High-lift and lateral control characteristics of an NACA 652-215 semispan wing equipped with plug and retractable ailerons and a full-span slotted flap
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Wall Mach number distributions were determined over a range of test-section free-stream Mach numbers from 0.2 to 0.92. The test section was slotted and had a nominal porosity of 11 percent. Reentry flaps located at the test-section exit were varied from 0 (fully closed) to 9 (fully open) degrees. Flow was bled through the test-section slots by means of a plenum evacuation system (PES) and varied from 0 to 3 percent of tunnel flow. Variations in reentry flap angle or PES flow rate had little or no effect on the Mach number distributions in the first 70 percent of the test section. However, in the aft region of the test section, flap angle and PES flow rate had a major impact on the Mach number distributions. Optimum PES flow rates were nominally 2 to 2.5 percent wtih the flaps fully closed and less than 1 percent when the flaps were fully open. The standard deviation of the test-section wall Mach numbers at the optimum PES flow rates was 0.003 or less.
During the past two summers Professor Milanovic conducted Wind tunnel experiments on steady jets-in-cross-flow and synthetic jets. In her anticipated visit during the upcoming summer, she will continue and complete the research on synthetic jets involving 2-dimensional orifices of different aspect ratio as well as inclined slots. In addition, experiments will be conducted on pulsatile jets-in-cross-flow. The pulsation will be provided via an oscillating valve at controllable frequencies. The experiment will involve mainly hot-wire anemometer measurements in the low-speed wind tunnel. Overall goal will be to obtain database and investigate flow control strategies. The research will be of fundamental nature.
Explore the source record for details and available documents.
The National Transonic Facility (NTF) is a fan-driven, closed-circuit, continuous flow, pressurized wind tunnel. The test section is 2.5 m x 2.5 m and 7.62 m long with a slotted-wall configuration. The NTF will have a Mach number range from 0.2 to 1.2, with Reynolds number up to 120 10 to the sixth power at Mach 1 (based on a reference length of 0.25 m). The pressure range for the facility will be from 1 to about 9 bars (1 ban = 100 kPa), and the temperature can be varied from 340 to 78 K. This report provides potential users of the NTF with the information required for preliminary planning to test programs and for preliminary layout of models and model supports which may be used in such programs.
This paper highlights the influence of computational methods on design of a wind tunnel experiment which generically models the nozzle/afterbody flow field of the proposed National Aerospace Plane. The rectangular slot nozzle plume flow field is computed using a three-dimensional, upwind, implicit Navier-Stokes solver. Freestream Mach numbers of 5.3, 7.3, and 10 are investigated. Two-dimensional parametric studies of various Mach numbers, pressure ratios, and ramp angles are used to help determine model loads and afterbody ramp angle and length. It was found that the center of pressure on the ramp occurs at nearly the same location for all ramp angles and test conditions computed. Also, to prevent air liquefaction, it is suggested that a helium-air mixture be used as the jet gas for the highest Mach number test case.
As part of a multiphased program for subsonic transport high-lift flight research, flight tests were conducted on the Transport Systems Research Vehicle (B737-100 aircraft) at the NASA Langley Research Center, to obtain detailed flow characteristics of the high-lift flap system for correlation with computational and wind-tunnel investigations. Pressure distributions, skin friction, and flow-visualization measurements were made on a triple-slotted flap system for a range of flap deflections, chord Reynolds numbers (10 to 21 million), and Mach numbers (0.16 to 0.36). Experimental test results are given for representative flap settings indicating flow separation on the fore-flap element for the largest flap deflection. Comparisons of the in-flight flow measurements were made with predictions from available viscous multielement computational methods modified with simple-sweep theory. Computational results overpredicted the experimentally measured pressures, particularly in the case involving separation of the fore lap, indicating the need for better modeling of confluent boundary layers and three-dimensional sweep effects.
A full aircraft geometry is used to computationally analyze the effectiveness of a pneumatic forebody flow control concept. An overset grid technique is employed to model the aircraft and slot geometry. Steady-state solutions for both isolated forebody and full aircraft configurations are carried out using a thin-layer Navier-Stokes flow solver. A solution obtained using the full aircraft geometry and a flight sideslip condition investigates the effect of sideslip on the leading edge extention vortex burst point. A no-sideslip blowing solution using the isolated forebody at full-scale wind tunnel test conditions is compared with experimental data to determine the accuracy of the numerical method. A solution employing the full geometry and slot blowing at flight conditions is obtained.
Low-speed wind tunnel tests performed by the Naval Ship Research and Development Center (NSRDC) on a circulation control airfoil model was repeated by the Joint Institute for Aerodynamics and Acoustics in an attempt to reproduce the performance results. The model used was a 15% ellipse with interchangeable trailing edges. Surface pressure measurements were taken to obtain lift and pitching moment coefficients as functions of jet blowing momentum, and the momentum deficit in the wake was measured and used to calculate the drag coefficient. The effects of spanwise slot height variation and of leading edge blowing on performance were also investigated. The performance results showed that of the three slot heights tested, a slot height/chord ratio of 0.0022 produced the most lift coefficient for a given blowing rate. Lift obtained in the current test ranged from 2 to 35% lower than the NSRDC test. However, the two data sets compared reasonably well considering wind tunnel and wall blowing scheme differences. The spanwise lift distribution showed less change in lift due to a variation in slot height than expected. The leading edge blowing results demonstrated that although lift initially decreased, a positive lift increment was possible at higher leading edge blowing rates.
A numerical procedure for determining the position (horizontal location, vertical location, and deflection) of a leading edge slat that maximizes the lift of multielement airfoils is presented. The structure of the flow field is calculated by iteratively coupling potential flow and boundary layer analysis. This aerodynamic calculation is combined with a constrained function minimization analysis to determine the position of a leading edge slat so that the suction peak on the nose of the main airfoil is minized. The slat position is constrained by the numerical procedure to ensure an attached boundary layer on the upper surface of the slat and to ensure negligible interaction between the slat wake and the boundary layer on the upper surface of the main airfoil. The highest angle attack at which this optimized slat position can maintain attached flow on the main airfoil defines the optimum slat position for maximum lift. The design method is demonstrated for an airfoil equipped with a leading-edge slat and a trailing edge, single-slotted flap. The theoretical results are compared with experimental data, obtained in the Ames 40 by 80 Foot Wind Tunnel, to verify experimentally the predicted slat position for maximum lift. The experimentally optimized slat position is in good agreement with the theoretical prediction, indicating that the theoretical procedure is a feasible design method.
Fixed leading-edge devices were investigated for alleviating the low speed pitch-up and longitudinal instability of a 74 deg delta wing model. In wind-tunnel tests, Pylon Vortex Generators were shown to be highly effective, compared to leading-edge fences and slots, in raising the pitch-up angle of attack from 8 deg to 28 deg. The subsonic drag penalty was negligible.
The national transonic facility fan driven, closed circuit, continuous flow, pressurized wind tunnel is examined. The test section is 2.500 m x 2.500 m and 7.620 m long with a slotted wall configuration. There are six slots each in the top and bottom walls and two slots per sidewall. To maintain good flow quality and aerodynamic efficiency over the wide range of test capabilities the test section geometry is variable. The position of the test section and bottom walls, the reentry flaps at the rear of the test section slots, and the step height for reentering slot flow are remotely controlled. The test gas may be dry air or nitrogen, which for the elevated temperature (340 K) mode of operation the test medium is normally air, and heat removal is by a water cooled heat exchanger (cooling coil) located at the upstream end of the settling chamber. For the cryogenic mode of operation, heat removal is by evaporation of liquid nitrogen, which is sprayed into the circuit upstream of the fan. By utilizing liquid nitrogen as a coolant, the tunnel test temperature range is variable from 340 to 78 K. When nitrogen is injected into the circuit, venting must occur to maintain a constant pressure. Thermal insulation is installed internal to the pressure shell to minimize energy consumption.
Three dimensional adaptive-wall experiments were performed in the Ames Research Center (ARC) 25- by 13-cm indraft wind tunnel. A semispan wing model was mounted to one sidewall of a test section with solid sidewalls, and slotted top and bottom walls. The test section had separate top and bottom plenums which were divided into streamwise and cross-stream compartments. An iterative procedure was demonstrated for measuring wall interference and for adjusting the plenum compartment pressures to eliminate such interference. The experiments were conducted at a freestream Mach number of 0.60 and model angles of attack between 0 and 6 deg. Although in all the experiments wall interference was reduced after the plenum pressures were adjusted, interference could not be completely eliminated.
Explore the source record for details and available documents.
The results of pressure distribution measurements that were made on a model wing section of a Fieseler F 5 R type airplane are presented. Comparison of those model tests with the corresponding flight tests indicates the limitations and also the advantages of wind tunnel investigations, the advantages being particularly that through the variety of measuring methods employed the more complicated flow conditions may also be clarified. A fact brought out in these tests is that even in the case of "well rounded" slots it is possible for a vortex to be set up at the slot entrance and this vortex is responsible for certain irregularities in the pressure distribution and in the efficiency of the slot.
This paper describes the initial wind tunnels tests in the 5- by 8-ft Boeing Research Wind Tunnel of a near full-scale (20-foot chord) swept wing section having laminar flow control (LFC) by slot suction over its first 30 percent chord. The model and associated test apparatus were developed for use as a testbed for LFC-related experimentation in support of preliminary design studies done under contract with the National Aeronautics and Space Administration. This paper contains the description of the model and associated test apparatus as well as the results of the initial test series in which the proper functioning of the test installation was demonstrated and new data were obtained on the sensitivity of suction-controlled laminar flow to surface protuberances in the presence of crossflow due to sweep.
A wind-tunnel investigation was conducted to determine the effect of deflecting the engine exit of a four-engine double-slotted flap transport to provide STOL performance. Longitudinal aerodynamic data were obtained at various engine exit positions and deflections. The data were obtained at three flap deflections representing cruise, take-off, and landing conditions for a range of angles of attack and various thrust coefficients. Downwash angles at the location of the horizontal tail were measured. The data are presented without analysis or discussion. Photographs of the test configurations are shown.
The performance of two externally blown flap (EBF) wind tunnel models was compared with an engine exhaust flap impingement correlation parameter. One model was a four engine EBF triple slotted flap transport. Isolated engine wake surveys were conducted to define the wake properties of five separate engine configurations for which performance data were available. The other model was a two engine EBF transport for which the engine wake properties were estimated. The correlation parameter was a function of engine exhaust dynamic pressure at the flap location, area of engine exhaust flap impingement, total exhaust area at the flap location, and engine thrust. The distribution of dynamic pressure for the first model was measured; however, the distribution for the second model was assumed to be uniform.