Search NASA⌕ Search

SEARCH · Search NASA

Results for “Spectrometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Chemometric optimisation of pressurised liquid extraction for the determination of alliin and S‐allyl‐cysteine in giant garlic ( Allium ampeloprasum L.) by liquid chromatography tandem mass spectrometry

Abstract Introduction Giant garlic is a functional food that contains different kinds of bioactive molecules with beneficial effects on chronic noncommunicable diseases like diabetes and cardiovascular conditions. Considering biosynthesis pathways, abundance, and biological activity, alliin and S‐allyl‐cysteine were used as chemical markers of organosulphur compounds present in giant garlic. Objective To establish a chemometric optimisation of pressurised liquid extraction for the determination of alliin and S‐allyl‐cysteine in giant garlic by liquid chromatography tandem mass spectrometry (LC–MS/MS). Methodology Samples were blanched (ca. 90°C for 10 min) to inactivate alliinase and γ‐glutamyl transpeptidase enzymes and then freeze‐dried. Chemometric optimisation was performed via response surface methodology based on central composite design (CCD). Organosulphur compound yields were determined applying a validated LC–MS/MS method in multiple reaction monitoring (MRM) mode using the following transitions: for alliin m/z 178 → 74 and for S‐allyl‐cysteine m/z 162 → 41. Results According to CCD results, under constant conditions of pressure (1500 psi) and time (20 min), the optimal conditions for pressurised liquid extraction of alliin and S‐allyl‐cysteine were 70.75 and 68.97% v/v of ethanol in extraction solvent and 76.45 and 98.88°C as extraction temperature, respectively. Multiple response optimisation for the simultaneous extraction of both organosulphur compounds was established via desirability function. Under these conditions, 2.70 ± 0.27 mg g −1 dry weight (DW) of alliin and 2.79 ± 0.22 mg g −1 DW of S‐allyl‐cysteine were extracted. Conclusions These results clearly demonstrated that pressurised liquid extraction is an efficient green technique to extract bioactive organosulphur compounds from giant garlic. Extraction yields were significantly ( p < 0.05) higher than those obtained with conventional ultra‐turrax extraction.

Peterssen‐Fonseca, Darlene↗

Liquid Chromatography Mass Spectrometry study of eutectic bis(2,2-dinitropropyl) acetal/formal

This study is the first attempt to document methodology development undergone using liquid chromatography tandem quadrupole time of flight mass spectrometry (LC-QTOF) to investigate degradation products of eutectic bis(2,2-dinitropropyl) acetal/formal nitroplasticizer (called NP here). Method properties investigated are: desolvation temperature (°C) and spray voltage (V) of the electrospray ionization source, and the development of an acetone system rinse to prevent any residual contamination between sample injections. Details are given on why it is essential to investigate method optimization with changes shown in MS/MS analysis in addition to MS results. Trends in MS/MS analytic results reveal important relationships between baseline and aged materials. In addition to verification of previously proposed fragments, insights offered by this newly developed methodology will also identify new degradation products and shed light on the complexity of NP degradation chemistry.

36 MATERIALS SCIENCE↗

Absolute quantitation of propranolol from 200-μm regions of mouse brain and liver thin tissues using laser ablation-dropletProbe-mass spectrometry

Rationale: The ability to quantify drugs and metabolites in tissue with sub-mm resolution is a challenging but much needed capability in pharmaceutical research. To fill this void, a novel surface sampling approach combining laser ablation with the commercial dropletProbe automated liquid surface sampling system (LA-dropletProbe) was developed and presented here.Methods: Parylene C-coated 200 × 200 μm tissue regions of mouse brain and kidney thin tissue sections were analyzed for propranolol by laser ablation of tissue directly into a preformed liquid junction. Propranolol was detected by high performance liquid chromatography with positive ion mode electrospray ionization tandem mass spectrometry. Quantitation was achieved via application of a stable isotope-labeled internal standard and an external calibration curve.Results: Absolute concentration of propranolol determined from 200 × 200 µm tissue regions were compared to propranolol concentrations obtained from 2.3-mm-diameter tissue punches of adjacent, non-coated sections using standard bulk tissue extraction protocols followed by regular HPLC-MS/MS analysis. Average concentration of propranolol in both organs determined by the two employed methods agreed within ±12%. Furthermore, the relative abundance of phase II hydroxypropranolol glucuronide metabolites were recorded and found to be consistent with previous results.Conclusions: This work illustrates that depositing a thin parylene C layer onto thin tissue prior to analysis, which seals the surface and prevents direct liquid extraction of the drug from the tissue, coupled to the novel LA-dropletProbe surface sampling system is a viable approach for sub-mm resolution quantitative drug distribution analysis.

59 BASIC BIOLOGICAL SCIENCES↗

Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR-MS) peak intensity normalization for complex mixture analyses

Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR-MS) is a preferred technique for analyzing complex organic mixtures. Currently, there is no consensus normalization approach, nor an objective method for selecting one, for quantitative analyses of FT-ICR-MS data. We investigate a method to evaluate and score the amount of bias various normalization approaches introduce into the data. We evaluate the ability of the Statistical Procedure for the Analysis of Normalization Strategies (SPANS) to guide selection of appropriate normalization approaches for two different FT-ICR-MS datasets. Further, we test the robustness of SPANS results to changes in SPANS parameter values and assess the impact of using various normalization approaches on downstream statistical analyses. The normalization approach identified by SPANS differed for the two datasets. Normalization methods impacted the statistical significance of peaks differently, underscoring the importance of carefully evaluating potential methods. More consistent SPANS scores resulted when at least 120 significant peaks are used, where larger sets of peaks were obtained by increasing the p-value threshold. Interestingly, we show that Total Sum Scaling and highest peak normalization, used in previous studies, underperformed relative to SPANS-recommended normalization approaches. While there is no single, best normalization method for all datasets, SPANS provides a mechanism to identify an appropriate normalization method for analyzing FT-ICR-MS data quantitatively. As a result, the number of peaks used in the background distributions of SPANS contributes more significantly to the reproducibility of results than the p-value thresholds used to obtain those peaks.

47 OTHER INSTRUMENTATION↗

Trocylation of 3-quinuclidinol, a key marker for the chemical warfare agent 3-quinuclidinyl benzilate, for its enhanced detection at low levels in complex soil matrices by electron ionization gas chromatography–mass spectrometry

Detection of 3-quinuclidinol (3Q), a marker for the chemical warfare agent 3-quinuclidinyl benzilate, is very difficult by gas chromatography–mass spectrometry (GC/MS), providing low, broad signals even when analyzed in isolated form. Therefore, a method that can convert 3Q into a substrate with enhanced detectability by GC/MS would be an important tool for its analysis. 2,2,2-Trichloroethoxycarbonyl chloride (TrocCl) was used in the derivatization of 3Q in three different soils of varying composition and total organic content (Virginia type A soil, Nebraska EPA standard soil and Ottawa sand) when present at a 10 μg g -1 concentration in each. A direct derivatization protocol and one involving the pre-extraction of the analyte were evaluated for their individual efficiencies and subsequent analysis using electron ionization GC/MS. The practical derivatization of 3Q, when present at low levels (10 μg g -1 ) in three different soil matrices, was found to be rapid (1 h) and to take place smoothly at ambient temperature (and as low as 4°C). The method detection limit was determined to be 30 ng mL -1 for the Virginia type A soil, 49 ng mL -1 for the Nebraska EPA standard soil and 72 ng mL -1 for the Ottawa sand sample. An expedient and practical derivatization method for 3Q, a chemical warfare degradation product difficult to detect by GC/MS, has been realized using trichloroethyl chloroformate. The reaction provides 3Q-Troc, a derivative with better detectability than 3Q by electron ionization GC/MS such as peak sharpness and a unique mass spectrum for its unambiguous identification.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High-throughput mass spectrometry analysis using immediate drop-on-demand technology coupled with an open port sampling interface

Rationale: The sampling throughput of immediate drop-on-demand technology (I.DOT) coupled with an open port sampling interface (OPSI) is limited by software communication. To enable much-needed high-throughput mass spectrometry (MS) analysis capabilities, a novel software was developed that allows for flexible sample selection from a 96-well plate and for maximized analysis throughput using I.DOT/OPSI-MS coupling. Methods: Wells of a 96-well I.DOT plate were filled with propranolol solution and were used to test maximum sampling throughput strategies to minimize analysis time. Demonstration of chemical reaction monitoring was done using acid-catalyzed ring closure of 2,3-diaminonaphthalene (DAN) with nitrite to form 2,3-naphthotriazole (NAT). Analytes were detected in positive electrospray ionization mode using selected reaction monitoring. Results: A maximum throughput of 1.54 s/sample (7.41 min/96-well plate with three technical replicates) was achieved, and it was limited by the peak width of the MS signal resulting in an occasional slight overlap between the peaks. Further, relative standard deviation was 10 ± 1% with all tested sampling strategies. Chemical reaction monitoring of DAN to NAT using nitrite was successfully accomplished with 2 s/sample throughout showing almost complete transformation in 10 min with no signal overlap. Conclusions: This work illustrates the development of a noncontact, automated I.DOT/OPSI-MS system with improved throughput achieved through an optimized software interface. Its achievable analysis time and precision make it a viable approach for drug discovery and in situ reaction monitoring studies.

47 OTHER INSTRUMENTATION↗

FREDA: A Web Application for the Processing, Analysis, and Visualization of Fourier‐Transform Mass Spectrometry Data

The high-resolution measurement capability of Fourier-transform mass spectrometry (FT-MS) has made it a necessity for exploring the molecular composition of complex organic mixtures, like soil, plant, aquatic, and petroleum samples. This demand has driven a need for informatics tools to explore and analyze FT-MS data in a robust and reproducible manner. FREDA is an interactive web application developed to enable spectrometrists to format, process, and explore their FT-MS data without the need for statistical programming expertise. FREDA was built to explore outputs from a molecular identification tool, like CoreMS, and provide a suite of methods to filter data, compute chemical properties of peaks, statistically compare samples and groups of samples, conduct exploratory data analysis, and download the results with a report detailing all steps conducted. To demonstrate the utility of FREDA, an example analysis was conducted using FT-MS data from a soil microbiology study of samples collected in two different soil depths at the Sphagnum bog forest north of Grand Rapids, Minnesota. Differences between the two depths are observed using Kendrick, Gibbs free energy, and van Krevelen plots. G-tests are used to quantify a significant difference between the groups. All analyses and plotting are conducted using only the FREDA application. FREDA is an open-source and readily available web application that allows users to explore and make statistically valid conclusions about their FT-MS data. The application is available online (https://map.emsl.pnnl.gov/app/freda) with a tutorial web series (https://youtu.be/k5HLE2kNSBY?si=yB6sGoyvzxrFf5MP) and freely accessible code on Github (https://github.com/EMSL-Computing/FREDA).

47 OTHER INSTRUMENTATION↗

Temporal Sampling of Enzymes from Live Cells by Localized Electroporation and Quantification of Activity by SAMDI Mass Spectrometry

Abstract Measuring changes in enzymatic activity over time from small numbers of cells remains a significant technical challenge. In this work, a method for sampling the cytoplasm of cells is introduced to extract enzymes and measure their activity at multiple time points. A microfluidic device, termed the live cell analysis device (LCAD), is designed, where cells are cultured in microwell arrays fabricated on polymer membranes containing nanochannels. Localized electroporation of the cells opens transient pores in the cell membrane at the interface with the nanochannels, enabling extraction of enzymes into nanoliter‐volume chambers. In the extraction chambers, the enzymes modify immobilized substrates, and their activity is quantified by self‐assembled monolayers for matrix‐assisted laser desorption/ionization (SAMDI) mass spectrometry. By employing the LCAD‐SAMDI platform, protein delivery into cells is demonstrated. Next, it is shown that enzymes can be extracted, and their activity measured without a loss in viability. Lastly, cells are sampled at multiple time points to study changes in phosphatase activity in response to oxidation by hydrogen peroxide. With this unique sampling device and label‐free assay format, the LCAD with SAMDI enables a powerful new method for monitoring the dynamics of cellular activity from small populations of cells.

Mukherjee, Prithvijit↗

Heterogeneous Catalysis by Fullerene C 60 : Photocatalytic Dehydro‐Dimerization of Primary Amines and Tetrahydroquinolines Studied Using Thread Spray Mass Spectrometry

Abstract Removal of a catalyst after a catalytic process is a time‐consuming and challenging process. In this paper, a fullerene catalyst coated on cellulose thread is developed and applied it in a heterogeneous photoreaction screening via a thread spray mass spectrometry (MS) platform. The surface of the cellulose thread is modified with NH 2 groups, which subsequently allows immobilization of fullerene C 60 on the thread. The final fullerene functionalized thread is placed in a glass capillary and the solution of the reactant to be interrogated is added. The assembly of thread and glass capillary is placed in front of a mass spectrometer, which serves as an online photoreaction platform after a light source and direct current high voltage are applied. As an ambient ionization approach, the photocatalytic reaction screening platform enabled real‐time MS characterization of products and intermediates and using only nanomole quantities of reactants. Fullerene C 60 is identified to facilitate dehydro‐dimerization reactions from amines. Norharmane shows a unique photo‐oxygenated dimer formation. The functionalized threads immobilized with fullerene C 60 are reusable, confirming the heterogeneous nature of the platform. Thus, this system provided real‐time screening of reactions catalyzed by fullerene C 60 and a means to investigate the reaction mechanism.

Chemistry↗

Quantitation of amiodarone and N-desethylamiodarone in single HepG2 cells by single-cell printing-liquid vortex capture-mass spectrometry

Quantitative measure of a drug and its associated metabolite(s) with single-cell resolution is often limited by sampling throughput or other compromises that limit broad use. Here, we demonstrate the use of single-cell printing-liquid vortex capture-mass spectrometry (SCP-LVC-MS) to quantitatively measure the intracellular concentrations of amiodarone (AMIO) and its metabolite, N-desethylamiodarone (NDEA), from thousands of single cells across several AMIO incubation concentrations ranging from 0 to 10 μM. Concentrations obtained by SCP-LVC-MS were validated through comparison with average assays and traditional measurement of cells in bulk. Average of SCP-LVC-MS measurements and aggregate vial collection assay the concentrations differed by < 5%. Both AMIO and NDEA had clear log-normal distributions with similar standard deviation of concentrations in the cell population. The mean of both AMIO and NDEA intracellular concentrations were positively correlated with AMIO incubation concentration, increasing from 0.026 to 0.520 and 0.0055 to 0.048 mM for AMIO and NDEA, respectively. The standard deviation of AMIO and NDEA log-normal distribution fits were relatively similar in value across incubation concentrations, 0.15–0.19 log 10 (mM), and exhibited a linear trend with respect to each other. The single cell-resolved conversion ratio of AMIO to NDEA increased with decreasing incubation concentration, 7 ± 2%, 18 ± 3%, and 20 ± 7% for 10.0, 1.0, and 0.1 μM AMIO incubation concentrations, respectively. Finally, association with simultaneously measured lipids had several ions with statistically significant difference in intensity but no clear correlations with AMIO intracellular content was observed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Determining P, S, Br, and I content in uranium by triple quadrupole inductively coupled plasma mass spectrometry

The trace impurities of a uranium ore concentrate (UOC) can be examined to determine mine source, methods of production, and quality. This study presents a method to determine the concentration of halides and main group elements, specifically P, S, Br and I, utilizing triple quadrupole inductively coupled plasma–mass spectrometry. These analytes were measured in a uranium matrix to simulate a UOC sample. The concentrations determined with this method showed agreement with known values. Solutions with and without uranium were compared. A UOC certified reference material, CUP-2, was analyzed to further demonstrate the effectiveness of the method.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Analysis of an irradiated uranium sample for source attribution without chemical separation using microplasma ionization and ultrahigh resolution mass spectrometry

The use of element isotope ratios has great potential in not only determining the reactor type used to produce plutonium (Pu) but also in determining the burnup and the time since irradiation. While a powerful nuclear forensic technique, determining element isotope ratios is complicated by severe isobaric interferences when performed on typical inductively coupled plasma mass spectrometers. Such analyses require extensive chemical separations prior to analysis to alleviate the inter-elemental isobars. Ultrahigh mass resolution spectrometry provides a potential alternative, greatly reducing the complexity of sample preparation and turnaround times for these critical measurements. To demonstrate the power of the approach, a sample of irradiated, depleted uranium was analyzed with the liquid sampling—atmospheric pressure glow discharge ion source coupled to an Orbitrap mass spectrometer. The Orbitrap is augmented with an external data acquisition system, Spectroswiss’s FTMS-Booster X2T, allowing collection of extended ion transients, providing higher mass resolution. In using this approach, the 150 Sm/ 149 Sm and 152 Sm/ 149 Sm isotope ratios were found to be within 20% of predicted values without any chemical separations and without mass bias corrections. In addition, the 240 Pu/ 239 Pu isotope ratio was determined, free from the 238 UH + interferences common to the ICP-MS platforms, while at the same time allowing for the determination of U isotopic signatures. While these demonstrative results are from a single sample, the advantages of the microplasma/ultrahigh mass resolution approach to intra-element isotope ratio determinations are clear.

Fuel burnup↗

Probing substrate water access through the O1 channel of Photosystem II by single site mutations and membrane inlet mass spectrometry

Abstract Light-driven water oxidation by photosystem II sustains life on Earth by providing the electrons and protons for the reduction of CO 2 to carbohydrates and the molecular oxygen we breathe. The inorganic core of the oxygen evolving complex is made of the earth-abundant elements manganese, calcium and oxygen (Mn 4 CaO 5 cluster), and is situated in a binding pocket that is connected to the aqueous surrounding via water-filled channels that allow water intake and proton egress. Recent serial crystallography and infrared spectroscopy studies performed with PSII isolated fromThermosynechococcus vestitus(T. vestitus) support that one of these channels, the O1 channel, facilitates water access to the Mn 4 CaO 5 cluster during its S 2 →S 3 and S 3 →S 4 →S 0 state transitions, while a subsequent CryoEM study concluded that this channel is blocked in the cyanobacteriumSynechocystis sp.PCC 6803, questioning the role of the O1 channel in water delivery. Employing site-directed mutagenesis we modified the two O1 channel bottleneck residues D1-E329 and CP43-V410 (T. vestitusnumbering) and probed water access and substrate exchange via time resolved membrane inlet mass spectrometry. Our data demonstrates that water reaches the Mn 4 CaO 5 cluster via the O1 channel in both wildtype and mutant PSII. In addition, the detailed analysis provides functional insight into the intricate protein-water-cofactor network near the Mn 4 CaO 5 cluster that includes the pentameric, near planar ‘water wheel’ of the O1 channel.

Plant Sciences↗

Calcium fluoride as a dominating matrix for quantitative analysis by laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS): A feasibility study

Here, calcium fluoride formed by the reaction between ammonium bifluoride and calcium chloride was investigated as a dominating matrix for quantitative analysis by laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS). Transformation from a solid sample to the calcium fluoride-based matrix permitted quantitative analysis based on calibration standards made from elemental standards. A low abundance stable calcium isotope, i.e. 44 Ca + , was monitored as the internal standard for quantitative analysis by LA-ICP-MS. Correlation coefficient factors for multiple elements were obtained with values over 0.999. The results for multiple elements in a certified reference material of soil (NIST SRM 2710a) agreed with the certified values in the range of expanded uncertainty, indicating the present method was valid for quantitation of elements in solid samples.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Mass spectrometry and spectroscopic characterization of a tetrameric photosystem I supercomplex from Leptolyngbya ohadii , a desiccation-tolerant cyanobacterium

Cyanobacteria inhabiting desert biological soil crusts face the harsh conditions of the desert. They evolved a suite of strategies toward desiccation-hydration cycles mixed with high light irradiations, etc. In this study we purified and characterized the structure and function of Photosystem I (PSI) from Leptolyngbya ohadii, a desiccation-tolerant desert cyanobacterium. We discovered that PSI forms tetrameric (PSI-Tet) aggregate. We investigated it by using sucrose density gradient centrifugation, clear native PAGE, high performance liquid chromatography, mass spectrometry (MS), time-resolved fluorescence (TRF) and time-resolved transient absorption (TA) spectroscopy. MS analysis identified the presence of two PsaB and two PsaL proteins in PSI-Tet and uniquely revealed that PsaLs are N-terminally acetylated in contrast to non-modified PsaL in the trimeric PSI from Synechocystis sp. PCC 6803. Chlorophyll (Chl) a fluorescence decay profiles of the PSI-Tet performed at 77 K revealed two emission bands at ∼690 nm and 725 nm with the former appearing only at early delay time. The main fluorescence emission peak, associated with emission from the low energy Chls a, decays within a few nanoseconds. TA studies demonstrated that the 725 nm emission band is associated with low energy Chls a with absorption band clearly resolved at ∼710 nm at 77 K. As a result, our work suggests that the heterogenous composition of PsaBs and PsaL in PSI-Tet is related with the adaptation mechanisms needed to cope with stressful conditions under which this bacterium naturally grows.

59 BASIC BIOLOGICAL SCIENCES↗

Evaluation of different getter substrates using two-dimensional gas chromatography with time of flight mass spectrometry

We report while understanding hydrogen uptake by organic based getters such as 1,4-bis(phenylethynyl)benzene (DEB) combined with a palladium(0)bis(dibenzylideneacetone) (Pd(dba) 2 ) catalyst is essential, another crucial element to understand is the decomposition of the DEB, Pd(dba) 2 , and/or substrate material. The breakdown of these materials may create unwanted volatiles, which may interact with and lead to deterioration of sensitive materials. Moreover, it is critical to understand if different substrates cause the getter and/or catalyst to degrade in different manners. Utilizing comprehensive two-dimensional gas chromatography (GC×GC) with time-of-flight mass spectrometry (TOFMS), the presence of volatiles located in the headspace of various DEB/Pd(dba) 2 getter substrates is examined. These samples include a getter infused silicone foam, a hydrogenated getter infused silicone foam, an activated carbon getter pellet, and a hydrogenated activated carbon getter pellet. Application of Fisher ratio (F-ratio) analyses lead to the identification of several compounds that are generated or consumed through the hydrogenation process. These include benzene derivatives such as bibenzyl, benzaldehyde, and vinyl benzoate in the activated carbon pellets and 1,5-diphenyl-3-pentanone, toluene, styrene, and 1–1'(2-pentene 1,5-diyl)bis benzene in the silicone foams, and alkane/alkene derivatives such undecane, 4-tridecene, and decane in the activated carbon pellets and 2,6-dimethyl undecane in the silicone foams. Further comparison of the different hydrogenated getter substrates (e.g. activated carbon pellet and silicone foam) indicates that the different substrates alter the decomposition products created from the degradation of the DEB and Pd(dba) 2 .

47 OTHER INSTRUMENTATION↗

Reactions of atomic thorium and uranium cations with CF 4 studied by guided ion beam tandem mass spectrometry

The fundamental chemistry of the actinides continues to be an area of interest because of their use in nuclear fuel cycles. Here, the kinetic energy dependences of the reactions of thorium and uranium cations with CF 4 were studied using guided ion beam tandem mass spectrometry. The products observed include AnF x + (An = Th or U, x = 1-3) and CF y + (y = 1-3). Although most reactions are exothermic according to literature thermochemistry, all cross sections display strong endothermic features indicating a restriction in the reactivity at low energies. For both actinides, only the AnF + + CF 3 product channel is observed at low energies; however, its formation proceeds very inefficiently. Furthermore, these results indicate that the reactions of Th + and U + with CF 4 are not thermodynamically driven and suggest that the low-energy reactivity results from precise alignment of the reactants.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Non-traditional stable isotope measurements using laser desorption Orbitrap mass spectrometry: Implications for planetary missions.

Isotopic fractionation recorded in planetary materials provides insights into physical, chemical, and/or potential biological processes occurring on Solar System bodies. As we enter into the next decades of planetary exploration, the crucial information revealed by isotopic compositions of rocky and icy samples mandates that next generation spaceflight instrumentation possess the capability to measure isotope ratios in situ with sufficient precision/accuracy to distinguish between such processes. Here, in addition to identifying and fingerprinting complex organic materials with high accuracy and ultrahigh mass resolutions, laser desorption Orbitrap™ mass spectrometry (LD-O-MS) has the capability to determine the elemental and isotopic composition of solid planetary materials such as rock, regolith, organics, ice, etc. Here, we use a space-qualified LD-O-MS instrument comprising a 266 nm ultraviolet (UV) laser and Orbitrap mass analyzer ruggedized for planetary applications to investigate the stable isotopic composition of Ti and Zn metal plates. Based on the isotopic analyses, we constrain the performance of the CORALS instrument to sub per mille (‰) level accuracy and precision for Ti and at the per mille (‰) level for Zn. An LD-O-MS instrument is a versatile instrument capable of measuring isotopic composition of a variety of planetary samples and would constitute a critical instrument in the exploration of various planetary bodies including but not limited to Moon, Mars, Enceladus and other ocean or icy worlds, Ceres and other asteroids, and comets, thereby answering several high-priority questions pertaining to the formation and evolution of our Solar System.

58 GEOSCIENCES↗