At least 289 records · Page 16

Digital Twin for Chemical Science (DTCS) v0.01

Directly visualizing the trajectories of chemistry can unravel novel insights into the behavior of catalysts, gas phase reactions, photo-induced dynamics, and building blocks for quantum information processing. The ability of explicitly identifying, tracking, and tagging the exchange of matter, hence the annihilation and creation of new chemical species, can be best realized through a close coupling of theory and experiment. While the synchrotron-based characterization facilities propelled rapidly in its hardware, providing higher brightness, better resolution, and more precision, the software infrastructure is lagging. We developed DTCS (Digital Twin for Chemical Science) v.01, a central platform that faithfully mimics advanced instrumentations in Scientific User Facilities, by solving a variety of technical challenges in data acquisition, analysis, and model-driven interpretation. Rooted in physics and accelerated by AI, we validated this concept by direct comparison with precise experimental X-ray Photoelectron Spectroscopy (XPS) observations using a ubiquitous metal-water interfacial scenario, i.e., Ag/H2O as our main narrative. The DTCS v.01 input mirrors how the bench chemists work, with the output directly linked to the end station computer, thereby providing a user-friendly, knowledge-driven, and accessible user experience with mechanistic insights standardized in a way that are ready to be published, versioned, and transferred flexibly.

Qian, Jin↗

Determining hexavalent chromium transport properties in alkaline nuclear waste using nuclear magnetic resonance spectroscopy

This study focuses on the transport properties of hexavalent chromium, specifically the chromate anion, to improve predictive models and environmental remediation strategies for Cr(VI) migration. Using 53 Cr Nuclear Magnetic Resonance (NMR) spectroscopy, the research quantifies chromate in multicomponent electrolytes replicating nuclear waste conditions at the Hanford Site in Washington State. The consistency of the 53 Cr NMR signal integral with chromate concentration, despite varying matrix compositions, establishes it as a reliable concentration indicator. The transport properties of chromate in an alkaline solution were assessed using relaxation-based measurements via saturation recovery and Carr-Purcell-Meiboom-Gill experiments, determining spin-lattice and spin-spin relaxation times. These measurements, combined with the Bloembergen-Purcell-Pound equation, helped estimate the rotational correlation time and the 53 Cr self-diffusion coefficient using Stokes-Einstein-Debye and Stokes-Einstein equations. Direct measurements were obtained through pulsed field gradient stimulated echo 53 Cr NMR spectroscopy. Monte Carlo simulations further estimated uncertainty propagation. The results enhance comprehension of chromate transport and highlight prospects for identifying transport properties of NMR-active nuclei, traditionally considered unreachable.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Resolving discrepancies in bang-time predictions for indirect-drive ICF experiments on the NIF: Insights from the Build-A-Hohlraum campaign

This study investigated discrepancies between measured and simulated x-ray drive in Indirect-Drive Inertial Confinement Fusion (ID-ICF) hohlraums at the National Ignition Facility. Despite advances in radiation-hydrodynamic simulations, a consistent “drive deficit” remains. Experimentally measured ID-ICF capsule bang-times are systematically 400–700 ps later than simulations predict. The Build-A-Hohlraum (BAH) campaign explored potential causes for this discrepancy by systematically varying hohlraum features, including laser entrance hole (LEH) windows, capsules, and gas fills. Overall, the agreement between simulated and experimental x-ray drive was found to be largely unaffected by these changes. The data allow us to exclude some hypotheses put forward to potentially explain the discrepancy. Errors in the local thermodynamic equilibrium (LTE) atomic modeling, errors in the modeling of LEH closure, and errors due to a lack of plasma species mix physics in simulations are shown to be inconsistent with our measurements. Instead, the data support the hypothesis that errors in NLTE emission modeling are a significant contributor to the discrepancy. X-ray emission in the 2–4 keV range is found to be approximately 30% lower than in simulations. This is accompanied by higher than predicted electron temperatures in the gold bubble region, pointing to errors in non-LTE modeling. Introducing an opacity multiplier of 0.87 on energy groups above 1.8 keV improves agreement with experimental data, reducing the bang-time discrepancy from 300 to 100 ps. These results underscore the need for refined NLTE opacity models to enhance the predictive power of hohlraum simulations.

Band emission↗

Collisionless Larmor coupling and blob formation in a laser-plasma expanding into a magnetized ambient plasma

Collisionless Larmor coupling is a fundamental process in space and astrophysical plasmas that enables momentum transfer between an expanding plasma and a magnetized ambient medium. Here, in this paper, we report on the laboratory experimental study of Larmor coupling leading to the formation of a plasma blob associated with a laser-driven, super-Alfvénic plasma flow on the Large Plasma Device at the University of California, Los Angeles. The high-repetition rate enables systematic spatial and temporal scans of the plasma evolution using Doppler spectroscopy, as well as measurements of the magnetic field, electrostatic field, and self-emission of both debris and ambient ions using filtered imaging. We observe the self-focusing of the laser-produced plasma and the formation of a secondary diamagnetic cavity associated with a blob composed of background ions. Doppler spectroscopy reveals the transverse velocity distribution of the background ions, providing direct evidence of ion energization via Larmor coupling. The systematic spatial and temporal scans enabled by the high-repetition-rate experiment allow for a detailed characterization of the ion dynamics. These experimental observations are supported by numerical simulations that provide more insight into the kinetic-scale physics associated with blob formation as well as the role of the ambient plasma density.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of a Platform for High-Resolution Ion Mobility Separations Coupled with Messenger Tagging Infrared Spectroscopy for High-Precision Structural Characterizations

The ability to uniquely identify a compound requires highly precise and orthogonal measurements. Here we describe a newly developed analytical platform that integrates high resolution ion mobility and cryogenic vibrational ion spectroscopy for high-precision structural characterizations. This platform allows for the temporal separation of isomeric/isobaric ions and provides a highly sensitive description of the ion’s adopted geometry in the gas phase. The combination of these orthogonal structural measurements yields precise descriptors that can be used to resolve between and confidently identify highly similar ions. The unique benefits of our instrument, which integrates a structures for lossless ion manipulations ion mobility (SLIM IM) device with messenger tagging infrared spectroscopy, include the ability to perform high-resolution ion mobility separations and to record the IR spectra of all ions simultaneously. The SLIM IM device, with its 13 m separation path length, allows for multipass experiments to be performed for increased resolution as needed. It is integrated with an Agilent qTOF MS where the collision cell was replaced with a cryogenically held (30 K) TW-SLIM module. The cryo-SLIM is operated in a novel manner that allows ions to be streamed through the device and collisionally cooled to a temperature where they can form noncovalently bound N 2 complexes that are maintained as they exit the device and are detected by the TOF mass analyzer. The instrument can be operated in two modes: IMS+IR where the IR spectra for mobility-selected ions can be recorded and IR-only mode where the IR spectra for all mass-resolved ions can be recorded. In IR-only mode, IR spectra (400 cm –1 spectral range) can be recorded in as short as 2 s for high throughput measurements. Further, this work details the construction of the instrument and modes of operation. It provides initial benchmarking of CCS and IR measurements to demonstrate the utility of this instrument for targeted and untargeted approaches.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Unraveling the CO Oxidation Mechanism over Highly Dispersed Pt Single Atom on Anatase TiO 2 (101)

Catalysts with noble metals deposited as single atoms on metal oxide supports have recently been studied extensively due to their maximized metal utilization and potential for performing difficult chemical conversions owing to their unique electronic properties. Understanding of the reaction mechanisms on supported single-metal atoms is still limited but is highly important for designing more efficient catalysts. In this study, we report the complexity of the CO oxidation reaction mechanism on Pt single atoms supported on anatase TiO 2 (Pt SA /a-TiO 2 ) by coupling density functional theory (DFT) calculations and microkinetic analysis with kinetic measurements, in situ/operando infrared, and X-ray absorption spectroscopies. Starting from the adsorbed Pt SA occupying an O vacancy induced by reductive pretreatment, we show that CO oxidation follows a complex mechanism consisting of initiation steps to reorganize the active site and multibranch reactive cycles, with the Pt SA /a-TiO 2 catalyst not returning to its initial configuration. The initiation step consists of CO and O 2 adsorption healing the O vacancy, followed by CO oxidation using gas-phase CO to form Pt(CO). The reactive cycle alternates O 2 adsorption and dissociation to oxidize the catalyst to Pt(O)(O)(CO) and branching pathways of competing Langmuir–Hinshelwood (LH)- or Eley–Rideal (ER)-type CO oxidation steps to reduce it again to Pt(CO). In situ/operando infrared experiments, including cryogenic CO adsorption and isotopic CO exchange, confirm the combined involvement of strongly adsorbed CO and gas-phase CO in an Eley–Rideal step along the reaction cycle. Microkinetic modeling shows that Pt single atoms are present in a mixture of Pt(CO), Pt(CO)(O 2 ), Pt(O)(CO)(O 2 ), and Pt(CO)(CO 3 ) structures as the main intermediates during steady-state CO oxidation, all having the C–O vibrational stretch close to the experimentally observed value of 2115 cm –1 . Microkinetic modeling also shows that the fractional orders of CO and O 2 measured experimentally originate from multiple steps with a high degree of rate control and not from a simple competitive adsorption. The results demonstrate the complex reaction pathways that even CO oxidation on a simple single-atom system can follow, providing mechanistic insights for designing efficient Pt-based single-atom catalysts. Here, we further show that microkinetic modeling results are sensitive to changes in energies of intermediate and transition states within errors of density functional theory, which can ultimately lead to incorrect conclusions regarding the reaction pathways and most abundant reaction intermediates if not accounted for by experiments.

36 MATERIALS SCIENCE↗

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER↗

Tunable Few-Layer van der Waals Crystals and Heterostructures as Emerging Energy and Quantum Materials (Final Technical Report)

2D and layered (van der Waals) semiconductors offer extraordinary opportunities for manipulating optically excited charge carriers, many-body excitations, and non-charge based quantum numbers. To date, research has focused on a limited group of materials, mostly transition metal dichalcogenides in the monolayer limit. Other van der Waals semiconductors, and especially few-layer to multilayer crystals and their heterostructures, carry large potential for the discovery of phenomena of interest for future energy and information technologies. But they remain largely unexplored, often due to a lack of access to high-quality materials and approaches for measuring their properties at the relevant scales. The goal of this project was to develop an EPSCoR-State/National Laboratory Partnership that addresses the challenges of preparing high-quality van der Waals semiconductors and of probing their structure, composition, and especially their optoelectronic and photonic properties, near the atomic scale using electron microscopy techniques. A central component of the project was the development of advanced methods for electron microscopy and electron-excited spectroscopy, taking advantage of unique samples as well as leading capabilities and expertise at the partner institutions. Efforts to advance leading-edge techniques was supported by ancillary developments, such as precision sample preparation for electron microscopy/spectroscopy, coordinated chemical imaging, and analytical electron microscopy. Experiments in materials synthesis and technique development were closely linked to theory and computation. The results obtained under this project yielded multifaceted benefits to the involved partners and their institutions, DOE-BES, the wider scientific community, and society at large, particularly in the State of Nebraska through dividends from knowledge and human capital generated under the project.

36 MATERIALS SCIENCE↗

Validation of the ERO2.0 code using W7-X and JET experiments and predictions for ITER operation

Abstract The paper provides an overview of recent modelling of global material erosion and deposition in the fusion devices Wendelstein 7-X (W7-X), JET and ITER using the Monte-Carlo code ERO2.0. For validating the modelling tool in a three-dimensional environment, W7-X simulations are performed to describe carbon erosion from the graphite test divertor units, which were equipped in operational phase OP 1.2 and analysed post-mortem. Synthetic spectroscopy of carbon line emission is compared with experimental results from the divertor spectrometer measurement system, showing a good agreement in the e-folding lengths in the radial intensity profiles of carbon. In the case of metallic wall materials, earlier modelling of the Be/W environment in JET and ITER is revisited and extended with an updated set of sputtering and reflection data, as well as including the mixing model for describing the Be/W dynamics in the divertor. Motivated by recent H/D/T isotope experiments in JET, limited and diverted configuration pulses are modelled, showing the expected trend of both Be and W erosion increasing with isotope mass. For the JET diverted configuration pulses, it is shown that Be migrates predominantly to the upper part of the inner divertor where it initially leads to strong W erosion. With longer exposure time, the growth of a Be deposited layer leads to a reduction of W erosion in that region. A similar trend is observed in simulations of the ITER baseline Q = 10 scenario, however with a more symmetric Be migration pattern leading to deposition also on the outer divertor.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-pressure Cr 3+ luminescence and Raman spectroscopy of a natural MgAl 2 O 4 spinel to ∼60 GPa

Cr 3+ luminescence and Raman spectroscopy of a natural spinel were collected up to ∼60 GPa at ambient temperature using a Ne or a 4:1 methanol-ethanol mixture as the pressure transmitting media. Here, in the Ne experiments above ∼40 GPa, and in the 4:1 methanol–ethanol experiments above ∼20 GPa, all luminescence emission lines shift non-linearly, and by 59 GPa the spectra are broadened and are significantly changed. The Raman modes shift smoothly to higher frequencies with pressure, with a slight change in slope above 40 GPa, with no kinks or discontinuities. By ∼60 GPa, only the most intense Eg mode remains resolvable, appearing broadened and reduced in intensity. The change in slope in the Raman modes and luminescence bands may be due to a change in the compression mechanism of spinel. When spinel was decompressed from 40 GPa all changes were fully reversible; however, when the samples were decompressed from 54 to 60 GPa in Ne and 59 GPa in 4:1 methanol-ethanol the spectra were irreversibly changed. The change in the luminescence spectra and the Raman spectra are likely due to a pressure induced disorder of the anions or partial amorphization between 40 and 60 GPa.

Cr3+↗

Insights into catalyst degradation during alkaline water electrolysis under variable operation

Energy conversion technologies that are key to decarbonization efforts face significant durability challenges due to variable operation. Understanding the impact of variable operation on catalytic stability and identifying the key variables that dictate degradation is crucial for developing robust technologies. Here, we present a comprehensive investigation of the effects of variable operation on liquid alkaline water electrolysis. Our findings reveal that variable operation induces severe degradation of Ni, Fe, and Co catalytic films that is not observed during steady-state operation. By systematically interrogating the electrode discharge during simulated shutdown tests using Raman spectroscopy and mass spectrometry techniques, we uncover significant alterations caused by reverse currents in real time. These include changes in crystal structure, composition, film thickness, electronic conductivity, and dissolution rates. Lab-scale electrolyzer experiments further highlight the impact of variable operation on catalyst materials under relevant conditions. Finally, we provide guidelines for leveraging these insights to advance electrocatalysis research. This work underscores the importance of integrating realistic stressors into stability testing and offers practical guidelines for catalyst design, performance evaluation, and industrial implementation. Collectively, insights from this study will drive the development of more resilient energy conversion technologies.

Marquez, Raul A. [Univ. of Texas, Austin, TX (Unit↗

Acid-catalyzed C–H reductive elimination from Au (III)

An unusual mode of C–H reductive elimination from a Au III complex catalyzed by acid is reported. The addition of triflic acid (HOTf) to [( tBu PCP)Au III –H]OTf (1-OTf, tBu PCP = 2,6-C 6 H 3 (CH 2 P t Bu 2 ) 2 promotes formal C–H reductive elimination. The Au I product [( tBu P(C–H)P)Au I ]OTf (2-OTf, tBu P(C–H)P = κ 2 (1,3-C 6 H 4 (CH 2 P t Bu 2 ) 2 )) was characterized by NMR spectroscopy and X-ray diffraction. It was shown that the reductive elimination of 1-OTf has a dependence on the identity of the acid catalyst which cannot be explained by acid strength. Mechanistic experiments are consistent with a concerted mechanism for C–H reductive elimination involving participation of basic moieties on the acid.

Ardon, Yotam [University of Pennsylvania, Philadel↗

Accurate point defect energy levels from non-empirical screened range-separated hybrid functionals: The case of native vacancies in ZnO

We use density functional theory (DFT) with non-empirically tuned screened range-separated hybrid (SRSH) functionals to calculate the electronic properties of native zinc and oxygen vacancy point defects in ZnO, and we predict their defect levels for thermal and optical transitions in excellent agreement with available experiments and prior calculations that use empirical hybrid functionals. Furthermore, the ability of this non-empirical first-principles framework to accurately predict quantities of relevance to both bulk- and defect-level spectroscopy enables high-accuracy DFT calculations with non-empirical hybrid functionals for defect physics, at a reduced computational cost.

Defects↗

Rare Earth Elements (REEs) Measurement in Coal and Rock Mineral Matrices

Although critical minerals including rare earth elements (REEs) can be analyzed in laboratory by some established and reliable laboratory based analytical techniques, their in-situ measurements in the field have always been challenging. For identification of REE-rich sites and REEs distribution measurement, portable field applicable technologies are paramount. As Laser-induced breakdown spectroscopy (LIBS) has enormous potential for field measurement, it has been explored for REEs measurements by many research groups. However, most of the studies are still dealing with simulated samples with traditional bench top experiments. In real world, REEs are available in various types of natural complex matrices in low content depending on the geographical locations. Considering this, LIBS has been evaluated for REE measurement in two different complex coal and rock mineral matrices representing some natural REE-rich sites. In addition, multiple samples collected from some natural sites in Wyoming, USA were experimented by using NETL’s bench top as well as miniaturized prototype setups for REE measurements.

Bhatt, Chet R.↗

Multi-site Milling Strategy Reveals Significant Variation in Biomass Composition of Switchgrass ( Panicum virgatum ) Grown at Ten Locations

Cell wall composition influences biomass use as a forage and as a feedstock for biofuel and chemical conversion. To examine the influence of environment on composition of switchgrass (Panicum virgatum L.), we utilized a multi-environment experiment consisting of clones of switchgrass genotypes grown at up to ten locations in the continental US. We tested the influence of different milling treatments on biomass composition trait predictions via near-infrared reflectance spectroscopy (NIRS). We found that most compositional trait predictions (29/34) were significantly different (P < 0.05) when a single lot of biomass was subjected to disparate milling treatments, i.e., knife milling vs. knife milling with an additional cyclone milling. Further, depending on the plant material tested, three to eight compositional trait predictions vary (P < 0.05) when identical biomass was knife milled at different sites followed by cyclone milling at a single site, including for traits such as Klason lignin, nitrogen, and carbon. In some cases, variation due to milling site exceeded environmentally induced compositional variation of a single switchgrass genotype grown at different sites. From these observations, we recommend a protocol with two sequential millings that decouples growth environment from a particular mill. Utilizing this approach, we found that 46/46 biomass composition traits from the warm season herbaceous forage and switchgrass bioethanol NIRS equations vary significantly (P < 0.001) in clones of a switchgrass genotype (WBC) grown at ten sites, with the growth site representing the largest average source of variation (41%). This multi-site milling approach can be used to examine environmental and gene-by-environment influences on composition with the goal of optimizing cell wall composition in different environments for biomass utilization.

09 BIOMASS FUELS↗

Fabrication of yeast engineered porous 13X adsorbent layers for CO 2 capture

This study investigates a novel environmentally friendly coating technique using yeast fermentation to obtain super porous Zeolite 13X adsorbent layers through freeze-drying technique for CO 2 capture applications. Several mass ratios of sugar to yeast were used to control the porosity and pore sizes in the adsorbent layer. A unique peeling process was integrated to obtain foamy, hollow structures to have deeper layer accessibility of adsorbent for adsorption applications. These coated adsorbent layers were experimentally characterized as a function of the mass ratio of sugar to yeast and adsorbent solid fraction. Scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDS), and Fourier-transform infrared spectroscopy (FT-IR) are used to analyze the coated layers. Here, the void fraction for coated samples is found to vary between 0.48 and 0.56, making the samples applicable for adsorption applications. Adsorption performance experiments are performed to test the coated samples' performance compared to 13X powder. Due to their simplistic fabrication, cost-effectiveness, rapid pore formation, and high adsorption capacity, these porous 13X layers hold potential for large-scale fabrication and CO 2 capture applications.

Adsorbent coating↗

Metal Identity and Coordination Environment Modulate Single-Atom Catalyst Stability During Electrocatalysis

A major hurdle to the implementation of single-atom catalysts (SACs) in real-world systems is a poor understanding of their stability under operating conditions, which is particularly relevant due to the high surface free energy of SACs. Here, we evaluated the aggregation behavior of a suite of SACs varied by metal identity (Fe, Co, Ni, and Cu) during electrocatalytic nitrate reduction using in situ X-ray absorption spectroscopy. The metal center had significant influence on reconstruction, where under identical applied reductive potentials, SACs underwent varying levels of reconstruction, ranging from no discernible change to complete reduction into metallic nanoparticles. Such in situ experiments revealed Cu SACs to be the most susceptible to aggregation, prompting a deeper investigation into how coordination environment (O-, B-, and N-graphene) affected Cu SAC aggregation. We further conducted density functional theory calculations to elucidate the relationship between Cu SAC structure and stability. This work deconvolutes the relationship between SAC architecture and stability, which is essential to evaluate and explain for the realization of SACs for electrocatalysis.

36 MATERIALS SCIENCE↗

Investigation of Undissolved Solids from Salt Waste Processing Facility (SWPF) Salt Batches Collected via Filtration

SRNL researchers performed six experiments wherein 0.1 μm-grade stainless steel filters were used to filter samples pulled from salt batches 6, 9B, and 11B, without the addition of monosodium titanate. Three of these experiments were performed to collect filterable solids from each salt batch and characterize trapped solids via scanning electron microscopy. The remaining three experiments were performed to collect and then dissolve the same solids using 3.5 M nitric acid (similar to that employed in the Salt Waste Processing Facility) for characterization via Inductively-coupled plasma atomic emission spectroscopy.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗