Search NASA⌕ Search

SEARCH · Search NASA

Results for “Saturation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

DC-Saturated Continuously Variable Series Reactors (CVSRs) for Power Flow Control in Power Transmission Systems

This paper proposes a novel continuously variable series reactor (CVSR) based on a dc current controller (DCC) to manage power flow in transmission systems. There are three major contributions. First, the three-dimensional electromagnetic interaction has been comprehensively analyzed to extend the understanding beyond the conventional 2D relationship. Second, a high-fidelity reluctance model of the CVSR with an improved DCC model is proposed and implemented. To overcome the fundamental concern for the system modeling, the DCC has been modeled as an ideal current source in parallel with an output impedance. Additionally, the induced back-EMF can be precisely projected which provides critical design guidelines for the DCC. Third, inspired by the theoretical analysis and modeling, a reliable high power DCC converter is designed accordingly to interface with kV-level back-EMF and supply kA-level dc current for a 115 kV/1500 A CVSR. Experiments are conducted in a practical transmission demonstration system. When the ac current in the transmission system varies from zero to 1500 A, experimental results show that the proposed CVSR can continuously regulate the reactance from 1.6 Ω to 5 Ω, validating the effectiveness of the proposed system design and modeling methodology.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Development of Saturated Zone Three-Dimensional Initial Condition Plumes for the Composite Analysis and Cumulative Impacts Evaluation Modeling

The purpose of this environmental calculation file (ECF) is to document and present the methodology, input data, and results of extending two-dimensional (2-D) plume depictions documented in DOE/RL- 2017-66, Hanford Site Groundwater Monitoring for 2017, into three dimensions (3-D) for select contaminants of interest (COIs) in the 200-BP-5, 200-UP-1, 200-ZP-1, and 200-PO-1 Groundwater Operable Units at the Hanford Site. Plumes with sufficient available vertical profile data were interpolated in 3-D using the Leapfrog Geo®1 geologic modeling platform, which includes an interpolation engine for analyzing and visualizing 3-D data. Results of these interpolations are intended for use in developing inputs for transport modeling to support forecasts of Central Plateau contaminant plume fate and transport.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Predictive Flow Simulation with the P2R Model for the 200-IA-1 Preliminary Remediation Goal Saturated Zone Abstraction

In order to develop and evaluate alternatives for remediation of waste sites constituting the 200-IA-1 Operable Unit (OU), a focused feasibility study (FFS) is currently underway. The 200-IA-1 OU FFS requires preliminary remediation goals (PRGs) protective of groundwater be evaluated which includes estimates of fate and transport of contaminants in the groundwater from multiple sources within the Central Plateau Inner Area. This document details the application of the Plateau-to-River (P2R) Model version 8.3 to predict the flow of groundwater on the Central Plateau for the 10,000-year simulation to support the 200-IA-1 OU PRG calculation. The simulated flow field will support the simulation of fate and transport of contaminants for use in estimating peak unit-length concentration as part of the 200-IA-1 OU PRG calculation presented in a separate environmental calculation file (ECF) (ECF-200IA1-20-0108, Determination of Preliminary Remediation Goals for 200-IA-1 Source Operable Unit).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hanford Composite Analysis Special Studies FY2025 - Groundwater Flow Simulation for use in a Comparison of Simulated Concentrations in the Saturated Zone Estimated by the Plateau-to-River Model Versions 8.3 and 9.1

In order to meet the requirements of U.S. Department of Energy (DOE) in DOE O 435.1, Radioactive Waste Management, a composite analysis (CA) must be completed for the Central Plateau at the Hanford Site. The CA requires estimates of fate and transport of radionuclides in the groundwater from multiple sources within the modeling domain. This Environmental Calculation File (ECF) details the application of the Plateau-to-River (P2R) Model (CP-57037, Rev. 3, Model Package Report for the P2R Model: Version 9.1) to predict the flow of groundwater on the Central Plateau for the 10,000-year simulation to support a special analysis associated with the Hanford Site CA. The simulated flow field will support the simulation of fate and transport of contaminants for comparison to the results obtained as part of the CA to evaluate impact of the updated version of the P2R Model.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A bicarbonate-rich liquid condensed phase in non-saturated solutions in the absence of divalent cations

Bicarbonate (HCO 3 - ) and sodium (Na + )-containing solutions contain droplets of a separate, bicarbonate-rich liquid condensed phase (LCP) that have higher concentrations of HCO 3 - relative to the bulk solution in which they reside. The existence and composition of the LCP droplets has been investigated by nanoparticle tracking analysis, nuclear magnetic resonance spectroscopy, refractive index measurements and X-ray pair distribution function analysis. The bicarbonate-rich LCP species is a previously unaccounted-for, ionic phenomenon which occurs even in solutions with solely monovalent cations. Its existence requires re-evaluation of models used to describe and model aqueous solution physicochemistry, especially those used to describe and model carbonate mineral formation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The role of stress and fluid saturation on the acoustic response of fractured rock

Standard rock physics models are formulated to describe the behavior of porous sedimentary reservoirs, with clean sandstones being the archetypal system; however, many situations demand geophysical monitoring of rocks with significantly different structures, such as low porosity, fractured reservoirs. Conventional models also suggest that these “stiff” reservoirs can be challenging to monitor seismically due to small fluid substitution effects, but the presence of fractures leads to stress dependence which may be leveraged for remote monitoring purposes. Using samples from the Duperow Formation (dolostone) obtained from the Danielson test well in Kevin Dome, MT, we conducted ultrasonic and multi-scale structural (profilometry, synchrotron micro-tomography, pressure sensitive film) measurements on naturally fractured core in order to characterize the effects of fluid substitution and effective stress on the acoustic response of fractured reservoir rock with a focus in particular on the textural and seismic characteristics of natural fractures. We find that changes in effective stress can yield changes in velocity of up to 20% and changes in attenuation up to 200%. Measured fluid substitution effects are resolvable, but stress effects dominate. These measurements provide insight into the physical processes controlling acoustic response of fractured rocks in general and can also be used to inform monitoring efforts in fractured reservoirs.

58 GEOSCIENCES↗

Assessing the Oxidative Stability of Anion Exchange Membranes in Oxygen Saturated Aqueous Alkaline Solutions

While anion exchange membrane water electrolyzers show promise as a source of green hydrogen using low-temperatures and non-platinum group metal catalysts, many concerns must be addressed. A primary challenge for the development of high-performance anion exchange membrane water electrolyzers is the fabrication of a stable membrane that will be able to survive long-term stability test while maintaining high anion conductivity, which is a necessity for a durable water electrolyzer. This method will present a standardized protocol that can be used by researchers to assess the quality of their AEM materials and be able to provide insight into how materials may be degrading and how to improve the quality of AEMs. Using Mohr or Volhard titration to measure ion-exchange capacity, EIS to determine the ionic conductivity, NMR and FTIR to understand the extent of membrane degradation over time, and mechanical analyzers to determine the strength of their AEMs, this standardized protocol will guide researchers to determining and improving upon the long-term durability and performance of their AEM materials.

36 MATERIALS SCIENCE↗

The Effect of Acetylation on Iron Uptake and Diffusion in Water Saturated Wood Cell Walls and Implications for Decay

Acetylation is widely used as a wood modification process that protects wood from fungal decay. The mechanisms by which acetylation protects wood are not fully understood. With these experiments, we expand upon the literature and test whether previously observed differences in iron uptake by wood were a result of decreased iron binding capacity or slower diffusion. We measured the concentration of iron in 2 mm thick wood sections at 0, 10, and 20% acetylation as a function of time after exposure to iron solutions. The iron was introduced either strongly chelated with oxalate or weakly chelated with acetate. The concentrations of iron and oxalate in solution were chosen to be similar to those found during brown rot decay, while the concentration of iron and acetate matched previous work. The iron content of oxalate-exposed wood increased only slightly and was complete within an hour, suggesting little absorption and fast diffusion, or only slight surface adsorption. The increase in iron concentration from acetate solutions with time was consistent with Fickian diffusion, with a diffusion coefficient on the order of 10 -16 m 2 s -1 . The rather slow diffusion rate was likely due to significant binding of iron within the wood cell wall. The diffusion coefficient did not depend on the acetylation level; however, the capacity for iron absorption from acetate solution was greatly reduced in the acetylated wood, likely due to the loss of OH groups. We explored several hypotheses that might explain why the diffusion rate appears to be independent of the acetylation level and found none of them convincing. Implications for brown rot decay mechanisms and future research are discussed.

54 ENVIRONMENTAL SCIENCES↗