276 records · Page 16

Integrating AI Data Centers with the Power Grid

The rapid expansion of artificial intelligence (AI) has triggered an unprecedented surge in electricity demand, with US data center energy use projected to double or triple 2023 levels by 2028. This exponential growth places strain on grid infrastructure, which can hinder timely construction of desired computing capacity. To bridge this supply-demand gap, utilities and AI developers are increasingly turning to demand flexibility, a strategy that incentivizes shifting or reducing power use during peak periods of grid stress. Data centers are uniquely equipped for flexible operations due to their digital workloads, built-in redundancy, and onsite energy assets. This article outlines four primary mechanisms to enable data center flexibility: computational load flexibility (shifting tasks temporally or geographically), flexible use of core facility infrastructure adjustments, energy storage utilization, and onsite electricity generation. To encourage adoption, utilities are deploying new tariff designs, including voluntary interruptible service riders, mandated flexibility requirements, and streamlined interconnection processes for flexible loads. For the highly capitalized and rapidly growing AI industry, the primary motivators for embracing these strategies are expediting facility interconnection, satisfying emerging regulatory mandates, and mitigating community resistance. While demand flexibility cannot substitute the long-term need for new bulk power generation, it serves as an essential, immediate solution for enabling near-term deployment. By transforming data centers from grid stressors into stabilizing assets, flexible operations can ensure reliable grid integration, ease market pressures, and support a resilient power system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Baseload Hydrogen Production Using Nuclear and Renewable Energy: A Comparative Analysis

As the global push towards net zero carbon gains momentum, the demand for clean hydrogen is expected to grow rapidly across various sectors, including transportation, industries and electrical grids. To meet this growing hydrogen demand, baseload hydrogen production facilities capable of providing a continuous and reliable supply of hydrogen will be necessary throughout the world. This paper explores the technoeconomic feasibility of establishing baseload electrolytic hydrogen production facilities in the United States, utilizing different clean generation resources. The key criteria include maintaining a consistent supply of clean hydrogen without putting baseload demand stress to already vulnerable power grid. In order to do that, the proposed facilities will host onsite clean power generation and energy storage technologies. The proposed facilities can capitalize on available investment and production incentives and have ability to export excess electricity to the utility at a bulk price. Several scenarios are considered based on the clean energy resources to support the electrolysis process including light water reactors (LWRs) currently evaluating retirement options, wind, solar PVs, and advanced small modular reactors (SMRs). For each scenario, a hypothetical hydrogen production facility is considered in a location in the US where the primary generation resource is at its peak strength. Comparative analysis in this paper reveal that the nuclear power plants are most economically viable for baseload hydrogen production facilities, outperforming renewable-based facilities with significantly lower levelized cost of hydrogen (LCOH). Even under best-case scenarios for resource availability, incentives and export prices, renewable-based facilities face challenges due to daily and seasonal generation variability, resulting in large installation sizes and lower capacity factors. Among renewable-based facilities, complementarity hybrids, providing more stable power supply, demonstrate superior economics compared to facilities based on a single renewable technology. While LWR-powered facility can achieve a negative LCOH with incentives, SMR-powered facilities can provide economic hydrogen supply with LCOH below $1/kg with high temperature electrolysis option. The analysis in this paper underscores the pivotal role of nuclear energy in the future hydrogen economy.

08 - HYDROGEN↗

PowerModelsGAT-AI: Physics-Informed Graph Attention for Multi-System Power Flow With Continual Learning

Solving the alternating current power flow equations in real time is essential for secure grid operation, yet classical Newton–Raphson solvers can be slow under stressed conditions. Existing graph neural networks for power flow are typically trained on a single system and often degrade on different systems. We present PowerModelsGAT-AI, a physics-informed graph attention network that predicts bus voltages and generator injections. The model uses bus-type-aware masking to handle different bus types and balances multiple loss terms, including a power-mismatch penalty, using learned weights. We evaluate the model on 14 benchmark systems (4 to 6,470 buses) and train a unified model on 13 of these under contingency conditions with up to two branch outages, achieving an average normalized mean absolute error of 0.89% for voltage magnitudes and R 2 >0.99 for voltage angles. We also show continual learning: when adapting a base model to a new 1,354-bus system, standard fine-tuning causes severe forgetting with error increases exceeding 1000% on base systems, while our experience replay and elastic weight consolidation strategy keeps error increases below 2% and in some cases improves base-system performance. Interpretability analysis shows that learned attention weights correlate with physical branch parameters (susceptance: r=0.38 ; thermal limits: r=0.22 ), and feature importance analysis supports that the model captures established power flow relationships.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Long-Term Impacts of Constrained Transmission Deployment on the Cost-Reliability Tradeoff

Traditional Resource Adequacy (RA) frameworks in the U.S. undervalue the contributions of inter-regional transmission to resource adequacy during stress periods, focusing on the availability of nameplate capacity instead. However, availability of nameplate capacity does not always translate into electricity delivery, especially during tail events. Moreover, the rapid deployment of energy-limited resources and increasing electricity demand challenge existing resource adequacy frameworks and couple regional electricity demand and availability of supply via transmission. We propose a two-stage framework that goes beyond the existing capacity-centered approaches to reveal the RA contributions of transmission. In the first stage we introduce a multi-objective optimization framework to quantify the merits of transmission expansion via Pareto Frontiers under alternative futures of no transmission investment, primary energy resources availability and demand growth. The second stage focuses on tail events and leverages the results of the first stage to characterize the risk profile of regional consumers across the U.S. under the alternative energy futures. We find that no new transmission can lead to a more expensive and less reliable national grid across scenarios, however, the impact on regional RA can vary. The probabilistic analysis reveals that transmission investments can alleviate the tail risk of consumers, however, the availability of fuel resources does not always alleviate regional tail risks. Our findings inform policymakers and utilities on the prioritization of transmission investments to mitigate the risk of widespread outages, also for tail events, and ensure reliable and affordable electricity delivery to all.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Modeling Framework for Data Center

This chapter highlights the critical need for advanced modeling of data centers due to their rapidly increasing energy consumption and impact on grid reliability. Driven by the demand for AI applications, data centers are projected to consume a significant portion of US energy by 2028, putting stress on an already challenged power grid. The chapter emphasizes the importance of "fast" time-scale models to understand the dynamic interactions between data centers and the grid, especially given the rapid power fluctuations of AI workloads. It outlines a modeling framework that includes both offline and real-time EMT domain simulations, detailing the necessary representations for various components like utility interfaces, transformers, IT loads, UPS, cooling loads, Battery Energy Storage Systems (BESS), generators, protection systems, and higher-level control systems. While standard simulation tools like PSCAD offer basic models, custom development is often required to accurately capture the unique and fast-changing behaviors of modern data centers. The chapter also discusses key metrics and test cases for validating these models, focusing on transient load responses, protection relay coordination, and demand flexibility. Finally, it addresses the challenges of modeling large-scale data centers, such as computational complexity and the trade-off between model fidelity and practicality, suggesting hybrid modeling approaches as a solution. The overarching goal is to create a robust framework that helps assess data center impacts on grid stability, identify vulnerabilities, and inform the development of standards for reliable integration of these large loads into the bulk power system.

25 ENERGY STORAGE↗

Mechanism-Informed Breakdown: Understanding Degradation by Controlling Voltage-Hold Patterns in Proton Exchange Membrane Water Electrolyzers

Low catalyst loadings pose challenges to performance stability in proton exchange membrane (PEM) water electrolysis over extended operation. To study the impact of degradation mechanisms and voltage loss rates, different stress tests are applied to membrane electrode assemblies. Potential cycling conditions were observed to induce higher degrees of iridium (Ir) oxide crystallization, ionomer degradation, and catalyst layer (CL) thinning, which likely contributed to higher kinetic loss rates. On the other hand, while Ir migrating into the PEM (Ir band) generally impairs performance, the interconnected and more uniform Ir band formed under a constant 2 V hold may allow for Ir at the catalyst/membrane interface to remain electronically connected and kinetically accessible, as well as indicate greater Ir site access during the applied stressor. The 2 V hold also demonstrates improved kinetic durability through a lower Tafel slope, faster polarization kinetics, and reduced charge transfer resistance. In contrast, potential cycling caused the migration of disconnected Ir agglomerates into the membrane bulk and created a steady increase in charge transfer resistance, a more dramatic decrease in capacitance (46.7% loss), and significant damage to the surrounding ionomer, indicating a decline in both the quality and quantity of active sites in the anode CL. This work underscores the distinct degradation pathways associated with load holds versus cycling, highlighting the role of catalyst-ionomer interactions in kinetic performance and long-term stability. These insights can inform operational strategies for PEM electrolyzers powered by intermittent energy sources, aiming to minimize efficiency losses over extended operation.