Search NASA⌕ Search

SEARCH · Search NASA

Results for “Substations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Deep Convolutional Neural Networks for Distribution System Fault Classification

Faults happen very frequently in distribution systems. Identifying fault types and phases are of critical importance for outage management, fault location, and service restoration. However, this task becomes very challenging due to measurement scarcity in distribution systems. This paper is among the first few that applies deep learning techniques in distribution system fault classification. Specifically, a sequential Convolutional Neural Network(CNN)-based classifier is developed to identify fault buses and phases. The input to the CNN is the steady-state voltage and current data measured at substations. The fault identification is modeled as a multi-label classification problem. Training data under various fault scenarios are obtained in OpenDSS and Gaussian noises are added to mimic measurement errors. A case study in IEEE 13-feeder test system is conducted with single and multiple bus faults scenarios. Numerical results demonstrate the high accuracy and fast computation of the proposed deep CNN-based fault classification.

Tian, Guanyu↗

Evaluation of Anomaly Detection for Wide-Area Protection Using Cyber Federation Testbed

Cyber physical security research for smart grid is currently one of the nation's top R&D priorities. The existing vulnerabilities in the legacy grid infrastructure make it particularly susceptible to countless cyber-attacks. There is a growing emphasis towards building interconnected, sophisticated federated testbeds to perform realistic experiments by allowing the integration of geographically-dispersed resources in the dynamic cyber-physical environment. In this paper, we present a cyber (network) based federation testbed to validate the performance of an anomaly detector in context of a Wide Area Protection (WAP) security. Specifically, we have utilized the resources available at the Iowa State University Power Cyber (ISU PCL) Laboratory to emulate the substation and local center networks; and the US Army Research Laboratory (ARL); to emulate the regional control center network. Initially, we describe a hardware-in-the loop based experimental setup for implementing data integrity attacks on an IEEE 39 bus system. We then perform network packet analysis focusing on latency and bandwidth as well as evaluate the performance of a decision tree based anomaly detector in measuring its ability to identify different attacks. Our experimental results reveal the computed wide area network latency; bandwidth requirement for minimum packet loss; and successful performance of the anomaly detector. Our studies also highlight the conceptual architecture necessary for developing the federated testbed, inspired by the NASPI network.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Data-Driven Load Diversity and Variability Modeling for Quasi-Static Time-Series Simulation on Distribution Feeders

This paper presents a data-driven load modeling methodology for distribution system quasi-static time-series (QSTS) simulation considering both diversity and variability characteristics of distribution loads. Based on our previous work in [1]-[2], a variability library and diversity library have been established based on the realistic high-resolution data collected from actual utility feeders. Given the load profile for the start-of-circuit load of a feeder, the loads on the feeder nodes can be modeled with both diversity and variability instead of being directly scaled from the substation load profile according to the distribution allocation factors. With diversified load models, the load-induced impact on the feeder operation characteristics, such as voltage ramp and regulator operations, can be better considered in QSTS simulation. The proposed modeling methodology has been tested on both the IEEE 123-bus feeder and an actual utility feeder model, and the simulation results have demonstrated the merits of deploying the proposed load modeling methodology.

24 POWER TRANSMISSION AND DISTRIBUTION↗

On the Use of Smart Meter Data to Estimate the Voltage Magnitude on the Primary Side of Distribution Service Transformers

This paper develops a novel method to estimate the voltage magnitude on the primary side of distribution service transformers. The proposed method relies exclusively on smart meters, and therefore it is fully data-driven. This is an important feature because electric utilities have detailed models of only the primary network - that is, the network between the distribution substation and the primary side of service transformers that are installed closer to end-customer sites. The network that connects the secondary side of service transformers to end-customer sites, referred to as the secondary network, is simply represented by a lumped load. For each secondary network, the proposed method uses data acquired from only 2 smart meters: the closest and the farthest-in the sense of electrical distance - from the service transformer. As a reference to this feature, the proposed method is named SM2Vp. To our knowledge, this is the first time a method is shown to provide actionable information for realtime operation and control of power distribution grids using only two smart meters per secondary network. This is important because utilities have experienced barriers in managing and using large data sets for real-time operation and control. SM2Vp is primarily intended to provide pseudo-measurements for distribution system state estimation, but it can also be used directly for voltage control schemes. The performance of SM2Vp is demonstrated by numerical simulations carried out on three secondary network synthetic models and by using field data provided by a utility partner serving customers in southwestern California. A maximum relative error of approximately 3.9% or less is observed for the primary voltage magnitude estimates in all numerical experiments.

distribution service transformer↗

Deep Reinforcement Learning for Distribution System Restoration Using Distributed Energy Resources and Tie-Switches

Distributed energy resources (DERs), such as solar PVs and energy storage, can be used to restore distribution system critical loads after the extreme weather events to increase grid resilience. However, coordinating multiple DERs together with tie-switches for multi-step restoration process under renewable uncertainty is challenging. This paper proposes a deep reinforcement learning to control discrete actions of switching on/off tie switches and DERs for critical load restoration. The restoration problem is first cast into the Markov decision process suitable for DRL. Then, the original soft actor critic (SAC) method for continuous actions has been extended to handle discrete and continuous actions. Numerical comparison results with other stochastic optimization-based approaches on the modified IEEE 33-bus system show that the proposed method can achieve fast critical load restoration in the presence of substation power outage while maintaining system voltage limit throughout the restoration process.

active distribution systems↗

Consensus-Based Approach for Active Power Control and Reserve Estimation in Distributed PV Systems

With the increased adoption of distributed energy resources (DER), they are expected to contribute to power system reliability services and enhance power system stability. This paper presents a distributed consensus control approach for the real-time active power reserve estimation and power management in distributed PV (photovoltaic) systems. The proposed method estimates the cumulative active power reserve from numerous PV generators using only the sparse communication network for a DER aggregator to provide active power regulation services. The real-time active power reserve estimation using the proposed approach can be used by DER aggregators to manage curtailment in distributed PV systems to maintain stipulated reserves and further to provide power system frequency regulation. Using the proposed approach, the DER aggregator only requires measurements at the feeder substation and it does not require information from individual DER units, thereby improving system resiliency. The proposed distributed consensus control method is validated on IEEE 123 testbed using PSCAD simulations.

active power reserve↗

An Iterative Bidirectional Gradient Boosting Algorithm for CVR Baseline Estimation

This paper presents a novel iterative, bidirectional, gradient boosting (bidirectional-GB) algorithm for estimating the baseline of the Conservation Voltage Reduction (CVR) program. We define the CVR baseline as the load profile during the CVR period if the substation voltage is not lowered. The proposed algorithm consists of two key steps: selection of similar days and iterative bidirectional-GB training. In the first step, preand post-event temperature profiles of the targeted CVR day are used to select similar days from historical non-CVR days. In the second step, the pre-event and post-event similar days are used to train two GBMs iteratively: a forward-GBM and a backwardGBM. After each iteration, the two generated CVR baselines are reconciled and only the first and the last points on the reconciled baseline are kept. The iteration repeats until all CVR baseline points are generated. We tested two gradient boosting methods (i.e., GBM and LighGBM) with two data resolutions (i.e., 15and 30-minute). The results demonstrate that both the accuracy and performance of the algorithm are satisfactory.

Lee, Han Pyo↗

Stochastic correlation analysis to rank the impact of intermittent wind generation on unreliability margins of power systems

Power systems are vulnerable to extreme contingencies (like an outage of a major generating substation or transmission line) that can cause significant generation and load loss and can lead to further cascading outages of other transmission facilities and generators in the system. Power systems operators take time-ahead actions (real time to day ahead) actions based on forecasted data as well as telemetry. However, there is a probability of extreme swings in wind generation that can push the power system that is already close to system boundaries into unreliable states. Increasing penetration on wind generation and uncertainties in short term forecast can move the system into operational states that can violate N-1 reliability criteria. While the power system planning accounts for worst case analyses to mitigate such emergencies, it is necessary to understand the spatial and temporal correlation of load buses with intermittent wind generation. The ranking of wind generators based on stochastic correlation to unreliability margins of load buses provides an insight of system vulnerabilities that can be corrected by appropriate emergency controls. A Monte-Carlo simulation of wind uncertainty forecast is performed to identify the probability distributions of unreliability margins. Ranking of wind generators is performed based on stochastic correlation analysis of the wind power generated and the load losses at the buses. This helps in not only identifying weak buses in the power system but also in identifying the vulnerable wind locations to plan for system reinforcements. Power system modeling and hybrid simulation to calculate unreliability margins are performed using DCAT and demonstrated on the 32-bus Nordic test system.

generators, wind forecasting, wind power generatio↗

Distribution-Connected PV's Response to Voltage Sags at Transmission-Scale

The ever increasing amount of residential- and commercial-scale distribution-connected PV generation being installed and operated on the U.S.'s electric power system necessitates the use of increased fidelity representative distribution system models for transmission stability studies in order to ensure the continued safe and reliable operation of the grid. This paper describes a distribution model-based analysis that determines the amount of distribution-connected PV that trips off-line for a given voltage sag seen at the distribution circuit's substation. Such sags are what could potentially be experienced over a wide area of an interconnection during a transmission-level line fault. The results of this analysis show that the voltage diversity of the distribution system does cause different amounts of PV generation to be lost for differing severity of voltage sags. The variation of the response is most directly a function of the loading of the distribution system. At low load levels the inversion of the circuit's voltage profile results in considerable differences in the aggregated response of distribution-connected PV Less variation is seen in the response to specific PV deployment scenarios, unless pushed to extremes, and in the total amount of PV penetration attained. A simplified version of the combined CMPLDW and PVD1 models is compared to the results from the model-based analysis. Furthermore, the parameters of the simplified model are tuned to better match the determined response. The resulting tuning parameters do not match the expected physical model of the distribution system and PV systems and thus may indicate that another modeling approach would be warranted.

14 SOLAR ENERGY↗

Estimating Spatial Distribution Impacts of Rooftops Solar PV on Dynamic Hosting Capacity Evaluation for a Real Distribution Feeder

This paper models the sensitivity of dynamic hosting capacity analysis to the spatial distribution of distributed PV scenarios, random, close and far from substation deployments, at various penetration levels on a real distribution feeder, in a quasi-static time series (QSTS) power flow simulation using high resolution time-aware metrics. These spatial distribution scenarios were chosen to capture a wide range of potential operation impacts of these deployments using a set of thermaland voltage-based metrics such as instantaneous violations and moving averages for both thermal and voltage constraints. This study uses actual load and PV data up-scaled from 1-hour time step to 1-minute resolution to fully characterize the interaction between the daily changes in load and PV output, and their impacts on distribution system operations.

distribution system↗

Planarization of Rough (100) GaAs Substrates via Growth by Hydride Vapor Phase Epitaxy

Wafer reuse techniques help offset the cost of III-V growth substrates by using a single wafer for multiple growths, but costly re-polishing after device removal limits the end benefit. In this work, we present planarization growth by hydride vapor-phase epitaxy (HVPE), a potentially low-cost growth technique, as a method of smoothing rough substrates for subsequent high-quality device growth without the need for polishing. First, we show there is a threshold for allowable substrate roughness without device degradation by comparing devices grown by organometallic vapor-phase epitaxy (OMVPE) on epi-ready polished and pre-polished substrates that did not have the final epi-ready polish. We then demonstrate successful smoothing with HVPE growth on substrates with different surface morphologies, with features ranging from general roughness to large facets. Initial devices grown by HVPE on a pre-polished substate showed no degradation compared to a control wafer, indicating that planarizing rough substrates through HVPE growth is a promising path toward being able to use rough substrates directly for growth, without costly polishing steps.

GaAs↗

The Challenges of Modeling Distributed Energy Resources (DERs) as Blackstart Resources and for Volt-VAR Optimality

Modeling, testing and instituting Distributed Energy Resources (DERs) as Blackstart Resoucrces presents several challenges due to the fundamental differences between traditional black start resources (e.g., large generators) versus DERs like solar PV systems with battery storage. This paper addresses some of these key challenges. These include intermittency of coordinating DERs to provide continuous power during a black start event, especially during extended periods of cloud cover or when battery energy storage is depleted. This paper additionally addresses the collapsing voltage and stability control challenges specific to maintaining bulk power system stability during black start synchronization These physical and engineering limitations require careful engineering design, modeling and engineering to ensure that DERs can support critical loads and substations during black start events. A variety of additional challenges also exist. Additionally, there are challenges associated with feeder location and low voltage secondary system impacts on DER functions and settings. We compare typical functions and settings for DERs for power factor control and correction. We also demonstrate how voltag control via Volta-VAR power factor correction can be done

Mukherjee, Srijib↗

Qualification High Voltage Testing of Short Triax HTS Cables in the Laboratory

In order to qualify the electrical insulation design of future HTS cables installed in the electric grid, a number of high voltage qualification tests are generally performed in the laboratory on either single-phase model cables and/or actual three-phase cable samples. Prior to installation of the 200-m Triax HTS cable at the American Electric Power Bixby substation near Columbus, Ohio, in September, 2006, such tests were conducted on both single-phase model cables made at ORNL and tri-axial cable sections cut off from cable made on a production run. The three-phase tri-axial design provides some specific testing challenges since the ground shield and three phases are concentric about a central former with each phase separated by dielectric tape insulation immersed in liquid nitrogen. The samples were successfully tested and qualified for partial discharge inception, AC withstand, and lightning impulse where voltage is applied to one phase with the other phases grounded. In addition one of the phase pairs was tested for dc withstand as a ldquoworst caserdquo scenario to simulate the effect of VLF (Very Low Frequency) tests on the actual cable installed at the Bixby site. The model and prototype cables will be described and the high voltage test results summarized.

36 MATERIALS SCIENCE↗

Improving the Accuracy of Clustering Electric Utility Net Load Data using Dynamic Time Warping

Identifying patterns in electric utility net load data in a time-series format is very useful in preparing the operation for next day. Machine learning algorithms have been used in other domains and those concepts are applied in this paper on real-world net load measurement data. Clustering is the practice of grouping data with similar characteristics as determined by the distance measure. The K-means clustering algorithm is utilized here with actual electric utility data. The paper uses the standard distance measure, Euclidean distance (ED), and compares its performance against the dynamic time warping (DTW) measure. An actual case study with real data is presented, and DTW distance measure-based method observed to result better accuracy compared to the ED based method for substation net load measurements predominantly with residential customers.

clustering↗

Inertial Response of an Offshore Wind Power Plant with HVDC-VSC

This paper analyzes the inertial response of an offshore wind power plant (WPP) to provide ancillary services to the power system grid. The WPP is connected to a high-voltage direct-current voltage source converter HVDC-VSC to deliver the power to the onshore substation. The wind turbine generator (WTG) used is a doubly-fed induction generator (Type 3 WTG). In this paper we analyze a control method for the WTGs in an offshore WPP to support the grid and contribute ancillary services to the power system network. Detailed time domain simulations will be conducted to show the transient behavior of the inertial response of an offshore WPP.

17 WIND ENERGY↗

Voltage Control Devices on the IEEE 8500 Node Test Feeder

The IEEE Test Cases provide researchers with distribution system models that can be used to validate new analytic methods. The newest of these models is the 8500-node test feeder which contains multiple devices for voltage control. In addition to a substation regulator there are multiple inline regulators as well as capacitor banks. This paper will discuss the detail in which voltage control devises should be modeled when examining large distribution systems. This discussion will include issues associated with power flow analysis for a single time step as well as for time series analysis.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Volt-VAR Optimization on American Electric Power Feeders in Northeast Columbus

In 2007 American Electric Power launched the gridSMART® initiative with the goals of increasing efficiency of the electricity delivery system and improving service to the end-use customers. As part of the initiative, a coordinated Volt-VAR system was deployed on eleven distribution feeders at five substations in the Northeast Columbus Ohio Area. The goal of the coordinated Volt-VAR system was to decrease the amount of energy necessary to provide end-use customers with the same quality of service. The evaluation of the Volt-VAR system performance was conducted in two stages. The first stage was composed of simulation, analysis, and estimation, while the second stage was composed of analyzing collected field data. This panel paper will examine the analysis conducted in both stages and present the estimated improvements in system efficiency.

Schneider, Kevin P.↗

Netload Range Cost Curves for Coordinated Transmission-Distribution Planning Under DER Growth Uncertainty

The increasing penetration of distributed energy resources (DERs) requires better coordination between transmission and distribution (T&D) planning to ensure system security and cost efficiency. However, misaligned planning horizons, computational burdens, and privacy concerns hinder effective coordination, leading to either underutilized resources caused by overinvestments or reliability risks due to underinvestment. To address this challenge, we introduce netload range cost curves (NRCCs), a novel approach for managing long-term DER growth uncertainty through T&D coordination, while preserving existing data-sharing and regulatory structures. NRCCs provide pairs of (i) peak substation netload guarantees and (ii) corresponding distribution upgrade options and costs, enabling their seamless integration into transmission planning workflows. To compute NRCCs efficiently, we develop a transmission-aware distribution network planning (TADNP), which is subsequently integrated to an iterative computation procedure. These NRCCs are then embedded into an NRCC-informed transmission planning model to enable resource-efficient coordination. We illustrate our proposed approach with a case study based on realistic distribution and transmission systems in the San Francisco Bay Area, California. Our results indicate the possibility of dramatic savings in transmission investments by incorporating the proposed NRCC-integrated T&D coordination framework.

Li, Yujia↗