Search NASA⌕ Search

SEARCH · Search NASA

Results for “Storage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Techno-economic Analysis of the Cryogenic Flux Capacitor Compared to Other forms of Hydrogen Production and Storage

The Cryogenic Flux Capacitor (CFC) is a cold, dense energy storage core that is being studied in the cryo-compressed, about 300 bar and 80K, region of gaseous hydrogen (GH2) storage and liquid hydrogen (LH2) region near the normal boiling point. The hydrogens storage is improved by physically bonding the molecules within the nanoscale pores of the aerogel composite blanket material. The process of bonding or debonding is governed by principles of physical adsorption (physisorption) and thermodynamics. The large surface area afforded by the nanoporous aerogel (~1,000 m2/g) allows its storage performance to easily exceed capacities of high-pressure GH2 storage for an equivalent volume. With the integrated aerogel, subscale tests have shown that storage is increased by about 49% over a simple tank filled with GH2 at the same operating temperature and pressure. For LH2 conditions, the CFC is shown to operate at equivalent densities. For the techno-economic analysis (TEA), the source of hydrogen is compared between onsite steam methane reforming (SMR) and onsite solar photovoltaic (PV) panels providing power to electrolyzers to produce GH2. The TEA compares pure hydrogen burning in a combined cycle gas turbine (CCGT) to hydrogen fuel cells with an overall net power output of 650 MW. The SMR system uses natural gas as an input and includes a carbon capture and storage (CCS) system. The levelized cost of electricity is developed based on the capital cost and operating cost of the systems. Sensitivities are discussed around the cost of natural gas, ranging from 1.93 USD per MMBTU to 6.75 USD per MMBTU, and carbon dioxide disposal, ranging from 7 USD per tonne to 10 USD per tonne. For comparison to the conventional CCGT baseline, a baseload scenario is adopted with 85% capacity factor. The results of the study show that onsite hydrogen generation from SMR is about 1 to 3 USD per kg over the life of the plant and the PV hydrogen production produces at 4 to 5 USD per kg. The cost of storage for CFC is compared to other systems, including high-pressure GH2 and atmospheric LH2. The system is shown to provide the lowest costs for all these options at the grid scale, due to its higher capacity than high-pressure GH2 and ability to operate at 80K, receiving refrigeration from liquid nitrogen systems reducing capital and operating costs when compared LH2 storage systems. SMR is competitive with CCGT at the gas prices, both of which have lower LCOE than the PV system. When accounting for variability in gas prices, the PV and electrolyzer system is less sensitive to these changes and provides the lowest LCOE across the whole range.

08 HYDROGEN↗

Value of Geothermal Energy Storage for Supply-Side and Demand-Side Applications

This report presents the results of a study examining the value potential for geothermal energy storage (GES), a long-duration energy storage resource that stores thermal and/or geomechanical energy in the subsurface. GES could benefit the overall U.S. power system by temporally shifting electricity generation (supply-side) or meeting building heating and cooling load (demand-side). This report analyzes supply-side and demand-side opportunities independently because of differences in applications and models. Currently there is significant uncertainty about the development costs for GES, with only a limited number of demonstration plants for electric energy storage and building heating and cooling storage developments. In this report, we estimate the value of supply-side and demand-side GES to the bulk power system in the contiguous United States. Because of the significant uncertainty about GES development costs, this analysis does not consider GES deployment costs but instead focuses on the value of GES to the U.S. electricity system. The estimated values of GES provide reference points for economically competitive commercial cost targets. Supply-side GES is modeled as part of an enhanced geothermal system (EGS) generation plant in NREL's Regional Energy Deployment System (ReEDS) capacity expansion model (Ho et al. 2021). In contrast to conventional geothermal plants, which generate constant power, EGS plants have unique features that may allow for in-reservoir energy storage for flexible generation. Demand-side GES for heating and cooling, including seasonal hot and cold storage and short-duration heat pump storage, is incorporated into a price-taker model using Cambium electricity marginal cost projections. To establish an upper bound for the value of GES, analysis focused on favorable scenarios for storage with high generation from zero marginal cost, variable renewable energy resources. High penetrations of variable renewable energy generation can increase hourly electricity price variability, which increases the value of temporal energy arbitrage for storage technologies like GES.

15 GEOTHERMAL ENERGY↗

High-Fidelity and High-Performance Computational Simulations for Rapid Design Optimization of Sulfur Thermal Energy Storage

Industrial process heating (IPH) accounts for approximately 70% of US manufacturing energy use and is primarily produced by fossil fuel combustion. Approximately 1500 TWht (approximately 60%) of IPH demand is in the temperature range of 100-300. Industrial applications in this temperature range include drying, hydrothermal processing, thermal enhanced oil recovery, food and beverage, bioethanol production, etc. Cost-effective thermal energy storage (TES) that increases the utilization of waste and renewable heat (solar, geothermal, etc.) could provide significant energy savings and reliable heat sources, decrease emissions, and increase US manufacturing competitiveness through reductions in fuel consumption. TES development has historically been dominated by technologies suitable for deployment with concentrating solar power (CSP). State-of-the-art thermal storage deployed commercially with power tower CSP plants uses a 60%/40% NaNO3/KNO3 molten salt and operates between temperatures of approximately 280 degrees Celsius and 570 degrees Celsius using a two-tank configuration. However, these nitrate salts are unsuitable for operation outside of this temperature range due to a high freezing point of approximately 220 degrees Celsius, and limits on high-temperature salt stability and corrosion resistance of containment alloys. Other materials being investigated for TES include those based on: (1) sensible energy storage (various molten salt compositions, inert solid particles, rocks or pebble beds, sulfur, water, concrete, graphite, etc.), (2) latent energy storage in materials that undergo solid-liquid phase change at relevant temperatures (organic materials for low-temperature applications, inorganic salts and/or metals for high-temperature applications), or (3) thermochemical energy storage (hydrides, hydroxides, carbonates, metal oxides, etc.). The application temperature and challenges pertaining to storage material and/or containment cost, energy density, long-term thermal and cyclic stability, and charge/discharge heat transfer effectiveness drive material selection for a given IPH or electricity generation application. Sulfur is a cheap commodity at $80/ton compared to $1100 - 1300/ton for conventional salts. When using a metric of storage cost per kWh, sulfur costs around 2-3 $/kWh. Previous sulfur TES development focused on high temperature (>600 degrees) concentrated solar power applications with sulfur encapsulated in pipes and flow of gaseous HTF (air) in the shell side. However, for lower-temperature IPH applications in the range of approximately 100-300 degrees Celsius Element 16 adopted a compact and scalable TES design with molten sulfur in the shell and HTF pipes submerged in the molten sulfur bath. The low-cost molten sulfur TES for dispatchable IPH has deployment potential for broad applications. The spatial and temporal evolution of the HTF and sulfur temperature is critical to the TES system performance, and thus detailed modeling can improve understanding of the performance and facilitate design improvements. Using high performance computing and computational fluid dynamics (CFD) a low-cost molten sulfur thermal energy storage (TES) system for industrial process heating (IPH) applications was developed. The unique challenges in CFD modeling of sulfur TES are the sharp property changes of sulfur relevant to the working temperatures. Above 159, liquid sulfur undergoes polymerization, and the viscosity of sulfur rapidly increases by several orders of magnitude between 159 degrees Celsius and 188 degrees Celsius, followed by a decrease in viscosity beyond 188 degrees Celsius due to thermal bound dissociation. In addition, various concentrations of H2S impurities can also modify sulfur viscosity. This numerical challenge is especially relevant to transient simulation of the sulfur TES charging and discharging processes as the extreme property variations limit the applicability of traditional heat transfer correlations. Transient CFD simulations including the temperature-dependent sulfur properties and geometric complexity of the TES design were used to predict the effect of natural convection during charging and discharging on the heat transfer process, sulfur temperature uniformity, charge/discharge rates, and performance of the storage devices. The CFD model was validated with experimental results for a full charge and discharge cycle. The work will show 3D and 2D simulation comparisons aimed to facilitate rapid design iterations and a machine learning based design optimization approach.

CFD↗

Federated Access from DOE Labs to Distributed Storage in the EIC Era of Computing

The Electron Ion Collider (EIC) collaboration and future experiment is a unique scientific ecosystem within Nuclear Physics as the experiment starts right off as a crosscollaboration between Brookhaven National Lab (BNL) & Jefferson Lab (JLab). As a result, this muti-lab computing model tries at best to provide services accessible from anywhere by anyone who is part of the collaboration. While the computing model for the EIC is not finalized, it is anticipated that the computational and storage resources will be made accessible to a wide range of collaborators across the world. The use of federated ID seems to be a critical element to the strategy of providing such services, allowing seamless access to each lab site computing resources. However, providing Federated access to a Federated storage is not a trivial matter and has its share of technical challenges. In this contribution, we focus on the steps we took towards the deployment of a distributed object storage system that integrates with Amazon S3 and Federated ID. We will first cover for and explain the first stage storage solutions provided to the EIC during the detector design phase. Our initial test deployment consisted of Lustre storage using MinIO, hence providing an S3 interface. High Availability load balancers were added later to provide the initial scalability it lacked. Performance of that system will be shown. While this embryonic solution worked well, it had many limitations. Looking ahead, the Ceph object storage is considered a top-of-the-line solution in the storage community - since the Ceph Object Gateway is compatible with the Amazon S3 API out of the box, our next phase will use a native S3 storage. Our Ceph deployment will consist of erasure coded storage nodes to maximize storage potential along with multiple Ceph Object Gateways for redundant access. We will compare performance of our next stage implementations. Finally, we will present how to leverage OpenID Connect with the Ceph Object Gateway’s to enable Federated ID access. We hope this contribution will serve the community needs as we move forward with cross-lab collaborations and the need for Federated ID access to distributed compute facilities.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SIRIUS: Science-Driven Data Management for Multi-Tiered Storage

The data sets being generated by large applications on very large-scale systems are increasing in both size and complexity. At the same time, there are new ways available to store and access these data sets. The goal in this project is to develop software that applications can use to make use of new and existing storage technologies in more sophisticated ways. One challenge in scientific data management is handling ‘hot’ vs ‘cold’ data. Data that is hot is data that is needed (or will be needed soon) in order for the program to continue progressing, while cold data is either output (and so will not be need further during the life of the program) or will not be needed until significantly later in the program’s run. Hot data should be stored in a way that allows fast access. On most systems, economic factors lead to an inverse relationship between storage performance and storage capacity and so fast access storage is limited. This makes it important to correctly place hot and cold data and avoid cold data unnecessarily consuming precious resources. In this reporting period, we addressed this challenge in various ways and at various levels. Data management frameworks offer only limited control to applications in how data is stored. We have added software capabilities for seamlessly moving data between layers of the storage technology using promote and demote functions to existing software frameworks. This gives direct control to applications in deciding what priority data receives. Additionally, we integrated different storage layer management frameworks in order to allow data to be exchanged and moved between storage layers in a consistent way across the application. Further, applications are not always able to directly decide what storage level makes sense for a given piece of data without an understanding of the underlying storage technologies. Data storage frameworks are often positioned to make these sorts of decisions in service of the application. We have added machine-learning based capabilities to data staging frameworks in order to make intelligent decisions about where data should be stored given learning about patterns in previous usage of similar data.

97 MATHEMATICS AND COMPUTING↗

NETL’s Perspective on Storage Efficiency and CO2-SCREEN

Carbon capture and storage (CCS) is a process that captures carbon dioxide (CO2) by separating it from anthropogenic emissions sources before atmospheric release and storing that CO2 in deep geologic reservoirs. CCS is a powerful method for reducing anthropogenic CO2 which can ultimately diminish the effects of climate change. Prospective CO2 storage resource is the amount of carbon dioxide that can be stored in a given geologic formation typically given as a mass (e.g., metric tons). Obtaining accurate estimates of CO2 storage resources is necessary for governments and industries to make energy-related policy decisions. Researchers at the National Energy Technology Laboratory (NETL) under the Department of Energy (DOE) developed a methods and a tool [CO2-SCREEN (Storage prospeCtive Resource Estimation Excel aNalysis) to estimate prospective carbon storage resources for saline formations, unconventional shale formations, and residual oil zones. The methods and tool provide CO2 storage and efficiency outputs in the form of probability estimates (i.e. P10 and P90) as well as partitioning storage and efficiency estimates based on storage mechanism (total, free phase, sorbed phase, and dissolution phase). This presentation will focus on how storage efficiency is calculated based on numerical modeling efforts, how it’s applied in the storage methods and tool, and then highlighting needs for future development.

Hanson, Angela Goodman↗

Assessment of tank designs for hydrogen storage on heavy duty vehicles using metal hydrides

The objective of this project was to evaluate material-based hydrogen storage solutions as a replacement for high-pressure hydrogen gas or liquid hydrogen on Class 7 or 8 tractor fuel cell electric vehicles. The project focused on low-density main-group hydrides, a well-known class of materials for hydrogen storage. Prior research has considered metal amides as storage materials for light-duty vehicles but not for heavy-duty applications. The project established the basis for further development of storage systems of this type for heavy duty vehicles (HDV). Systems analysis of an HDV storage system comprised of a tank and associated balance of plant (piping, coolant tubes, burner) was performed to determine the usable hydrogen capacity. A composite storage material comprised of a metal hydride mixed with a high thermal-conductivity carbon is predicted to have a usable hydrogen volumetric capacity comparable to or exceeding that of 700 bar pressurized hydrogen gas. The gravimetric capacity of this material is also predicted to be competitive with pressurized gas, particularly if costly carbon fiber composite Type III or Type IV tanks are excluded. The storage system design parameters and material properties served as inputs to a second model that simulates fuel cell operation in conjunction with the storage system during an HDV drive cycle. The results show that sufficient hydrogen pressure can be produced to operate a Class 8 HDV, yielding a range of ~480 miles. These results are particularly relevant for high-impact regions, such as the South Coast Air Quality Management District, for which an economical vehicular hydrogen storage system with minimal impact on cargo capacity could accelerate adoption of heavy-duty fuel cell electric vehicles. An additional benefit is that knowledge generated by this project can assist in development of material-based storage for stationary applications such as microgrids and backup power for data centers.

08 HYDROGEN↗

NORTH DAKOTA CARBONSAFE PHASE III: SITE CHARACTERIZATION AND PERMITTING OF GEOLOGIC STORAGE OF CARBON DIOXIDE

The Energy & Environmental Research Center (EERC), in partnership with Minnkota Power Cooperative Inc. (Minnkota), SLB, and Computer Modelling Group Ltd. (CMG), supported wide-scale deployment of carbon capture and storage (CCS) as part of the U.S. Department of Energy (DOE) National Energy Technology Laboratory Carbon Storage Assurance Facility Enterprise (CarbonSAFE) Initiative Phase III. This phase included the acquisition, analysis, and development of information to fully characterize two storage complexes to demonstrate viable storage resources for commercial volumes of CO2 (defined by DOE as a minimum of 50 million tonnes [MMt] of CO2 within a 30-year period) (National Energy Technology Laboratory, 2024). Phase III also involved the preparation, submission, and approval of North Dakota underground injection control (UIC) Class VI storage facility permits (SFPs)—required precursors to applications for Class VI injection well permits. The presumed viability of commercial-scale CCS, situated adjacent to Minnkota’s Milton R. Young Station (MRYS), is validated by Minnkota’s continued pursuit of Project Tundra—an initiative to build the world’s largest lignite-based CCS project in central North Dakota (www.projecttundrand.com). Project Tundra comprises two scopes of work, Tundra Capture (installation of postcombustion CO2 capture at MRYS) and Tundra SGS (secure geologic storage). The efforts of North Dakota CarbonSAFE Phase III, Site Characterization and Permitting, supported Tundra SGS. Extensive site-specific characterization activities included a successful multimeasurement geophysical approach and drilling a stratigraphic test well (J-ROC 1, subsequently renamed Liberty-1) adjacent to MRYS. Core collection and analyses, downhole testing and fluid sampling, and geophysical logging were performed on J-ROC 1 and on a nearby stratigraphic test well (known as J-LOC 1), which was drilled, cored, and tested under a complementary project funded by the North Dakota Lignite Research Program. The injection tests performed on J-LOC 1 positively impacted the CarbonSAFE project, resulting in fewer proposed injection wells and significant construction, operations, and monitoring cost savings. The characterization data collected and analyses performed were integrated into geologic models, and successive numerical simulations were run to determine CO2 plume extent and subsurface pressure buildup associated with the planned CO2 injection rate of nearly 4 MMt per year. The latter doubles the CarbonSAFE Initiative goal with an estimated 100 MMt of CO2 stored in 20 years. Application of the U.S. Environmental Protection Agency’s (EPA’s) method for estimating the Class VI Rule area of review (AOR) to the overpressurized Broom Creek Formation inspired an alternative method of calculation, called risk-based AOR delineation. This peer-reviewed method was applied for the first time during the storage facility-permitting process. The two SFP applications submitted in 2021 successfully resulted in North Dakota Industrial Commission (NDIC) orders in 2022 authorizing the creation of the storage facility areas and amalgamation of pore space as well as establishing financial responsibility requirements. After approval of the SFPs, Minnkota filed in 2022 applications for permits to reenter the J-ROC 1 well and to drill two new wells—all with the intended purpose to become Class VI injection wells. To establish eligibility under the Internal Revenue Code for Section 45Q tax incentives, a monitoring, reporting, and verification (MRV) plan was prepared and submitted by Minnkota to EPA in 2022, resulting in the first such plan approved in North Dakota. Also in 2022, under the National Environmental Policy Act (NEPA), Minnkota prepared and submitted an environmental information volume (EIV) describing the proposed CCS project and associated potential environmental impacts. Based on the EIV, DOE determined that the proposed construction project required an environmental assessment, and Minnkota submitted the first draft in 2023 and a revised draft in 2024. Both submissions were followed by a public comment period. Subsequently, DOE issued a finding of no significant impact (FONSI) on September 13, 2024. A successful outreach program, strongly based in the production, presentation, and dissemination of informational material, fostered an environment to aid stakeholders in making informed decisions regarding the planned project. Opportunities for public input were provided at various steps along the way, including at county planning and zoning meetings, before and during the SFP administrative hearing, and during environmental assessment public comment periods. In addition, land/pore space owners and mineral owners had various points of contact, including granting access rights, securing pore space leasing, and mineral owner notifications. Based upon the successful storage facility permitting issued by NDIC, approval of the MRV plan by EPA, and receipt of a FONSI under the NEPA, Minnkota is continuing its pursuit of Project Tundra. In December 2023, the Office of Clean Energy Demonstrations under its Carbon Capture Demonstrations Projects Program announced funding for the capture system (Office of Clean Energy Demonstrations, 2023) and a proposal for CarbonSAFE Phase IV: Construction funding was submitted in March 2024 for the storage project. A go/no-go decision to proceed with construction and operations in the Broom Creek Formation is anticipated in 2024. References National Energy Technology Laboratory, CarbonSafe Initiative, https://netl.doe.gov/carbon-management/carbon-storage/carbonsafe (accessed August 2024). Office of Clean Energy Demonstrations, 2023, OCED selects three projects in CA, ND, and TX to reduce harmful carbon pollution, create new economic opportunities, and advance carbon reducing technologies, December, www.energy.gov/oced/articles/oced-selects-three-projects-ca-nd-and-tx-reduce-harmful-carbon-pollution-create-new (accessed August 2024).

Peck, Wesley↗

High temperature thermal energy storage, including a discussion of TES integrated into power plants

Storage temperatures of 260 C and above are considered. Basic considerations concerning energy thermal storage are discussed, taking into account general aspects of thermal energy storage, thermal energy storage integrated into power plants, thermal storage techniques and technical considerations, and economic considerations. A description of system concepts is provided, giving attention to a survey of proposed concepts, storage in unpressurized fluids, water storage in pressurized containers, the use of an underground lined cavern for water storage, a submerged thin insulated steel shell under the ocean containing pressurized water, gas passage through solid blocks, a rock bed with liquid heat transport fluid, hollow steel ingots, heat storage in concrete or sand, sand in a fluidized bed, sand poured over pipes, a thermal energy storage heat exchanger, pipes or spheres filled with phase change materials (PCM), macroencapsulated PCM with heat pipe concept for transport fluid, solid PCM removed from heat transfer pipes by moving scrapers, and the direct contact between PCM and transport fluid.

Turner, R. H.↗

Advanced onboard storage concepts for natural gas-fueled automotive vehicles

The evaluation of several advanced concepts for storing natural gas at reduced pressure is presented. The advanced concepts include adsorption on high surface area carbon, adsorption in high porosity zeolite, storage in clathration compounds, and storage by dissolution in liquid solvents. High surface area carbons with high packing density are the best low pressure storage mediums. A simple mathematical model is used to compare adsorption storage on a state of the art carbon with compression storage. The model indicates that a vehicle using adsorption storage of natural gas at 3.6 MPa will have 36 percent of the range, on the EPA city cycle, of a vehicle operating on a compression storage system having the same physical size and a peak storage pressure of 21 MPa. Preliminary experiments and current literature suggest that the storage capacity of state of the art carbons could be improved by as much as 50 percent, and that adsorption systems having a capacity equal to compression storage at 14 MPa are possible without exceeding a maximum pressure of 3.6 MPa.

Remick, R. J.↗

Fuel Cell Systems for First Lunar Outpost: Reactant Storage Options

A Lunar Surface Power Working Group was formed to review candidate systems for providing power to the first lunar outpost habitat. The working group concluded that the most attractive candidate included a photovoltaic unit, a fuel cell, a regenerator to recycle the reactants, and storage of oxygen and hydrogen gases. Most of the volume (97 percent) and weight (64 percent) are taken up by the reactants and their storage tank. The large volume is difficult to accommodate, and therefore, the working group explored ways of reducing the volume. An alternative approach to providing separate high pressure storage tanks is to use two of the descent stage propellant storage tanks, which would have to be wrapped with graphite fibers to increase their pressure capability. This saves 90 percent of the volume required for storage of fuel cell reactants. Another approach is to use the descent storage propellant tanks for storage of the fuel cell reactants as cryogenic liquids, but his requires a gas liquefication system, increases the solar array by 40 percent, and increases the heat rejection rate by 170 percent compared with storage of reactants as high pressure gases. For a high power system (greater than 20 kW) the larger energy storage requirements would probably favor the cryogenic storage option.

Nelson, P. A.↗

Terrestrial Energy Storage SPS Systems

Terrestrial energy storage systems for the SSP system were evaluated that could maintain the 1.2 GW power level during periods of brief outages from the solar powered satellite (SPS). Short-term outages of ten minutes and long-term outages up to four hours have been identified as "typical" cases where the ground-based energy storage system would be required to supply power to the grid. These brief interruptions in transmission could result from performing maintenance on the solar power satellite or from safety considerations necessitating the power beam be turned off. For example, one situation would be to allow for the safe passage of airplanes through the space occupied by the beam. Under these conditions, the energy storage system needs to be capable of storing 200 MW-hrs and 4.8 GW-hrs, respectively. The types of energy storage systems to be considered include compressed air energy storage, inertial energy storage, electrochemical energy storage, superconducting magnetic energy storage, and pumped hydro energy storage. For each of these technologies, the state-of-the-art in terms of energy and power densities were identified as well as the potential for scaling to the size systems required by the SSP system. Other issues addressed included the performance, life expectancy, cost, and necessary infrastructure and site locations for the various storage technologies.

Brandhorst, Henry W., Jr.↗

Storage Characteristics of Lithium Ion Cells

Lithium ion cells are being developed under the NASA/Air Force Consortium for the upcoming aerospace missions. First among these missions are the Mars 2001 Lander and Mars 2003 Lander and Rover missions. Apart from the usual needs of high specific energy, energy density and long cycle life, a critical performance characteristic for the Mars missions is low temperature performance. The batteries need to perform well at -20 C, with at least 70% of the rated capacity realizable at moderate discharge rates (C/5). Several modifications have been made to the lithium ion chemistry, mainly with respect to the electrolyte, both at JPL' and elsewhere to achieve this. Another key requirement for the battery is its storageability during pre-cruise and cruise periods. For the Mars programs, the cruise period is relatively short, about 12 months, compared to the Outer Planets missions (3-8 years). Yet, the initial results of our storage studies reveal that the cells do sustain noticeable permanent degradation under certain storage conditions, typically of 10% over two months duration at ambient temperatures, attributed to impedance buildup. The build up of the cell impedance or the decay in the cell capacity is affected by various storage parameters, i.e., storage temperature, storage duration, storage mode (open circuit, on buss or cycling at low rates) and state of charge. Our preliminary studies indicate that low storage temperatures and states of charge are preferable. In some cases, we have observed permanent capacity losses of approx. 10% over eight-week storage at 40 C, compared to approx. 0-2% at O C. Also, we are attempting to determine the impact of cell chemistry and design upon the storageability of Li ion cells.

Ratnakumar, B. V.↗

Nano-enhanced solid-state hydrogen storage: Balancing discovery and pragmatism for future energy solutions

Nanomaterials have revolutionized the battery industry by enhancing energy storage capacities and charging speeds, and their application in hydrogen (H 2 ) storage likewise holds strong potential, though with distinct challenges and mechanisms. H 2 is a crucial future zero-carbon energy vector given its high gravimetric energy density, which far exceeds that of liquid hydrocarbons. However, its low volumetric energy density in gaseous form currently requires storage under high pressure or at low temperature. This review critically examines the current and prospective landscapes of solid-state H 2 storage technologies, with a focus on pragmatic integration of advanced materials such as metal-organic frameworks (MOFs), magnesium-based hybrids, and novel sorbents into future energy networks. These materials, enhanced by nanotechnology, could significantly improve the efficiency and capacity of H 2 storage systems by optimizing H 2 adsorption at the nanoscale and improving the kinetics of H 2 uptake and release. We discuss various H 2 storage mechanisms—physisorption, chemisorption, and the Kubas interaction—analyzing their impact on the energy efficiency and scalability of storage solutions. The review also addresses the potential of “smart MOFs”, single-atom catalyst-doped metal hydrides, MXenes and entropy-driven alloys to enhance the performance and broaden the application range of H 2 storage systems, stressing the need for innovative materials and system integration to satisfy future energy demands. High-throughput screening, combined with machine learning algorithms, is noted as a promising approach to identify patterns and predict the behavior of novel materials under various conditions, significantly reducing the time and cost associated with experimental trials. In closing, we discuss the increasing involvement of various companies in solid-state H 2 storage, particularly in prototype vehicles, from a techno-economic perspective. In conclusion, this forward-looking perspective underscores the necessity for ongoing material innovation and system optimization to meet the stringent energy demands and ambitious sustainability targets increasingly in demand.

25 ENERGY STORAGE↗

Performance evaluation of a dynamic wall integrated with active insulation and thermal energy storage systems

Thermal energy storage systems in buildings can store cooling/heating energy during non-peak load hours or when renewable energy sources are available for later use when demanded. Using the building envelope as a thermal battery can help to shave the peak load, reduce the burden in electric grids, and enhance the occupant's thermal comfort. Sensible energy storage on wall systems such as thermally activated building systems can provide an active thermal storage strategy. However, most of the stored energy is used through passive means directed by the thermal lag, which can impede the on-demand release of the stored energy. Integrating active insulation systems with building thermal storage systems can increase the flexibility of charging and discharging time and duration. In this study, a wall system equipped with an active insulation system and thermally activated storage system was designed, and its performance on active cooling energy contribution was studied. The performances of energy storage (charging), release (discharging) of the thermal energy storage energy, and the active insulation system were studied separately and together as an integrated system. Results showed that the thermal properties of the thermal energy storage core material and the pipe spacing of both embedded pipes in the thermal energy storage and hydronic pipes used in the active insulation system affected the wall performance the most out of all the tested wall system parameters. During discharging, the heat flux into the wall was as high as 81.92 W/m 2 . This active insulation system's dynamic R-value varied between less than 1ft 2 •°F•h/BTU (0.18 m 2 •K/W) to 98% of the equally thick foam insulation's R-value.

25 ENERGY STORAGE↗

Off-design operation and performance of pumped thermal energy storage

In this article, we describe off-design models and control strategies for a Pumped Thermal Energy Storage (PTES) system that uses liquid thermal energy storage: specifically molten salt for hot storage and methanol for cold storage. Off-design conditions arise when load-following, or due to variations in storage tank temperatures or ambient temperatures. We propose a control strategy that uses inventory control to manage the mass flow rate in the thermodynamic cycles, which facilitates load following. We also propose a control strategy for the storage fluid mass flow rates, which are varied to ensure the molten salt is maintained at its design temperature. This maximizes efficiency and minimizes problems with salt freezing or degradation. The cold storage fluid mass flow rate is varied so that the cold tanks have the same state-of-charge as the hot tanks. This leads to variations in cold fluid temperature, but these variations are shown to be acceptably small (e.g. 7.5% increase), and this control method is shown to be simpler and more efficient than an alternative strategy where tanks become unbalanced. The ambient temperature and storage tank temperatures are moved ±50 °C from the design values and the impact on power, duration, and tank temperatures is quantified. Results demonstrate that the proposed control strategy is stable and self-correcting - that is, storage temperatures converge on stable values after two-to-three charge-discharge cycles. When inputs return to design values, the system returns to its design point after two charge-discharge cycles. We also demonstrate that inventory control enables delivery of the target power output even when off-design conditions exist that would normally reduce the power output.

25 ENERGY STORAGE↗

Injection data analysis using material balance time for CO 2 storage capacity estimation in deep closed saline aquifers

Estimating the ultimate storage capacity of deep saline aquifers is important to address the formation potential to store the envisioned large volumes of CO 2 . Injection data (i.e. injection rate, bottomhole pressure, and cumulative injected volume of CO 2 ) are routinely recorded during storage operations. These data contain valuable information on the subsurface (e.g. the reservoir pore volume and the formation storage capacity) that can be extracted. In this paper, we present a two-step graphical technique to infer the pore volume and the ultimate storage capacity of closed saline aquifers by analyzing the available injection data. First, the pore volume is inferred through adapting the concept of the material balance time. Material balance time is an approximate superposition time function developed to interpret production data from oil and gas wells operating at variable pressure/rate conditions during the boundary-dominated flow period. Using material balance techniques, the ultimate storage capacity is then estimated through linear extrapolation of the average pressure trend to the maximum allowable pressure the formation can withstand. The average pressure is not available in practice, but is can be obtained from the injection data. Two approaches are presented in this study to calculate the average pressure; namely the rigorous and the approximate approaches. Unlike the rigorous approach, the approximate approach does not require a prior knowledge of some reservoir properties (e.g. relative permeability, absolute permeability, formation porosity and thickness) to calculate the average pressure. To investigate its potential and reliability in analyzing CO 2 injection data, the proposed technique is applied to four synthetic cases representing different well operating conditions. Results indicate that the approximate approach consistently overestimates the actual (simulated) storage capacity as compared to the rigorous approach. The agreement - between the inferred and the simulated reservoir pore volume, and between the analytical and numerical estimates of storage capacity - validates the potential application of the technique to CO 2 storage in closed saline aquifers. The technique is further substantiated through application to a field data set utilized from a commercial-scale geological storage (CGS) project. Finally, field data interpretation shows that the proposed technique can be utilized to identify the degree of hydraulic continuity and reservoir compartmentalization within a target formation by interpreting the corresponding pressure and rate responses.

02 PETROLEUM↗

Policy and Regulatory Environment for Utility-Scale Energy Storage: Bangladesh

Bangladesh has experienced significant economic growth and poverty reduction over the past several decades. Recognizing the central role electricity plays in economic development, the Government of Bangladesh (GOB) has established policies to accelerate the growth of the electric power sector. The Bangladesh power grid is transforming into one marked by declining reliance on domestic natural gas reserves and oil-based rental power plants, increasing renewable energy contribution, and shifting demand patterns. The GOB is now reconsidering its prior plans to increase the share of coal capacity in the generation mix to meet demand, shifting its focus instead to electricity imports from neighboring countries, nuclear generation, liquified natural gas imports, and domestic renewable resources such as wind and solar. However, investments in the transmission and distribution system, as well as ancillary services, have not kept pace with investments in generation resources over the past decade. Thus, Bangladesh electricity consumers still experience outages and poor power quality despite adequate installed capacity. On the demand side, population growth and industrialization have fueled steady growth in electricity consumption as efforts to expand access to electricity enabled near-universal electricity access by mid-2020. The combined changes in the mix of generation resources and patterns of electricity demand present new challenges and opportunities in operating and maintaining a reliable power system. Energy storage has the potential to help meet these challenges and accelerate Bangladesh’s energy transition. Declining costs for some energy storage technologies make them increasingly cost-effective solutions to provide a wide range of grid services. Previous analyses of energy storage in the region have identified several potential applications for storage at the bulk system level, including energy arbitrage, ancillary services, and transmission network support. The potential for storage to meet these needs depends on many factors, including physical characteristics of the power system and the policy and regulatory environments in which these energy storage assets would operate. This report applies an Energy Storage Readiness Assessment the National Renewable Energy Laboratory developed for policy makers and regulators to identify priority areas of focus as they continue to develop the appropriate suite of policies, programs, and regulations to enable storage deployment. This assessment uses a simple evaluation scheme to identify the barriers and opportunities for utility-scale energy storage within Bangladesh’s policy and regulatory environment.

24 POWER TRANSMISSION AND DISTRIBUTION↗