At least 289 records · Page 16

The Third Flight of the Marshall Grazing Incidence X-Ray Spectrometer (MaGIXS-3)

The Marshall Grazing Incidence X-ray Spectrometer (MaGIXS) is the first X-ray slitless imaging spectrograph sounding rocket instrument designed to observe spectrally dispersed soft X-ray images of the solar corona over a wide field-of-view. During the first flight of MaGIXS (MaGIXS-1), occurred on 30 July 2021, several emission lines from coronal structures including X-ray bright points were observed. Further, MaGIXS-1 analysis also demonstrated the successful inversion of overlappograms using robust unfolding algorithms. Given the demonstrated success of MaGIXS-1, the second flight of the instrument with a simplified optical design, MaGIXS-2, is scheduled for 2024 to observe high temperature diagnostic emission lines. Results from MaGIXS-1 discovered dominant missing emission lines near 15A, arising from relatively cool plasma that peaks around 2 MK. This wavelength region hosts several closely spaced satellite lines of Fe XVII, Fe XVI and Fe XV ions, which are expected to be enhanced at lower temperatures and are currently unmodeled in the CHIANTI atomic database. This wavelength region offers one of the most unique diagnostics to measure electron temperature, as well as signatures of equilibrium state of the plasma in active regions, which has not been studied so far. The goal of MaGIXS-3 mission is the to determine coronal heating parameters, such as the spatial and temporal properties of coronal heating events, by measuring discriminating observations, such as electron temperature, effective temperature, density, abundance, and departures from thermal equilibrium of the plasma, by observing the Sun in the SXR wavelength range. To meet this goal, the MaGIXS instrument will be upgraded with a new X-ray telescope mirror that will provide higher spatial and spectral resolution and throughput, allowing for spectral lines to be observed at the relevant spatial and temporal scales. In addition, MaGIXS-3 will also carry The Resolving Inversion Context X-ray Spectrometer (TRICXS), a high dispersion Bragg crystal spectrometer to spectrally resolve the lines near 14.9 to 15.9A, critical to unlock the full diagnostic potential of this wavelength range. Here we will present the preliminary concept design of MaGIXS-3 and discuss the potential observations.

X-ray Imaging↗

The Next Generation Marshall Grazing Incidence X-Ray Spectrometer (MaGIXS) Sounding Rocket Experiments

The Marshall Grazing Incidence X-ray Spectrometer (MaGIXS) is a sounding rocket experiment that carries an X-ray slitless imaging spectrograph to observe spectrally dispersed soft X-ray (SXR) images of the solar corona over a wide field-of-view. The first flight of MaGIXS occurred on 30 July 2021, during which several emission lines from coronal structures including X-ray bright points were observed. Analysis of MaGIXS-1 data demonstrated the application of new inversion techniques and opened a new arena of inverting complex spectroheliogram data, which has spatial-spectral information overlapped. The second flight of MaGIXS, with a simplified optical design, is scheduled for 2024. The goal of MaGIXS-2 is to observe high temperature diagnostic emission lines within an active region core. MaGIXS-1 discovered dominant missing emission lines near 15Å wavelength region, which hosts several closely spaced satellite lines of Fe XVII, Fe XVI, and Fe XV ions, arising from relatively cool plasma that peaks near 2MK. These lines are expected to be enhanced at lower temperatures and offers one of the most unique diagnostics to measure electron temperature, as well as signatures of equilibrium state of the plasma in active regions, which has not been studied so far. The science goal of the third sounding rocket flight of MaGIXS is to determine coronal heating parameters, such as the spatial and temporal properties of coronal heating events, by measuring discriminating observations, such as electron temperature, effective temperature, density, abundance, and departures from thermal equilibrium of the plasma, by observing the Sun in the SXR wavelength range. For this, the MaGIXS instrument will be upgraded with a new X-ray telescope mirror that will provide higher spatial and spectral resolution and throughput, allowing for spectral lines to be observed at the relevant spatial and temporal scales. In addition, MaGIXS-3 will also carry The Resolving Inversion Context X-ray Spectrometer (TRICXS), a high dispersion Bragg crystal spectrometer to spectrally resolve the lines near 15Å, critical to unlock the full diagnostic potential of this wavelength range. Here we will present the preliminary concept design of MaGIXS-3 and discuss the potential observations.

X-ray Imaging↗

The Peregrine Ion Trap Mass Spectrometer (PITMS) Investigation Development and Pre-Flight Planning

The Peregrine Ion Trap Mass Spectrometer (PITMS) is a mass spectrometer instrument that operated during the Astrobotic Peregrine Mission-1 as part of the NASA Commercial Lunar Payload Services (CLPS) initiative. This paper describes the instrument and investigation design, development, and planning conducted by the PITMS team consisting of a successful partnership between NASA Goddard Space Flight Center (GSFC), The Open University (OU), NASA, and ESA. PITMS was designed to measure the abundance and temporal variability of volatile species in the near-surface lunar exosphere from a landed platform on the lunar surface. The PITMS instrument consisted of an ESA-provided Exospheric Mass Spectrometer (EMS; including sensor, electronics, controller, power supply boards) and a GSFC wrapper that provided structural elements, thermal control, and a deployable dust cover. PITMS was designed to operate as a passive sampler, where ambient gases would enter PITMS through an aperture, diffuse around the mass analyzer cavity, become ionized by electron impact and trapped in a radiofrequency field, then sequentially released to a detector to build a mass spectrum. PITMS was capable of measuring species with a massto-charge ratio (m/z) from 10 to 150 Da, with a mass resolution of approximately 0.5 amu. The PITMS science investigation was planned to be operated by GSFC with an international team of scientists. Though the mission did not achieve its lunar landing, information about the PITMS instrument and planning is provided to be able to understand and effectively use data that will be forthcoming from the investigation.

Barbara Cohen↗

Nadir Measurements of Carbon Monoxide Distributions by the Tropospheric Emission Spectrometer Instrument Onboard the Aura Spacecraft: Overview of Analysis Approach and Examples of Initial Results

We provide an overview of the nadir measurements of carbon monoxide (CO) obtained thus far by the Tropospheric Emission Spectrometer (TES). The instrument is a high resolution array Fourier transform spectrometer designed to measure infrared spectral radiances from low Earth orbit. It is one of four instruments successfully launched onboard the Aura platform into a sun synchronous orbit at an altitude of 705 km on July 15, 2004 from Vandenberg Air Force Base, California. Nadir spectra are recorded at 0.06/cm spectral resolution with a nadir footprint of 5 x 8 km. We describe the TES retrieval approach for the analysis of the nadir measurements, report averaging kernels for typical tropical and polar ocean locations, characterize random and systematic errors for those locations, and describe instrument performance changes in the CO spectral region as a function of time. Sample maps of retrieved CO for the middle and upper troposphere from global surveys during December 2005 and April 2006 highlight the potential of the results for measurement and tracking of global pollution and determining air quality from space.

carbon monoxide↗

Science Measurement Requirements for Imaging Spectrometers from Airborne to Spaceborne

This slide presentation reviews the objectives of the work to create imaging spectrometers. The science objectives are to remotely determine the properties of the surface and atmosphere (physics, chemistry and biology) revealed by the interaction of electromagnetic energy with matter via spectroscopy. It presents a review the understanding of spectral, radiometric and spatial science measurement requirements for imaging spectrometers based upon science research results from past and current airborne and spaceborne instruments. It also examines the future requirements that will enable the next level of imaging spectroscopy science.

radiometric requirements↗

Airborne Carbon Dioxide Laser Absorption Spectrometer for IPDA Measurements of Tropospheric CO2: Recent Results

The National Research Council's decadal survey on Earth Science and Applications from Space[1] recommended the Active Sensing of CO2 Emissions over Nights, Days, and Seasons (ASCENDS) mission for launch in 2013-2016 as a logical follow-on to the Orbiting Carbon Observatory (OCO) which is scheduled for launch in late 2008 [2]. The use of a laser absorption measurement technique provides the required ability to make day and night measurements of CO2 over all latitudes and seasons. As a demonstrator for an approach to meeting the instrument needs for the ASCENDS mission we have developed the airborne Carbon Dioxide Laser Absorption Spectrometer (CO2LAS) which uses the Integrated Path Differential Absorption (IPDA) Spectrometer [3] technique operating in the 2 micron wavelength region.. During 2006 a short engineering checkout flight of the CO2LAS was conducted and the results presented previously [4]. Several short flight campaigns were conducted during 2007 and we report results from these campaigns.

lidar↗

The Geostationary Fourier Transform Spectrometer

The Geostationary Fourier Transform Spectrometer (GeoFTS) is an imaging spectrometer designed for a geostationary orbit (GEO) earth science mission to measure key atmospheric trace gases and process tracers related to climate change and human activity. GEO allows GeoFTS to continuously stare at a region of the earth for frequent sampling to capture the variability of biogenic fluxes and anthropogenic emissions from city to continental spatial scales and temporal scales from diurnal, synoptic, seasonal to interannual. The measurement strategy provides a process based understanding of the carbon cycle from contiguous maps of carbon dioxide (CO2), methane (CH4), carbon monoxide (CO), and chlorophyll fluorescence (CF) collected many times per day at high spatial resolution (~2.7kmx2.7km at nadir). The CO2/CH4/CO/CF measurement suite in the near infrared spectral region provides the information needed to disentangle natural and anthropogenic contributions to atmospheric carbon concentrations and to minimize uncertainties in the flow of carbon between the atmosphere and surface. The half meter cube size GeoFTS instrument is based on a Michelson interferometer design that uses all high TRL components in a modular configuration to reduce complexity and cost. It is self-contained and as independent of the spacecraft as possible with simple spacecraft interfaces, making it ideal to be a "hosted" payload on a commercial communications satellite mission. The hosted payload approach for measuring the major carbon-containing gases in the atmosphere from the geostationary vantage point will affordably advance the scientific understating of carbon cycle processes and climate change.

atmospheric trace gases↗

High Precision, Absolute Total Column Ozone Measurements from the Pandora Spectrometer System: Comparisons with Data from a Brewer Double Monochromator and Aura OMI

We present new, high precision, high temporal resolution measurements of total column ozone (TCO) amounts derived from ground-based direct-sun irradiance measurements using our recently deployed Pandora single-grating spectrometers. Pandora's small size and portability allow deployment at multiple sites within an urban air-shed and development of a ground-based monitoring network for studying small-scale atmospheric dynamics, spatial heterogeneities in trace gas distribution, local pollution conditions, photochemical processes and interdependencies of ozone and its major precursors. Results are shown for four mid- to high-latitude sites where different Pandora instruments were used. Comparisons with a well calibrated double-grating Brewer spectrometer over a period of more than a year in Greenbelt MD showed excellent agreement and a small bias of approximately 2 DU (or, 0.6%). This was constant with slant column ozone amount over the full range of observed solar zenith angles (15-80), indicating adequate Pandora stray light correction. A small (1-2%) seasonal difference was found, consistent with sensitivity studies showing that the Pandora spectral fitting TCO retrieval has a temperature dependence of 1% per 3K, with an underestimation in temperature (e.g., during summer) resulting in an underestimation of TCO. Pandora agreed well with Aura-OMI (Ozone Measuring Instrument) satellite data, with average residuals of <1% at the different sites when the OMI view was within 50 km from the Pandora location and OMI-measured cloud fraction was <0.2. The frequent and continuous measurements by Pandora revealed significant short-term (hourly) temporal changes in TCO, not possible to capture by sun-synchronous satellites, such as OMI, alone.

Ozone↗

Performance of the Linear Ion Trap Mass Spectrometer for the Mars Organic Molecule Analyzer (MOMA) Investigation on the 2018 Exomars Rover

The 2018 ExoMars rover mission includes the Mars Organic Molecule Analyzer (MOMA) investigation. MOMA will examine the chemical composition of samples acquired from depths of up to two meters below the martian surface, where organics may be protected from degradation derived from cosmic radiation and/or oxidative chemical reactions. When combined with the complement of instruments in the rover's Pasteur Payload, MOMA has the potential to reveal the presence of a wide range of organics preserved in a variety of mineralogical environments, and to begin to understand the structural character and potential origin of those compounds. The MOMA investigation is led by the Max Planck Institute for Solar System Research (MPS) with the mass spectrometer subsystem provided by NASA GSFC. MOMA's linear ion trap mass spectrometer (ITMS) is designed to analyze molecular composition of: (i) gas evolved from pyrolyzed powder samples and separated in a gas chromatograph; and, (ii) ions directly desorbed from crushed solid samples at Mars ambient pressure, as enabled by a pulsed UV laser system, fast-actuating aperture valve and capillary ion inlet. Breadboard ITMS and associated electronics have been advanced to high end-to-end fidelity in preparation for flight hardware delivery to Germany in 2015.

linear ion trap mass spectrometer↗

Ultra-Compact Imaging Spectrometer (UCIS) for In-Situ Planetary Mineralogy: Laboratory and Field Calibration

The Ultra-Compact Imaging Spectrometer (UCIS) is a miniature telescope and spectrometer system intended for mapping terrain mineralogy over distances from 1.5 m to infinity with spatial sampling of 1.35 mrad over a 33 deg field, and spectral sampling of 10 nm in the 600-2500 nm range. The core of the system has been designed for operation in a Martian environment, but can also be used in a terrestrial environment when placed inside a vacuum vessel. We report the laboratory and field calibration data that include spatial and spectral calibration, and demonstrate the use of the system.

Imaging spectroscopy↗

Portable 4.6 Micrometers Laser Absorption Spectrometer for Carbon Monoxide Monitoring and Fire Detection

The air quality aboard manned spacecraft must be continuously monitored to ensure crew safety and identify equipment malfunctions. In particular, accurate real-time monitoring of carbon monoxide (CO) levels helps to prevent chronic exposure and can also provide early detection of combustion-related hazards. For long-duration missions, environmental monitoring grows in importance, but the mass and volume of monitoring instruments must be minimized. Furthermore, environmental analysis beyond low-Earth orbit must be performed in-situ, as sample return becomes impractical. Due to their small size, low power draw, and performance reliability, semiconductor-laser-based absorption spectrometers are viable candidates for this purpose. To reduce instrument form factor and complexity, the emission wavelength of the laser source should coincide with strong fundamental absorption lines of the target gases, which occur in the 3 to 5 micrometers wavelength range for most combustion products of interest, thereby reducing the absorption path length required for low-level concentration measurements. To address the needs of current and future NASA missions, we have developed a prototype absorption spectrometer using a semiconductor quantum cascade laser source operating near 4.6 micrometers that can be used to detect low concentrations of CO with a compact single-pass absorption cell. In this study, we present the design of the prototype instrument and report on measurements of CO emissions from the combustion of a variety of aerospace plastics.

Tunable Environmental Laser Spectrometer (TELS)↗

Micro-Spec: An Ultracompact, High-sensitivity Spectrometer for Far-Infrared and Submillimeter Astronomy

High-performance, integrated spectrometers operating in the far-infrared and submillimeter ranges promise to be powerful tools for the exploration of the epochs of reionization and initial galaxy formation. These devices, using high-efficiency superconducting transmission lines, can achieve the performance of a meter-scale grating spectrometer in an instrument implemented on a 4 inch silicon wafer. Such a device, when combined with a cryogenic telescope in space, provides an enabling capability for studies of the early universe. Here, the optical design process for Micro-Spec (micron-Spec) is presented, with particular attention given to its two-dimensional diffractive region, where the light of different wavelengths is focused on the different detectors. The method is based on the stigmatization and minimization of the light path function in this bounded region, which results in an optimized geometrical configuration. A point design with an efficiency of (is) approximately 90% has been developed for initial demonstration and can serve as the basis for future instruments. Design variations on this implementation are also discussed, which can lead to lower efficiencies due to diffractive losses in the multimode region.

cryogenic telescope↗

Design and Performance of A High Resolution Micro-Spec: An Integrated Sub-Millimeter Spectrometer

Micro-Spec is a compact sub-millimeter (approximately 100 GHz--1:1 THz) spectrometer which uses low loss superconducting microstrip transmission lines and a single-crystal silicon dielectric to integrate all of the components of a diffraction grating spectrometer onto a single chip. We have already successfully evaluated the performance of a prototype Micro-Spec, with spectral resolving power, R=64. Here we present our progress towards developing a higher resolution Micro-Spec, which would enable the first science returns in a balloon flight version of this instrument. We describe modifications to the design in scaling from a R=64 to a R=256 instrument, as well as the ultimate performance limits and design concerns when scaling this instrument to higher resolutions.

spectrometer↗

Wide-Field InfraRed Survey Telescope (WFIRST) Slitless Spectrometer: Design, Prototype, and Results

The slitless spectrometer plays an important role in the Wide-Field InfraRed Survey Telescope (WFIRST) mission for the survey of emission-line galaxies. This will be an unprecedented very wide field, HST quality 3D survey of emission line galaxies. The concept of the compound grism as a slitless spectrometer has been presented previously. The presentation briefly discusses the challenges and solutions of the optical design, and recent specification updates, as well as a brief comparison between the prototype and the latest design. However, the emphasis of this paper is the progress of the grism prototype: the fabrication and test of the complicated diffractive optical elements and powered prism, as well as grism assembly alignment and testing. Especially how to use different tools and methods, such as IR phase shift and wavelength shift interferometry, to complete the element and assembly tests. The paper also presents very encouraging results from recent element tests to assembly tests. Finally we briefly touch the path forward plan to test the spectral characteristic, such as spectral resolution and response.

Grism↗

Temporal Gain Correction for X-Ray Calorimeter Spectrometers

Calorimetric X-ray detectors are very sensitive to their environment. The boundary conditions can have a profound effect on the gain including heat sink temperature, the local radiation temperature, bias, and the temperature of the readout electronics. Any variation in the boundary conditions can cause temporal variations in the gain of the detector and compromise both the energy scale and the resolving power of the spectrometer. Most production X-ray calorimeter spectrometers, both on the ground and in space, have some means of tracking the gain as a function of time, often using a calibration spectral line. For small gain changes, a linear stretch correction is often sufficient. However, the detectors are intrinsically non-linear and often the event analysis, i.e., shaping, optimal filters etc., add additional non-linearity. Thus for large gain variations or when the best possible precision is required, a linear stretch correction is not sufficient. Here, we discuss a new correction technique based on non-linear interpolation of the energy-scale functions. Using Astro-HSXS calibration data, we demonstrate that the correction can recover the X-ray energy to better than 1 part in 104 over the entire spectral band to above 12 keV even for large-scale gain variations. This method will be used to correct any temporal drift of the on-orbit per-pixel gain using on-board calibration sources for the SXS instrument on the Astro-H observatory.

X-ray detector X-ray spectrometer X-ray calorimete↗