Search NASA⌕ Search

SEARCH · Search NASA

Results for “Scanning techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Impacts of Curing-Induced Phase Segregation in Silicon Nanoparticle-Based Electrodes

We report the investigation of silicon nanoparticle composite anodes for Li-ion batteries, using a combination of two nm-scale atomic force microscopy-based techniques: scanning spreading resistance microscopy for electrical conduction mapping and contact resonance and force volume for elastic modulus mapping, along with scanning electron microscopy-based energy dispersion spectroscopy, nanoindentation, and electrochemical analysis. Thermally curing the composite anode—made of polyethylene oxide-treated Si nanoparticles, carbon black, and polyimide binder—reportedly improves the anode electrochemical performance significantly. This work demonstrates phase segregation resulting from thermal curing, where alternating bands of carbon and silicon active material are observed. This electrode morphology is retained after extensive cycling, where the electrical conduction of the carbon-rich bands remains relatively unchanged, but the mechanical modulus of the bands decreases distinctly. These electrical and mechanical factors may contribute to performance improvement, with carbon bands serving as a mechanical buffer for Si deformation and providing electrical conduction pathways. This work motivates future efforts to engineer similar morphologies for mitigating capacity loss in silicon electrodes.

25 ENERGY STORAGE↗

River Meander Studies

The feasibility of using satellite television photography of geomorphological indices to obtain a correlation between a stream meander power spectrum and stream discharge frequency distribution is considered. Water resources assessment includes information on the average rainfall over large drainage basins and calculations relating flow measurements to geographical areas. Photoelectric optical scanning techniques provide a digitized procedure for locating and following river meander curve points.

Schubert, G.↗

Detection of lack of fusion using opaque additives, phase 2

Plasma-sprayed copper coatings were developed to protect the aluminum surfaces of spacecraft structures from oxidation, as well as to provide a means of reliable nondestructive X-ray inspection of possible incomplete weldment penetration. Sixty day storage tests of coated aluminum samples indicated the promise of long-term oxidation protection, but revealed no advantage in detecting penetration defects. Delta-scan techniques were used, and peen plating as a means of applying copper to the aluminum surface was investigated.

Cook, J. L.↗

The neutral-atmosphere temperature instrument.

The determination of the temperature of the neutral gas at the location of the satellite is based on measurement of the velocity distribution of the molecular nitrogen. Measurement of the thermal-velocity component in the presence of the free-stream velocity will be obtained through application of the velocity-scan technique and, independently, through use of a baffle technique. A 3-cm diameter spherical sampling chamber with a 0.5-cm diameter precisely knife-edged orifice is located at the satellite equator to permit free diffusion of atmosphere gases between the chamber interior and the atmosphere. The spherical chamber is connected through a high-conductance tube to a quadrupole mass-spectrometer sensor to permit accurate quantitative evaluation of the density of the gas.

Spencer, N. W.↗

Application of a single laser Doppler system to the measurement of atmospheric winds

The feasibility of employing a single laser Doppler velocimeter (LDV) system to remotely measure one-, two-, and three-dimensional velocity components in atmospheric flow fields is presented. A focused continuous wave CO2 laser emitting at the 10.6 mu wavelength is used as the laser source. Scan configurations employed by the LDV system were single-point, two-point, conical, and spiral conical. Test results are presented, which include favorable comparisons of velocity components measured by conventional anemometry and the LDV system. The feasibility using a single-beam LDV employing a conical scan technique for measuring two- and three-dimensional mean winds. Measurements to 300 m in dense fogs showed the ability of the LDV system to operate in dense fogs.

Cliff, W. C.↗

Occultation of beta Scorpii by Jupiter. V - The emersion of beta Scorpii C

Use of multicolor photometry to remove planetary limb contamination from occultation light curves is demonstrated. This color restoration procedure is shown to be more advantageous than limb scanning techniques since it allows continuous observation of the occultation. Sharp spikes appearing in the light curve of beta Sco C are compared with those observed during the occultation of beta Sco AB, and a model is developed for estimating the effects of all factors affecting the observed shape of a spike. The widths of the narrowest spikes are shown to correspond closely to the angular diameters of the occulted stars, suggesting that occultation spikes can be used to determine stellar diameters.

Elliot, J. L.↗

Some physical and thermodynamic properties of rocket exhaust clouds measured with infrared scanners

Measurements using infrared scanners were made of the radiation from exhaust clouds from liquid- and solid-propellant rocket boosters. Field measurements from four launches were discussed. These measurements were intended to explore the physical and thermodynamic properties of these exhaust clouds during their formation and subsequent dispersion. Information was obtained concerning the initial cloud's buoyancy, the stabilized cloud's shape and trajectory, the cloud volume as a function of time, and it's initial and stabilized temperatures. Differences in radiation intensities at various wavelengths from ambient and stabilized exhaust clouds were investigated as a method of distinguishing between the two types of clouds. The infrared remote sensing method used can be used at night when visible range cameras are inadequate. Infrared scanning techniques developed in this project can be applied directly to natural clouds, clouds containing certain radionuclides, or clouds of industrial pollution.

Gomberg, R. I.↗

Airline pilot scanning behavior during approaches and landing in a Boeing 737 simulator

A series of approaches using airline-rated Boeing 737 pilots in an FAA qualified simulator was conducted. The test matrices include both manual and coupled approaches for VFR, Category 1 and Category 2 conditions. A nonintrusive oculometer system was used to track the pilot's eye-point-of-regard throughout the approach. The results indicate that, in general, the pilots use a different scan technique for the manual and coupled (auto-pilot with manual throttle) conditions. For the manual approach 73 percent of the time was spent on the Flight Director and 13 percent on airspeed as opposed to 50 percent on Flight Director and 23 percent on airspeed for the coupled approaches. For the visual portion of approach from less than 100m to touchdown or when the touchdown point came into view, the pilots tend to fixate on their aim or touchdown area until the flare initiation, at which time they let their eye-point-of-regard move up the runway to use the centerline lights for rollout guidance.

Spady, A. A., Jr.↗

Magnetometer with a miniature transducer and automatic scanning

The magnetometer is based on the time variation of the magnetic permeability in the magnetic material of its transducer; however, its operation is substantially different from the ordinary flux-gate magnetometer. The transducer uses 0.05 mm diameter plated magnetic wire and is made flat enabling it to make measurements of transverse magnetic fields as close as 0.08 mm from the surface, and it has very good spatial resolution because of its small active region of approximately 0.64 mm by 0.76 mm. The magnetometer uses an inexpensive clip-on millimeter for driving and processing the electrical signals and readout. It also utilizes an automatic scanning technique which is made possible by a specially designed transducer holding mechanism that replaces the ink pen on an X-Y recorder.

Debnam, W. J. J.↗

Fatigue damage in notched composite laminates

This communication describes the results of an experimental investigation of the fatigue characteristics of a boron-epoxy laminate containing an unloaded circular hole. The study focuses upon characterization of the fatigue damage incurred and its influence upon axial tensile residual strength. Two apparent anomalies in the fatigue behavior for this laminate were observed. First, the fatigue damage was observed to propagate tangentially to the edge of the notch (parallel to the direction of the load), in contrast to propagation in contemporary metallic materials which is perpendicular to the load direction. Second, the residual strength characteristics for the laminate have revealed a significant increase in residual strength subsequent to a fatigue loading of 500,000 cycles at R = 0.1 and S = 0.8 and 0.67 (S = maximum stress/static ultimate). Failure analyses of the fatigue damage are conducted utilizing ultrasonic 'C' scan techniques.

Pipes, R. B.↗

Airline pilot scanning behavior during approaches and landing in a Boeing 737 simulator

A series of approaches using airline-rated Boeing 737 pilots in an FAA qualified simulator has been conducted. The test matrices include both manual and coupled approaches for VFR, Category I and Category II conditions. A nonintrusive oculometer system was used to track the pilot's eye-point-of-regard throughout the approach. The results indicate that, in general, the pilots use a different scan technique for the manual and coupled (auto-pilot with manual throttle) conditions. For the manual approach 73 percent of the time was spent on the Flight Director and 13 percent on airspeed as opposed to 50 percent on Flight Director and 23 percent on airspeed for the coupled approaches. For the visual portion of approach from less than 100 m (300 ft) to touchdown or when the touchdown point came into view, the pilots tend to fixate on their aim or touchdown area until the flare initiation, at which time they let their eye-point-of-regard move up the runway to use the centerline lights for rollout guidance.

Spady, A. A., Jr.↗

Detection of internal defects in a liquid natural gas tank by use of infrared thermography

The use of an infrared scanning technique to detect defects in the secondary barrier of a liquid natural gas tank is described. The method works by detecting leak-caused temperature differences as low as 0.2 K, but can provide only an approximate idea of the extent of the defect. The nondestructive method was tested in a study of a LNG tank already at its location in a ship; the secondary barrier was located inside the tank wall. Defective areas indicated by the infrared radiometric measurements were confirmed by other probe techniques and by physical examination.

Kantsios, A. G.↗

Detection of tanker defects with infrared thermography

Infrared scanning technique for finding defects in secondary barrier of liquid natural gas (LNG) tank has been successfully tested on ship under construction at Newport News Shipbuilding and Dry Dock Company. Technique determines defects with minimal expenditure of time and manpower. Tests could be repeated during life of tanker and make more complicated testing unnecessary. Tests also confirmed that tank did not have any major defects, and tank was certified.

Kantsios, A. G.↗

Analysis and acoustooptical measurements of bulk and surface acoustic wave fields

The development of multielement ultrasonic transducers having full field amplitude and phase control is discussed. In addition, the measurement of the surface particle displacement caused by an idealized impulse load on the surface, the three dimensional mapping of acoustic fields using optical scanning techniques, and the measurement of two dimensional stress distributions using embedded optical fiber sensors are addressed.

Claus, R. O.↗