Search NASA⌕ Search

SEARCH · Search NASA

Results for “Stream temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Polarization and wavelength diversities of Gulf Stream fronts imaged by AIRSAR

During the 1990 Gulf Stream Experiment, NASA/JPL AIRSAR imaged the north edge of the Gulf Stream near the coast of Virginia. Simultaneous in-situ measurements of currents, temperatures, salinities, etc. were made for several crossings of the north edge by the R/V Cape Henlopen. Measurements identified two fronts with shearing and converging flows. The polarimetric SAR images from the fronts showed two bright linear features. One of them corresponds to the temperature front, which separated the warm Gulf Stream water to the south from a cool, freshwater filament to the north. The other line, located about 8 km north of the temperature front, is believed to correspond to the velocity front between the filament and the slope water. At these fronts, wave-current interactions produced narrow bands of steep and breaking waves manifesting higher radar returns in polarimetric SAR images. In general, our AIRSAR imagery shows that the signal-to-clutter ratio of radar cross sections for the temperature front is higher than that of the velocity front. In this paper, we study the polarization and wavelength diversities of radar response of these two fronts using the P-, L-, and C-Band Polarimetric SAR data. The north-south flight path of the AIRSAR crossed the temperature front several times and provided valuable data for analysis. Three individual passes are investigated. We found that for the temperature front, the cross-pol (HV) responses are much higher than co-pol responses (VV and HH), and that P-Band HV has the highest signal to clutter ratio. For the velocity front, the ratio is the strongest in P-Band VV, and it is indistinguishable for all polarizations in C-Band. The radar cross sections for all three polarization (HH, HV, and VV) and for all three bands are modelled using an ocean wave model and a composite Bragg scattering model. In our initial investigations, the theoretical model agrees qualitatively with the AIRSAR observations.

Lee, J. S.↗

Similar solutions for the compressible laminar boundary layer with heat transfer and pressure gradient

Stewartson's transformation is applied to the laminar compressible boundary-layer equations and the requirement of similarity is introduced, resulting in a set of ordinary nonlinear differential equations previously quoted by Stewartson, but unsolved. The requirements of the system are Prandtl number of 1.0, linear viscosity-temperature relation across the boundary layer, an isothermal surface, and the particular distributions of free-stream velocity consistent with similar solutions. This system admits axial pressure gradients of arbitrary magnitude, heat flux normal to the surface, and arbitrary Mach numbers. The system of differential equations is transformed to integral system, with the velocity ratio as the independent variable. For this system, solutions are found by digital computation for pressure gradients varying from that causing separation to the infinitely favorable gradient and for wall temperatures from absolute zero to twice the free-stream stagnation temperature. Some solutions for separated flows are also presented.

Cohen, Clarence B↗

Electrochemical Nutrient Recovery for the Food–Energy–Water Nexus at Municipal Wastewater Facilities: Multivariate Analyses of Seasonal Sampling and Reactor Performance

Digester-equipped municipal wastewater facilities generate recycle streams with high nutrient loads that increase energy consumption and can cause environmental pollution. The reduction of these loads through electrochemical nutrient recovery (ENR) could enhance the food–energy–water nexus by producing fertilizer (struvite). This study investigated the recovery process through a 1 year sampling of recycle streams and the implementation of nutrient recovery. Time series analyses showed that P (as orthophosphate) concentration was time-variant in digester effluent streams, while N (as ammonia) concentration was time-variant in only the aerobic system. Furthermore, these two nutrient concentrations did not correlate in any of the recycle streams. Subsequent multivariate screening analyses identified anode type, NH 4 + concentration, cathodic potential, P concentration, and temperature as most significant for ENR. Finally, the optimum conditions of cathodic potential, anode area-to-volume ratio, and temperature applied to a real recycle stream resulted in 95% P recovery with 0.03 kWh/kg P. This energy consumption is significantly lower than process energy for conventional P fertilizers (1.1 kWh/kg P) and chemical recovery processes at scale (1.7–12.9 kWh/kg P). Overall, this study recommended specific process controls for nutrient recovery, expanded the variables evaluated for ENR, and demonstrated the ability to significantly impact energy demand associated with P-based fertilizers.

36 MATERIALS SCIENCE↗

Flow and temperature fields following injection of a jet normal to a cross stream

The interaction of a jet entering into a freestream normal to the main flow direction has been studied with particular attention directed to visualization of the large-scale flow interactions and to measurement of the film-cooling performance. Large eddies are apparent downstream of the entering jet even at moderate blowing rate (defined as the ratio of the mass velocity of the jet to the mass velocity of the freestream). At higher blowing rate, there is only intermittent contact between the mass from the jet and the downstream wall. The film cooling downstream from a single normal jet yields a lower centerline effectiveness compared to an inclined jet through a greater lateral spreading. The greater spreading provides a more uniform effectiveness across the span of the downstream wall, in particular at large blowing rate.

Goldstein, R. J.↗

Controlling Heat-Exchanger Outlet Temperature

Nearly constant temperature maintained regardless of fluid flow. Mixing heated and unheated fluids ensures constant temperature at outlet of heat exchanger. Main stream fluid heated, and bypass fluid unheated. Devised to maintain constant-temperature output under varying flow rates. Used with fluids other than liquid oxygen - water for example.

Daniels, C. M.↗

Synoptic Gulf Stream velocity profiles through simultaneous inversion of hydrographic and acoustic Doppler data

Data from a shipborne acoustic profiling device have been combined with conductivity, temperature, depth/O2 sections across the Gulf Stream to form estimates of the absolute flow fields. The procedure for the combination was a form of inverse method. The results suggest that at the time of the observations (June 1982) the net Gulf Stream transport off Hatteras was 107 + or - 11 Sv and that across a section near 72.5 W it had increased to 125 + or - 6 Sv. The transport of the deep western boundary current was 9 + or - 3 Sv. For comparison purposes an inversion was done using the hydrographic/O2 data alone as in previously published results and obtained qualitative agreement with the combined inversion. Inversion of the acoustic measurements alone, when corrected for instrument biases, leaves unacceptably large mass transport residuals in the deep water.

Joyce, T. M.↗

Hourly observations of the jet stream - Wind shear, Richardson number and pilot reports of turbulence

Results are presented of observations of the jet stream made on the basis of over 400 hr of wind and temperature data taken during two prolonged jet stream passages above western and central Pennsylvania during mid-November 1986 and mid-January 1987. Wind profilers are found to be far better suited for the detailed examination of jet stream structure than are weather balloons. The combination of good vertical resolution with not previously obtained temporal resolution reveals structural details not seen before. Development of probability forecasts of turbulence based on wind profiler-derived shear values appears possible. A good correlation between pilot reports and turbulence and wind shear is found.

Syrett, William J.↗

Pressure Measurement in Supersonic Air Flow by Differential Absorptive Laser-Induced Thermal Acoustics

Nonintrusive, off-body flow barometry in Mach-2 airflow has been demonstrated in a large-scale supersonic wind tunnel using seedless laser-induced thermal acoustics (LITA). The static pressure of the gas flow is determined with a novel differential absorption measurement of the ultrasonic sound produced by the LITA pump process. Simultaneously, stream-wise velocity and static gas temperature of the same spatially-resolved sample volume were measured with this nonresonant time-averaged LITA technique. Mach number, temperature and pressure have 0.2%, 0.4%, and 4% rms agreement, respectively, in comparison with known free-stream conditions.

Hart, Roger C.↗

Description and calibration of the Langley Hypersonic CF4 tunnel: A facility for simulating low gamma flow as occurs for a real gas

The Langley Hypersonic CF4 Tunnel is a Mach 6 facility which simulates an important aspect of dissociative real-gas phenomena associated with the reentry of blunt vehicles, i.e., the decrease in the ratio of specific heats (gamma) that occurs within the shock layer of the vehicle. A general description of this facility is presented along with a discussion of the basic components, instrumentation, and operating procedure. Pitot-pressure surveys were made at the nozzle exit and downstream of the exit for reservoir temperatures from 1020 to 1495 R and reservoir pressures from 1000 to 2550 psia. A uniform test core having a diameter of circa 11 in. (0.55 times the nozzle-exit diameter) exists at the maximum value of reservoir pressure and temperature. The corresponding free-stream Mach number is 5.9, the unit Reynolds number is 4 x 10 to the 5th power per foot, the ratio of specific heats immediately behind a normal shock is 1.10, and the normal-shock density ratio is 12.6. When the facility is operated at reservoir temperatures below 1440 R, irregularities occur in the pitot-pressure profile within a small region about the nozzle centerline. These variations in pitot pressure indicate the existence of flow distrubances originating in the upstream region of the nozzle. This necessitates testing models off centerline in the uniform flow between the centerline region and either the nozzle boundary layer or the lip shock originating at the nozzle exit. Samples of data obtained in this facility with various models are presented to illustrate the effect of gamma on flow conditions about the model and the importance of knowing the magnitude of this effect.

Midden, Raymond E.↗

Hourly wind profiler observations of the jet stream - Wind shear and pilot reports of turbulence

Hourly wind profiler observations of the jet stream are reported on the basis of over 400 hr of wind and temperature data taken during two prolonged jet stream passages over western and central Pennsylvania during mid-November 1986 and mid-January 1987. The mean wind speed profile with error bars for the 79 hr that the Crown radar was determined to be 'under' the jet stream is shown. A mean speed of 83 m/s for the period was found. A plot of wind shear for the hours of interest is given. Typically, the shear was at a maximum from 3 to 4 km below the level of maximum wind. Thus, an aircraft would have to fly through potentially rough air to reach the fuel savings and relative smoothness of flight at the jet stream level. A good correlation between pilot reports of turbulence and wind shear was found.

Syrett, William J.↗

Modeling the Gulf Stream System: How Far from Reality?

Analyses of a primitive equation ocean model simulation of the Atlantic Ocean circulation at 1/6 deg horizontal resolution are presented with a focus on the Gulf Stream region. Among many successful features of this simulation, this letter describes the Gulf Stream separation from the coast of North America near Cape Hatteras, meandering of the Gulf Stream between Cape Hatteras and the Grand Banks, and the vertical structure of temperature and velocity associated with the Gulf Stream. These results demonstrate significant improvement in modeling the Gulf Stream system using basin- to global scale ocean general circulation models. Possible reasons responsible for the realistic Gulf Stream simulation are discussed, contrasting the major differences between the present model configuration and those of previous eddy resolving studies.

Choa, Yi↗

Variable stream control engine concept for advanced supersonic aircraft: Features and benefits

The Variable Stream Control Engine is studied for advanced supersonic cruise aircraft. Significant environmental and performance improvements relative to first generation supersonic turbojet engines are cited. Two separate flow streams, each with independent burner and nozzle systems are incorporated within the engine. By unique control of the exhaust temperatures and velocities in two coannular streams, significant reduction in jet noise is obtained.

Howlett, R. A.↗

NOAA's oceanography studies under the Earth Resources Survey Program

Some results are presented of Earth Resources Survey Program studies conducted on: (1) Defining and developing methods of suppressing system noise and cloud contamination in satellite measurements of infrared window radiation. (2) Relating sea surface temperature patterns in the Gulf Stream and Gulf of Mexico to associated thermal front structure with aid of infrared data from Nimbus or ITOS. (3) Testing the feasibility of mapping sea surface roughness and low level wind speed over tropical oceans by means of ATS imagery in sun glitter zones. (4) Microwave radiometer measurements from aircraft and their usefulness and limitations for all-weather mapping of surface roughness, sea ice conditions, and possible surface temperature. (5) Evaluation of scanning radiometer data from ITOS for purposes of mapping snow and ice conditions.

Mcclain, E. P.↗

A correlation of mixing noise from coannular jets with inverted flow profiles

Data are correlated for jet mixing noise from coannular jets with inverted flow velocity profiles. The acoustic performance of coannular jets is compared to the performance of a hypothetical single jet with the same total mass flow, thrust, and total enthalpy flow as the coannular jet. The study shows that coannular jets with velocity ratios greater than 1.2 produce less noise than their corresponding equivalent tests and that optimum noise reduction of coannular jets in the data set occurs within a range of equivalent velocities between 500 and 700 meters per second and velocity ratios between 1.6 and 2.3. The maximum sound power reduction is found to be about 4 decibels. Directivity indices and a special set of spectral curves were developed to describe the characteristic double peak spectra of coannular jet noise. The temperature ratio between the inner and outer streams was not found to be important in this acoustic correlation. However, the mean temperature effect was included in the computations of sound pressure levels.

Pao, S. P.↗

In-Line Capacitance Sensor for Real-Time Water Absorption Measurements

A capacitance/dielectric sensor was designed, constructed, and used to measure in real time the in-situ water concentration in a desiccant water bed. Measurements were carried out with two experimental setups: (1) passing nitrogen through a humidity generator and allowing the gas stream to become saturated at a measured temperature and pressure, and (2) injecting water via a syringe pump into a nitrogen stream. Both water vapor generating devices were attached to a downstream vertically-mounted water capture bed filled with 19.5 g of Moisture Gone desiccant. The sensor consisted of two electrodes: (1) a 1/8" dia stainless steel rod placed in the middle of the bed and (2) the outer shell of the stainless steel bed concentric with the rod. All phases of the water capture process (background, heating, absorption, desorption, and cooling) were monitored with capacitance. The measured capacitance was found to vary linearly with the water content in the bed at frequencies above 100 kHz indicating dipolar motion dominated the signal; below this frequency, ionic motion caused nonlinearities in the water concentration/capacitance relationship. The desiccant exhibited a dielectric relaxation whose activation energy was lowered upon addition of water indicating either a less hindered rotational motion or crystal reorientation.

Nurge, Mark A.↗

Effects of flow separation and cove leakage on pressure and heat-transfer distributions along a wing-cove-elevon configuration at Mach 6.9

External and internal pressure and cold-wall heating-rate distributions were obtained in hypersonic flow on a full-scale heat-sink representation of the space shuttle orbiter wing-elevon-cove configuration in an effort to define effects of flow separation on cove aerothermal environment as a function of cove seal leak area, ramp angle, and free-stream unit Reynolds number. Average free-stream Mach number from all tests was 6.9; average total temperature from all tests was 3360 R; free-stream dynamic pressure ranged from about 2 to 9 psi; and wing angle of attack was 5 deg (flow compression). For transitional and turbulent flow separation, increasing cove leakage progressively increased heating rates in the cove. When ingested mass flow was sufficient to force large reductions in extent of separation, increasing cove leakage reduced heating rates in the cove to those for laminar attached flow. Cove heating-rate distributions calculated with a method that assumed laminar developing channel flow agreed with experimentally obtained distributions within root-mean-square differences that varied between 11 and 36 percent where cove walls were parallel for leak areas of 50 and 100 percent.

Deveikis, W. D.↗

Analysis of unsteady thermal boundary layers

The velocity and temperature distribution in an unsteady thermal boundary layer is analyzed by an approximate integral method. The case of a flat plate in a free stream having small harmonic velocity oscillations about a steady mean value is treated in detail. The resulting velocity profiles agree with the available experimental data. These profiles are used to predict the thermal convection when the plate and the stream are at constant but different temperature levels. The flow oscillations cause harmonic temperature oscillations plus a small steady feedback effect which reduces the mean heat transfer to the plate. The amount of decrease is represented by a single coefficient, which is presented graphically.

Miller, R. W.↗

A three-dimensional model of co-rotating streams in the solar wind. 2: Hydrodynamic streams

Theoretical aspects of corotating solar wind dynamics on a global scale are explored by means of numerical simulations executed with a nonlinear, inviscid, adiabatic, single-fluid, three-dimensional (3-D) hydrodynamic formulation. A simple, hypothetical 3-D stream structure is defined on a source surface located at 35 solar radius and carefully documents its evolution to 1 AU under the influence of solar rotation. By manipulating the structure of this prototype configuration at the source surface, it is possible to elucidate the factors most strongly affecting stream evolution: (1) the intrinsic correlations among density, temperature, and velocity existing near the source; (2) the amplitude of the stream; (3) the longitudinal breadth of the stream; (4) the latitudinal breadth of the stream; and (5) the heliographic latitude of the centroid of the stream.

Pizzo, V. J.↗