Search NASA⌕ Search

SEARCH · Search NASA

Results for “STRESS RELAXATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

MWm-array sensors for in situ monitoring of high-temperature components in power plants

Utilization of America's substantial coal reserves for energy production has become a national priority. Advanced coal-fired power plants offer an environmentally friendly means to achieve that goal. These power plants, such as ultrasupercritical power plants, will provide high thermal efficiency along with greatly reduced emissions of CO and other pollutants. Life cycle costs for the advanced coal-fired plants can be reduced by enhanced observability in support of condition-based maintenance. The enhanced observability can be achieved by using networks of condition-monitoring sensors that would provide component-level material condition information and through-wall temperature monitoring. This would reduce uncertainties in knowledge of material condition, at the level of individual components, and improve capability to predict remaining life of critical components. One approach being developed under the U.S. Department of Energy Small Business Innovation Research Program is to develop and implement high-temperature versions of the meandering winding magnetometer (HT-MWM) for temperatures up to 1000{sup o}C. These patented sensors, coupled with multivariate inverse methods, would provide superior performance for in situ material condition monitoring (material degradation, flaw detection, stress relaxation, and/or creep monitoring) and through-wall temperature measurement. Networks of HT-MWMs will generate material condition information to be used by adaptive life-management algorithms for remaining life prediction and decision support.

20 FOSSIL-FUELED POWER PLANTS↗

Assessing the accuracy of time-fraction and ductility exhaustion approaches for creep-fatigue damage prediction through feature-test validation

Determining creep-fatigue damage formation is critical for elevated temperature components integrity. This study evaluates creep-fatigue assessments with emphasis on differences between creep damage models. Evaluated are the time-fraction model and the classical and stress-modified ductility exhaustion creep damage models. This work extends the domain of stress-modified ductility exhaustion models by introducing and validating such formalism to Ni-based alloys. The fidelity of the assessments was benchmarked against uniaxial creep-fatigue and multiaxial feature tests of Alloy 617. For uniaxial specimens, best estimate predictions rank ductility exhaustion as the most accurate and precise and time-fraction as markedly conservative. For feature tests, ductility exhaustion predictions are within < 4.0 times difference, whereas time-fraction underpredicts life by factors of 7–14. The observations suggest ductility exhaustion models as alternative to time-fraction models in design codes for situations requiring characterization of the design margin. Further work in employing such models to assess other relevant phenomena (e.g., stress relaxation cracking) is discussed.

creep-fatigue↗

Design by analysis rules for ASME Section III, Division 5, Class B components

The current rules for elevated temperature ASME Section III, Division 5, Class B components, other than piping, were basically adapted from the Design-by-Rule approach for Section VIII, Division 1 vessels. A goal of the proposed new rules is to explicitly account for the design life and cyclic service while recognizing the less-rigorous requirements commensurate with lesser safety consideration. Further goals are to maximize the use of modern computational technology, for example finite element analysis in conjunction with reference stress concepts, and to avoid the need for stress classification. This paper summarizes the work done to address these issues. A summary of the design-by-analysis for primary loads, strain limit evaluation, and creep-fatigue damage assessment is presented. The proposed design-by-analysis creep-fatigue damage calculation approach uses a new elastic follow-up-based Isochronous Stress Strain Curve stress relaxation procedure. A set of sample problems are selected to validate the proposed design-by-analysis rules for creep-fatigue damage assessment. The proposed Class B rules are evaluated against the Class A elastic design rules and the experimental data obtained from a family of a simplified model test-based key-feature test results. The proposed Class B creep-fatigue damage assessment methodology yields conservative design cycles estimates compared to the experimental results.

36 MATERIALS SCIENCE↗

Thixotropy, antithixotropy, and viscoelasticity in hysteresis

Thixotropy, antithixotropy, and viscoelasticity are three types of time-dependent dynamics that involve fundamentally different underlying physical processes. Here, we show that the three dynamics exhibit different signatures in hysteresis by examining the fingerprints of the simplest thixotropic kinetic model, a new antithixotropic model that we introduce here, and the Giesekus model. We start by showing that a consistent protocol to generate hysteresis loops is a discrete shear-rate controlled ramp that begins and ends at high shear rates, rather than at low shear rates. Using this protocol, we identify two distinguishing features in the resulting stress versus shear rate loops. The first is the direction of the hysteresis loops: clockwise for thixotropy, but counterclockwise for viscoelasticity and antithixotropy. A second feature is achieved at high ramping rates where all responses lose hysteresis: the viscoelastic response shows a stress plateau at low shear rates due to lack of stress relaxation, whereas the thixotropic and antithixotropic responses are purely viscous with minimal shear thinning or thickening. We establish further evidence for these signatures by experimentally measuring the hysteresis of Laponite suspensions, carbon black suspensions, and poly(ethylene oxide) solutions, each representing a historically accepted example of each class of material behavior. The signatures measured in experiments are consistent with those predicted by the three models. This study reveals different fingerprints in hysteresis loops associated with thixotropy, antithixotropy, and viscoelasticity, which may be helpful in distinguishing the three time-dependent responses.

Mechanics↗

Dynamics in entangled polyethylene melts [Multi time scale dynamics in entangled polyethylene melts]

Polymer dynamics creates distinctive viscoelastic behavior as a result of a coupled interplay of motion at the atomic length scale and motion of the entire macromolecule. Capturing the broad time and length scales of polymeric motion however, remains a challenge. Using linear polyethylene as a model system, we probe the effects of the degree of coarse graining on polymer dynamics. Coarse-grained (CG) potentials are derived using iterative Boltzmann inversion with λ methylene groups per CG bead (denoted CGλ) with λ = 2,3,4 and 6 from a fully-atomistic polyethylene melt simulation. By rescaling time in the CG models by a factor α, the chain mobility for the atomistic and CG models match. We show that independent of the degree of coarse graining, all measured static and dynamic properties are essentially the same once the dynamic scaling factor α and a non-crossing constraint for the CG6 model are included. The speedup of the CG4 model is about 3 times that of the CG3 model and is comparable to that of the CG6 model. Furthermore, using these CG models we were able to reach times of over 500 μs, allowing us to measure a number of quantities, including the stress relaxation function, plateau modulus and shear viscosity, and compare directly to experiment.

36 MATERIALS SCIENCE↗

TEC (ThermoElastoCreep) [SWR-25-167]

This repository provides a Python script to simulate the thermomechanical behavior of Concentrating Solar Power (CSP) receivers under periodic thermal loading. The simulation couples elastic and creep strains to predict stress relaxation, fatigue, and rupture life of the receiver structure. The work was done under the project Light Trapping Planar Cavity Receiver (LTPCR) funded by U.S. Department of Energy. All other relevant work and publications from LTPCR project can be found at https://github.com/NatLabRockies/LTPCR-Public

He, Xin [National Laboratory of the Rockies (NLR),↗

EGS Collab Experiment 1: In-situ observation of pre-, co- and post-seismic shear slip preceding hydraulic fracturing

Understanding the initiation and arrest of earthquakes is one of the long-standing challenges of seismology. Here we report on direct observations of borehole displacement by a meter-sized shear rupture induced by pressurization of metamorphic rock at 1.5 km depth. We observed the acceleration of sliding, followed by fast co-seismic slip and a transient afterslip phase. Total displacements were about 7, 5.5 and 9.5 micrometers, respectively for the observed pre-slip, co-seismic slip and afterslip. The observed pre-slip lasted about 0.4 seconds. Co-seismic slip was recorded by the 1 kHz displacement recording and a 12-component array of 3-C accelerometers sampled at 100 kHz. The observed afterslip is consistent with analytical models of arrest in a velocity-strengthening region and subsequent stress relaxation. The observed slip vector agrees with the activation of a bedding plane within the phyllite, which is corroborated by relocated seismic events that were observed during the later stages of the injection experiment. This submission includes the pressure and deformation data recorded by the SIMFIP probe during the first injection at the 164 ft (50 m) notch of borehole E1-I. The injection was performed on on 05/22/2018 as part of Experiment 1 of the EGS Collab project. This data accompanies a manuscript submitted to GRL, linked in this submission.

15 GEOTHERMAL ENERGY↗

Linear viscoelastic measurements of commerical therapy putties for design and intuition

This dataset complements the publication Mapping Linear Viscoelasticity for Design and Tactile Intuition (Corman & Ewoldt, 2019). It contains rigorous shear rheometry measurements for six commercial silicone putties, including creep recovery, SAOS, LAOS, and stress relaxation. Additional, unpublished data was generated as part of a graduate rheology course taught by Randy Ewoldt at University of Illinois Urbana-Champaign. Together, these datasets provide a comprehensive example of linear viscoelasticity of a commercial material. The collection is intended both as a pedagogical resource for developing physical intuition in linear viscoelasticity and as a reference dataset for data interpretation, model fitting, and comparative rheological analysis.

C. Marsh, Maxwell↗

FIFTH INTERIM STATUS REPORT: MODEL 9975 PCV O-RING FIXTURE LONG-TERM LEAK PERFORMANCE

A series of experiments to monitor the aging performance of Viton{sup reg.} GLT O-rings used in the Model 9975 package has been ongoing for six years at the Savannah River National Laboratory. Sixty-seven mock-ups of 9975 Primary Containment Vessels (PCVs) were assembled and heated to temperatures ranging from 200 to 450 F. They were leak-tested initially and have been tested at nominal six month intervals to determine if they meet the criterion of leaktightness defined in ANSI standard N14.5-97. Fourteen additional tests were initiated in 2008 with GLT-S O-rings heated to temperatures ranging from 200 to 400 F. High temperature aging continues for 36 GLT O-ring fixtures at 200--350 F. Room temperature leak test failures have been experienced in 5 of the GLT O-ring fixtures aging at 300 and 350 F, and in all 3 of the GLT O-ring fixtures aging at higher temperatures. No failures have yet been observed in GLT O-ring fixtures aging at 200 F for 30--48 months, which is still bounding to O-ring temperatures during storage in KAMS. High temperature aging continues for 6 GLT-S O-ring fixtures at 200--300 F. Room temperature leak test failures have been experienced in all 8 of the GLT-S O-ring fixtures aging at 350 and 400 F. No failures have yet been observed in GLT-S O-ring fixtures aging at 200 or 300 F for 19 months. For O-ring fixtures that have failed the room temperature leak test and been disassembled, the O-rings displayed a compression set ranging from 51--95%. This is significantly greater than seen to date for packages inspected during KAMS field surveillance (23% average). For GLT O-rings, service life based on the room temperature leak rate criterion is comparable to that predicted by compression stress relaxation (CSR) data at higher temperatures (350--400 F). While there are no comparable failure data yet at aging temperatures below 300 F, extrapolations of the data for GLT O-rings suggests that CSR model predictions provide a conservative prediction of service life relative to the leak rate criterion. Failure data at lower temperatures is needed to verify this apparent trend. Insufficient failure data exist currently to perform a similar comparison for GLT-S O-rings. Aging and periodic leak testing will continue for the remaining fixtures.

42 ENGINEERING↗

Model 9975 PCV O-Ring Fixture Long-Term Leak Performance (Seventh Interim Status Report)

A series of experiments to monitor the aging performance of Viton® GLT O-rings used in the Model 9975 package has been ongoing since 2004 at the Savannah River National Laboratory. Seventy tests using mock-ups of 9975 Primary Containment Vessels (PCVs) were assembled and heated to temperatures ranging from 200 to 450ºF. They were leak-tested initially and have been tested periodically to determine if they meet the criterion of leak-tightness defined in ANSI standard N14.5-97. Fourteen additional tests were initiated in 2008 with GLT-S O-rings heated to temperatures ranging from 200 to 400ºF. High temperature aging continues for 23 GLT O-ring fixtures at 200–270ºF. Room temperature leak test failures have been experienced in all of the GLT O-ring fixtures aging at 350ºF and higher temperatures, and in 8 fixtures aging at 300ºF. The remaining GLT O-ring fixtures aging at 300ºF have been retired from testing following more than 5 years at temperature without failure. No failures have yet been observed in GLT O-ring fixtures aging at 200ºF for 54-72 months, which is still bounding to O-ring temperatures during storage in K-Area Complex (KAC). Based on expectations that the fixtures aging at 200ºF will remain leak-tight for a significant period yet to come, 2 additional fixtures began aging in 2011 at an intermediate temperature of 270ºF, with hopes that they may reach a failure condition before the 200ºF fixtures. High temperature aging continues for 6 GLT-S O-ring fixtures at 200–300ºF. Room temperature leak test failures have been experienced in all 8 of the GLT-S O-ring fixtures aging at 350 and 400ºF. No failures have yet been observed in GLT-S O-ring fixtures aging at 200-300ºF for 30-36 months. For O-ring fixtures that have failed the room temperature leak test and been disassembled, the O-rings displayed a compression set ranging from 51–96%. This is greater than seen to date for any packages inspected during KAC field surveillance (24% average). For GLT O-rings, separate service life estimates have been made based on the O-ring fixture leak test data and based on compression stress relaxation (CSR) data. These two predictive models show reasonable agreement at higher temperatures (350–400ºF). However, at 300ºF, the room temperature leak test failures to date experienced longer aging times than predicted by the CSR-based model. This suggests that extrapolations of the CSR model predictions to temperatures below 300ºF will provide a conservative prediction of service life relative to the leak rate criterion. Leak test failure data at lower temperatures are needed to verify this apparent trend. Insufficient failure data exist currently to perform a similar comparison for GLT-S O-rings. Aging and periodic leak testing will continue for the remaining PCV O-ring fixtures.

36 MATERIALS SCIENCE↗

NINTH INTERIM STATUS REPORT: MODEL 9975 PCV O-RING FIXTURE LONG-TERM LEAK PERFORMANCE

A series of experiments to monitor the aging performance of Viton® GLT O-rings used in the Model 9975 package has been ongoing since 2004 at the Savannah River National Laboratory. One approach has been to periodically evaluate the leak performance of O-rings being aged in mock-up 9975 Primary Containment Vessels (PCVs) at elevated temperatures. Other methods such as compression-stress relaxation (CSR) tests and field surveillance are also on-going to evaluate O-ring behavior. Seventy tests using PCV mock-ups were assembled and heated to temperatures ranging from 200 to 450 ºF. They were leak-tested initially and have been tested periodically to determine if they continue to meet the leak-tightness criterion defined in ANSI standard N14.5-97. Due to material substitution, fourteen additional tests were initiated in 2008 with GLT-S O-rings heated to temperatures ranging from 200 to 400 ºF. High temperature aging continues for 23 GLT O-ring fixtures at 200 – 270 ºF. Room temperature leak test failures have been experienced in all of the GLT O-ring fixtures aging at 350 ºF and higher temperatures, and in 8 fixtures aging at 300 ºF. The earliest 300 °F GLT O-ring fixture failure was observed at 34 months. The remaining GLT O-ring fixtures aging at 300 ºF have been retired from testing following more than 5 years at temperature without failure. No failures have yet been observed in GLT O-ring fixtures aging at 200 ºF for 72 - 96 months, which bounds O-ring temperatures anticipated during storage in K-Area Complex (KAC). Based on expectations that the 200 ºF fixtures will remain leak-tight for a significant period yet to come, 2 additional fixtures began aging in 2011 at 270 ºF, with hopes that they may reach a failure condition before the 200 ºF fixtures, thus providing additional time to failure data. High temperature aging continues for 6 GLT-S O-ring fixtures at 200 – 300 ºF. Room temperature leak test failures have been experienced in all 8 of the GLT-S O-ring fixtures aging at 350 and 400 ºF. No failures have yet been observed in GLT-S O-ring fixtures aging at 200 - 300 ºF for 54 - 57 months. No additional O-ring failures have been observed since the last interim report was issued. Aging and periodic leak testing will continue for the remaining PCV fixtures. Additional irradiation of several fixtures is recommended to maintain a balance between thermal and radiation exposures similar to that experienced in storage, and to show the degree of consistency of radiation response between GLT and GLT-S O-rings.

42 ENGINEERING↗

Tenth Interim Status Report: Model 9975 O-Ring Fixture Long-Term Leak Performance

A series of experiments to monitor the aging performance of Viton ® GLT O-rings used in the Model 9975 package has been ongoing since 2004 at the Savannah River National Laboratory. One approach has been to periodically evaluate the leak performance of O-rings being aged in mock-up 9975 Primary Containment Vessels (PCVs) at elevated temperatures. Other methods such as compression-stress relaxation (CSR) tests and field surveillance are also on-going to evaluate O-ring behavior. Seventy tests using PCV mock-ups were assembled and heated to temperatures ranging from 200 to 450 °F. They were leak-tested initially and have been tested periodically to determine if they continue to meet the leak-tightness criterion defined in ANSI standard N14.5-97. Due to material substitution, fourteen additional tests were initiated in 2008 with GLT-S O-rings heated to temperatures ranging from 200 to 400 °F.

42 ENGINEERING↗

Model 9975 O-Ring Fixture Long-Term Leak Performance (Tenth Interim Status Report)

A series of experiments to monitor the aging performance of Viton® GLT O-rings used in the Model 9975 package has been ongoing since 2004 at the Savannah River National Laboratory. One approach has been to periodically evaluate the leak performance of O-rings being aged in mock-up 9975 Primary Containment Vessels (PCVs) at elevated temperatures. Other methods such as compression-stress relaxation (CSR) tests and field surveillance are also on-going to evaluate O-ring behavior. Seventy tests using PCV mock-ups were assembled and heated to temperatures ranging from 200 to 450 ºF. They were leak-tested initially and have been tested periodically to determine if they continue to meet the leak-tightness criterion defined in ANSI standard N14.5-97. Due to material substitution, fourteen additional tests were initiated in 2008 with GLT-S O-rings heated to temperatures ranging from 200 to 400 ºF. High temperature aging continues for 23 GLT O-ring fixtures at 200 – 270 ºF. Room temperature leak test failures have been experienced in all of the GLT O-ring fixtures aging at 350 ºF and higher temperatures, and in 8 fixtures aging at 300 ºF. The earliest 300 °F GLT Oring fixture failure was observed at 34 months. The remaining GLT O-ring fixtures aging at 300 ºF have been retired from testing following more than 5 years at temperature without failure. No failures have yet been observed in GLT O-ring fixtures aging at 200 ºF for 84 - 108 months, which bounds O-ring temperatures anticipated during storage in K-Area Complex (KAC). Based on expectations that the 200 ºF fixtures will remain leak-tight for a significant period yet to come, 2 additional fixtures began aging in 2011 at 270 ºF, with hopes that they may reach a failure condition before the 200 ºF fixtures, thus providing additional time to failure data. High temperature aging continues for 5 GLT-S O-ring fixtures at 200 – 300 ºF. Room temperature leak test failures have been experienced in all 8 of the GLT-S O-ring fixtures aging at 350 and 400 ºF, and in one GLT-S O-ring fixture aging at 300 ºF. No failures have yet been observed in GLT-S O-ring fixtures aging at 200 - 250 ºF for 66 months. One O-ring fixture has failed since the last interim report was issued. Both O-rings in one GLTS fixture aging at 300 ºF failed to remain leak-tight after 69 months at temperature. Aging and periodic leak testing will continue for the remaining PCV fixtures. Additional irradiation of several fixtures has been performed in the last year to maintain a balance between thermal and radiation exposures similar to that experienced in storage, and to show the degree of consistency of radiation response between GLT and GLT-S O-rings.

42 ENGINEERING↗

Analysis of Cavern and Well Stability at the West Hackberry SPR Site Using a Full-Dome Model

This report presents computational analyses that simulate the structural response of caverns at the Strategic Petroleum Reserve (SPR) West Hackberry site. The cavern field comprises 22 caverns. Five caverns (6, 7, 8, 9, 11) were acquired from industry and have unusual shapes and a history dating back to 1946. The other 17 caverns (101-117) were leached according to SPR standards in the mid-1980s and have tall cylindrical shapes. The history of the caverns and their shapes are simulated in a three-dimensional geomechanics model of the site that predicts deformations, strains, and stresses. Future leaching scenarios corresponding to oil drawdowns using fresh water are also simulated by increasing the volume of the caverns. Cavern pressures are varied in the model to capture operational practices in the field. The results of the finite element model are interpreted to provide information on the current and future status of subsidence, well integrity, and cavern stability. The most significant results in this report are relevant to Cavern 6. The cavern is shaped like a bowl with a large ceiling span and is in close proximity to Cavern 9. The analyses predict tensile stresses at the edge of the ceiling during repressurization of Cavern 6 following workover conditions. During a workover the cavern is at low pressure to service a well. The wellhead pressures are atmospheric. When the workover is complete, the cavern is repressurized. The resulting elastic stresses are sufficient to cause tension around the edge of the large ceiling span. With time, these stresses relax to a compressive state because of salt creep. However, the potential for salt fracture and propagation exists, particularly towards Cavern 9. With only 200 feet of salt between the caverns, the operational consequences must be examined if the two caverns become connected. A critical time may be during a workover of Cavern 9 in part because of the operational vulnerabilities, but also because dilatant damage is predicted under the ledge that forms the lower lobe in the cavern. The remaining caverns have no significant issues regarding cavern stability and may be safely enlarged during subsequent oil drawdowns. Predicted well strains and subsidence are significant and consequently future remedial actions may be necessary. These predicted well strains certainly suggest appropriate monitoring through a well-logging program. Subsidence is currently being monitored.

02 PETROLEUM↗

Final Report: In-Situ TEM Observations of Degradation Mechanisms in Next-Generation High-Energy Density Lithium-Ion Battery Systems

This project originally sought to characterize nanoscale processes associated with the degradation of next-generation high energy density lithium-ion battery electrodes via in-situ transmission electron microscopy (TEM). The research also focused on developing the experimental techniques necessary for investigating electrochemical systems by in-situ transmission electron microscopy and providing a framework for understanding and quantifying electron beam effects that influence experimental results. In line with these goals, this project demonstrated and published the first in-situ TEM cycling of a Li-ion battery electrode in commercially relevant non-aqueous electrolyte: a technique subsequently adopted by a number of researchers in the field. Experiments performed on Sn anodes, demonstrated porosity evolution during Li dealloying as a mechanism for strain accommodation during the first cycle, and observed partially reversible crystalline to amorphous phase transitions associated with Li insertion and extraction in subsequent cycles. Complementary study of in-situ dealloying in a simple model, Au-Cu, was also performed. We also published the earliest quantitative measurements of electron beam effects in aqueous and non-aqueous liquids. Specifically, we utilized a model system to quantify the fraction of incident electron beam that contributed to charge transfer mediated reactions in non-aqueous liquid, since such liquids are primarily dose sensitive. We also quantified the evolution of model aqueous chemistries as a function of dose rate and chemical potential to better understand the reaction mechanisms active in liquids exposed to electron beams. The original project goals included the use of controlled environments to simulate different battery operational conditions. To aid such experiments, we developed new experimental apparatuses and techniques to perform in-situ liquid cell TEM under controlled temperature, including heating and cooling. We demonstrated this capability in aqueous systems; specifically understanding phase selection and solid-liquid interface interactions with particles during water crystallization and hydrothermal precipitation kinetics of ZnO. We also published the first demonstration of in-situ TEM based high-field (plasma) experiments and in-situ TEM of aqueous photochemistry, which demonstrated an previously unrecognized early growth mode transition during Au sputtering and delocalization of gas bubble nucleation during water splitting, respectively. In addition to the scientific results, this portion of the project greatly expanded the range of systems that can be characterized in realistic environments at the nanoscale via in-situ TEM. Unfortunately, commercial battery electrolytes are quite sensitive to electron dose. This limits the time of acquisition and/or the spatial resolution of the experiments. The same problem has been encountered in all subsequent publications in the field. The major problem, relative to the project original goals, is that long term cycling is challenging to characterize and the desired high resolution or analytical capabilities are limited. In line with our original goals to characterize battery reaction and degradation mechanisms under controlled electrochemical cycling, we developed a completely new type of Li-ion electrochemical cell that has been useful for both structural and analytical characterization. To date, we have demonstrated this platform for in-situ cycling of Li-ion batteries during scanning electron microscopy (SEM), Auger electron spectroscopy (AES), and x-ray photoelectron spectroscopy (XPS). In-situ AES has been found to be a quite powerful tool to characterize the chemical evolution of Li-ion batteries cycled in-situ and much of our effort in the final project period has focused on charactering Li-ion cathodes using the technique. We utilized in-situ SEM to propose a new mechanism for Li whisker/dendrite formation and show the importance of diffusion mediated stress relaxation in fracture of Sn anode particles. A combination of in-situ XPS and AES was used to clarify the CuO anode reaction mechanism. In the final project period, we have gained new insights into surface reactions occurring on cathodes at high voltage using in-situ AES. Specifically, we have discovered that many of the SEI formation reactions typically attributed to electrolyte decomposition are actually more fundamental to the electrode material surface thermodynamics in the presence of an arbitrary carbon source. These insights greatly affect how we understand and control surface degradation induced capacity fade at cathodes. Finally, we have made some effort to apply this novel in-situ platform to TEM characterization and believe this is a fruitful avenue for future research.

25 ENERGY STORAGE↗

Open stack thermal battery tests

We present selected results from a series of Open Stack thermal battery tests performed in FY14 and FY15 and discuss our findings. These tests were meant to provide validation data for the comprehensive thermal battery simulation tools currently under development in Sierra/Aria under known conditions compared with as-manufactured batteries. We are able to satisfy this original objective in the present study for some test conditions. Measurements from each test include: nominal stack pressure (axial stress) vs. time in the cold state and during battery ignition, battery voltage vs. time against a prescribed current draw with periodic pulses, and images transverse to the battery axis from which cell displacements are computed. Six battery configurations were evaluated: 3, 5, and 10 cell stacks sandwiched between 4 layers of the materials used for axial thermal insulation, either Fiberfrax Board or MinK. In addition to the results from 3, 5, and 10 cell stacks with either in-line Fiberfrax Board or MinK insulation, a series of cell-free “control” tests were performed that show the inherent settling and stress relaxation based on the interaction between the insulation and heat pellets alone.

25 ENERGY STORAGE↗

FY2018 Status Report: Model 9975 O-Ring Fixture Long-Term Leak Performance

A series of experiments to monitor the aging performance of Viton® GLT and GLT-S O-rings used in the Model 9975 shipping package has been ongoing since 2004 at the Savannah River National Laboratory. One approach has been to periodically evaluate the leak performance of O-rings being aged in mock-up 9975 Primary Containment Vessels (PCVs) at elevated temperature. Other methods such as compression stress-relaxation (CSR) tests and field surveillance are also on going to evaluate O-ring behavior. Seventy tests using PCV mock-ups with GLT O-rings were assembled and heated to temperatures ranging from 200 to 450 ºF. They were leak-tested initially and have been tested periodically to determine if they continue to meet the leak-tightness criterion defined in ANSI standard N14.5-97. Due to material substitution, a smaller test matrix with fourteen additional tests was initiated in 2008 with GLT-S O-rings heated to temperatures ranging from 200 to 400 ºF.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗