Search NASA⌕ Search

SEARCH · Search NASA

Results for “Suite”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

The petrology of the Apollo 12 ilmenite basalt suite

Mineral chemistry data and petrographic interpretations as well as fractionation modeling determined independently indicate that the bulk chemical variations in the ilmenite suite can be reconciled with differentiation within a single cooling unit. Olivine porphyritic basalts, medium-grained basalts with evolved compositions, and coarse-grained olivine cumulates are found in the suite. It is suggested that most of the chemical variation within the suite could result from fractionation of olivine equivalent to the composition of phenocrysts in vitrophyre 12008 which serves well as a parental magma for the other textural-chemical variants. The relative cooling rate sequence within all three textural-chemical subgroups was determined, and systematic correlations between the degree of olivine addition or subtraction and the relative cooling rate is indicated.

Dungan, M. A.↗

Causes of compositional variations within mare basalt suites

The short-range unmixing model, which explains compositional variations produced during crystallization of a single undifferentiated basalt flow, has been applied to the variations found within each of the suites of mare basalts. Based on this modelling, the following suites of mare basalts could represent random samples from single, undifferentiated lava flows: Apollo 11 A (high K), Apollo 15 olivine, Apollo 17 A-U, Apollo 17 B, Apollo 17 C. The short range unmixing model fails to account for variations within the Apollo 12 olivine-pigeonite group and Apollo 12 ilmenite group, which are well explained by fractional crystallization. The fact that the compositional variations within a suite of samples of unknown affinity can be explained in terms of short-range unmixing of a single lava does not mean that they are necessarily related in that way. It does, however, mean that independent evidence (stratigraphic, petrographic, isotropic, or age) is required to support arguments for the variations being caused by fraction crystallization or different magma batches.

Lindstrom, M. M.↗

The use of antigravity suits in the treatment of idiopathic orthostatic hypotension

Idiopathic orthostatic hypotension is an uncommon disease characterized by a drop in blood pressure when going from a recumbent to a standing position. Treatment by medication generally produces poor results. Three patients at the Royal Hospital in Oslo were treated with antigravity suits and all were able to maintain adequate blood pressures in the standing position. One patient improved dramatically and was able to take short walks while wearing the suit. The two other patients, however, felt that wearing the suits eventually became uncomfortable. This treatment represents a useful treatment alternative for intractable cases.

Landmark, K.↗

A seasonal verification of the Suits spectral reflectance model for wheat

Variables that characterize wheat canopies for the Suits Model and spectral bidirectional reflectance measurements in the 450 to 1350 nm interval were determined approximately weekly throughout the growing season for two cultivars of wheat that achieved maximum leaf area index of 5.3 and 10.8. The Suits Model plant variables were tabulated and experimental reflectance measurements were compared with the model predictions in the wavelength interval from 500 to 1150 nm at 50 nm increments for 17 measurement dates. The seasonal average coefficient of determination, r squared, was 0.88 between the Suits spectral bidirectional reflectance model and field-measured reflectance data. Poorest agreement was found very early and very late in the growing season, possibly due to low green plant biomass and incomplete ground cover.

Lemaster, E. W.↗

New Apparatus Tests Pressure-Suit Joints

New apparatus measures applied torque and angle-of-flexure in pressurized flexible joints, such as those found in diving suits and flight suits. Torque and flexure are permanently recorded on x-y plotter. Family of curves can be taken as function of suit pressure or other variables. Apparatus could also measure torque-versus-angle in mechanical linkages.

Vykukal, H. C.↗

Compatible atmospheres for a space suit, Space Station, and Shuttle based on physiological principles

Fundamental physiological principles have been invoked to design compatible environments for a space suit, Space Station and the spacecraft used to transport the astronauts from earth. These principles include the long-term memory of tissues for a bubble-provoking decompression, the intermittent nature of blood flow in the tight connective tissue(s) responsible for the bends whose incidence in aviators has been shown to be related to bubble volume by the Weibull distribution. In the overall design an astronaut breathing a mixture of 30 percent O2 in N2 for 4-5 h in a spacecraft at 11.9 psia can transfer to a Space Station filled with the same mix at 8.7 psia and, after a further 4-5 h, go EVA at any time without any oxygen prebreathing at any stage. The probable incidence of decompression sickness has been estimated as less than 0.5 percent using the present suit operating at 4.3 psia but the risk could be reduced to zero if the suit pressure were increased to 6.5 psia.

Hills, B. A.↗

Ballistic limit of 6061 T6 aluminum and threat to surface coatings for use with orbiting space station space suit materials

In recent years orbiting satellites, spent components, collisions and explosions have populated the near earth orbit with debris potentially more hazardous than the average meteoroid debris. This new debris has an average density of aluminum (2.78 g/cc) and an average encounter velocity of 10 km/sec. The space station will require many hours of work in this environment and there is concern over hazard to the assembly personnel. A proposed hard suit design utilizes 6061-T6 Aluminum for most of its exposed area. The aluminum surface will be treated for thermal and radiation control. The basic thickness of this suit will be on the order of 1.78 mm (0.070 inches). The selection of 6061-T6 Aluminum for space suits for use on the space station would appear to be worthwhile. The relatively ductile behavior of 6061-T6 aluminum is better than a choice of a more brittle material.

Fish, D.↗

Effect of STS space suit on astronaut dominant upper limb EVA work performance

The STS Space Suited and unsuited dominant upper limb performance was evaluated in order to quantify future EVA astronaut skeletal muscle upper limb performance expectations. Testing was performed with subjects standing in EVA STS foot restraints. Data was collected with a CYBEX Dynamometer enclosed in a waterproof container. Control data was taken in one g. During one g testing, weight of the Space Suit was relieved from the subject via an overhead crane with a special connection to the PLSS of the suit. Experimental data was acquired during simulated zero g, accomplished by neutral buoyancy in the Weightless Environment Training Facility. Unsuited subjects became neutrally buoyant via SCUBA BC vests. Actual zero g experimental data was collected during parabolic arc flights on board NASA's modified KC-135 aircraft. During all test conditions, subjects performed five EVA work tasks requiring dominant upper limb performance and ten individual joint articulation movements. Dynamometer velocities for each tested movement were 0 deg/sec, 30 or 60 deg/sec and 120 or 180 deg/sec, depending on the test, with three repetitions per test. Performance was measured in foot pounds of torque.

Greenisen, Michael C.↗

Results and applications of a space suit range-of-motion study

The range of motion of space suits has traditionally been described using limited 2-D mapping of limb, torso, or arm movements performed in front of an orthogonal grid. A new technique for recovering extra-vehicular (EVA) space suit range-of-motion data during underwater testing was described in a paper presented by the author at the 1988 conference. The new technique uses digitized data which is automatically acquired from video images of the subject. Three-dimensional trajectories are recovered from these data, and can be displayed using 2-D computer graphics. Results of using this technique for the current shuttle EVA suit during underwater simulated weightlessness testing are discussed. Application of the data for use in animating anthropometric computer models is highlighted.

Reinhardt, AL↗

Results and applications of a space suit range-of-motion study

The range of motion of space suits has traditionally been described using limited 2-D mapping of limb, torso, or arm movements performed in front of an orthogonal grid. A new technique for recovering extra-vehicular (EVA) space suit range-of-motion data during underwater testing was described in a paper presented by the author at the 1988 conference. The new technique uses digitized data which is automatically acquired from video images of the subject. Three-dimensional trajectories are recovered from these data, and can be displayed using 2-D computer graphics. Results of using this technique for the current shuttle EVA suit during underwater simulated weightlessness testing are discussed. Application of the data for use in animating anthropometric computer models is highlighted.

Reinhardt, AL↗

The physiology of spacecraft and space suit atmosphere selection

Factors which are considered in arriving at control values and control ranges of the parameters established for spacecraft and space suit environments include physiological, engineering, operational cost, and safety considerations. A number of physiological considerations are discussed, including hypoxia and hyperoxia, hypercapnia, temperature regulation, and decompression sickness. The impact of these considerations on space craft and space suit atmosphere selection is considered. The past experience in controlling these parameters in the U.S. and Soviet spacecraft and space suits and the associated physical responses are also reviewed. Physiological factors currently under investigation are discussed, including decompression sickness.

Waligora, J. M.↗

Comparative performance of a modified Space Shuttle Reentry Anti-G Suit (REAGS) with and without pressure socks

In a prior study, the Armstrong Laboratory (AL) demonstrated that +G(sub z) protection during simulated shuttle reentry could be improved with an extended coverage anti-G suit with pressure socks but no abdominal bladder (REAGS). In a subsequent study conducted at the NASA Johnson Space Center it was shown that REAGS had a down side which included restricted mobility (during simulated shuttle egress) and a larger boot size needed for the pressure socks. The present study was conducted using a modified REAGS to increase mobility during egress. The size of the crotch opening was increased, and the fabric covering the buttocks was replaced with more elastic material. Six healthy male members of the AL centrifuge panel served as subjects for the study. As in the earlier study, subjects received 20 to 35 mg of IV Lasix approximately 6 hours before being exposed to a simulated space shuttle reentry +G(sub z) profile on the AL centrifuge, which induced a mean weight loss of 2.8 percent, range 2.1 percent to 3.7 percent. The REAGS was inflated to 1.0 psig 10 minutes prior to G onset. The G-profile was identical to that used in the previous REAGS study. Physiologic parameters monitored were also the same, i.e., eye-level systolic blood pressure (ELBP) using the Finapres digital cuff technique and heart rate and rhythm. Subjective comments were obtained from questionnaires administered after the increased G exposure. Systolic ELBP was maintained at 60 mm Hg or above by pressurizing the anti-G suit in 0.5 psig increments up to a maximum pressure of 2.5 psig. There were no significant differences in mean G-suit pressure required to maintain systolic ELBP at 60 mm Hg or above between the REAGS worn with and without pressure socks. Maximum mean G-levels achieved during the GOR were also the same under both experimental conditions, i.e., 4.7 G with socks and 4.6 G without socks. These G-levels were essentially the same as recorded earlier with the unmodified REAGS. There were no significant differences in comfort rating during the G exposure assigned by subjects when they wore the modified REAGS with or without the pressure socks.

Krutz, R. W., Jr.↗

Chemical studies of H chondrites. 4: New data and comparison of Antarctic suites

We report data for the trace elements Au, Co, Sb, Ga, Rb, Ag, Se, Cs, Te, Zn, Cd, Bi, Ti, and In (ordered by putative volatility during nebular condensation and accretion) determined by neutron activation analysis in 13 H5 chondrites from Victoria Land and 20 H4-6 chondrites from Queen Maud Land, Antarctica. These and earlier results provide Antarctic sample suites of 34 chondrites from Victoria Land and 25 from Queen Maud Land. Treatment of data for the most volatile 10 elements (Rb to In) in these studies by multivariate statistical techniques more robust, as well as more conservative, than conventional linear discriminant analysis and logistic regression demonstrates that compositions differ at marginally significant levels. This difference cannot be explained by trivial (terrestrial) causes and becomes more significant, despite the smaller size of the database, when comparisons are limited to data from a single analyst and when all upper limits are eliminated from consideration. The Victoria Land and Queen Maud Land suites have different mean terrestrial ages (approximately 300 kyr and approximately 100 kyr, respectively) and age distributions, suggesting that a time-dependent variation of chondritic sources with different thermal histories is responsible. As a result, these two Antarctic suites are, on average, chemically distinguishable from each other. Since H chondrites serve as a paradigm for other meteorite classes, these results indicate that the near-Earth populations of planetary materials varied with time on the 10(exp 5)-year timescale.

Wolf, Stephen F.↗

NASA Research Announcement Phase 1 Report and Phase 2 Proposal for the Development of a Power Assisted Space Suit Glove Assembly

In July of 1996, ILC Dover was awarded Phase 1 of a contract for NASA to develop a prototype Power Assisted Space Suit glove to enhance the performance of astronauts during Extra-Vehicular Activity (EVA). This report summarizes the work performed to date on Phase 1, and details the work to be conducted on Phase 2 of the program. Phase 1 of the program consisted of research and review of related technical sources, concept brainstorming, baseline design development, modeling and analysis, component mock-up testing, and test data analysis. ILC worked in conjunction with the University of Maryland's Space Systems Laboratory (SSL) to develop the power assisted glove. Phase 2 activities will focus on the design maturation and the manufacture of a working prototype system. The prototype will be tested and evaluated in conjunction with existing space suit glove technology to determine the performance enhancement anticipated with the implementation of the power assisted joint technology in space suit gloves.

Cadogan, Dave↗

NASA Research Announcement Phase 2 Final Report for the Development of a Power Assisted Space Suit Glove

The main goal of this program was to develop an unobtrusive power-assisted EVA glove metacarpalphalangeal (MCP) joint that could provide the crew member with as close to nude body performance as possible, and to demonstrate the technology feasibility of power assisted space suit components in general. The MCP joint was selected due to its being representative of other space suit joints, such as the shoulder, hip and carpometacarpal joint, that would also greatly benefit from this technology. In order to meet this objective, a development team of highly skilled and experienced personnel was assembled. The team consisted of two main entities. The first was comprised of ILC's experienced EVA space suit glove designers, who had the responsibility of designing and fabricating a low torque MCP joint which would be compatible with power assisted technology. The second part of the team consisted of space robotics experts from the University of Maryland's Space Systems Laboratory. This team took on the responsibility of designing and building the robotics aspects of the power-assist system. Both parties addressed final system integration responsibilities.

Lingo, Robert↗

NASA CONNECT(TradeMark): Space Suit Science in the Classroom

NASA CONNECT's(TradeMark) program titled Functions and Statistics: Dressed for Space initially aired on Public Broadcasting Stations (PBS) nationwide on May 9, 2002. The program traces the evolution of past space suit technologies in the design of space suits for future flight. It serves as the stage to provide educators, parents, and students "space suit science" in the classroom.

Williams, William B.↗

The Dichotomous HED Meteorite Suite

The howardite, eucrite and diogenite (HED) clan is the largest suite of crustal rocks available from a differentiated asteroid. Attempts to unravel the petrogenetic history of the HED parent body have tacitly assumed that the suite is representative of the crust, and thus can be used to understand the differentiation history of the entire parent body. This assumption is a holdover from a time when we knew little about the HED parent body. Much has changed. Is this assumption still valid? HED Geochemistry: The HED suite is composed

Mittlefehldt, D. W.↗

Evaluation of Suited and Unsuited Human Functional Strength Using Multipurpose, Multiaxial Isokinetic Dynamometer

The objective of the planned summer research was to develop a procedure to determine the isokinetic functional strength of suited and unsuited participants in order to estimate the coefficient of micro-gravity suit on human strength. To accomplish this objective, the Anthropometry and Biomechanics Facility's Multipurpose, Multiaxial Isokinetic dynamometer (MMID) was used. Development of procedure involved selection and testing of seven routines to be tested on MMID. We conducted the related experiments and collected the data for 12 participants. In addition to the above objective, we developed a procedure to assess the fatiguing characteristics of suited and unsuited participants using EMG technique. We collected EMG data on 10 participants while performing a programmed routing on MMID. EMG data along with information on the exerted forces, effector speed, number of repetitions, and duration of each routine were recorded for further analysis. Finally, gathering and tabulation Of data for various human strengths for updating of MSIS (HSIS) strength requirement, which started in summer 2003, also continued.

Aghazadeh, Fred↗