Search NASA⌕ Search

SEARCH · Search NASA

Results for “STRESS MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

NEUTRON DIFFRACTION MEASUREMENT OF RESIDUAL STRESSES IN FRICTION STIR PROCESSED NANOCOMPOSITE SURFACE LAYER

Friction stir processing (FSP) was successfully used to stir and mix nano-sized Al2O3 particles into a Al6061-T6 aluminum plate to form a nanocomposite layer up to 3 mm thick. This nanocomposite surface has demonstrated significantly improved surface hardness, yield strength, and wear-resistance without sacrificing the substrate ductility and conductivity. Neutron diffraction analysis was conducted to determine the residual stress distribution in the nanocomposite surface layer. For comparison, the residual stress of the aluminum surface that was processed similarly but had no particle involved was also measured. Results showed that the macro-level residual stresses in the FSP zone without particles are low due to the annealing effect induced by the long heating time and large heat input. The macro-level residual stresses in the FSP-processed Al-Al2O3 nanocomposite zone are tensile up to 100 MPa in all three directions. The details of the results will be further discussed in the paper.

36 MATERIALS SCIENCE↗

Cement having stress-indicating properties

A system and method measures subterranean stress. The system and method includes a cement mixture that is mixed with water to set as a solid and a stress measuring-medium having piezospectroscopic properties that directly reveals stress in situ within the cement mixture in response to a photo stimulation. The stress measuring-medium combines with the cement mixture as a dry blend before being combined with water.

36 MATERIALS SCIENCE↗

Neutron diffraction measurement of residual stresses, dislocation density and texture in Zr-bonded U-10Mo “mini” fuel foils and plates

Here, Al clad U-10Mo fuel plates are being considered for conversion of several research reactors from high-enriched to low-enriched U fuel. Neutron diffraction measurements of the textures, residual phase stresses, and dislocation densities in the individual phases of the mini-foils throughout several processing steps and following hot-isostatic pressing to the Al cladding, have been completed. Recovery and recrystallization of the bare U-10Mo fuel foil, as indicated by the dislocation density and texture, are observed depending on the state of the material prior to annealing and the duration and temperature of the annealing process. In general, the cladding procedure significantly reduces the dislocation density, but the final state of the clad plate, both texture and dislocation density, depends strongly on the final processing step of the fuel foil. In contrast, the residual stress state of the final plate is dominated by the thermal expansion mismatch of the constituent materials.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Microstructure, texture, and residual stress in a friction stir processed AZ31B magnesium alloy

Spatial variations of microstructure, hardness, chemical composition, tensile behavior, texture and residual stresses were investigated in a friction-stir-processed (FSP) AZ31B magnesium alloy. The residual stresses were measured using two different methods: neutron diffraction and the contour method. No significant variations in the hardness and chemical compositions were found in the FSP zones, including the severely deformed stir zone (SZ), which showed a finer grain size compared to the heat-affected zone and base material. On the other hand, significant changes in the tensile yield strength, texture, and residual stresses were observed in the FSP zones. The relationship between the texture variations and yield strength reduction; and its influence on the decrease in the residual stress near the SZ is discussed. Finally, the residual stresses measured by neutron diffraction and the contour method are compared and the effect of the texture on neutron diffraction residual stress measurements is discussed.

36 MATERIALS SCIENCE↗

In situ measurement of velocity-stress sensitivity using crosswell continuous active-source seismic monitoring

The ability to characterize time-varying reservoir properties, such as the state of stress, has fundamental implications in subsurface engineering, relevant to geologic sequestration of CO 2 . Stress variation, here in the form of changes in pore fluid pressure, is one factor known to affect seismic velocity. Induced variations in velocity have been used in seismic studies to determine and monitor changes in the stress state. Previous studies conducted to determine velocity-stress sensitivity at reservoir conditions rely primarily on laboratory measurements of core samples or theoretical relationships. In this paper, we have developed a novel field-scale experiment designed to study the in situ relationship between pore-fluid pressure and seismic velocity using a crosswell continuous active-source seismic monitoring (CASSM) system. At the Cranfield, Mississippi, CO 2 sequestration field site, we actively monitored seismic response for five days with a temporal resolution of 5 min; the target was a 26 m thick injection zone at approximately 3.2 km depth in a fluvial sandstone formation (lower Tuscaloosa Formation). The variation of pore fluid pressure was obtained during discrete events of fluid withdrawal from one of the two wells and monitored with downhole pressure sensors. The results indicate a correlation between decreasing CASSM time delay (i.e., velocity change for a raypath in the reservoir) and periods of reduced fluid pore pressure. The correlation is interpreted as the velocity-stress sensitivity measured in the reservoir. This observation is consistent with published laboratory studies documenting a velocity ( V ) increase with an effective stress increase. A traveltime change ( d t ) of 0.036 ms is measured as the consequence of a change in pressure of approximately 2.55 MPa ( d P e ). For T = 13 ms total traveltime, the velocity-stress sensitivity is d V / V / d P e = d t / T / d P e = 10.9 × 10 - 4 / MPa . Finally, the overall results suggest that CASSM measurements represent a valid technique for in situ determination of velocity-stress sensitivity in field-scale monitoring studies.

58 GEOSCIENCES↗

Neutron Diffraction Measurement of Residual Stresses, Dislocation Density and Texture in Zr-bonded U-10Mo ''Mini'' Fuel Foils and Plates

Aluminum clad monolithic uranium 10 weight percent molybdenum (U-10Mo) fuel plates are being considered for conversion of several research and test nuclear reactors from high-enriched to low-enriched uranium fuel due to the inherently high density of fissile material. Comprehensive neutron diffraction measurements of the evolution of the textures, residual phase stresses, and dislocation densities in the individual phases of the mini-foils throughout several processing steps and following hot-isostatic pressing to the Al cladding, have been completed. Recovery and recrystallization of the bare U-10Mo fuel foil, as indicated by the dislocation density and texture, are observed depending on the state of the material prior to annealing and the duration and temperature of the annealing process. In general, the HIP procedure significantly reduces the dislocation density, but the final state of the clad plate, both texture and dislocation density, depends strongly on the final processing step of the fuel foil. In contrast, the residual stresses in the clad fuel plate do not depend strongly on the final processing step of the bare foil prior to HIP bonding. Rather, the residual stresses are dominated by the thermal expansion mismatch of the constituent materials of the fuel plate.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A combination of a Drickamer anvil apparatus and monochromatic X-rays for stress and strain measurements under high pressure

A modified Drickamer anvil apparatus has been developed to combine with monochromatic synchrotron radiation for high-pressure X-ray diffraction and radiography in the GSECARS bending-magnet station, 13-BM-D, at the Advanced Photon Source, Argonne, USA. Using this experimental set-up, deformation experiments can be carried out at pressures in excess of 30 GPa at high temperatures. Differential stresses and total axial strains of polycrystalline platinum and Mg{sub 2}SiO{sub 4} ringwoodite have been measured up to 32 GPa at room temperature using tungsten carbide anvils. The total axial strain of the platinum increases with pressure and reaches about 55% at the highest pressure. A test run using a composite sintered diamond anvil system was performed. The use of X-ray-tranparent anvils enables the entire Debye rings to be observed up to 10{sup o} 2{theta}. With high-energy photons (65-70 keV), this allows a coverage in Q (= 2{pi} sin{theta}/{lambda}) to about 3 {angstrom}{sup -1}, thus making it possible to evaluate hydrostatic pressure and differential stress in crystalline minerals using diffraction. This, coupled with the ability to determine axial strain, allows deformation studies to be performed to pressures above 30 GPa.

43 PARTICLE ACCELERATORS↗

Room temperature stress relaxation in nanocrystalline Ni measured by micropillar compression and miniature tension

In this report, we report a micropillar stress relaxation technique employing a stable displacement-controlled, in-situ scanning electron microscope indenter, and unusually large micropillars to precisely measure stress relaxation in electroplated nanocrystalline Ni thin films. The observed stress relaxation is significant under constant displacement: even well below the 0.2% offset yield strength, the stresses relax by ~4% within a minute; in the work hardening regime, stress relaxes by ~9% in 1 min. A logarithmic fit of the relaxation curves is consistent with an Arrhenius thermal activation of plasticity and suggests an activation volume in the vicinity of ~10 b 3 . The apparent and effective activation volumes diverge at lower strains, particularly in the “elastic” regime. These measurements are compared to similar measurements performed on free-standing thin film tensile coupons. Both methods yield similar results, thereby validating the applicability of pillar compression to capture time-dependent plasticity. To our knowledge, these are the first micropillar stress relaxation experiments on metals ever reported.

36 MATERIALS SCIENCE↗

Measurement of oxidative stress parameters using liquid chromatography-tandem mass spectroscopy (LC-MS/MS)

There is increasingly intense scientific and clinical interest in oxidative stress and the many parameters used to quantify the degree of oxidative stress. However, there remain many analytical limitations to currently available assays for oxidative stress markers. Recent improvements in software, hardware, and instrumentation design have made liquid chromatography and tandem mass spectroscopy (LC-MS/MS) methods optimal choices for the determination of many oxidative stress markers. In particular, LC-MS/MS often provides the advantages of higher specificity, higher sensitivity, and the capacity to determine multiple analytes (e.g. 4-11 oxidative stress markers per LC run) when compared to other available methods, such as gas chromatography-MS, immunoassays, spectrophotometric or flourometric assays. LC-MS/MS methods are also compatible with cleanup and sample preparation methods including prior solid phase extraction or automated two dimensional LC/LC chromatography followed by MS/MS. LC-MS/MS provides three analytical filtering functions: (1) the LC column provides initial separation as each analyte elutes from the column. (2) The first MS dimension isolates ions of a particular mass-to-charge (m/z) ratio. (3) The selected precursor ion is fragmented into product ions that provide structural information about the precursor ion. Quantitation is achieved based on the abundances of the product ions. The sensitivity limits for LC-MS/MS usually lie within the range of fg-pg of analyte per LC on-column injection. In this article, the present capabilities of LC-MS/MS are briefly presented and some specific examples of the strengths of these LC-MS/MS assays are discussed. The selected examples include methods for isoprostanes, oxidized proteins and amino acids, and DNA biomarkers of oxidative stress.

60 APPLIED LIFE SCIENCES↗

Measuring the residual stress and stress-corrosion cracking susceptibility of additively manufactured 316L by ASTM G36-94

Residual stress is a contributor to stress-corrosion cracking (SCC) and a common byproduct of additive manufacturing (AM). In this work, the relationship between residual stress and SCC susceptibility in laser powder bed fusion AM 316L stainless steel was studied through immersion in saturated boiling magnesium chloride per ASTM G36-94. The residual stress was varied by changing the sample height for the as-built condition and additionally by heat treatments at 600, 800, and 1200 °C to control, and in some cases reduce, residual stress. In general, all samples in the as-built condition showed susceptibility to SCC with the thinner, lower residual stress samples showing shallower cracks and crack propagation occurring perpendicular to melt tracks due to local residual stress fields. The heat-treated samples showed a reduction in residual stress for the 800 and 1200 °C samples. Both were free of cracks after >300 hours of immersion in MgCl 2 , while the 600 °C sample showed similar cracking to their as-built counterpart. Geometrically necessary dislocation (GND) density analysis indicates that the dislocation density may play a major role in the SCC susceptibility.

36 MATERIALS SCIENCE↗

Apparatus for pre-stress-straining rod-type specimens in tension for in-situ passive fracture testing

A stress-strain testing apparatus imposes a stress-strain on a specimen while disposed in a controlled environment. Each end of the specimen is fastened to an end cap and a strain gage is attached to the specimen. An adjusting mechanism and a compression element are disposed between the end caps forming a frame for applying forces to the end caps and thereby stress-straining the specimen. The adjusting mechanism may be extended or retracted to increase or decrease the imposed stress-strain on the specimen, and the stress-strain is measured by the strain gage on the specimen while the apparatus is exposed to an environment such as high pressure hydrogen. Strain gages may be placed on the frame to measure stress-strains in the frame that may be caused by the environment.

42 ENGINEERING↗