Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sensitivity Matrix”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Identification of Distribution of Elastic Constants of SiC/SiC Braided Tubes

There has been considerable interest in chemical vapor infiltration (CVI) manufactured silicon carbide fiber and silicon carbide matrix (SiCf/SiCm) composite tubes due to their superior mechanical properties. There are many parameters in the manufacturing of SiCf/SiCm composite tubes such as elastic constants of constituent SiC fiber and SiC matrix, braiding angle, porosity, and others whose values vary over a range. A sensitivity analysis will be carried out to determine the dominant parameters among the abovementioned ones. We intend to determine the variability in elastic constants of SiCf/SiCm composite tubes considering the variability in dominant parameters. A chosen number of combinations of dominant variables will be sampled through Latin hypercube sampling (LHS) method. The elastic constants of composite tube namely Young's moduli in circumferential and longitudinal direction, Poisson's ratio and shear modulus will be calculated at sampled points through finite element (FE) analysis. A polynomial response surface (PRS) will be built for each of the elastic constants to be used a surrogate to FE analysis. once the predictive accuracy of PRS is verified at the validation set of data points, the PRS will be invoked 105 times in Monte Carlo simulations (MCS). The variability can be calculated based on MCS-generated data which will be presented at the conference.

42 ENGINEERING↗

Measurement of the WW+WZ Production Cross Section Using the Lepton+Jets Final State at CDF II

We report two complementary measurements of the diboson (WW + WZ) cross section in the final state consisting of an electron or muon, missing transverse energy, and jets, performed using p{bar p} collision data at {radical}s = 1.96 TeV collected by the Collider Detector at Fermilab. The first method uses the dijet invariant mass distribution while the second method uses more of the kinematic information in the event through matrix-element calculations of the signal and background processes and has a higher sensitivity. The result from the second method has a signal significance of 5.4{sigma} and is the first observation of WW + WZ production using this signature. Combining the results from both methods gives {sigma}{sub WW+WZ} = 16.0 {+-} 3.3 pb, in agreement with the standard model prediction.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Ultra Sensitive Neutron Activation Measurements of {sup 232}Th in Copper

Copper, thanks to its low content in radioactive contaminations, is a material widely used for shielding, holders and other objects close to the sensitive parts of the detectors in many experiments in rare event physics. This implies that tools able to reach sensitivity of the order of <10{sup -12} gram of contaminants per gram of copper are of crucial importance. A methodology based in Neutron Activation Analysis (NAA) has been developed to obtain an extremely high sensitivity in the analysis of {sup 232}Th in copper samples. A detection limit of 5x10{sup -13} g {sup 232}Th/g Cu has been achieved through the irradiation of 200 g of copper sample which subsequently was radio-chemically concentrated using nitric acid and then actinide resin from Eichrom Inc. Several elutions were performed with various inorganic acids to concentrate the {sup 232}Th activation product ({sup 233}Pa) from the copper matrix and to also eliminate the radioactive background induced by the neutron bombardment to reach higher sensitivity.

36 MATERIALS SCIENCE↗

Analysis of semivolatile organics in liquid radioactive residue using sorptive stir bar and solvent back-extraction

Current methods for semivolatiles analysis in radioactive samples can produce large volumes of radioactive solvent residue. A method utilizing stir-bar sorptive extraction has been explored in this work for its applicability to radioactive waste samples. This low solvent analytical method may accelerate remediation, minimize hazardous solvent waste, and reduce exposure risk to workers. Organic compounds (polyaromatic hydrocarbons, chlorinated aromatics, and phenolic compounds) were chosen as surrogates for common Liquid Waste System (LWS) contaminants at Savannah River Site (Aiken, SC). Stir-bar extraction parameters (extraction time, matrix modification, and effective pH range) and solvent back extraction parameters (solvent type, volume, and extraction time) were optimized experimentally for the chosen compounds. Affinity of the stir-bar extraction polymer to radionuclides Cs-137 and Am-241 was observed to determine radionuclide concentration effects. The stir-bar method achieved mean recovery of 100 ± 0.7% (1σ), relative to 114 ± 7% using solvent extraction, while reducing weekly method hands-on time by 93.4% and solvent volume consumption by 99.3%. Sensitivity was improved by 378% in simulated tank waste and 278% in real-world LWS matrix, relative to solvent extraction. This work has produced a safe and optimized method for the low solvent analysis of organics in legacy radioactive tank waste by stir-bar sorptive extraction.

GC-MS↗

Luminescence switching in Ce{sup 3+} ion sensitized YPO{sub 4}:Tb{sup 3+} through Redox reaction

Highlights: • Simple polyol method for preparation of Ce{sup 3+} sensitized Tb{sup 3+} ion doped YPO{sub 4} nanophosphor. • Enhanced green color emission with incorporation of Ce{sup 3+} ion into the matrix of YPO{sub 4}:Tb{sup 3+} nanophosphor. • Highly crystalline tetragonal YPO{sub 4}:Tb{sup 3+} without any impurity phase. • Use of alternate oxidising and reducing agent for luminescence switching (ON and OFF). - Abstract: Ce{sup 3+} sensitized Tb{sup 3+} ion doped YPO{sub 4} nanophosphor is synthesized by simple polyol method using ethylene glycol as capping agent as well as reaction medium. Green emission from Tb{sup 3+} ion doped YPO{sub 4} nanophosphor has been enhanced with incorporation of Ce{sup 3+} ion into the matrix of YPO{sub 4}:Tb{sup 3+}. XRD of YPO{sub 4}:Tb{sup 3+} annealed at 900 °C reveals crystalline tetragonal structure without any impurity phase. Morphology of YPO{sub 4}:Tb{sup 3+} nanophosphor was also studied. Homogenous incorporation of rare earth, RE (RE = Tb{sup 3+}, Ce{sup 3+}) ion into the host matrix were given in EDAX spectra. TGA/DTA analysis shows phase transformation of the as-prepared sample. Also, it is found that the as-prepared sample were readily re-dispersible in water due to presence of −OH group. By using an alternate oxidising and reducing agent, behaviour of luminescence switching (ON and OFF) can be examined. Lifetime decay of Tb{sup 3+} ion doped YPO{sub 4} nanophosphor was also studied.

36 MATERIALS SCIENCE↗

Identification of interstratified mica and pyrophyllite monolayers within chlorite using advanced scanning/transmission electron microscopy

Interstratified clay minerals reflect the weathering degree and record climatic conditions and the pedogenic processes in the soil. It is hard to distinguish a few layers of interstratified clay minerals from the chlorite matrix, due to their similar two-dimensional tetrahedral-octahedral-tetrahedral (TOT) structure and electron-beam sensitive nature during transmission electron microscopy (TEM) imaging. In this study, we used multiple advanced TEM techniques including low-dose high-resolution TEM (HRTEM), high-angle annular dark-field scanning transmission electron microscopy (HAADF-STEM) imaging combined with energy-dispersive spectroscopic (EDS) mapping to study interstratified layers in a chlorite sample from Changping, Beijing, China. We demonstrated an interstratified mica or pyrophyllite monolayer could be well distinguished from the chlorite matrix by projected atomic structures, lattice spacings, and chemical compositions with advanced TEM techniques. Further investigation showed two different transformation mechanisms from mica or pyrophyllite to chlorite: either a 4 A increase or decrease in the lattice spacing. Lastly, this characterization approach can be extended to the studies of other electron-beam sensitive minerals.

36 MATERIALS SCIENCE↗

Response Surface Methodology As a New Approach for Finding Optimal MALDI Matrix Spraying Parameters for Mass Spectrometry Imaging

Automated spraying devices have become ubiquitous in laboratories employing matrixassisted laser desorption/ionization mass spectrometry imaging (MALDI-MSI), in part because they permit control of a number of matrix application parameters that can easily be reproduced for intra- and interlaboratory studies. Determining the optimal parameters for MALDI matrix application, such as temperature, flow rate, spraying velocity, number of spraying cycles, and solvent composition for matrix application, is critical for obtaining high-quality MALDI-MSI data. However, there are no established approaches for optimizing these multiple parameters simultaneously. Instead optimization is performed iteratively (i.e., one parameter at a time), which is time consuming and can lead to overall non-optimal settings. In this report, we demonstrate the use a novel experimental design and the response surface methodology to optimize five parameters of MALDI matrix application using a robotic sprayer. Thirtytwo combinations of MALDI matrix spraying conditions were tested, which allowed us to elucidate relationships between each of the application parameters as determined by MALDI-MS (specifically, using a 15 Tesla Fourier transform ion cyclotron resonance mass spectrometer). As such, we were able to determine the optimal automated spraying parameters that minimized signal de-localization and enabled high MALDI sensitivity. We envision this optimization strategy can be utilized for other MALDI-MSI applications, tissue types, and matrix application approaches.

60 APPLIED LIFE SCIENCES↗

HPW-RX40 restores anoikis sensitivity of human breast cancer cells by inhibiting integrin/FAK signaling

Anoikis is defined as apoptosis, which is induced by inappropriate cell–matrix interactions. Cancer cells with anoikis resistance tend to undergo metastasis, and this phenomenon has been reported to be associated with integrin and FAK activity. HPW-RX40 is a derivative of 3,4-methylenedioxy-β-nitrostyrene, which is known to prevent platelet aggregation by inhibition of integrin. In the present study, we investigated the effect of HPW-RX40 on an anoikis-resistant human breast cancer cell line MDA-MB-231. HPW-RX40 inhibited cell aggregation and induced cell death in suspending MDA-MB-231 cells, but had only little effect on the monolayer growth of adherent cells. Analysis of caspase activation and poly (ADP-ribose) polymerase (PARP) cleavage confirmed anoikis in HPW-RX40-treated suspending cancer cells. HPW-RX40 also affected the Bcl-2 family proteins in detached cancer cells. Furthermore, HPW-RX40 inhibited detachment-induced activation of FAK and the downstream phosphorylation of Src and paxillin, but did not affect this pathway in adherent cancer cells. We also found that the expression and activation of β1 integrin in MDA-MB-231 cells were reduced by HPW-RX40. The combination of HPW-RX40 with an EGFR inhibitor led to enhanced anoikis and inhibition of the FAK pathway in breast cancer cells. Taken together, our results suggest that HPW-RX40 restores the anoikis sensitivity in the metastatic breast cancer cells by inhibiting integrin and subsequent FAK activation, and reveal a potential strategy for prevention of tumor metastasis. - Highlights: • The β-nitrostyrene derivative, HPW-RX40, induces anoikis in human breast cancer cells. • HPW-RX40 inhibits the integrin/FAK signaling pathway. • The combination of HPW-RX40 with an EGFR inhibitor leads to enhanced anoikis. • HPW-RX40 may have a potential to prevent the spread of metastatic breast cancer.

60 APPLIED LIFE SCIENCES↗

Sorption‐Induced Fiber Optic Plasmonic Gas Sensing via Small Grazing Angle of Incidence

Abstract Sensing technologies based on plasmonic nanomaterials are of interest for various chemical, biological, environmental, and medical applications. In this work, an incorporation strategy of colloidal plasmonic nanoparticles (pNPs) in microporous polymer for realizing distinct sorption‐induced plasmonic sensing is reported. This approach is demonstrated by introducing tin‐doped indium oxide pNPs into a polymer of intrinsic microporosity (PIM‐1). The composite film (pNPs‐polymer) provides distinct and tunable optical features on the fiber optic (FO) platform that can be used as a signal transducer for gas sensing (e.g., CO 2 ) under atmospheric conditions. The resulting pNPs‐polymer composite demonstrates high sensitivity response on FO in the evanescent field configuration, provided by the dramatic response of modes above the total‐internal‐reflection angle. Furthermore, by varying the pNPs content in the polymer matrix, the optical behavior of the pNPs‐polymer composite film can be tuned to affect the operational wavelength by over several hundred nanometers and the sensitivity of the sensor in the near‐infrared range. It is also shown that the pNPs‐polymer composite film exhibits remarkable stability over a period of more than 10 months by mitigating the physical aging issue of the polymer.

Kim, Ki‐Joong↗

Conversion of experimental half-life to effective electron neutrino mass in 0nubetabeta decay

The Germanium Detector Array (GERDA) collaboration will be searching for neutrinoless double beta decay of {sup 76}Ge. As a result it will measure the half-life T{sub 1/2} of this rare process; or at least a new value for the lower limit for T{sub 1/2} will be derived. The sensitivity of the GERDA experiment on the effective electron neutrino mass <m{sub b}eta{sub b}eta> depends on the theoretical value for the nuclear matrix element M and the kinematical phase space factor G.In this Brief Report we focus on existing difficulties in applying the dimensionless values of M calculated by various theoretical groups, which use different methods and parametrizations. The implicit radius dependencies in M and G are discussed. Resulting values of the neutrino mass are tabulated for various representative half-lives T{sub 1/2} representing the sensitivity of the various phases of the GERDA experiment.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Transfer of Preformed Three-Dimensional Photonic Crystals onto Dye-Sensitized Solar Cells

Film star: Preformed self-assembled 3D photonic crystals (see picture) can be infilled with a polycarbonate matrix for mechanical stability and transferred onto rough and porous optoelectronic and photovoltaic devices. Here, this technique allows the incorporation of photonic crystals onto independently processed devices, in which the transferred films have high optical quality.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Carbon contamination, its consequences and its mitigation in ion-simulation of neutron-induced swelling of structural metals

Neutron-induced swelling in austenitic and ferritic steels is sensitive to the carbon level in the steel, as well as its distribution in matrix or precipitates. It has recently become known that ion-irradiation to high dpa levels leads to a progressive ion-beam-induced increase in carbon concentration and precipitation within the ion range, with concurrent reductions in void swelling. This neutron-atypical phenomenon imperils the credibility of ion simulation for light water reactor applications. A series of experiments involving pure iron and a structural alloy HT9, was conducted to identify the source and distribution of injected carbon. It was found that negatively-charged carbon atoms are entrained in the self-ion beam by a Coulomb drag effect, and thereby delivered at low drift energy to the irradiated surface, followed by ion-beam-mixing and diffusion. A technique for filtering out contaminants, especially carbon, oxygen and nitrogen, was developed and resulted in higher, more neutron-relevant swelling levels than achieved without filtering.

Shao, Lin↗

A proposed method for addressing large unphysical uncertainties in mubar

Mubar uncertainties in Section MF 34 MT 2 of ENDF/B-VIII.0 data are sometimes too large. Physical limitations of the bounds of mubar limit the maximum uncertainty to be < 1.0 and usually $\ll$ 1.0. Two ad hoc methods are proposed to artificially constrain the randomly sampled values of mubar to allowable values. The application of NJOY’s mubar covariance matrix to the “sandwich rule” is also discussed and a consistent way to apply sensitivity coefficients is described. Mubar uncertainties for the Jezebel k eff were found to be 156 pcm – a value comparable to other evaluated cross section uncertainties.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Extracting CP violation and strong phase in D decays by using quantum correlations in {psi}(3770){yields}D{sup 0}D{sup 0{yields}}(V{sub 1}V{sub 2})(V{sub 3}V{sub 4}) and {psi}(3770){yields}D{sup 0}D{sup 0{yields}}(V{sub 1}V{sub 2})(K{pi})

The charm quark offers interesting opportunities to cross check the mechanism of CP violation precisely tested in the strange and beauty sectors. In this paper, we exploit the angular and quantum correlations in the DD pairs produced through the decay of the {psi}(3770) resonance in a charm factory to investigate CP-violation in two different ways. We build CP-violating observables in {psi}(3770){yields}DD{yields}(V{sub 1}V{sub 2})(V{sub 3}V{sub 4}) to isolate specific new physics effects in the charm sector. We also consider the case of {psi}(3770){yields}DD{yields}(V{sub 1}V{sub 2})(K{pi}) decays, which provide a new way to measure the strong phase difference {delta} between Cabibbo- favored and doubly-Cabibbo suppressed D decays required in the determination of the Cabibbo-Kobayashi-Maskawa quark-mixing matrix angle {gamma}. Neglecting the systematics, we give a first rough estimate of the sensitivities of these measurements at BES-III with an integrated luminosity of 20 fb{sup -1} at {psi}(3770) peak and at a future Super {tau}-charm factory with a luminosity of 10{sup 35} cm{sup -2} s{sup -1}.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development of NDE/NDT Tools for High-Volume & High-Speed Inspection of CFRP Structures in Automotive Manufacturing

Main advantages of the air-coupled ultrasound testing (ACUT) and electromagnetic testing (EMT) techniques for NDE of CFRP composites were non-contact sensing, scalability for high-speed inspection, cost-effectiveness, and non-hazardous operation. Despite these advantages, no systems that would satisfy the project requirements were commercially available. Hence, one of the major efforts of the Michigan State University (MSU) team at the initial stage of the project was to close this technological gap by developing, optimizing, and validating array sensors that would provide sufficient sensitivity, spatial coverage, and resolution for robust defect detection. Optimization of the ACUT and EMT sensor designs was performed using experimentally validated finite element models. Initial experiments using array probes were conducted on relatively flat CFRP samples. In parallel, the MSU team designed and assembled a portable platform with two robotic arms. The robots were equipped with newly designed sensors that enabled high-speed NDE of curved CFRP parts. Presently, the developed robotic platform can be used as a demo/template NDE system, which is easily adaptable to manufacturing environments and in-line NDE. The ACUT NDE system developed by the MSU team used a high-power 4-channel pulser receiver for parallel data acquisition. The array probes were designed by stacking commercially available ACUT transducers, which operated in the frequency range between 100 kHz and 500 kHz. MSU optimized the excitation procedure and developed wave focusing cones so as to reduce the crosstalk between the transducers and to provide higher pulse repletion frequency (PRF). The through-transmission (TT) and single-side access (SSA) inspection modes were successfully implemented. In the TT-ACUT, structural defects in CFRP were detected by passing ultrasonic waves through the test part. Hence, the ACUT transmitters and receivers needed to be placed on the opposite sides of the test part. In the SSA-ACUT, guided waves (GW) were excited in the test part using the transmitters and were sensed by the receivers from the same side. Multi-channel TT-ACUT and SSA-ACUT provided high-speed NDE, and were successfully validated on CFRP test samples with interlaminar delaminations and other embedded defects The EM techniques developed by the MSU team included: 1) eddy current testing (ECT), 2) capacitive imaging (CI) and hybrid dual-mode imaging. In ECT, structural damage was detected in CFRP using coils sensor arrays. In ECT, the excitation magnetic field is generated by passing an alternating current through a coil, which is placed above the test sample. The excitation field penetrates the conductive sample and induces the eddy currents in its transect. In turn, the eddy currents generate the reaction field, which affects the total field sensed by a coil. Hence, the presence of structural flaws will alter the eddy current flow and the picked-up signal. ECT is mostly sensitive to local changes of the electric conductivity of the test sample, and CFRPs are mostly conductive in the direction of carbon fibers. Hence, ECT was well suited for the detection of fiber damage/fiber irregularities. The MSU team developed printed circuit boards (PCB) with coil sensor arrays optimized for NDE of CFRP. Unlike most commercial probes designed for ECT of metallic structures, the MSU array probes were designed for operation in [1-10] MHz frequency range, which was optimal for low-conductive CFRP. Multiple sensing topologies (coil groups excitation/sensing arrangements) were implemented and successfully validated. Capacitive Imaging (CI) technique developed by MSU was complementary to ECT. In contrast to ECT, which was sensitive to local changes of the electrical conductivity, the CI was sensitive to local changes of the dielectric constant. Therefore, CI could provide information about matrix damage/matrix irregularities in CFRP. The MSU CI sensor arrays were made of multiple circular or rectangular open-plate capacitors printed on PCB. Sensors of this type are not commercially available. In addition to ECT and CI, the MSU team developed a hybrid (dual-mode) inductive/capacitive measurement technique that synergistically combined the benefits of inductive and capacitive sensing for rapid NDE of fiber reinforced polymer (FRP) composite structures. Fiber damage and fiber irregularities in FRPs were detected by configuring hybrid sensors as coil sensors. Similarly, matrix damage, matrix irregularities and interlaminar delaminations were detected by configuring hybrid sensors as capacitive sensors. ECT and CI were performed sequentially by means of electronic switching. Hence, eliminating the need for mounting two separate sensor arrays on the probe. Portable robotic platform was developed by MSU for multi-technique high-speed NDE of CFRP test parts. The platform had two 6-axis robots, which enabled inspection of curved parts in approximately a 6×6×6 ft 3 active scan area. On the software side, the MSU team integrated scripts for NDE hardware control with scripts for robot motion control. MSU also implemented automated path planning for the robots, reconstruction of part’s surfaces via stereovision, 3D rendering of inspection data, and image processing algorithms for enhanced defect detection. Automotive composite parts manufactured by Plasan Composites from Phase I were used to validate the ACUT and EMT techniques on representative testbeds. Among those parts were three X-braces for a Dodge Viper, one composite calibration plaque with known defects at known locations, and four other test sections, including sections from a front splitter, a corner section from a composite hood, and a high-pressure RTM panel made using non crimp fabric. Other test samples included CFRP and GFRP calibration plates with fiber/matrix defects fabricated at MSU/CVRC.

36 MATERIALS SCIENCE↗

Effects of dose rate on the microstructure and deuterium retention in γ-LiAlO 2 pellets

This report presents experimental findings obtained from November 2024 to September 2025. Defect accumulation and microstructural evolution during ion irradiation at elevated temperatures are governed by two competing processes: defect production, driven by dose rate, and defect recovery, controlled by defect diffusion, interaction, and annihilation. At a given dose, the resulting microstructural evolution depends on both the dose rate and irradiation temperature. As a continuation of our FY24 tritium science project, which investigated temperature effects at a fixed dose rate, this study focuses on dose-rate effects at a fixed temperature to provide deeper insights into the irradiated microstructure and compositional changes in γ-LiAlO 2 pellets. The study aims to elucidate the impact of dose rate on microstructure, precipitate morphology, deuterium retention, and lithium volatility in γ-LiAlO 2 pellets under sequential 120 keV He + and 80 keV D 2 + ion irradiation. Three dose rates of 7.3×10 4 , 2.9×10 4 and 6.8×10 5 dpa/s were applied to achieve the same total ion fluence of 2×10 17 (He + +D + )/cm 2 at 500 °C, corresponding to a maximum combined dose of 7.55 dpa at ~255 nm. The irradiated pellets were subsequently characterized using scanning transmission electron microscopy (STEM) and time-of-flight secondary ion mass spectrometry (ToF-SIMS). The microstructural response of γ-LiAlO 2 to ion irradiation was found to be strongly dose-rate dependent. At medium and high dose rates, irradiation produced a surface amorphized layer and an underlying crystalline layer containing LiAl 5 O 8 precipitates, with implanted gases accumulating and forming blisters at the crystalline-amorphous interface. It remains to be investigated whether the amorphized layer was produced by He + ion irradiation prior to D 2 + ion irradiation. In contrast, at low dose rates, the material remained crystalline, with cavities, likely gas-filled, distributed around precipitates, within the γ-LiAlO 2 matrix, and along grain boundaries. While precipitate morphology exhibited anisotropy, their size showed little sensitivity to dose rate in the applied range of this study. This result, however, does not rule out the possibility that further reductions in dose rate could influence precipitate size. High dose-rate irradiation enhanced protonium–deuterium isotopic exchange and lithium depletion in the amorphized region. Collectively, the results show that dose rate governs amorphization, gas redistribution, isotopic exchange, and lithium depletion, providing important insights into the mechanisms underlying structural evolution in γ-LiAlO 2 pellets under reactor-relevant irradiation conditions.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Optimization of gold germanium (Au 0.17 Ge 0.83 ) thin films for high sensitivity resistance thermometry

Gold–germanium (Au x Ge 1–x ) solid solutions have been demonstrated as highly sensitive thin film thermometers for cryogenic applications. However, little is known regarding the performance of the films for thicknesses less than 100 nm. In response, here we report on the resistivity and temperature coefficient of resistance (TCR) for sputtered films with thicknesses ranging from 10 to 100 nm and annealed at temperatures from 22 to 200°C. The analysis is focused upon composition x=0.17, which demonstrates a strong temperature sensitivity over a broad range. The thinnest films are found to provide an enhancement in TCR, which approaches 20% K –1 at 10 K. Furthermore, reduced anneal temperatures are required to crystallize the Ge matrix and achieve a maximum TCR for films of reduced thickness. These features favor the application of ultra-thin films as high-sensitivity, on-device thermometers in micro- and nanolectromechanical systems.

59 BASIC BIOLOGICAL SCIENCES↗

Analysis of Interstitial Elements in Niobium with Secondary Ion Mass Spectrometry (SIMS)

Superconducting Radio Frequency (SRF) cavities provide enhanced efficiency and reduced energy utilization in present day particle accelerators. Niobium (Nb) is the material of choice for these cavities due to its high critical temperature and critical magnetic field. In order to understand why certain treatments, especially a low temperature bake, improve performance, it is important to study Nb surface characteristics and identify elemental contamination that can affect the performance of the cavity. H, C, O, and N are of interest because they are interstitial impurities in Nb. In earlier work, SIMS analysis using a CAMECA IMS-6F with Cs+ primary beam showed that C and N were probably not significant factors impacting performance but there was a very high level of H in the Nb. Ion implants of C, N, O, and D into Nb provided quantification of C, N, O and indicated that D is very mobile in the Nb. Further analyses showed that heat treated Nb has lower levels of surface H than non heat treated Nb and subsequent removal of surface oxide by etching causes intake of H in a heat treated Nb sample. This result helps confirm the role of surface oxide as a hydrogen barrier. To further understand the oxide, Nb samples were anodized to obtain a thicker surface oxide and H and D were implanted into this oxide to check for the appearance of implant peaks. SIMS depth profile analyses were carried out and confirmed the presence of the implant shape for these elements in the oxide. Relative Sensitivity Factor (RSFs) could then be calculated for quantification of H in the oxide. Since the Nb matrix signal showed little change from the oxide to the substrate, the same RSF was used to estimate the H concentration in the Nb at 2×1022 atoms/cm3 (approximately 40% mole fraction H).

43 PARTICLE ACCELERATORS↗