Search NASA⌕ Search

SEARCH · Search NASA

Results for “Segmented telescopes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

OCCAMS: Optically Controlled and Corrected Active Meta-Material Space Structures

Telescopes require sub-wavelength figure (shape) error in order to achieve acceptable Strehl ratios. Traditional methods of achieving this require rigid and therefore heavy mirrors and reaction structures as well as proportionally heavy and expensive spacecraft busses and launch vehicles. This effectively limits the diameter and therefore resolution and collecting area of space optics. Large diameter telescopes must either be heavy or actively controlled. Space telescopes of the size proposed for missions such as TPF (Terrestrial Planet Finder), TPI (Terrestrial Planet Imager), etc. will likely require large active primaries and structures and corrective optics to implement downstream wavefront control. We propose a novel viable enabling technology. High resolution space imaging requires the production of lightweight large aperture optics subject to design tradespace constraints based on nanometer physical tolerances, low system aerial density, high control authority, suitable thermal and mechanical properties, deployment capability, launch vehicle volume constraints, as well as production cost and schedule risk mitigation. Segmented systems impose additional requirements on segment alignment, wavefront phasing, and telescope mass with increased edge diffraction. Photons weigh nothing. Why must even small space telescopes "weigh" tons? Our team is working to demonstrate that they do not, by leveraging 15 years of effort and a novel advanced concept.The ultimate research goal is to refine technology to produce a mission capable ultra-lightweight membrane optic whose shape can be remotely controlled using a laser beam. Using our novel optically-controlled molecular actuators allows substitution of optically-induced control for rigidity and mirror mass. In analogy with noise-canceling headphones, this technique also potentially provides a way to excite vibratory modes to couple with and damp out normal modes of oscillation induced by slewing, other motion and thermal changes, thus allowing a robust response to repointing of a large aperture.

Astronomy↗

Precision segmented reflectors for space applications

A project to develop precision segmented reflectors (PSRs) which operate at submillimeter wavelengths is described. The development of a light efficient means for the construction of large-aperture segmented reflecting space-based telescopes is the primary aim of the project. The 20-m Large Deployable Reflector (LDR) telescope is being developed for a survey mission, and it will make use of the reflector panels and materials, structures, and figure control being elaborated for the PSR. The surface accuracy of a 0.9-m PSR panel is shown to be 1.74-micron RMS, the goal of 100-micron RMS positioning accuracy has been achieved for a 4-m erectable structure. A voice-coil actuator for the figure control system architecture demonstrated 1-micron panel control accuracy in a 3-axis evaluation. The PSR technology is demonstrated to be of value for several NASA projects involving optical communications and interferometers as well as missions which make use of large-diameter segmented reflectors.

Lehman, David H.↗

Performance of Dispersed Fringe Sensor in the Presence of Segmented Mirror Aberrations: Modeling and Simulation

Dispersed Fringe Sensing (DFS) is an efficient and robust method for coarse phasing of a segmented primary mirror such as the James Webb Space Telescope (JWST). In this paper, modeling and simulations are used to study the effect of segmented mirror aberrations on the fringe image, DFS signals and DFS detection accuracy. The study has shown due to the pixilation spatial filter effect from DFS signal extraction the effect of wavefront error is reduced and DFS algorithm will be more robust against wavefront aberration by using multi-trace DFS approach. We also studied the JWST Dispersed Hartmann Sensor (DHS) performance in presence of wavefront aberrations caused by the gravity sag and we use the scaled gravity sag to explore the JWST DHS performance relationship with the level of the wavefront aberration. This also includes the effect from line-of-sight jitter.

segmented mirrors↗

A Scanning Hartmann Focus Test for the EUVI Telescopes aboard STEREO

The Solar TErrestrial RElations Observatory (STEREO), the third mission in NASA s Solar Terrestrial Probes program, was launched in 2006 on a two year mission to study solar phenomena like coronal mass ejections. STEREO consists of two nearly identical satellites, each carrying a suite of instruments that provide, among other data, simultaneous images of the Sun. One of these telescopes is the Extreme Ultraviolet Instrument (EUVI). There are two EUVI telescopes, one on each STEREO satellite (EUVI-A and EUVI-B). EUVI is a normal incidence, 98mm diameter, Ritchey-Chretien telescope designed to obtain wide field of view (approx.1deg) images of the Sun at short wavelengths (approx.20nm) using a CCD detector. The telescope entrance aperture is divided into four quadrants by a mask near the secondary mirror spider veins. A mechanism that rotates another mask allows only one of these sub-apertures to accept light from the Sun during an observation. The EUVI is thus four co-aligned, off-axis telescopes. Each off-axis segment on the primary and secondary mirrors has a different extreme ultraviolet coating stack. Furthermore, the aperture select mechanism is synchronized with a filter wheel mechanism near the CCD detector. The EUVI contains no focus mechanism. Models predict that the difference in on-orbit operating temperature and ambient clean room conditions yield a "best focus" difference between integration and operation of approx. 0.2mm.

Ohl, R.↗

An Automated SVD for Alignment and Control of James Webb Space Telescope Mirrors

The James Webb Space Telescope (JWST) is a three-mirror anastigmatic telescope. The alignment of the segmented primary and secondary mirrors in the wavefront sensing and control process involves a series of actuators to control the six degrees-of-freedom motion on each surface in addition to the radius of curvature. The control matrix developed from the alignment parameters is over-determined and singular value decomposition (SVD) method is used to solve it in the least square sense. An automated SVD scheme has been developed to identify the most contributing modes in a typical alignment process and reduce the impact of error-prone modes from the control process.

Shiri, Sharam↗

The Advanced Topographic Laser Altimeter System (ATLAS) for NASA's Ice Cloud and Land Elevation Satellite-2 (ICESat-2): Design, Development, and On-Orbit Performance

Conceived in response to the 2007 Earth Science Decadal Survey, ATLAS/ICESat-2 was launched on September 15, 2018 to a polar orbit and has been operating continuously since. The ATLAS instrument is a continuously-operating direct-detection pulsed laser altimeter utilizing a solid-state 532-nm laser source operating at a 10-kHz pulse repetition rate along with a diffractive optic to illuminate six 15-meter spots on the Earth's surface with each laser pulse. An 80-cm receiver telescope fiber-coupled to segmented photomultipliers provides single-photon detection capability. This presentationr will present an overview of the ATLAS instrument design, some challenges encountered during development, and initial results from orbit.

Lidar↗

A Parametric Finite-Element Model for Evaluating Segmented Mirrors with Discrete, Edgewise Connectivity

Since future astrophysics missions require space telescopes with apertures of at least 10 meters, there is a need for on-orbit assembly methods that decouple the size of the primary mirror from the choice of launch vehicle. One option is to connect the segments edgewise using mechanisms analogous to damped springs. To evaluate the feasibility of this approach, a parametric ANSYS model that calculates the mode shapes, natural frequencies, and disturbance response of such a mirror, as well as of the equivalent monolithic mirror, has been developed. This model constructs a mirror using rings of hexagonal segments that are either connected continuously along the edges (to form a monolith) or at discrete locations corresponding to the mechanism locations (to form a segmented mirror). As an example, this paper presents the case of a mirror whose segments are connected edgewise by mechanisms analogous to a set of four collocated single-degree-of-freedom damped springs. The results of a set of parameter studies suggest that such mechanisms can be used to create a 15-m segmented mirror that behaves similarly to a monolith, although fully predicting the segmented mirror performance would require incorporating measured mechanism properties into the model. Keywords: segmented mirror, edgewise connectivity, space telescope

Gersh-Range, Jessica A.↗

Experimental Validation of a Neuro-Fuzzy Approach to Phasing the SIBOA Segmented Mirror Testbed

NASA is preparing to launch the Next Generation Space Telescope (NGST). This telescope will be larger than the Hubble Space Telescope, be launched on an Atlas missile rather than the Space Shuttle, have a segmented primary mirror, and be placed in a higher orbit. All these differences pose significant challenges. This effort addresses the challenge of aligning the segments of the primary mirror during the initial deployment. The segments need to piston values aligned to within one tenth of a wavelength. The present study considers using a neuro-fuzzy model of the Fraunhofer diffraction theory. The intention of the current study was to experimentally verify the algorithm derived earlier. The experimental study was to be performed on the SIBOA (Systematic Image Based Optical Alignment) test bed. Unfortunately the hardware/software for SIBOA was not ready by the end of the study period. We did succeed in capturing several images of two stacked segments with various relative phases. These images can be used to calibrate the algorithm for future implementation. This effort is a continuation of prior work. The basic effort involves developing a closed loop control algorithm to phase a segmented mirror test bed (SIBOA). The control algorithm is based on a neuro-fuzzy model of SIBOA and incorporates nonlinear observers built from observer banks. This effort involves implementing the algorithm on the SIBOA test bed.

Philip D. Olivier↗

Labview Implementation of Image Processing and Phasing Control for the SIBOA Segmented Mirror Testbed

NASA is preparing to launch the Next Generation Space Telescope (NGST). This telescope will be larger than the Hubble Space Telescope, be launched on an Atlas missile rather than the Space Shuttle, have a segmented primary mirror, and be placed in a higher orbit. All these differences pose significant challenges.' This effort addresses the challenge of implementing an algorithm for aligning the segments of the primary mirror during the initial deployment that was designed by Philip Olivier and members of SOMTC (Space Optics Manufacturing Technology Center). The implementation was to be performed on the SIBOA (Systematic Image Based Optical Alignment) test bed. Unfortunately, hardware/software aspect concerning SIBOA and an extended time period for algorithm development prevented testing before the end of the study period. Properties of the digital camera were studied and understood, resulting in the current ability of selecting optimal settings regarding saturation. The study was successful in manually capturing several images of two stacked segments with various relative phases. These images can be used to calibrate the algorithm for future implementation. Currently the system is ready for testing.

James D. Partridge↗

Picometer Level Spatial Metrology for Next Generation Telescopes

During the testing of the primary mirror segments for JWST, our team realized that some of the tools and techniques we had developed could be pushed further to achieve picometer resolution.We began developing incremental techniques for measuring, controlling, sensing to picometer levelsSeveral recent peer reviewed papers have shown that we can measure this level of change, control it with actuators, and potentially even develop active architectures using these ideasWe will show how the work on JWST evolved to systems applicable to measure picometer and even sub-picometer levels, show the results, and discuss implications for future telescope like LUVOIR and Habex

Keski-Kuha, R.↗

Multivariable Parametric Cost Model for Ground Optical Telescope Assembly

A parametric cost model for ground-based telescopes is developed using multivariable statistical analysis of both engineering and performance parameters. While diameter continues to be the dominant cost driver, diffraction-limited wavelength is found to be a secondary driver. Other parameters such as radius of curvature are examined. The model includes an explicit factor for primary mirror segmentation and/or duplication (i.e., multi-telescope phased-array systems). Additionally, single variable models Based on aperture diameter are derived.

Stahl, H. Philip↗

Multivariable Parametric Cost Model for Ground Optical: Telescope Assembly

A parametric cost model for ground-based telescopes is developed using multi-variable statistical analysis of both engineering and performance parameters. While diameter continues to be the dominant cost driver, diffraction limited wavelength is found to be a secondary driver. Other parameters such as radius of curvature were examined. The model includes an explicit factor for primary mirror segmentation and/or duplication (i.e. multi-telescope phased-array systems). Additionally, single variable models based on aperture diameter were derived.

Stahl, H. Philip↗

Size Optimization for Mirror Segments for X-Ray Optics

The flight mirror assemblies (FMA) for X-ray telescopes similar to that of the International X-ray Observatory (IXO) concept consist of several thousands of individual mirror segments. The size, shape, and location of these mirrors affect many characteristics of the telescope design. Mission requirements among other factors in turn restrict mirror segment parameters such as thickness, axial- length, azimuthal span, and mass density. This paper provides an overview of the critical relationships relating to mirror segment size and configuration throughout the design and analysis of an X-ray mirror assembly. A computational analysis is presented in the form of ray tracing pairs of thin X-ray mirror segments of varying sizes aligned in gravity and supported using kinematic constraints with corresponding self weight distortions calculated using finite element analysis (FEA). The work in this paper may be used as a starting point for determining mirror segment sizes for X-ray missions like that of IXO and beyond.

Biskach, Michael P.↗

The James Webb Space Telescope Mission: Optical Telescope Element Design, Development, and Performance

The James Webb Space Telescope (JWST) is a large, infrared space telescope that has recently started its science program which will enable breakthroughs in astrophysics and planetary science. Notably, JWST will provide the very first observations of the earliest luminous objects in the universe and start a new era of exoplanet atmospheric characterization. This transformative science is enabled by a 6.6 m telescope that is passively cooled with a 5 layer sunshield. The primary mirror is comprised of 18 controllable, low areal density hexagonal segments, that were aligned and phased relative to each other in orbit using innovative image-based wave front sensing and control algorithms. This revolutionary telescope took more than two decades to develop with a widely distributed team across engineering disciplines. We present an overview of the telescope requirements, architecture, development, superb on-orbit performance, and lessons learned. JWST successfully demonstrates a segmented aperture space telescope and establishes a path to building even larger space telescopes.

Infrared observatories↗

Wavefront Control and Image Restoration with Less Computing

PseudoDiversity is a method of recovering the wavefront in a sparse- or segmented- aperture optical system typified by an interferometer or a telescope equipped with an adaptive primary mirror consisting of controllably slightly moveable segments. (PseudoDiversity should not be confused with a radio-antenna-arraying method called pseudodiversity.) As in the cases of other wavefront- recovery methods, the streams of wavefront data generated by means of PseudoDiversity are used as feedback signals for controlling electromechanical actuators of the various segments so as to correct wavefront errors and thereby, for example, obtain a clearer, steadier image of a distant object in the presence of atmospheric turbulence. There are numerous potential applications in astronomy, remote sensing from aircraft and spacecraft, targeting missiles, sighting military targets, and medical imaging (including microscopy) through such intervening media as cells or water. In comparison with prior wavefront-recovery methods used in adaptive optics, PseudoDiversity involves considerably simpler equipment and procedures and less computation. For PseudoDiversity, there is no need to install separate metrological equipment or to use any optomechanical components beyond those that are already parts of the optical system to which the method is applied. In Pseudo- Diversity, the actuators of a subset of the segments or subapertures are driven to make the segments dither in the piston, tilt, and tip degrees of freedom. Each aperture is dithered at a unique frequency at an amplitude of a half wavelength of light. During the dithering, images on the focal plane are detected and digitized at a rate of at least four samples per dither period. In the processing of the image samples, the use of different dither frequencies makes it possible to determine the separate effects of the various dithered segments or apertures. The digitized image-detector outputs are processed in the spatial-frequency (Fourier-transform) domain to obtain measures of the piston, tip, and tilt errors over each segment or subaperture. Once these measures are known, they are fed back to the actuators to correct the errors. In addition, measures of errors that remain after correction by use of the actuators are further utilized in an algorithm in which the image is phase-corrected in the spatial-frequency domain and then transformed back to the spatial domain at each time step and summed with the images from all previous time steps to obtain a final image having a greater signal-to-noise ratio (and, hence, a visual quality) higher than would otherwise be attainable.

Lyon, Richard G.↗

The James Webb Space Telescope

The James Webb Space Telescope (JWST) is a large, infrared-optimized space telescope. JWST's primary science goal is to detect and characterize the first galaxies. It will also study the assembly of galaxies, star formation, and the formation of evolution of planetary systems. The observatory has a large primary mirror 6.5 meter in diameter, designed to deliver high angular resolution in the infrared, combined with a large collecting area. The telescope optics are designed and fabricated to operate at the cryogenic temperatures (,...,40 k) required for an IR optimized telescope. The primary mirror is also a segmented mirror architecture. The observatory is designed to achieve cryogenic operating temperature via passive cooling, facilitated by a five-layer sunshield which keeps the telescope in the sun's shadow. Since the observatory dimensions exceed the Ariane 5 fairing size, the observatory has to be stowed for launch and deployed following launch. The observatory will be launched into an L2 orbit that provides continuous science operations and a benign thermal environment for optical stability.

Clampin, Mark↗

Incoming Metrology of Segmented X-Ray Mandrels at MSFC

The Constellation-X Spectroscopy X-ray telescope (SXT) is designed to be built from X-ray optic segments. The X-ray segments will be fabricated from the segmented mandrels using a replication process. The purpose of the incoming metrology is to map the surface of the mandrels, so the performance of the X-ray optics produced can be predicted. Three Constellation-X segmented mandrels have been delivered to MSFC for incoming metrology. The segmented mandrels are 30-degree sections of a cylindrical surface and have diameters of 1.0 m, 1.2 m and 1.6 m. The maximum dimensions of the optical surface are 1.0 m axial length and 0.5 m azimuthal segment length. The metrology of the mandrels consists of the measurement of their slope differences, roundness, absolute radius, axial profile and microroughness. Accuracy goals for each type of measurement and the accuracy of the instruments used for the measurements will be discussed. The results of the mandrel metrology together with the performance predictions will be presented.

Gubarev, Mikhail↗