At least 289 records · Page 16

Positron-electron annihilation radiation from the Galactic Center

Evidence and arguments are presented supporting the theory that the 0.511 MeV line observed from the Galactic Center stems from photon-photon pair production near a black hole with a mass not greater than approximately 500 solar masses. Observations are reviewed and the subsequent implications on the annihilation site and the positron source are discussed. Because of the variations and line width of the e(+) - e(-) annihilation radiation from the Galactic Center, positrons must essentially be produced by a single source and annihilate in an ambient gas of density greater than 10 to the 5th/cu cm, an ionization fraction greater than 10 percent, a temperature less than 5 x 10 to the 4th K, and be confined to a region of size less than 10 to the 18th cm. Such conditions may exist in warm clouds and other IR sources within the central parsec of the Galaxy.

Ramaty, R.↗

Observation of Long-Lived UV-Induced Fluorescence from Environmental Materials Using the HVeV Detector as Developed for SuperCDMS

Here, we describe recent experiments using a SuperCDMS HVeV single-charge sensitive detector illuminated with an ultraviolet LED (275 nm) and a monochromatic laser(650 nm) using a dual fiber optic system installed in a small dilution refrigerator at Stanford University. We observed a population of fluorescence background events after UV exposure but not after exposure to the laser source. The fluorescence was likely due to scattered UV photons absorbed outside the detector. We discuss the possibility of fluorescence being a contributor to the low energy excess background observed in above-ground Dark Matter experiments.

36 MATERIALS SCIENCE↗

Intensified Tpx3Cam, a fast data-driven optical camera with nanosecond timing resolution for single photon detection in quantum applications

Here we describe a fast data-driven optical camera, Tpx3Cam, with nanosecond scale timing resolution and 80 Mpixel/sec throughput. After the addition of intensifier, the camera is single photon sensitive with quantum efficiency determined primarily by the intensifier photocathode. The single photon performance of the camera was characterized with results on the gain, timing resolution and afterpulsing reported here. The intensified camera was successfully used for measurements in a variety of applications including quantum applications. As an example of such application, which requires simultaneous detection of multiple photons, we describe registration of photon pairs from the spontaneous parametric down-conversion source in a spectrometer. We measured the photon wavelength and timing with respective precisions of 0.15 nm and 3 ns, and also demonstrated that the two photons are anti-correlated in energy.

79 ASTRONOMY AND ASTROPHYSICS↗

Development of High Quantum Efficiency UV/Blue Photocathode Epitaxial Semiconductor Heterostructures for Scintillation and Cherenkov Radiation Detection

The primary goal of this research project was to further extend the use of advanced heteroepitaxial-semiconductor crystal growth techniques such as molecular beam epitaxy (MBE) and to demonstrate significant gains in UV/blue photonic detection by designing and fabricating atomically-tailored heteroepitaxial GaAlN/GaInN photocathode device structures. This NASA Explorer technology research program has focused on the development of photocathodes for Cherenkov and scintillation radiation detection. Support from the program allowed us to enhance our MBE system to include a nitrogen plasma source and a magnetic bearing turbomolecular pump for delivery and removal of high purity atomic nitrogen during GaAlN/GaInN film growth. Under this program we have also designed, built and incorporated a cesium activation stage. In addition, a connected UHV chamber with photocathode transfer/positioner components as well as a hybrid phototube stage was designed and built to make in-situ quantum efficiency measurements without ever having to remove the photocathodes from UHV conditions. Thus we have constructed a system with the capability to couple atomically-tailored MBE-grown photocathode heterostructures with real high gain readout devices for single photon detection evaluation.

Leopold, Daniel J.↗

Prospects for experimental research on black holes in binary systems

Cygnus X-1, the single widely accepted example of a black hole in a binary system, is characterized by unusual X-ray properties. The X-ray spectrum of Cygnus X-1 is not cut off above 20 keV, as in most strong X-ray sources. Recent scintillation counter measurements reveal a power law spectrum extending from 40 to 200 keV with a photon spectral index of approximately 2.2. However, it is not clear that these and other X-ray properties of the system are related to the black-hole nature of Cygnus X-1. It is suggested that without a direct test to show that the mass of the compact object in other systems similar to Cygnus X-1 (Circinus X-1 and GX339-4) exceeds the limit of the neutron star mass, a better understanding of the accretion disk phenomenon must be achieved to demonstrate how the properties peculiar to these systems are related to the black hole nature of the compact object. Current accretion disk models are examined, including the alpha-accretion disk and two-temperature accretion disk models.

Long, K. S.↗

Classical Simulation of Boson Sampling Based on Graph Structure

Boson sampling is a fundamentally and practically important task that can be used to demonstrate quantum supremacy using noisy intermediate-scale quantum devices. In this Letter, we present classical sampling algorithms for single-photon and Gaussian input states that take advantage of a graph structure of a linear-optical circuit. The algorithms’ complexity grows as so-called treewidth, which is closely related to the connectivity of a given linear-optical circuit. Using the algorithms, we study approximated simulations for local Haar-random linear-optical circuits. For equally spaced initial sources, we show that, when the circuit depth is less than the quadratic in the lattice spacing, the efficient simulation is possible with an exponentially small error. Notably, right after this depth, photons start to interfere each other and the algorithms’ complexity becomes subexponential in the number of sources, implying that there is a sharp transition of its complexity. Finally, when a circuit is sufficiently deep enough for photons to typically propagate to all modes, the complexity becomes exponential as generic sampling algorithms. We numerically implement a likelihood test with a recent Gaussian boson sampling experiment and show that the treewidth-based algorithm with a limited treewidth renders a larger likelihood than the experimental data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Electron-beam-based Compton scattering x-ray source for probing high-energy-density physics

The physics basis for an electron-beam-based Compton scattering x-ray source is investigated for single-shot experiments at the major high-energy-density facilities, such as the Omega Laser Facility, National Ignition Facility, and Z pulsed power facility. A source of monoenergetic ( δ ε / ε < 5 % ) 10- to 50-keV x rays can be produced by scattering of a short-pulse optical laser by a 23- to 53-MeV electron beam and collimating the scattered photons. The number and spectrum of scattered photons are calculated as a function of electron packet charge, electron and laser pulse duration, laser intensity, and collision geometry. A source delivering greater than 10 10 photons in a 1-mm-radius spot and 100-ps time resolution is plausible with the available electron gun and laser technology. Applications of this source for x-ray diffraction, x-ray imaging, x-ray absorption fine structure, and x-ray absorption spectroscopy in high-energy-density physics experiments are described, demonstrating significant advancements compared to the present state of the art. Published by the American Physical Society 2024

47 OTHER INSTRUMENTATION↗

Development and validation of fully open-source R2S shutdown dose rate capabilities in OpenMC *

We present the first fully open-source capabilities for shutdown dose rate (SDR) calculations of fusion energy facilities based on the Rigorous 2-Step (R2S) methodology. These capabilities have been implemented in the OpenMC Monte Carlo particle transport code, building on its existing capabilities while also leveraging new features that have been added to the code to support SDR calculations, such as decay photon source generation. Each of the individual physics components in the R2S workflow—neutron transport, activation, decay photon source generation, and photon transport—have been verified through code-to-code comparisons with MCNP6.2 and FISPACT-II 4.0. These comparisons generally demonstrate excellent agreement between codes for each of the physics components. The full cell-based R2S workflow was validated by performing a simulation of the first experimental campaign from the Frascati Neutron Generator (FNG) ITER dose rate benchmark problem from the Shielding INtegral Benchmark Archive and Database (SINBAD). For short cooling times, the dose calculated by OpenMC agrees with the experimental measurements within the stated experimental uncertainties. For longer cooling times, an overprediction of the shutdown dose was observed relative to experiment, which is consistent with previous studies in the literature. Altogether, these features constitute a combination of capabilities in a single, open-source codebase to provide the fusion community with a readily-accessible option for SDR calculations and a platform for rapidly analyzing the performance of fusion technology.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dark counts in optical superconducting transition-edge sensors for rare-event searches

Superconducting transition-edge sensors (TESs) are a type of quantum sensor known for their high single-photon detection efficiency and low background. This makes TESs ideal for particle-physics experiments searching for rare events. In this work, we present a comprehensive characterization of the background in optical TESs, distinguishing three types of events: electrical-noise, high-energy, and photonlike events. We introduce computational methods to automate the classification of events. We experimentally verify and simulate the source of the high-energy events. We also isolate the photonlike events, the expected signal in dielectric haloscopes searching for dark-matter dark photons, and achieve a photonlike dark-count rate of 3.6× 10 − 4 in the 0.8–3.2 eV energy range.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ptychographic wavefront characterization for single-particle imaging at x-ray lasers

A well-characterized wavefront is important for many x-ray free-electron laser (XFEL) experiments, especially for single-particle imaging (SPI), where individual biomolecules randomly sample a nanometer region of highly focused femtosecond pulses. We demonstrate high-resolution multiple-plane wavefront imaging of an ensemble of XFEL pulses, focused by Kirkpatrick–Baez mirrors, based on mixed-state ptychography, an approach letting us infer and reduce experimental sources of instability. From the recovered wavefront profiles, we show that while local photon fluence correction is crucial and possible for SPI, a small diversity of phase tilts likely has no impact. Our detailed characterization will aid interpretation of data from past and future SPI experiments and provides a basis for further improvements to experimental design and reconstruction algorithms.

47 OTHER INSTRUMENTATION↗

Dispersive X-ray absorption spectroscopy using independent grazing-incidence focusing and convexly bent Bragg-crystal dispersing optics

We present a modular instrument for dispersive X-ray absorption spectroscopy (DXAS) developed for the Advanced Spectroscopy Beamline at Sector 25 of the Advanced Photon Source. The setup employs a double-multilayer monochromator to provide X-rays with a broad energy bandwidth, Kirkpatrick–Baez mirrors for focusing, a convexly bent Bragg-crystal polychromator for energy dispersion, and a pixel-array detector to resolve all X-ray energies and collect their intensity simultaneously, thereby enabling acquisition of a full X-ray absorption spectrum in a single shot. The use of separate optics for X-ray focusing and energy dispersion provides high spatial resolution and avoids chromatic aberrations inherent in focusing bent-crystal optics, and a modular design makes implementation of the technique at other beamlines possible without requiring modifications to the upstream beamline configurations. Theoretical calculations are performed to determine optimal instrument operating parameters and demonstrate that an energy resolution better than the K-edge core-hole lifetime broadening can be maintained while providing a sufficient bandwidth for X-ray absorption near-edge structure spectroscopy through the full operating range of 5–11 keV. Additionally, instrument design, data analysis methods, and initial DXAS results on lithium–manganese–nickel oxide laminates are presented.

47 OTHER INSTRUMENTATION↗

The High Resolution Imaging Instrument for HEAO-B

The High Resolution Imaging Instrument for the HEAO-B X-ray Telescope satellite is designed to reproduce images of celestial X-ray sources in the range of 0.2 to 4.0 keV. It provides both imaging and temporal data. The basic detector is a two-stage microchannel plate with a crossed-grid charge detector. Preamplifiers, detector bias supplies, and some processing circuits are colocated with the detector. The remaining electronic circuits are located in a remote central electronic assembly. The processing system is designed for single-photon processing. The imaging data rate is limited to 100 data points per second. Non-imaging total-field count rate is acquired with a maximum dead time of 14 microseconds per event.

Kubierschky, K.↗

SULI Research Report

Acoustic levitation allows for the containerless manipulation of small samples limited by density, size, and shape. Modern acoustic levitators are either constructed with Langevin horns, which need to be machined to high tolerance and require at least 100V, or ultrasonic transducers, which are robust to changes in temperature and require low voltage. We investigated the ability of the TinyLev, a commercially available single axis levitator, and prototyped a two-axis levitator. Both the TinyLev and our two-axis levitator employ phased arrays of transducers and operate at 40 kHz. Models produced with the Python toolbox Levitate showed the characteristic nodes of the TinyLev and found two previously unpublished “traps” (stable local pressure minima) of the twoaxis levitator. We plan to use these levitators at the Advanced Photon Source (APS) to study a variety of samples, via white beam diffraction and high speed imaging. It is our goal to calculate the radial distribution function with respect to temperature across phase transitions.

42 ENGINEERING↗

Observations of the hard X-ray spectrum of the impulsive phase of solar flares

The impulsive solar hard X-ray spectrum provides a direct diagnostic on the impulsive energy release of the flare. The data from the hard X-ray (14-342 keV) spectrometer on OSO 7 have been examined for events covering a wide energy range to determine the photon spectrum more precisely. This resulted in a sample of 38 events. The data have been fitted with either single- or double-power laws, and with an exponential spectrum, as from thermal bremsstrahlung. The chi-squared statistic between two-parameter fits strongly favors the exponential fit, particularly at peak intensity when the widest energy range is sampled. This result supports a single-temperature thermal source of the impulsive solar hard X-rays with temperatures in the range 4.7-31 keV and emission measures in the range from 8.4 x 10 to the 43rd to 6.0 x 10 to the 46th per cu cm. The temperature reaches a single maximum and then rapidly decays, but the emission measure usually increases throughout, even after temperature maximum, for data with 10-s resolution.

Elcan, M. J.↗

Fermi/GBM Observations of SGRJ0501 + 4516 Bursts

We present our temporal and spectral analyses of 29 bursts from SGRJ0501+4516, detected with the Gamma-ray Burst Monitor onboard the Fermi Gamma-ray Space Telescope during the 13 days of the source activation in 2008 (August 22 to September 3). We find that the T(sub 90) durations of the bursts can be fit with a log-normal distribution with a mean value of approx. 123 ms. We also estimate for the first time event durations of Soft Gamma Repeater (SGR) bursts in photon space (i.e., using their deconvolved spectra) and find that these are very similar to the T(sub 90)s estimated in count space (following a log-normal distribution with a mean value of approx. 124 ms). We fit the time-integrated spectra for each burst and the time-resolved spectra of the five brightest bursts with several models. We find that a single power law with an exponential cutoff model fits all 29 bursts well, while 18 of the events can also be fit with two black body functions. We expand on the physical interpretation of these two models and we compare their parameters and discuss their evolution. We show that the time-integrated and time-resolved spectra reveal that E(sub peak) decreases with energy flux (and fluence) to a minimum of approx. 30 keV at F = 8.7 x 10(exp -6)erg/sq cm/s, increasing steadily afterwards. Two more sources exhibit a similar trend: SGRs J1550 - 5418 and 1806 - 20. The isotropic luminosity, L(sub iso), corresponding to these flux values is roughly similar for all sources (0.4 - l.5 x 10(exp 40) erg/s.

Lin, Lin↗

GeoSoilEnviroCARS (Sector 13) at the Advanced Photon Source: a comprehensive synchrotron radiation facility for Earth science research at ambient and extreme conditions

GeoSoilEnviroCARS (GSECARS) is a comprehensive analytical laboratory for Earth and environmental science research using X-ray beams from the Advanced Photon Source, Argonne National Laboratory. State-of-the-art instruments are available for (1) high-pressure/high- or low-temperature diffraction, total scattering, and spectroscopy (Brillouin, Raman, and VIS-IR) using the laser heated diamond anvil cell (DAC); (2) high-pressure/high-temperature diffraction, scattering, and imaging as well as acoustic emission (AE) and ultrasonics using the large-volume press (LVP); (3) powder, single crystal, and surface/interface diffraction; (4) X-ray absorption fine structure spectroscopy; (5) X-ray fluorescence microprobe analysis; and (6) microtomography. As shown here, experiments are facilitated by senior level staff who collaborate on all aspects of the analytical work including experiment design, sample preparation, data collection, data interpretation, and publication preparation. Both technical and scientific synergies occur as a result of the intimate association of the various techniques and scientists experienced in the applications of synchrotron radiation to Earth, environmental, and planetary science problems. The facility includes state-of-the-art instrumentation designed and built in-house, including custom X-ray optics, online and offline laser-based systems, specialized sample environments and positioning systems, as well as pixel-array and multi-crystal energy dispersive X-ray detectors, which are available to be shared among the experimental stations.

36 MATERIALS SCIENCE↗

Characterization of a Pixelated Cadmium Telluride Detector System Using a Polychromatic X-Ray Source and Gold Nanoparticle-Loaded Phantoms for Benchtop X-Ray Fluorescence Imaging

In this paper, the imaging dose and scan time have been considered as the two major constraints for routine benchtop x-ray fluorescence computed tomography (XFCT) imaging. One way to address this issue is to acquire x-ray fluorescence (XRF) signals in parallel through a 2D array of single-crystal detectors or a pixelated detector along with the cone-beam x-ray source. To identify a detector system suitable for this purpose, a commercially available, fully spectroscopic cadmium telluride (CdTe) pixelated detector, HEXITEC (High-Energy X-ray Imaging Technology), was tested under the experimental conditions optimized for benchtop XFCT imaging of gold nanoparticles (GNPs). Specifically, two different parallel-hole stainless steel collimators were fabricated and coupled with the detector for seamless integration into our existing benchtop cone-beam XFCT system. After the detector deployment, this benchtop XFCT system was used to detect XRF photons from GNP-loaded phantoms. A pixel-merging algorithm was introduced to enhance the sensitivity of XRF photon detection thereby minimizing the scan time. The effect of pixel-level charge sharing correction algorithms was investigated within the context of benchtop XFCT imaging. The detector energy resolution, in terms of the full width at half maximum (FWHM) values at different gold K-shell XRF energies, was also determined. Of the two charge sharing correction algorithms examined, the charge sharing addition gave better sensitivity than the charge sharing discrimination (csd). On the other hand, under the current experimental conditions, the energy resolution of the HEXITEC detector was the best with the csd and estimated to be 1.56 keV FWHM at 66-69 keV photon energy. Overall, despite some degradation of the detector energy resolution (compared with typical single crystal CdTe detectors), the HEXITEC detector enabled parallel data acquisition under the experimental conditions typical of benchtop XFCT imaging and operated well within our benchtop XFCT setup.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The working principle of hybrid perovskite gamma-ray photon counter

Gamma-ray spectroscopy that quantifies the gamma-ray energies is a critical technology widely needed in astrophysics, nuclear material detection and medical treatment. The key is to precisely count gamma-ray photons using sensitive detectors. In this paper, we investigate the operational principles of chlorine-doped methylammonium lead tribromide (MAPbBr 3-x Cl x ) perovskite single crystal detectors that can efficiently count gamma-ray photon events with electrical pulses. Specifically, we find the main dark current originates from the thermally activated electron injection from the impurities, and using high work function contacts can block out the dark noise thus allows for efficient pulse collection at higher electrical fields ~500 V/cm. As a result, we observe strong electrical pulses when exposing the detector under radioactive sources emitting gamma-ray photons at various energies. Our results also reveal the fundamental issues that prevent the reliable observation of photo-electric peak. This work suggest pathway towards energy resolved gamma-ray spectroscopy using perovskite crystal detectors.

36 MATERIALS SCIENCE↗