Search NASA⌕ Search

SEARCH · Search NASA

Results for “Spectrometers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Cloud Condensation Nuclei and Printed Optical Particle Spectrometer Measurements at Mt. Soledad during EPCAPE 2023-24

These measurements are provided by a differential mobility analyzer operated as a scanning mobility particle sizer, a printed particle optical spectrometer (POPS), and a continuous flow diffusion cloud condensation nuclei (CCN) counter. The instruments sample from either a counterflow virtual impactor inlet or an isokinetic inlet. The measurements provide the mobility aerosol size distribution (30-360 nm), optical size distribution (150 - 6000 nm), size-resolved CCN distribution (30-360 nm) at 0.2, 0.4, 0.6, 0.8, and 1.0% supersaturation. CCN measurements are performed in denuded and undenuded configuration, where denuded refers to the removal of low molecular weight organic vapors. A detailed NetCDF header is included with the datafiles. Users of these measurements are encouraged to consult with the authors about appropriate interpretation before submitting for publication, offering coauthorship where appropriate.

54 ENVIRONMENTAL SCIENCES↗

SCILLA mini-Aerosol Mass Spectrometer (mAMS) airborne data

Measurements of non-refractory, sub-micron aerosol composition, namely organic, sulfate, nitrate, chloride, and ammonium aerosols, by a mini- aerosol mass spectrometer (mAMS, Aerodyne Research, Inc.) are reported. The instrument sampled ambient air through 3 different inlets: unperturbed ambient air, a Counter-flow Virtual Impactor (CVI), and an oxidation flow reactor (OFR). Users should consult the Sampling Key for proper interpretation of the data.

and secondary aerosol in air",total_organics,nitra↗

A High-Magnetic-Field Polarized 3He Target for Jefferson Lab’s CLAS12 Spectrometer

We are developing a polarized 3He target concept for use in high luminosity electron scattering experiments in the high magnetic field environment of Jefferson Lab's CLAS12 spectrometer. By combining recent advancements in metastability exchange optical pumping of 3He with cryogenic, double-cell target methods such as those used for the MIT-Bates 88-02 experiment, a target with polarization and gas density comparable to traditional, low-field polarized 3He targets can be reached within high magnetic fields. We have established a new 3He pumping system at JLab, and are preparing for our first tests exploring polarization performance versus magnetic field and gas pressure in a single cell before we move to the construction of a full, cryogenic, double-cell prototype target.

Maxwell, James↗

A Forward Multiparticle Spectrometer for the LHC: Hadron spectra and Long-lived particle search

I describe a possible Forward Multiparticle Spectrometer (FMS) that could be installed downstream of the superconducting recombination dipole D1 in Run 4, from z = 96 m - 126 m to measure multi-TeV hadron spectra in low luminosity p + p collisions at Rt(s) = 14 TeV, as well as p + O and O + O collisions as relevant for cosmic ray showers. Light antinuclei and charmed hadrons at high Feynman xF can be measured, both of importance for astrophysics. At the full high luminosity HL-LHC a search for new long-lived neutral particles (LLPs) decaying in a 20 m long, 70 cm diameter vacuum pipe to visible decay modes (including gamma+gamma, e+e-, mu+mu-, tau+tau-, ccbar and jets) can be made. The FMS is especially well suited for LLPs with 1 GeV < M(X)< 10 GeV and lifetimes c.tau from about 10 m to several km. I discuss this as a possible addition to CMS but it has no formal approval yet, therefore the talk is not given on behalf of CMS.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-ray spectrometer

An x-ray spectrometer includes: an x-ray plasma source that produces first x-rays; an x-ray optic in optical communication with the x-ray plasma source and that: receives the first x-rays from the x-ray plasma source; focuses the first x-rays to produce second x-rays; and communicates the second x-rays to a sample that produces product x-rays in response to receipt of the second x-rays and second light; and a microcalorimeter array detector in optical communication with the sample and that receives the product x-rays from the sample.

Ullom, Joel↗

A measurement of proton-carbon forward scattering in a proof-of-principle test of the EMPHATIC spectrometer

The next generation of long-baseline neutrino experiments will be capable of precision measurements of neutrino oscillation parameters, precision neutrino-nucleus scattering, and unprecedented sensitivity to physics beyond the Standard Model. Reduced uncertainties in neutrino fluxes are necessary to achieve high precision and sensitivity in these future precise neutrino measurements. New measurements of hadron-nucleus interaction cross sections are needed to reduce uncertainties of neutrino fluxes. We report measurements of the differential cross-section as a function of scattering angle for proton-carbon interactions with a single charged particle in the final state at beam momenta of 20, 30, and 120 GeV/c. These measurements are the result of a beam test for EMPHATIC, a hadron-scattering and hadron-production experiment. The total, elastic and inelastic cross-sections are also extracted from the data and compared to previous measurements. These results can be used in current and future long-baseline neutrino experiments, and demonstrate the feasibility of future measurements by an upgraded EMPHATIC spectrometer.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Higher order and penumbral blurring correction methodology for Opacity spectrometer used on the NIF

63rd Annual Meeting of the APS Division of Plasma Physics November 8-12, 2021 • Pittsburgh, Pennsylvania Virtual presentation must be uploaded by Nov 3rd 2pm PST Session Date / Time: 11/11/2021, 2:00 pm - 5:00 pm Title: HED: Laboratory Astrophysics Type: Oral Contributed Presentation: Higher order and penumbral blurring correction methodology for Opacity spectrometer used on the NIF.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutral Pion Electroproduction and development of a Neutral Particle Spectrometer

Protons and neutrons, i.e. nucleons, are the basic building blocks of the matter in the visible universe. The strong force binds the nucleons to form nuclei. The electromagnetic force forms the atoms by binding the electrons with the nuclei. The electromagnetic interaction is well understood by Quantum Electrodynamics (QED), which shows the most precise predictability amongst all the theories in physics. In QED, charges interact with each other by exchanging photons. The Quantum Chromodynamics (QCD) describes the strong interaction. Its degrees of freedom are quarks and gluons, the fundamental constituents of the nucleons. The quarks interact with each other by exchanging gluons. However, unlike QED, the gluons interact amongst themselves. This feature of self bindings of the gluons confines the quarks and gluons in the nucleons/hadrons, never to be seen as free. In order to study some of the features of QCD, such as confinement or the structure of the nucleon, one usually needs to rely on experiments. Electromagnetic probes, governed by the well-understood QED, are excellent tools to probe the nucleon. In general, different scales, e.g. electron beam energies, probe different regions of the nucleon. At low energy, of the order of a few GeV, the electron probes the nucleon in the valence quark region. As its energy increases, the electron probes the sea quark and gluon regions. The study of the nucleon structure in all these regions is needed to fully understand QCD. Form factors and parton distribution functions measured from elastic scattering and deep inelastic scattering of leptons off nucleons have provided a partial view of the internal structure of the nucleon. In the mid-1990s, Generalized Parton Distributions (GPDs) were developed. These new objects are a generalization of the form factors and parton distribution functions, but contain richer information on the nucleon internal structure. GPDs are accessible experimentally by deep exclusive reactions. Deeply virtual Compton scattering (DVCS) and deeply virtual meson production (DVMP) are some examples. The first dedicated DVCS/DVMP experiment took place in 2004 in Hall A at The Thomas Jefferson National Accelerator Facility, i.e. Jefferson Lab, in Virginia, U.S.A. A new DVCS/DVMP experiment, after the beam energy upgrade of Jefferson Lab, was carried out in Hall A in a wider kinematic range. Its data were taken from 2014 to 2016. In Hall C at Jefferson Lab, the next DVCS/DVMP experiment will take place. The Hall C experiment will further exploit the kinematic range with higher precision. A Neutral Particle Spectrometer (NPS) is in development to measure DVCS/DVMP events under high background conditions. Jefferson Lab will provide the highest precision data in the valence quark region for various exclusive reactions. The Electron-Ion Collider (EIC) is a future experimental facility currently planned to start operations around 2030 in the U.S.A. Its high energy and high luminosity will probe the sea quark and gluon regions providing answers to the outstanding questions of QCD, in particular in the region where matter is dominated by gluons. First of all, this document describes the data analysis and results of the Hall A neutral pion electroproduction off the proton, from the data taken in 2014-2016. Later, some of the developments towards the construction of the electromagnetic calorimeter of the NPS for the upcoming DVCS/DVMP experiment in Hall C are presented. Finally, one of the candidate materials for the EIC calorimeter, a glass scintillator, will be briefly introduced. I have participated to all these projects, in collaboration with many colleagues. I present in this thesis my contributions to each of these projects. My contributions to the neutral pion data analysis were focused on background subtractions on the calorimeter, acceptance calculations, and the estimation of the systematic uncertainty associated to the event selection cuts. Some necessary information on calibrations of the detectors and data analysis methods are also described. In the NPS project, I performed background dose calculations and energy and position resolution studies of the calorimeter, all using Monte Carlo simulations, with realistic geometries of the experimental apparatus. Characterization of the crystals of the calorimeter was also done. Additionally, I measured the radiation hardness of some glass scintillator in its early stage of development. In order to have a future reference when the glass calorimeter prototype will be tested, I simulated the energy resolution of the prototype.

Ko, Ho-San↗

Fourier domain dynamic correction method for complex optical fringes in laser spectrometers

A method is provided for Fourier domain dynamic correction of optical fringes in a laser spectrometer. The method includes Fourier transforming a background spectrum contaminated with the optical fringes to obtain baseline fringes in a frequency domain. The method includes partitioning the baseline fringes in the frequency domain to obtain partitioned baseline fringes. The method includes reconstructing the partitioned baseline fringes as separate spectra. The method includes constructing a fitting model to approximate the background spectrum by assigning a first and a second free parameter to each of partitioned baseline fringe components to respectively allow for drift and amplitude adjustments during a fitting of the fitting model. The method includes applying the fitting model to a newly acquired spectrum to provide an interpretation of the newly acquired spectrum having a reduced influence of spectral contamination on concentration retrieval.

Teng, Cheyenne↗

Short pulsewidth high repetition rate nanosecond transient absorption spectrometer

A high-sensitivity nanosecond to millisecond transient absorption spectrometer for measurements of miniscule signals under low excitation intensities includes an excitation source generating a >100 Hz, <5 ns pulsewidth excitation pulse for exciting a light absorbing sample, a probe light source for generating a high photon flux probe light beam producing an average irradiance greater than 1 μW m-2 nm-1 for measuring the transient absorption spectrum of the sample before and after excitation by the excitation source, a DC-coupled detector capable of measuring light for enabling synchronous measurement of both the transmission of the probe light beam and the change in transmission of the probe light beam between a signal with the excitation pulse present and a signal in the absence of the excitation pulse, and a digital oscilloscope with a trigger rearm time capable of collecting every trigger event at frequencies including 1MHz, for enabling sequential noise subtraction protocols.

Rimshaw, Adam↗

Search For Excited Cascade Hypersons (¿*-) Using the CLAS12 Spectrometer at Jefferson Laboratory

The number of experimentally observed doubly strange Cascade states to date is far fewer than has been predicted theoretically. The CLAS12 Very Strange physics program (E12- 11-005A) at the Thomas Jefferson National Accelerator Facility aims to study the electroproduction of these states using the newly upgraded CEBAF Large Acceptance Spectrometer for 12 GeV (CLAS12) in experimental Hall B. In this project, the reaction ep ! e0K+K+??? ! e0K+K+K?(?=?0) is studied using CLAS12 Run Group A (RG-A) data sets taken by impinging electron beams of 10:2 and 10:6 GeV energies on an LH2 target. Scattered electrons are detected with either the Forward Detector (FD), covering a polar angle range of 5? to 35? to study electroproduction, or with the Forward Tagger (FT), covering a polar angle range of 2:5? to 4:5?, to study quasi-real photoproduction. The CLAS12 detector with nearly a 4? solid angle coverage is used to detect scattered electrons and charged kaons in the ?final state. ?=?0 hyperons are reconstructed using the missing mass technique to explore intermediate doubly-strange hyperons (???) that decay to K? and ?=?0. No statistically significant ??? states other than the ???(1530) were found in the missing mass spectra based on the currently available statistics in the CLAS12-FD acceptance only. A maximum log-likelihood method is implemented to determine the statistical significance and the upper limits on the ???(1820) electroproduction cross section by constructing 95% confidence level boundaries on the ???(1820) yields. Additional research was conducted to investigate the upper limit electroproduction cross section of the reaction ep ! e0K+K+??? ! e0K+K+K?(?=?0) as a function of the electroproduced ??? mass and the differential cross section ( d?dMM(e0K+K+) ) as a function of missing mass MM(e0K+K+) for electroproduction and quasi-real photoproduction processes.

Khanal, Achyut↗

Multichannel angular spectrometer

A multichannel angular spectrometer includes an array of fiber pickups having an arcuate arrangement and focused about a sample volume. A broadband light source is configured to illuminate a sample within the sample volume. At least one dispersion element is in optical communication with the array of fiber pickups. An imaging sensor is in optical communication with the array of fiber pickups. The imaging sensor is configured to image the broadband light received by the array of fiber pickups and dispersed by the at least one dispersion element. A processor is in electrical communication with the imaging sensor. The processor has a power supply and computer-readable memory.

47 OTHER INSTRUMENTATION↗

Systems and methods for in-situ calibration of scintillation spectrometer

A radiation spectrometer includes a scintillator, a photomultiplier, and one or more light-emitting diodes (LEDs). The scintillator receives radiation from the environment and emits light that is indicative of an energy of the radiation. The photomultiplier receives the light and outputs an electrical signal that is in turn indicative of the energy of the radiation. Spectral data can be generated based upon the electrical signal, wherein the spectral data indicates a number of radiation events in each of several energy bins. The one or more LEDs can emit LED light through the scintillator and toward the photomultiplier, wherein the LED light causes an LED peak in the spectral data that can be used to identify an absolute energy of radiation events in the spectral data.

Pfeifer, Kent B.↗

The General Antiparticle Spectrometer (GAPS) Antarctic Balloon Payload

The General Antiparticle Spectrometer (GAPS) is an Antarctic stratospheric balloon mission designed to provide unmatched sensitivity to low-energy (<0.25 GeV/n) cosmic-ray antiprotons, antideuterons, and antihelium nuclei as signatures of dark matter. The distinctive GAPS particle identification technique relies on measuring the energy loss along the track of an incoming antinucleus as it slows down and is captured into an exotic atom, and then detecting the de-excitation X-rays and the nuclear annihilation products. This measurement is realized using a Tracker composed of more than 1000 custom silicon strip detectors and a plastic scintillator time-of-flight (TOF) system instrumenting more than 40m$^2$. Together, these subsystems provide the velocity and energy resolution, stopping power, particle tracking, and X-ray identification necessary to distinguish rare antinucleus signals from the abundant positive-nucleus backgrounds, all within the constraints of a high-altitude mission. A multi-loop capillary heat pipe system has been developed to maintain the tracker operating temperature with significant mass and power savings over a conventional pump-based system. The first GAPS science payload flew for 25 days during the 2025/26 NASA Antarctic balloon campaign. We detail the design, integration, and commissioning of the payload prior to flight.

Aoyama, Kazutaka [JAXA, Sagamihara]↗

A 3D-Printed Millimeter-Wave Inline Waveguide-to-Coplanar-Waveguide Transition to Enable Dense Spectrometer Arrays for Intensity Mapping Surveys

We present a 3D-printed millimeter-wave, octave-bandwidth, in-line waveguide-to-coplanar-waveguide transition designed to enable focal planes with dense arrays of on-chip spectrometers. These arrays will enable compelling surveys of the large-scale structure of the universe through millimeter-wave intensity mapping. The transition consists of a four-step ridge-waveguide transformer that couples light from a rectangular waveguide onto a coplanar waveguide via an electrical connection made with indium bump bonds. We develop a tolerance-aware optimization approach to identify high-performance transition geometries that are robust to manufacturing variations; the same formulation can be applied to other tolerance-sensitive design problems. We also describe the implementation of a custom apparatus and procedure for bump-bonding a silicon chip to a metallized 3D-printed component. We detail the fabrication of the coplanar waveguide chip and three-dimensional waveguide structure, simulations and metrology of a test device, and room temperature reflectance measurements of this device. The room temperature metrology and reflection measurements are consistent with a model that predicts a coupling efficiency of $\mathord{\sim} 95\%$ at cryogenic temperatures in the 85-170 GHz frequency range.

Stover, Austin [Chicago U.; Chicago U., KICP] (ORC↗

EXCLUSIVE NEUTRAL PION ELECTROPRODUCTION CROSS SECTION MEASUREMENTSWITHANEUTRALPARTICLE SPECTROMETER

Deep Virtual Compton Scattering (DVCS), the exclusive electron-proton scattering process ep ¿e'p'¿, provides access to generalized parton distributions (GPDs), which correlate information about the longitudinal momentum and transverse spatial structure of quarks inside the nucleon. Experiment E12-13-010 in Hall C at Jefferson Lab was designed to take high-precision measurements of the DVCS cross section over an extended kinematic range using the newly commissioned Neutral Particle Spectrometer (NPS). The NPS features a high-resolution electromagnetic calorimeter and a streaming data acquisition system optimized for operation at high luminosities. This thesis presents the detector and analysis work carried out to support the NPS DVCS program. In particular, it focuses on the hardware design, calibration, and performance of the calorimeter. A development of a waveform reconstruction analysis of the calorimeter signals enabled improved extraction of pulse amplitudes and times. The waveform analysis was also extended to operate in a multithreaded environment, substantially reducing processing time for large datasets. Analysis of exclusive neutral pion electroproduction events in the calorimeter gives a strong validation of the calorimeter’s performance and resolution. Together these developments establish a foundation for future analyses and extraction of the DVCS cross section and its use in constraining the GPDs.

Kerver, Mitchell [Old Dominion Univ., Norfolk, VA ↗

An On-Chip Superconducting Kinetic Inductance Fourier Transform Spectrometer for Millimeter-Wave Astronomy

An on-chip FTS consists of two waveguides coupled to long superconducting transmission lines (STLs) (similar to 620 mm) using two coupling probes. The signal propagating on one of the STLs is phase-shifted with respect to the other line with a bias current that affects the nonlinear dependence of kinetic inductance, Lk(I)of the STL material. Here we describe the design and simulation of a superconducting on-chip FTS coupled to a dual polarization W-band (90-110 GHz) waveguide. These devices have applications in ground-based and space-based millimeter-wave spectral surveys.

Fourier transform spectrometer↗

Photodissociation dynamics of xylene isomers C 6 H 4 (CH 3 ) 2 at 157nm using an ultracompact velocity map imaging spectrometer – The C 7 H 7 channel

Here, we investigated the photodissociation dynamics of three xylene isomers C 6 H 4 (CH 3 ) 2 at 157nm. The center-of-mass translational energy distributions of C 7 H 7 radicals were found to peak at 26kJmol −1 . Although the ionization energy of the C 7 H 7 tolyl fragment exceeds the energy of a 157nm photon, C 7 H 7 + was observed as a result of the photoionization of vibrationally ‘hot’ tolyl (C 7 H 7 ) radicals and/or two-photon ionization. The formation of rovibrationally excited tolyl fragments was discussed. Our experiments suggest the presence of tolyl radicals in the interstellar medium as a precursor to methylated polycyclic aromatic hydrocarbons upon reaction with vinylacetylene (C 4 H 4 ).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗