Search NASA⌕ Search

SEARCH · Search NASA

Results for “Separation Service”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Clustering Method and Representative Feeder Selection for the California Solar Initiative

The screening process for DG interconnection procedures needs to be improved in order to increase the PV deployment level on the distribution grid. A significant improvement in the current screening process could be achieved by finding a method to classify the feeders in a utility service territory and determine the sensitivity of particular groups of distribution feeders to the impacts of high PV deployment levels. This report describes the utility distribution feeder characteristics in California for a large dataset of 8,163 feeders and summarizes the California feeder population including the range of characteristics identified and most important to hosting capacity. The report describes the set of feeders that are identified for modeling and analysis as well as feeders identified for the control group. The report presents a method for separating a utility's distribution feeders into unique clusters using the k-means clustering algorithm. An approach for determining the feeder variables of interest for use in a clustering algorithm is also described. The report presents an approach for choosing the feeder variables to be utilized in the clustering process and a method is identified for determining the optimal number of representative clusters.

14 SOLAR ENERGY↗

Overview of Fish Passage Facilities at Hydropower Developments across the Conterminous United States

This dataset contains geo-referenced information on the presence and types of fish passage facilities at hydropower developments across the conterminous United States (CONUS) presented in the ORNL Hydropower Fish Passage Database Webmap (https://www.ornl.gov/project/quantifying-national-fish-passage-data/webmap). It was developed through collaborative partnerships with fish passage engineers and biologists at both the US Fish and Wildlife Service (USFWS) and the National Marine Fisheries Service (NMFS), and hydropower experts at the Low Impact Hydropower Institute (LIHI). Information contained within this dataset has been provided by many different sources, including State and Federal resource management agencies, non-governmental organizations, hydropower industry members, and published datasets=. This dataset is intended to provide a high-level overview of the distribution of fish passage infrastructure at hydropower developments across CONUS; a more comprehensive database is anticipated to be released later in 2025. This dataset contains one data file in comma-separate (*.csv) format and the information within it was last updated on 24 March 2025.

13 HYDRO ENERGY↗

Processed Soil Respiration at the TRACE experimental Warming project, Aug 2015 - Sep 2017, Sabana, Luquillo, Puerto Rico

This data package contains processed measurements of soil carbon dioxide (CO₂) efflux collected using LI-COR LI-8100 soil respiration chambers at the Tropical Responses to Altered Climate Experiment (TRACE) located at the Sabana Field Research Station near Luquillo, Puerto Rico. The TRACE site is a mature, closed-canopy tropical wet forest within the Luquillo Experimental Forest. These data quantify soil surface CO₂ fluxes from both ambient (control) and experimentally warmed plots to evaluate how long-term soil warming affects belowground carbon cycling in tropical ecosystems. The data files include time-series tables of CO₂ flux (µmol CO₂ m⁻² s⁻¹), soil temperature (°C), and ancillary environmental variables, stored in comma-separated values (CSV) format and viewable with any text editor, spreadsheet, or statistical software (e.g., R, Python, Excel). Associated metadata describe plot identifiers, measurement intervals, and processing steps. These data were generated to address the research question: How does sustained soil warming influence soil respiration and carbon flux dynamics in tropical wet forests?

54 ENVIRONMENTAL SCIENCES↗

COMPASS-FME Synoptic Sites Level 1 Sensor Data v1-2

This is the version 1-2 Level 1 (L1) data release for COMPASS-FME environmental sensors located at our synoptic field sites. COMPASS-FME is studying sites in two distinct regions, the Chesapeake Bay and the Western Lake Erie Basin. We established the network at seven "synoptic" (observational) sites along the Chesapeake Bay and Lake Erie coastlines, collectively generating over three million observations per month, to track and comprehend environmental changes where land and water intersect. Additionally, the two regions provide an interesting contrast of saltwater and freshwater coasts that allow us to differentiate the impacts of inundation and coastal water chemistries in two nationally important coastal systems.L1 data are close to raw, but are units-transformed and have out-of-instrument-bounds and out-of-service flags added. Duplicates and missing data are removed but otherwise these data are not filtered, and have not been subject to any additional algorithmic or human QA/QC. Any scientific analyses of L1 data should be performed with care. **This dataset will be updated quarterly with new data for the duration of the project**This dataset includes:- An overall dataset README file that describes the current version, gives citation and contact information, etc.- Site- and year-specific folders, each holding up to 12 CSV (comma separated value) data files for each site and plot in that year.- Metadata files within each site-year folder provide full information on data units, expected ranges, contact information, as well as a general description of the site.- Environmental sensor types that appear in the data files include weather (ClimaVUE50, CS, RM Young, and LI instruments in the graphs below); soil conditions (TEROS12); soil redox state (Redox); groundwater variables (AquaTROLL200 and AquaTROLL600); open water sondes (Exo); tree sap velocity (Sapflow); and system voltage and state (Datalogger). Data are normally logged every 15 minutes. Please see v1-2 Synoptic L1 Sensor Package Quick Start.pdf for detailed information on data package structure, temporal coverage, and versioning.

54 ENVIRONMENTAL SCIENCES↗

COMPASS-FME Terrestrial Ecosystem Manipulation to Probe the Effects of Storm Treatments (TEMPEST) Experiment Level 1 Sensor Data v1-2

This is the version 1-2 Level 1 (L1) data release for COMPASS-FME environmental sensors located at our Terrestrial Ecosystem Manipulation to Probe the Effects of Storm Treatments (TEMPEST) experimental site. This manipulative, ecosystem-scale TEMPEST experiment addresses the potential for freshwater and estuarine-water disturbance events to alter tree function, species composition, and ecosystem processes in a deciduous coastal forest in MD, USA. The experiment uses a large-unit (2000 m2), un-replicated experimental design, with three 50 m × 40 m plots serving as control, freshwater, and estuarine-water treatments.L1 data are close to raw, but are units-transformed and have out-of-instrument-bounds and out-of-service flags added. Duplicates and missing data are removed but otherwise these data are not filtered, and have not been subject to any additional algorithmic or human QA/QC. Any scientific analyses of L1 data should be performed with care. **This dataset will be updated quarterly with new data for the duration of the project**This dataset includes:- An overall dataset README file that describes the current version, gives citation and contact information, etc.- Site- and year-specific folders, each holding up to 12 CSV (comma separated value) data files for each site and plot in that year.- Metadata files within each site-year folder provide full information on data units, expected ranges, contact information, detailed flood times, as well as a general description of the site.- Environmental sensor types that appear in the data files include weather (ClimaVUE50, CS, RM Young, and LI instruments in the graphs below); soil conditions (TEROS12); soil redox state (Redox); groundwater variables (AquaTROLL200 and AquaTROLL600); open water sondes (Exo); tree sap velocity (Sapflow); and system voltage and state (Datalogger). Data are normally logged every 15 minutes.Please see v1-2 TEMPEST L1 Sensor Package Quick Start.pdf for detailed information on data package structure, temporal coverage, and versioning.The TEMPEST flood events occurred on the following dates. They lasted for ~10 hours each day and delivered ~80,000 gallons to each plot; many data streams are available at 1 or 5 minute frequency during these periods.* Tests: Aug 25 (fresh plot) and Sep 9 (salt plot), 2021* TEMPEST 1: June 22, 2022* TEMPEST 2: June 6-7, 2023* TEMPEST 3: June 11-13, 2024

54 ENVIRONMENTAL SCIENCES↗

Experimental Evaluation of High Performance Integrated Heat Pump

Integrated heat pump (IHP) technology provides significant potential for energy savings and comfort improvement for residential buildings. In this study, we evaluate the performance of a high performance IHP that provides space heating, cooling, and water heating services. Experiments were conducted according to the ASHRAE Standard 206-2013 where 24 test conditions were identified in order to evaluate the IHP performance indices based on the airside performance. Empirical curve fits of the unit s compressor maps are used in conjunction with saturated condensing and evaporating refrigerant conditions to deduce the refrigerant mass flowrate, which, in turn was used to evaluate the refrigerant side performance as a check on the airside performance. Heat pump (compressor, fans, and controls) and water pump power were measured separately per requirements of Standard 206. The system was charged per the system manufacturer s specifications. System test results are presented for each operating mode. The overall IHP performance metrics are determined from the test results per the Standard 206 calculation procedures.

Miller, William A↗

Performance of Compact Pulsed Thermal Imaging System for In-Service Applications. Pulsed thermal tomography nondestructive examination of additively manufactured reactor materials and components

Additive manufacturing (AM) is an emerging method for cost-efficient fabrication of complex topology nuclear reactor parts from high-strength corrosion resistance alloys, such as stainless steel and Inconel. AM of metallic structures for nuclear energy applications is currently based on laser powder bed fusion (LPBF) process, which has the capability of melting metallic powder and net shaping the structures with relatively high precision. Some of the challenges with using LPBF method for nuclear manufacturing include the possibility of introducing pores into metallic structures. Integrity of AM structures needs to be evaluated nondestructively because material flaws could lead to premature failures due to creep in high temperature nuclear reactor environment. Currently, there exist limited capabilities to evaluate actual AM structures nondestructively. Pulsed Thermography (PT) imaging provides a capability for non-destructive evaluation (NDE) of sub-surface defects in arbitrary size structures. The PT method is based on recording material surface temperature transients with infrared (IR) camera following thermal pulse delivered on material surface with flash light. The PT method has advantages for NDE of actual AM structures because the method involves one-sided non-contact measurements and fast processing of large sample areas captured in one image. The data cube of PT measurements consists of surface temperature taken at sequential time intervals T(x,y,t). Material defects can be detected either by analyzing the thermograms T(x,y,t) data cube, or by using thermal tomography (TT) algorithm to obtain 3D spatial reconstruction of thermal effusivity e(x,y,z). To reduce the cost and enable in-service NDE in spatially constrained environment, it is highly desirable to develop PT with compact and inexpensive IR camera. Following initial qualification of an AM component for deployment in a nuclear reactor, a compact PT system can also be used for in-service nondestructive evaluation (NDE) applications. However, data cube obtained with PT based on compact IR camera suffers from strong thermal noises and loss of features due to relatively low sampling rate. In this report we describe two unsupervised machine learning (ML) algorithms for enhancement of PT images obtained with compact IR camera. In one approach, we introduce Sparse Coding Discrete Cosine Transform (SC/DCT) algorithm to remove additive white Gaussian noise (AWGN) from spatial thermal effusivity reconstructions. In another approach we introduce a Spatial Temporal Denoised Thermal Source Separation (STDTSS) ML algorithm to process thermograms. The STDTSS algorithm consists of spatial and temporal denoising using Gaussian and Savitzky–Golay filtering, followed by the matrix decomposition using Principal Component Analysis (PCA), and Independent Component Analysis (ICA) to automatically detect flaws. In the work described in this report, we constructed a compact PT system using a relatively small and low-cost FLIR A65 camera, consisting on uncooled microbolometer detector. Performance of SC/DCT algorithm was demonstrated on enhancing TT images of Inconel 718 AM plate. Performance of the STDTSS methods was investigated using thermography data obtained from imaging stainless steel 316L specimens produced with LPBF method with imprinted calibrated porosity defects.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

COMPASS-FME Synoptic Sites Level 1 Sensor Data v2-1

This is the version 2-1 Level 1 (L1) data release for COMPASS-FME environmental sensors located at our synoptic field sites. COMPASS-FME is studying sites in two distinct regions, the Chesapeake Bay and the Western Lake Erie Basin. We established the network at seven "synoptic" (observational) sites along the Chesapeake Bay and Lake Erie coastlines, collectively generating over three million observations per month, to track and comprehend environmental changes where land and water intersect. Additionally, the two regions provide an interesting contrast of saltwater and freshwater coasts that allow us to differentiate the impacts of inundation and coastal water chemistries in two nationally important coastal systems. L1 data are close to raw, but are units-transformed and have out-of-instrument-bounds, out-of-service, and outlier flags added. Duplicates and missing data are removed but otherwise these data are not filtered, and have not been subject to any additional algorithmic or human QA/QC. Any scientific analyses of L1 data should be performed with care. **This dataset will be updated quarterly with new data for the duration of the project** This dataset includes: - An overall dataset README file that describes the current version, gives citation and contact information, etc. - Site- and year-specific folders, each holding up to 12 CSV (comma separated value) data files for each site and plot in that year. - Metadata files within each site-year folder provide full information on data units, expected ranges, contact information, as well as a general description of the site. - Environmental sensor types that appear in the data files include weather (ClimaVUE50, CS, RM Young, and LI instruments in the graphs below); soil conditions (TEROS12); soil redox state (Redox); groundwater variables (AquaTROLL200 and AquaTROLL600); open water sondes (Exo); tree sap velocity (Sapflow); and system voltage and state (Datalogger). Data are normally logged every 15 minutes. Please see v2-0 Synoptic L1 Sensor Package Quick Start.pdf for detailed information on data package structure, temporal coverage, and versioning. This dataset was updated 2026-03-12: (i) data now go through 2025-12-31 (previous end was 2025-06-30) and (ii) dataset and file names updated to “…v2-1” (previously was “v2-0”).

54 ENVIRONMENTAL SCIENCES↗

COMPASS-FME Terrestrial Ecosystem Manipulation to Probe the Effects of Storm Treatments (TEMPEST) Experiment Level 1 Sensor Data v2-1

This is the version 2-1 Level 1 (L1) data release for COMPASS-FME environmental sensors located at our Terrestrial Ecosystem Manipulation to Probe the Effects of Storm Treatments (TEMPEST) experimental site. This manipulative, ecosystem-scale TEMPEST experiment addresses the potential for freshwater and estuarine-water disturbance events to alter tree function, species composition, and ecosystem processes in a deciduous coastal forest in MD, USA. The experiment uses a large-unit (2000 m2), un-replicated experimental design, with three 50 m × 40 m plots serving as control, freshwater, and estuarine-water treatments. L1 data are close to raw, but are units-transformed and have out-of-instrument-bounds, out-of-service, and outlier flags added. Duplicates and missing data are removed but otherwise these data are not filtered, and have not been subject to any additional algorithmic or human QA/QC. Any scientific analyses of L1 data should be performed with care. **This dataset will be updated quarterly with new data for the duration of the project** This dataset includes: - An overall dataset README file that describes the current version, gives citation and contact information, etc. - Site- and year-specific folders, each holding variable-specific CSV (comma separated value) data files for each site and plot in that year. - Metadata files within each site-year folder provide full information on data units, expected ranges, contact information, detailed flood times, as well as a general description of the site. - Environmental sensor types that appear in the data files include weather (ClimaVUE50, CS, RM Young, and LI instruments in the graphs below); soil conditions (TEROS12); soil redox state (Redox); groundwater variables (AquaTROLL200 and AquaTROLL600); open water sondes (Exo); tree sap velocity (Sapflow); and system voltage and state (Datalogger). Data are normally logged every 15 minutes. Please see v2-1 TEMPEST L1 Sensor Package Quick Start.pdf for detailed information on data package structure, temporal coverage, and versioning. The TEMPEST flood events occurred on the following dates. They lasted for ~10 hours each day and delivered ~80,000 gallons to each plot; many data streams are available at 1 or 5 minute frequency during these periods. * Tests: Aug 25 (fresh plot) and Sep 9 (salt plot), 2021 * TEMPEST 1: June 22, 2022 * TEMPEST 2: June 6-7, 2023 * TEMPEST 3: June 11-13, 2024 This dataset was updated 2026-03-12: (i) data now go through 2025-12-31 (previous end was 2025-06-30) and (ii) dataset and file names updated to “…v2-1” (previously was “v2-0”).

54 ENVIRONMENTAL SCIENCES↗

Corrosion impact of reductant on DWPF and downstream facilities

Glycolic acid is being evaluated as an alternate reductant in the preparation of high level waste for the Defense Waste Processing Facility (DWPF) at the Savannah River Site (SRS). During processing, the glycolic acid is not completely consumed and small quantities of the glycolate anion are carried forward to other high level waste (HLW) facilities. The impact of the glycolate anion on the corrosion of the materials of construction throughout the waste processing system has not been previously evaluated. A literature review had revealed that corrosion data in glycolate-bearing solution applicable to SRS systems were not available. Therefore, testing was recommended to evaluate the materials of construction of vessels, piping and components within DWPF and downstream facilities. The testing, conducted in non-radioactive simulants, consisted of both accelerated tests (electrochemical and hot-wall) with coupons in laboratory vessels and prototypical tests with coupons immersed in scale-up and mock-up test systems. Eight waste or process streams were identified in which the glycolate anion might impact the performance of the materials of construction. These streams were 70% glycolic acid (DWPF feed vessels and piping), SRAT/SME supernate (Chemical Processing Cell (CPC) vessels and piping), DWPF acidic recycle (DWPF condenser and recycle tanks and piping), basic concentrated recycle (HLW tanks, evaporators, and transfer lines), salt processing (ARP, MCU, and Saltstone tanks and piping), boric acid (MCU separators), and dilute waste (HLW evaporator condensate tanks and transfer line and ETF components). For each stream, high temperature limits and worst-case glycolate concentrations were identified for performing the recommended tests. Test solution chemistries were generally based on analytical results of actual waste samples taken from the various process facilities or of prototypical simulants produced in the laboratory. The materials of construction for most vessels, components and piping were not impacted with the presence of glycolic acid or the impact is not expected to affect the service life. However, the presence of the glycolate anion was found to affect corrosion susceptibility of some materials of construction in the DWPF and downstream facilities, especially at elevated temperatures. The following table summarizes the results of the electrochemical and hot wall testing and indicates expected performance in service with the glycolate anion present.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Recovery Act - Sustainable Transportation: Advanced Electric Drive Vehicle Education Program

The collective goals of this effort include: 1) reach all facets of this society with education regarding electric vehicles (EV) and plug–in hybrid electric vehicles (PHEV), 2) prepare a workforce to service these advanced vehicles, 3) create web–based learning at an unparalleled level, 4) educate secondary school students to prepare for their future and 5) train the next generation of professional engineers regarding electric vehicles. The Team provided an integrated approach combining secondary schools, community colleges, four–year colleges and community outreach to provide a consistent message (Figure 1). Colorado State University Ventures (CSUV), as the prime contractor, plays a key program management and co–ordination role. CSUV is an affiliate of Colorado State University (CSU) and is a separate 501(c)(3) company. The Team consists of CSUV acting as the prime contractor subcontracted to Arapahoe Community College (ACC), CSU, Motion Reality Inc. (MRI), Georgia Institute of Technology (Georgia Tech) and Ricardo. Collaborators are Douglas County Educational Foundation/School District and Gooru (www.goorulearning.org), a nonprofit web–based learning resource and Google spin–off.

Caille, Gary↗

Study of metallic materials for solid oxide fuel cell interconnect applications.

Metallic interconnect acts as a gas separator and a gas distributor and therefore, it needs to function adequately in two widely different environments. The interconnect material will be exposed to air on one side and natural gas or coal-derived synthesis gas on the other side. The viable material for the interconnect application must be resistant not only to oxidation but also carburization in hydrocarbon containing low-oxygen environments. In addition, the scales that develop on the exposed surfaces must possess adequate electrical conductivity for them to function as current leads over long service life of the fuel cell. This report addresses five topics of interest for the development of metallic interconnects with adequate performance in fuel cells for long service life. The research conducted over the years and the conclusions reached were used to identify additional areas of research on materials for improved performance of components, especially metallic interconnects, in the complex fuel cell environments. This report details research conducted in the following areas: measurement of area specific electrical resistivity, corrosion performance in dual gas environments by experiments using alloy 446, long term corrosion performance of ferritic and austenitic alloys in hydrogen and methane-reformed synthesis fuel-gas environments, approaches to reduce the area resistance of metallic interconnect, and reduction of electrical resistivity of alumina scales on metallic interconnect. Based on the key requirements for metallic interconnects and the data developed on the corrosion behavior of candidate materials in meeting those requirements, several areas are recommended for further research to develop metallic interconnects with acceptable and reliable long-term performance in solid oxide fuel cells.

03 NATURAL GAS↗

Enhancing Complex System Performance Using Discrete-Event Simulation

In this paper, we utilize discrete-event simulation (DES) merged with human factors analysis to provide the venue within which the separation and deconfliction of the system/human operating principles can occur. A concrete example is presented to illustrate the performance enhancement gains for an aviation cargo flow and security inspection system achieved through the development and use of a process DES. The overall performance of the system is computed, analyzed, and optimized for the different system dynamics. Various performance measures are considered such as system capacity, residual capacity, and total number of pallets waiting for inspection in the queue. These metrics are performance indicators of the system's ability to service current needs and respond to additional requests. We studied and analyzed different scenarios by changing various model parameters such as the number of pieces per pallet ratio, number of inspectors and cargo handling personnel, number of forklifts, number and types of detection systems, inspection modality distribution, alarm rate, and cargo closeout time. The increased physical understanding resulting from execution of the queuing model utilizing these vetted performance measures identified effective ways to meet inspection requirements while maintaining or reducing overall operational cost and eliminating any shipping delays associated with any proposed changes in inspection requirements. With this understanding effective operational strategies can be developed to optimally use personnel while still maintaining plant efficiency, reducing process interruptions, and holding or reducing costs.

42 ENGINEERING↗

Major Achievements of the Springfields Decommissioning Program - 16512

Since the 1940's, Springfields has manufactured fuel products for the UK's nuclear power stations and for international customers. The early operations were in support of the atomic weapons program, closely followed by fuel manufacture for electricity generation via the Magnox power stations commencing in the late 1950's. In 2005, responsibility for the assets and liabilities of Springfields was transferred to the Nuclear Decommissioning Authority (NDA). A new company, Springfields Fuels Limited, was created to run the site, which was managed and operated by Westinghouse Electric UK Ltd on the NDA's behalf. On April 1, 2010, Westinghouse entered into an agreement with the NDA for a long-term lease of the Springfields site, which transferred responsibility for the commercial fuel manufacturing business and Springfields Fuels Limited to Westinghouse. Today, the main Springfields activities include: - Oxide fuels for Advanced Gas-cooled and Light Water Reactors, as well as intermediate fuel products, such as powders, granules and pellets, - Manufacture of Uranium Hexafluoride (now in Care and Maintenance), - Processing and recovery of Uranium residues, - Decommissioning and demolition of redundant plants and buildings. Some 120 plant buildings and support facilities have been successfully decommissioned and demolished in the period 1996 to date. These range from 1940's buildings, subsequently converted for nuclear fuel manufacture, together with some of the formerly sealed chemical agent manufacture and storage facilities. Decommissioning of the now redundant Magnox manufacturing facilities is ongoing at Springfields without compromising the other site operations. Westinghouse is managing all activities related to the whole lifecycle, planning, design, safety case, radiation protection, Post Operational Clean Out (POCO), service diversions, characterization, decommissioning all phases through to ground remediation, waste disposal and agreed end states. Decommissioning of process plants starts with the removal of the majority of radiological activity or hazard contained within the plant. This is known as Post Operational Clean Out. Once this is complete, the plant may be dismantled. Work is scoped and defined within packages (at plant or cell level) to aid control and commercial monitoring as the decommissioning is progressed. This package approach also enables clean or lightly contaminated items to be removed separately to aid potential re-cycling and minimize decontamination and waste disposal costs. Westinghouse is further optimising work package delivery by planning parallel POCO and Decommissioning work phases within plant at a cell level to systematically remove redundant plant and reduce hazard earlier, whilst optimising use of both internal and external resources to reduce total project cost. Waste and Residues from all phases are disposed of via authorized disposal routes and in accordance with our environmental authorizations. On completion of decommissioning and removal of plant and equipment the building is re-assessed radiologically, categorized and appropriate remediation work progressed to render it safe for conventional demolition. The major elements of the success achieved to date can be attributed to the following elements: - Overall programme management with extensive experience of planning, cost, and risk management. Integration of the programme within a major commercial site without compromising safety or operations. - Complete site EHS management working within a complex regulatory framework including the Nuclear Site Licenses, Environmental Authorisations and Security requirements. - Avoiding safety complacency by use of rigorous and systematic process to emphasise safety over competing goals. Including structured use of Human Performance and Corrective Action and Learning processes. - Unique safety experiences attained through complex hazard reduction across a broad range of uranium manufacturing and chemical hazard/agent facilities. - Project leadership and excellence utilizing a core site team to deploy repeatable processes and safe practices to deliver complex scope within budget and schedule. - Optimised use of internal and external resources, with extensive use of Operating Experience to drive continuous improvement and problem resolution. - Management of Contractors from initial selection, pre-qualification, tender assessment and Performance using varied contract forms across delivery phases. - Use of Westinghouse expertise for safety case, waste management, uranium recovery, health physics and design. - Implementation of a work package to ensure gated discreet manageable packages. Underpinned by package specific method statements, with appropriate hold points to maintain management and control of the works. - Continuous local safety focus via safety planning, induction, plant specific training, proactive risk assessment, and a defined approach to decoupling operating plant safety cases enabling focussed and usable documentation. This paper will provide an overview of the latest decommissioning activities achieved on the Springfields site and will focus on best practices that allowed Westinghouse to maintain the program on time and on budget. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Optimization of a Lethal, Combat-Relevant Model of Sterile Inflammation in Mice for Drug Candidate Screening

ABSTRACT Introduction Extensive trauma, commonly seen in wounded military Service Members, often leads to a severe sterile inflammation termed systemic inflammatory response syndrome (SIRS), which can progress to multiple organ dysfunction syndrome (MODS) and death. MODS is a serious threat to wounded Service Members, historically causing 10% of all deaths in trauma admissions at a forward deployed combat hospital. The importance of this problem will be exacerbated in large-scale combat operations, in which evacuation will be delayed and care of complex injuries at lower echelons of care may be prolonged. The main goal of this study was to optimize an existing mouse model of lethal SIRS/MODS as a therapeutic screening platform for the evaluation of immunomodulatory drugs. Materials and Methods Male C57BL/6 mice were euthanized, and the bones and muscles were collected and blended into a paste termed tissue–bone matrix (TBX). The TBX at 12.5%–20% relative to body weight of each recipient mouse was implanted into subcutaneous pouches created on the dorsum of anesthetized animals. Mice were observed for clinical scores for up to 48 hours postimplantation and euthanized at the preset point of moribundity. To test effects of anesthetics on TBX-induced mortality, animals received isoflurane or ketamine/xylazine (K/X). In a separate set of studies, mice received TBX followed by intraperitoneal injection with 20 mg/kg or 40 mg/kg Eritoran or a placebo carrier. All Eritoran studies were performed in a blinded fashion. Results We observed that K/X anesthesia significantly increased the lethality of the implanted TBX in comparison to inhaled anesthetics. Although all the mice anesthetized with isoflurane and implanted with 12.5% TBX survived for 24 hours, 60% of mice anesthetized with K/X were moribund by 24 hours postimplantation. To mimic more closely the timing of lethal SIRS/MODS following polytrauma in human patients, we extended observation to 48 hours. We performed TBX dose–response studies and found that as low as 15%, 17.5%, and 20% TBX caused moribundity/mortality in 50%, 80%, and 100% mice, respectively, over a 48-hour time period. With 17.5% TBX, we tested if moribundity/mortality could be rescued by anti-inflammatory drug Eritoran, a toll-like receptor 4 antagonist. Neither 20 mg/kg nor 40 mg/kg doses of Eritoran were found to be effective in this model. Conclusions We optimized a TBX mouse model of SIRS/MODS for the purpose of evaluating novel therapeutic interventions to prevent trauma-related pathophysiologies in wounded Service Members. Negative effects of K/X on lethality of TBX should be further evaluated, particularly in the light of widespread use of ketamine in treatment of pain. By mimicking muscle crush, bone fracture, and necrosis, the TBX model has pleiotropic effects on physiology and immunology that make it uniquely valuable as a screening tool for the evaluation of novel therapeutics against trauma-induced SIRS/MODS.

General & Internal Medicine↗

Component Test Facility (Comtest) Phase 1 Engineering For 760°C (1400°F) Advanced Ultrasupercritical (A-USC) Steam Generator Development

The Babcock & Wilcox Company (B&W) performed a Pre-Front End Engineering Design (Pre-FEED) of an A-USC steam superheater for a proposed component test program achieving 760°C (1400°F) steam temperature. This would lead to follow-on work in a Phase 2 and Phase 3 that would involve detail design, manufacturing, construction and operation of the ComTest. Phase 1 results have provided the engineering data necessary for proceeding to the next phase of ComTest. The steam generator superheater would subsequently supply the steam to an A-USC prototype intermediate pressure steam turbine. The ComTest program is important in that it will place functioning A-USC components in operation and in coordinated boiler and turbine service. It is also important to introduce the power plant operation and maintenance personnel to the level of skills required and provide the first background experience with hands-on training. The project will provide a means to exercise the complete supply chain events required in order to practice and perfect the process for A-USC power plant design, supply, manufacture, construction, commissioning, operation and maintenance. Representative participants will then be able to transfer knowledge and recommendations to the industry. ComTest is conceived in the manner of using a separate standalone plant facility that will not jeopardize the host facility or suffer from conflicting requirements in the host plant’s mission that could sacrifice the nickel alloy components and not achieve the testing goals. ComTest will utilize smaller quantities of the expensive materials and reduce the risk in the first operational practice for A-USC technology in the United States. Components at suitable scale in ComTest provide more assurance before putting them into practice in the full size A-USC demonstration plant.

20 FOSSIL-FUELED POWER PLANTS↗

Evaluation of a Fish Passage Site in the Walla Walla River Basin, 2009 Annual Report : September 2008 - August 2009.

In 2009, Pacific Northwest National Laboratory (PNNL) evaluated the Touchet Consolidated Facility to determine if it is designed, constructed, operated, and maintained to effectively provide juvenile salmonids with safe passage past the diversion and back to the Touchet River. Completed in 2008, the Touchet Consolidated Facility combined two irrigation diversions with an existing intake for the Touchet Acclimation Facility. The consolidated facility includes a separate fish screen and intake for each user, a pool and chute fishway, and an adult fish trap. The fish screens portions of the facility were evaluated on April 20, 2009, using underwater videography, acoustic Doppler velocimeter measurements, and visual observations while water was diverted to the acclimation facility alone and again as water was diverted to the irrigation system and pond together. The facility is in good condition and is well maintained, although water velocities within the site do not meet the criteria set by the National Marine Fisheries Service (NMFS). Approach velocities above 0.4 ft/s at the upstream end of the facility and decreases in sweep velocity toward the bypass are likely caused by the proximity of the upstream screen to the spill over stoplogs that control flow at the upstream end of the forebay. We recommend working with Touchet Acclimation Facility staff to try different configurations and heights of forebay stoplogs while PNNL staff measure water velocities, allowing real-time monitoring of changes in approach and sweep velocities resulting from the configuration changes. It may be possible to bring approach and sweep velocities more in line with the NMFS criteria for juvenile fish screens. We also recommend evaluating the facility later in the year when river levels are low and the irrigation district is the only water user. During the site visit, it was noted that the upstream end of the fishway has relatively closely spaced louvers that point downstream. During higher river levels such as on April 20, the orientation of the louvers causes a headloss of up to 1 ft or more. Fish must maneuver through this hydraulic jump and between the louvers. The Washington Department of Fish and Wildlife is considering alternatives to this configuration; if needed, we would be available to offer technical assistance.

13 HYDRO ENERGY↗

A Novel Three-Phase Oak Ridge AC / AC Converter for Wireless Mobility Energy Storage System (WMESS) Connectivity

In this study, a novel three-phase Oak Ridge ac to ac converter is introduced for wireless mobility energy storage system (WMESS) applications for grid support or ancillary service applications. The proposed topology can be used in bidirectional operation between ac grid and ac terminals of energy storage (output of the ESS inverter) by accomplishing unity power factor. Inherent merit of the technology is that it can directly merge ac input 60 Hz grid frequency with the high frequency by superimposing them with the Oak Ridge Converter (ORC) and through the wireless coils. Theoretical and simulation results are provided for 10 kW output power. The functionality of the proposed three-phase system is demonstrated with the coupling coils separated by 6 inches of air gap with the input / output of 277 V AC,RMS . The system overall design is presented, and simulation results demonstrate achieving 3% current total harmonic distortion (THD) and 0.99 power factor (PF) at full load of 10 kW wireless power transfer.

Asa, Erdem↗