameters and how to choose the optimum detection system operating point. This new method has been successfully applied to achieve a highly accurate calibration of the DESs and DISs of the MMS mission. The practical application of the method will be presented together with the achieved calibration results and their significance. Finally, it will be shown that, with further detailed modeling, this method can be extended for use in flight to achieve and maintain a highly accurate detection system calibration across a large number of instruments during the mission.

detection system↗

Full-wave and half-wave rectification in second-order motion perception

Microbalanced stimuli are dynamic displays which do not stimulate motion mechanisms that apply standard (Fourier-energy or autocorrelational) motion analysis directly to the visual signal. In order to extract motion information from microbalanced stimuli, Chubb and Sperling [(1988) Journal of the Optical Society of America, 5, 1986-2006] proposed that the human visual system performs a rectifying transformation on the visual signal prior to standard motion analysis. The current research employs two novel types of microbalanced stimuli: half-wave stimuli preserve motion information following half-wave rectification (with a threshold) but lose motion information following full-wave rectification; full-wave stimuli preserve motion information following full-wave rectification but lose motion information following half-wave rectification. Additionally, Fourier stimuli, ordinary square-wave gratings, were used to stimulate standard motion mechanisms. Psychometric functions (direction discrimination vs stimulus contrast) were obtained for each type of stimulus when presented alone, and when masked by each of the other stimuli (presented as moving masks and also as nonmoving, counterphase-flickering masks). RESULTS: given sufficient contrast, all three types of stimulus convey motion. However, only one-third of the population can perceive the motion of the half-wave stimulus. Observers are able to process the motion information contained in the Fourier stimulus slightly more efficiently than the information in the full-wave stimulus but are much less efficient in processing half-wave motion information. Moving masks are more effective than counterphase masks at hampering direction discrimination, indicating that some of the masking effect is interference between motion mechanisms, and some occurs at earlier stages. When either full-wave and Fourier or half-wave and Fourier gratings are presented simultaneously, there is a wide range of relative contrasts within which the motion directions of both gratings are easily determinable. Conversely, when half-wave and full-wave gratings are combined, the direction of only one of these gratings can be determined with high accuracy. CONCLUSIONS: the results indicate that three motion computations are carried out, any two in parallel: one standard ("first order") and two non-Fourier ("second-order") computations that employ full-wave and half-wave rectification.

Motion Perception/physiology↗

Discriminator Stabilized Superconductor/Ferroelectric Thin Film Local Oscillator

A tunable local oscillator with a tunable circuit that includes a resonator and a transistor as an active element for oscillation. Tuning of the circuit is achieved with an externally applied dc bias across coupled lines on the resonator. Preferably the resonator is a high temperature superconductor microstrip ring resonator with integral coupled lines formed over a thin film ferroelectric material. A directional coupler samples the output of the oscillator which is fed into a diplexer for determining whether the oscillator is performing at a desired frequency. The high-pass and lowpass outputs of the diplexer are connected to diodes respectively for inputting the sampled signals into a differential operational amplifier. The amplifier compares the sampled signals and emits an output signal if there is a difference between the resonant and crossover frequencies. Based on the sampled signal, a bias supplied to the ring resonator is either increased or decreased for raising or lowering the resonant frequency by decreasing or increasing, respectively, the dielectric constant of the ferroelectric.

Romanofsky, Robert R.↗

Inclusion of filter modulation in synthetic-discriminant-function construction

A technique in which the filter modulation is included in the synthesis of a synthetic-discriminant-function (SDF) matched spatial filter is presented. In the filter synthesis, a system of simultaneous nonlinear equations is solved with an iteration procedure. A computer simulation of the new method using thresholded images of the Space Shuttle over a range of aspect angles was performed for phase-only filters (POFs) and binary-phase-only filters (BPOFs). The filters constructed are capable of obtaining the specified peak-correlation response to within 1 percent with a high signal-to-clutter-ratio for the one-class problem, the two-class problem, and the multilevel problem. In contrast, conventional projection SDF POFs and BPOFs are unable to produce the desired peak-correlation response.

Jared, David A.↗

Geoscience Laser Altimeter System (GLAS) for the ICESat Mission

The Geoscience Laser Altimeter System (GLAS) is a new generation lidar and is the primary science payload for NASA's ICESat Mission. The GLAS design combines a 10 cm precision surface lidar with a sensitive dual wavelength cloud and aerosol lidar. GLAS will precisely measure the heights of the Earth's polar ice sheets, establish a grid of accurate height profiles of the Earth's land topography, and profile the vertical distribution of clouds and aerosols on a global scale. GLAS will be integrated onto a small spacecraft built by Ball Aerospace, and will be launched into a polar orbit with a 590-630 km altitude at an inclination of 94 degrees. ICESat is is currently planned to launch in winter 2002/03 and GLAS is designed to operate continuously in space for a minimum of 3 years. GLAS will measure the vertical distance from orbit to the Earth's surface with pulses from a ND:YAG laser at a 40 Hz rate. Each 6 nsec wide 1064 nm laser pulse is used to produce a single range measurement. On the surface, the laser footprints have 66 m diameter and approx. 170 m center-center spacings. The GLAS receiver uses a I m diameter telescope to detect laser backscatter and a Si APD to detect the 1064 nm signals. The detector's output is sampled by a digital ranging receiver, which records each transmitted pulse and surface echo waveform with 1 nsec (15 cm) resolution. Each echo pulse is digitized and is reported to ground with a record length of from 200 to 544 samples, depending on the spacecraft's location . The GLAS location and epoch times are measured by a precision GPS receiver carried on the ICESat spacecraft. Initial processing of the echo waveforms within GLAS permits discrimination between cloud and surface echoes for selecting appropriate waveform samples. This selection is guided by an on-board DEM which is used to set the boundaries for the echo pulse search algorithm. Subsequent ground-based echo pulse analysis, along with GPS-based clock frequency estimates, permit final determination of the range to the surface, degree of pulse spreading, and vertical distribution of any vegetation illuminated by the laser. Accurate knowledge of the laser beam's pointing angle is needed to prevent height biases when measuring over tilted surfaces, such as near the boundaries of ice sheets. For surfaces with 2 deg. slopes, knowledge of pointing angle of the beam's centroid angle to better than 10 urad is needed. GLAS uses a stellar reference system (SRS) to measure the pointing angle of each laser firing relative to inertial space. The SRS uses a high precision star camera oriented toward local zenith and a gyroscope to determine the inertial orientation of the SRS optical bench. The far field pattern of each laser is measured pulse relative to the star camera with a laser reference system (LRS). GLAS will also measure the vertical distributions of clouds and aerosols by recording the vertical profiles of laser pulse backscatter at both 1064 and 532 nm. The 1064 rim measurements use the Si APD detector and will be used to measure the height and echo pulse shape from thicker clouds. The lidar receiver at 532 nm uses a narrow bandwidth etalon filter and highly sensitive photon counting detectors. The 532 nm backscatter profiles will be used to measure the vertical extent of thinner clouds and the atmospheric boundary layer. The GLAS instrument component development is complete and the instrument is undergoing final testing and qualification at NASA-Goddard. The GLAS "as-built" characteristics and its expected measurement performance will be discussed.

Abshire, James B.↗

Development of arrays of position-sensitive microcalorimeters for Constellation-X

We are developing arrays of position-sensitive transition-edge sensor (POST) X-ray detectors for future astronomy missions such as NASA's Constellation-X. The POST consists of multiple absorbers thermally coupled to one or more transition-edge sensor (TES). Each absorber element has a different thermal coupling to the TES. This results in a distribution of different pulse shapes and enables position discrimination between the absorber elements. POST'S are motivated by the desire to achieve the largest possible focal plane area with the fewest number of readout channels and are ideally suited to increasing the Constellation-X focal plane area, without comprising on spatial sampling. Optimizing the performance of POST'S requires careful design of key parameters such as the thermal conductances between the absorbers, TES and the heat sink. as well as the absorber heat capacities. Using recently developed signal processing algorithms we have investigated the trade-off between position-sensitivity, energy resolution and pulse decay time. based on different device design parameters for PoST's. Our new generation of PoST's utilize technology successfully developed on high resolution (approximately 2.5eV) single pixels arrays of Mo/Au TESs. also under development for Constellation-X. This includes noise mitigation features on the TES and low resistivity electroplated absorbers. We report on the first experimental results from these new one and two-channel PoST"s, consisting of all Au and composite Au/Bi absorbers, which are designed to achieve an energy resolution of < 10 eV. coupled with count-rates of 100's per pixel per second and position sensitivity over the energy range 0.3-10 keV.

Smith, S. J.↗

A New Crater Near Insight: Implications for Seismic Impact Detectability on Mars

A new 1.5 m diameter impact crater was discovered on Mars only ~40 km from the InSight lander. Context camera images constrained its formation between 21 February and 6 April 2019; follow-up High Resolution Imaging Science Experiment images resolved the crater. During this time period, three seismic events were identified in InSight data. We derive expected seismic signal characteristics and use them to evaluate each of the seismic events. However, none of them can definitively be associated with this source. Atmospheric perturbations are generally expected to be generated during impacts; however, in this case, no signal could be identified as related to the known impact. Using scaling relationships based on the terrestrial and lunar analogs and numerical modeling, we predict the amplitude, peak frequency, and duration of the seismic signal that would have emanated from this impact. The predicted amplitude falls near the lowest levels of the measured seismometer noise for the predicted frequency. Hence, it is not surprising this impact event was not positively identified in the seismic data. Finding this crater was a lucky event as its formation this close to InSight has a probability of only ~0.2, and the odds of capturing it in before and after images are extremely low. We revisit impact-seismic discriminators in light of real experience with a seismometer on the Martian surface. Using measured noise of the instrument, we revise our previous prediction of seismic impact detections downward, from ~a few to tens, to just ~2 per Earth year, still with an order of magnitude uncertainty.

I. J. Daubar↗

A Signal Detection Theory Approach to Evaluating Oculometer Data Quality

Currently, data quality is described in terms of spatial and temporal accuracy and precision [Holmqvist et al. in press]. While this approach provides precise errors in pixels, or visual angle, often experiments are more concerned with whether subjects'points of gaze can be said to be reliable with respect to experimentally-relevant areas of interest. This paper proposes a method to characterize oculometer data quality using Signal Detection Theory (SDT) [Marcum 1947]. SDT classification results in four cases: Hit (correct report of a signal), Miss (failure to report a ), False Alarm (a signal falsely reported), Correct Reject (absence of a signal correctly reported). A technique is proposed where subjects' are directed to look at points in and outside of an AOI, and the resulting Points of Gaze (POG) are classified as Hits (points known to be internal to an AOI are classified as such), Misses (AOI points are not indicated as such), False Alarms (points external to AOIs are indicated as in the AOI), or Correct Rejects (points external to the AOI are indicated as such). SDT metrics describe performance in terms of discriminability, sensitivity, and specificity. This paper presentation will provide the procedure for conducting this assessment and an example of data collected for AOIs in a simulated flightdeck environment.

Latorella, Kara↗