Search NASA⌕ Search

SEARCH · Search NASA

Results for “TESTING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

High-Mileage Courier Fleet Vehicle Laboratory Battery Pack Testing

For one of each of the AVTA's plug-in hybrid electric vehicles, battery electric vehicles, and some hybrid electric vehicles tested in high-mileage courier fleets, the high-voltage traction battery packs were removed from the vehicle and tested at the beginning and end of fleet testing. For some vehicles, batteries also were tested at periodic intervals during fleet testing. Standard reference performance tests were conducted to characterize battery degradation over time. This dataset contains results from two or more rounds of battery tests for 21 distinct year/make/model vehicles (see reference ["INL Advanced Vehicle Testing Activity: On-road Logger and Laboratory Battery Pack Testing Vehicle List"](https://avt.inl.gov/sites/default/files/pdf/reports/DatasetVehicleList.pdf) for full list of vehicles). Each round of battery testing included the "Static Capacity Test" and the "Hybrid Pulse Power Characterization (HPPC) Test", conducted according to test procedures published in the United States Advanced Battery Consortium ["Battery Test Manual For Power-Assist Hybrid Electric Vehicles"](https://www.uscar.org/commands/files_download.php?files_id=57), ["Battery Test Manual For Plug-In Hybrid Electric Vehicles"](https://www.uscar.org/commands/files_download.php?files_id=168), and ["Electric Vehicle Battery Test Procedures Manual"](https://www.uscar.org/commands/files_download.php?files_id=5) prior to the time of testing. These tests were performed by Intertek Testing Services, North America. (This dataset will be shared by API; a small sample of the vehicle battery and test data has been extracted and is available for download while the API is being developed.)

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High-Mileage Courier Fleet Vehicle Laboratory Battery Pack Testing

For one of each of the AVTA's plug-in hybrid electric vehicles, battery electric vehicles, and some hybrid electric vehicles tested in high-mileage courier fleets, the high-voltage traction battery packs were removed from the vehicle and tested at the beginning and end of fleet testing. For some vehicles, batteries also were tested at periodic intervals during fleet testing. Standard reference performance tests were conducted to characterize battery degradation over time. This dataset contains results from two or more rounds of battery tests for 21 distinct year/make/model vehicles (see reference ["INL Advanced Vehicle Testing Activity: On-road Logger and Laboratory Battery Pack Testing Vehicle List"](https://avt.inl.gov/sites/default/files/pdf/reports/DatasetVehicleList.pdf) for full list of vehicles). Each round of battery testing included the "Static Capacity Test" and the "Hybrid Pulse Power Characterization (HPPC) Test", conducted according to test procedures published in the United States Advanced Battery Consortium ["Battery Test Manual For Power-Assist Hybrid Electric Vehicles"](https://www.uscar.org/commands/files_download.php?files_id=57), ["Battery Test Manual For Plug-In Hybrid Electric Vehicles"](https://www.uscar.org/commands/files_download.php?files_id=168), and ["Electric Vehicle Battery Test Procedures Manual"](https://www.uscar.org/commands/files_download.php?files_id=5) prior to the time of testing. These tests were performed by Intertek Testing Services, North America. This dataset is shared by API; a small sample of the vehicle battery and test data has been extracted and is also available for download.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

In-Sodium Testing of a Prototype Thermoacoustic Power Sensor for Sodium-Cooled Fast Reactors

The ultimate goal of this project is to develop and demonstrate a thermoacoustic power sensor (TAPS) for Sodium-Cooled Fast Reactors (SFRs), with potential application also envisioned to other nuclear technologies such as Lead-Cooled Fast Reactors (LFRs), Molten Salt Reactors (MSRs), in addition to Light Water Reactors (LWRs). The project was led by Westinghouse Electric Company, LLC (Westinghouse) and carried out in collaboration with Argonne National Laboratory (ANL) and the University of Pittsburgh. A TAPS is a passive (self-powered), non-invasive (wireless) sensor envisioned for measuring key parameters, such as local temperature and neutron flux, in a nuclear reactor core. The sensor generates pressure waves (i.e., sound waves) with a frequency and amplitude dependent upon nuclear operating conditions (coolant temperature or power changes). The acoustic waves are able to travel through the core and associated structures, and reach to the sensor network placed outside and/or inside of the reactor vessel. These sensors require a very small amount of power which, during loss of power events, can be provided, for example, by harvesting gamma radiation energy, thus resulting in a monitoring system that can function both during normal operation and during loss of power events. Westinghouse and the University of Pittsburgh designed and fabricated TAPS prototypes for Argonne National Laboratory (ANL) to carry out in-sodium testing to evaluate the effects of sodium on the TAPS and the performance of the TAPS technique in sodium. Argonne received a TAPS prototype from Westinghouse, and the prototype was modified such that it can be installed into a test vessel and function in sodium at elevated temperature without potentially leaking. A water mockup test apparatus was constructed to validate proper working of the prototype. An instrumentation and control (I&C) system, running on the National Instruments (NI) LabView platform, was developed to: 1) operate both the water mockup test and the in-sodium test facility; and 2) process and analyze the received acoustic signals from an array of accelerometers and the Argonne sodium-submersible high-temperature acoustic sensor. The prototype was successfully tested in a water bath at different temperatures. Water mockup tests demonstrated that the TAPS prototype is working properly and its resonance frequency changes linearly with the coolant (water) temperature. A TAPS test apparatus was constructed and integrated with the upgraded Under-Sodium Viewing (USV) sodium test facility. The integrated USV-TAPS sodium test facility has been operational. The TAPS prototype and a high-temperature sodium-submersible acoustic sensor (SSAS) developed by Argonne were both installed inside the TAPS test vessel. Being operated within argon cover gas under ambient conditions, the TAPS prototype demonstrated that it was functioning properly with a resonance frequency at 1407.2 Hz, which was successfully detected by the accelerometers mounted on the external wall of the vessel and the high-temperature SSAS installed inside the vessel. After successfully transferring sodium into the vessel, in-sodium tests of the prototype were conducted. Tests of the TAPS prototype demonstrated that the resonance frequency of the TAPS changes linearly with respect to the temperature difference between the interior of the TAPS and bulk sodium. The early tests showed that the TAPS prototype could not establish a continuous and consistent resonance in sodium. The resonance diminished before the prototype reached its operating temperature. A signal postprocessor was added to the DAQ module latterly to isolate interferences, enhance signal conditioning, improve peak detection, and generate resonance frequency versus temperature plots. After testing in molten sodium and immersion at higher temperature for several weeks, the TAPS prototype was able to establish a continuous resonance. Performance evaluation of the TAPS prototype was then conducted in sodium. The tests included the investigation of 1) the effects of the temperature difference between the TAPS and bulk sodium, 2) the effects of sodium flowrate; and 3) the performance of the different sensor-receiver systems positioned inside or outside the vessel. Results of a test demonstrated that, with limited sodium circulation, a continuous and consistent resonance of the TAPS prototype was established occasionally. The tests also demonstrated that, because of the nature of detection principles and mounting methods, the high temperature SSAS is more affected by acoustic noise, while accelerometers are more affected by vibrations, in the test environment. It is unknown why the TAPS prototype only occasionally established a continuous and consistent resonance when the TAPS temperature reached its operating temperature in molten sodium, and why it ultimately failed to resonate at all. A failure modes assessment was conducted and a few potential causes of failure were identified. Different post in-sodium tests were conducted to obtain additional information potentially relevant to the cause of the failure. Nondestructive evaluation techniques are suggested to examine the internal integrity as well as the gas mixture of the prototype. If they prove inconclusive, the prototype should be cut open to conduct a thorough inspection of its internal integrity and determine the state of the gas mixture.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Flow Sensor Test Article (F-STAr) (Design and Fabrication Status Report)

The Flow Sensor Test Article (F-STAr) is a test article currently under construction for the Mechanisms Engineering Test Loop (METL). F-STAr was designed to provide high sodium flowrate capabilities for sensor calibration, component testing, and fluid studies. Figure 1 shows two solid model views of the new test article. F-STAr includes a high-capacity pump that can provide a nominal flowrate of 120 GPM; a test section support structure that can accommodate a wide array of sub-test articles and their instrumentation; and finally, a heating and cooling system to aid in controlling the testing environment. Initially, F-STAr will be configured to test liquid metal flow sensors, specifically field shift sensors like the Eddy Current Flow Sensors (ECFS) based on the RDT C4-7T standard. To test these sensors, two test sections were designed that attempt to model Sodium Fast Reactor (SFR) outlet conditions. Figure 2 shows models of the “Full-Scaled Test Section” (FSTS) that represents a generic SFR fuel handling socket and a “Pseudo-Scaled Test Section” (PSTS) that represents a generic array of scaled fuel handling sockets. While F-STAr will be configured to test ECFS’s, it can also be outfitted to meet other experimental needs. For example, F-STAr could be setup with a test section that includes a fluidic diode or a component test investigating the performance of hydrodynamic bearings. Other test sections include studies of sodium thermal hydraulics like thermal striping. Overall, F-STAr is a flexible test article designed to accommodate many needs. This report will provide a status update on the design and construction of F-STAr. Manufacturing of all components has commenced, and several components have already been completed. These components include the pump and test section assembly stand. Other components, such as the heater, have been completed but were rejected due to the vendor not meeting the requirements of the purchase order. Lastly, the submersible flowmeter and main flange components are under construction, and their status will be reviewed in this report. Overall, most of the F-STAr components and parts will be completed by the end of September 2022.

42 ENGINEERING↗

Radiometric Testing of Germicidal UV Products, Round 1: UV-C Towers and Whole-Room Luminaires (CALiPER Summary Report)

This summary report analyzes the independently tested performance of 13 germicidal ultraviolet (GUV) products purchased between February and July 2022. A companion full report provides additional information and discussion of the tested products, test methods, and results. The products were of three different types: • Seven portable, consumer-oriented GUV towers designed to be placed on the floor or a desk of an unoccupied room to disinfect air and surfaces. Five of these products used LED sources and two products used low-pressure mercury (LPM) sources. • One non-portable GUV whole-room luminaire designed to be installed on a ceiling to disinfect air when a room is occupied. This product used an LED source. • Five non-portable GUV troffer or high-bay style whole-room luminaires designed to be installed in or suspended from a ceiling to disinfect air and surfaces when a room is unoccupied. All five used LPM sources. Radiometric and electrical performance was evaluated for all 13 products. Photobiological safety was also assessed for two of the products because their documentation included testable claims. The test results were compared across products and to manufacturer or vendor claims. The testing identified many issues related to the accuracy of reported GUV product performance. Claims were often untestable, contradictory, ambiguous, or used incorrect units and/or terminology. And when claims were testable, they often did not match test results. For example, three products that claimed to emit UV-C emitted only UV-A. These product claim issues were more numerous with consumer-oriented tower products, but problems with accurate performance claims were found across all products. The UV-C radiant efficiency of the products varied widely, even among similar products using the same source technologies. For example, the UV-C radiant efficiency of LPM products varied by greater than a factor of three for the same product type, indicating a large potential energy savings opportunity for products that are better designed for efficiency. LED products had orders-of-magnitude lower UV-C radiant efficiency than LPM products. Several testing challenges and limitations were identified. Most significant among these is the capability to accurately test and report the performance of larger GUV products. Integrating spheres require a specialized and costly coating to test UV, and the testing laboratory for this round of products had only a 20-inch diameter hemisphere with this capability. Only 2 of the 10 UV-C emitting products could be tested in this sphere. Goniometer testing had a different size limitation in that mirrors typically used to increase goniometer test distance to the far field are not reflective of UV and therefore could not be used to increase test distance. As a result, 7 of 13 products could not be tested far field. The implication is that electronic files of UV-C intensity data typically imported into design software for designing GUV applications may not be reliable for predicting irradiance at arbitrary far-field distances. It is currently unclear if these are industry-wide testing laboratory limitations, and what solutions may exist to address them. Specifiers and buyers of GUV products will need accurate performance claims and data to safely and effectively deploy GUV technology to reduce the transmission of diseases in buildings. This CALiPER GUV Round 1 report demonstrates the significant education and training that is needed for manufacturers and vendors to accurately test and report the performance of their GUV products. Further standards and guidelines are needed to improve test methods, address testing limitations, and improve reporting of product performance. Additionally, the wide range in UV-C radiant efficiency of GUV products means there is a large energy-savings opportunity for more energy efficient GUV products.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Guidance on the Use of Existing ASTM Polymer Testing Standards for ABS Parts Fabricated Using FFF

When evaluating the static mechanical performance of fused filament fabrication (FFF) polymers, researchers have conducted tensile testing using American Society for Testing Materials International (ASTM) D3039 rectangular test specimens and ASTM D638 Type I and Type IV dogbone test specimens. The choice of ASTM D638 versus ASTM D3039 test specimen geometry is usually based on the perceived susceptibility of the ASTM D638 test specimens to failure within the fillet radius. ASTM polymer and plastic tensile test standards define criteria for acceptably tested specimens as requiring failure inside the narrow length (i.e., ASTM D638) or outside of the grips (i.e., ASTM D3039) for the results to be considered acceptable. There has been limited published research regarding the selection of an ASTM test specimen geometry for FFF polymer materials. This study provides evidence-based guidance through the comparison of the mechanical performance and failure acceptance rates of ASTM D3039 and ASTM D638 test specimen geometries, fabricated using FFF acrylonitrile butadiene styrene (ABS). Here, the purpose of the study is to provide guidance on the use of existing ASTM polymer testing standards for additively manufactured polymers. Results indicate there is an inherent benefit to using ASTM D3039 over ASTM D638 Type I and Type IV test specimens for tensile testing. ASTM D3039 test specimens provide the most consistent failure within the test specimen’s gage length, which is attributed to the rectangular design of the test specimen. Results also indicated that, like traditionally manufactured polymer composites, there will be differences in the tensile test results (e.g., ultimate tensile strength, elastic modulus) based on the different cross-sectional areas of the test specimen geometries.

36 MATERIALS SCIENCE↗

FY2021 Improvements to the New CTH Code Verification & Validation Test Suite

Over the past few years, the CTH multiphysics hydrocode has overhauled its software quality and testing processes, implementing current best practices in software quality and building a robust V&V test suite comprised of traditional hydrocode verification problems, including ASC Tri-Lab Test Suite and Enhanced Tri-Lab Test Suite problems, as well as validation problems for some of CTH’s most frequently used equations of state, materials models, and other key capabilities. Substantial progress towards building this new test suite was made in FY19 and FY20. In FY21, the test suite has been expanded to include verification and validation tests of the Steinberg-Guinan-Lund (ST) viscoplastic model and the Johnson Cook (JFRAC) fracture model. Additionally, two new verification tests were added, covering hydrodynamics and high explosive (HE) modeling capabilities: the Kidder Gaussian density problem and the Escape of HE Products (EHEP) problem from the Tri-Lab Test Suite. This report discusses each of these test problems in detail. Verification test results are compared to analytic solutions. Validation test results are compared to experimental data. Wherever possible, convergence or mesh refinement studies are included. Additionally, while implementing the Kidder verification problem, a bug was identified that affects the use of tables to initialize pressure or density in 1D or 2D calculations. A brief discussion of the bug and its fix is included. CTH demonstrates good performance overall on the new test suite problems. Simulation results showed good agreement with analytic solutions for the Kidder problem, with convergence rates ranging between 1.8 and sub-linear, and relatively good agreement for the EHEP problem, though convergence rates for pressure and density were nearly 0. The ST and JFRAC strain rate loading verification tests show good agreement with analytic solutions. Likewise, CTH simulation results show good agreement with experimental validation data, including Taylor rod impact testing, for the materials tested. Future V&V work will focus on adding 2D and 3D versions of existing verification tests as well as adding validation tests of other frequently used capabilities such as other fracture models.

42 ENGINEERING↗

Extended Bandwidth Spread Spectrum Time Domain Reflectometry Cable Test for Thermal Aging, Low Resistance Fault, and Water Detection

In 2022, researchers at Pacific Northwest National Laboratory (PNNL) used the Accelerated and Real-Time Environmental Nodal Assessment (ARENA) cable and motor test bed to characterize spread spectrum time domain reflectometry (SSTDR) and compare the responses of an SSTDR instrument to those of a frequency domain reflectometry (FDR) instrument. Results showed both techniques could detect and locate cable anomalies such as phase-to-phase low resistance and shorts, thermal insulation damage, mechanical insulation damage, and the presence or absence of water in some conditions. The SSTDR tests used a commercial instrument provided by LiveWire Innovations Inc. This commercial instrument performed tests at 6, 12, 24, and 48 MHz bandwidth. The results of these tests were compared to FDR tests where bandwidths could be extended up to 1.3 GHz, although the best responses for cable tests were from 100 to 500 MHz. Lower bandwidth signals can propagate better along the cable while higher bandwidths have higher resolution for impedance change reflections allowing more precise indication of location and separation of anomalies. The 2022 research found that FDR responses were clearer than SSTDR and speculated that a higher bandwidth SSTDR could more successfully detect and locate cable anomalies. One advantage of the SSTDR system investigated was that it was designed for energized online use up to 1,000 volts, which may be a significant advantage for nuclear power plant use. The LiveWire SSTDR instrument is an established product in the rail and aircraft industry and updating the SSTDR hardware parameters is difficult to justify without more conclusive testing. Therefore, a software adjustable laboratory SSTDR instrument was developed by PNNL and was used to test extended bandwidth SSTDR cable tests. Within the ARENA test bed, 42 cable conditions were tested with the PNNL SSTDR, FDR, and the LiveWire SSTDR—each operating at four different bandwidths. Observations and conclusions regarding the relative performance of the three instruments over different bandwidths are note below. Responses of the PNNL SSTDR (at 50 MHz) and the LiveWire SSTDR (at 48 MHz) were similar. The PNNL SSTDR higher frequency bandwidths behaved as expected showing sharper peaks and higher noise. This validated the PNNL SSTDR as a reasonable implementation of the SSTDR technology. Lower bandwidth SSTDR responses (particularly 6 and 12 MHz) may have increased value for use within longer cables but were not particularly effective at identifying anomalous cable behavior in the 100 ft cables tested here. The higher bandwidths of the PNNL SSTDR (50, 100, 200, and 400 MHz) did not provide substantially clearer cable reflectometry responses, but having the higher frequency responses available did add to the cable test evaluation. Strong responses to shorts and low impedance faults between phases were particularly evident in the higher bandwidth PNNL SSTDR and the FDR data. Measurements were repeatable, with similar responses obtained from a thermally aged cable for tests taken a month apart. Signal noise was affected in the unshielded cable by the local in-tray cable arrangement including proximity to metal edges and rungs of the cable tray. Foam isolation of the cable from the tray metal reduced in both FDR and SSTDR responses. Cable condition monitoring in nuclear power plants will likely benefit from both more informative off-line testing methods and from the development of on-line methods for continuous monitoring of cables in use. The LWRS-funded ARENA test bed was a valuable resource for this development and direct comparison of nuclear electrical cable condition monitoring technologies. Test results are targeted to guide industry advancement of testing and monitoring tools for cable aging management.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Integral LOCA fragmentation test on high-burnup fuel

Increasing the fuel burnup limit in light water reactors is sought to enhance fuel cycle economics and requires establishing a technical basis. Experimental observations of severe fuel fragmentation under loss-of-coolant-accident conditions at Halden and Studsvik had raised the need for additional considerations during the development of this technical basis. These test data suggested that the burnup threshold for high burnup fuel fragmentation may be influenced by pre-transient power. Additional loss-of-coolant-accident test data is therefore valuable to complement these tests and enhance the current state of understating. Oak Ridge National Lab has developed the Severe Accident Test Station capable of examining the oxidation kinetics and accident response of irradiated fuel and cladding materials for design basis accident and beyond design basis accident scenarios. Severe Accident Test Station provides various temperature profiles, steam, and the thermal shock conditions necessary for integral loss of coolant accident testing, defueled oxidation quench testing, and high-temperature beyond design basis accident testing. Severe Accident Test Station has been successfully installed and demonstrated in the Irradiated Fuels Examination Laboratory at Oak Ridge National Lab. Furthermore, descriptions of the in-cell re-fabrication capabilities and assembly of the loss-of-coolant-accident test train are provided. Installation of the Severe Accident Test Station system and in-cell re-fabrication restores United States capability to examine postulated and extended loss-of-coolant-accident conditions on spent fuel and cladding and provides a platform for evaluating advanced fuel and accident-tolerant fuel cladding concepts. Lastly, three in-cell integral loss-of-coolant-accident test were performed in the Severe Accident Test Station and compared to the Nuclear Regulatory Commission sponsored loss-of-coolant-accident test as well as the original loss-of-coolant-accident test performed at Argonne National Lab. Finally, the results of these tests as well as all publicly available integral loss-of-coolant-accident test were used to validate a threshold for high burnup fuel fragmentation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Corrosion Testing of Refractory inContact with Molten Glasses Designed for Waste Vitrification - VSL Touchpoint Matrix Glasses

It is known that the predictive life of the refractory ceramic liner of nuclear waste glass melters is conservative, as demonstrated by performance of these materials such as in the Defense Waste Processing Facility (DWPF). The motivation for this task is to maximize the useful life of the melters that will be operated at the Waste Treatment and Immobilization Plant (WTP), which will in turn minimize procurement and disposal costs and melter outage times, as well as to identify maximum loadings in the waste glass of those species that corrode melter components. This task was initiated jointly with Pacific Northwest National Laboratory (PNNL) with the objective to develop a methodology and model to enable more accurate prediction of refractory service life under prototypic conditions from laboratory-scale material corrosion tests. Refractory corrosion is generally reported as physical material loss, measured in units of distance (e.g., inch) or as physical material loss rate, measured in units of distance per time (e.g., inch/day). In post-operational melters, the refractory corrosion is measured directly, sometimes reported as corrosion depth. Crucible tests are used in the laboratory to accelerate the refractory corrosion to facilitate a meaningful measurement in a commensurate amount of time. Crucible tests are particularly useful in understanding refractory corrosion across a large glass composition space, where operational testing would be prohibitive. Some of the critical parameters that are known to influence refractory corrosion by molten glass in a crucible test are temperature, system redox, molten salt phases, glass chemistry, and test duration. The majority of data collected for Monofrax® K-3 (hereafter referred to as K-3) corrosion is from crucible tests, but a small amount comes directly from scaled and production melters. Crucible test data has been collected under varying conditions, whereas data collected from operational melters is relatively fewer and represents conditions specific to the melter campaign. The result is that the published data can be grouped and analyzed in multiple ways, not all of which are readily comparable. The Standard Test Method for Isothermal Corrosion Resistance of Refractories to Molten Glass (ASTM C621) outlines the general guidelines used across industry. That method describes a sealed, static test in which the surface area of the refractory coupon and the volume of glass are fixed. A significant portion of the crucible data pertaining to nuclear waste glasses has been collected in a modified configuration; the most notable differences being the surface area of the refractory coupon to volume of the glass and use of a method for bubbling the melt. To our knowledge, the influence of those parameters on the refractory corrosion has not been quantified. In this work, it was determined that static tests and bubbled tests would be performed. Savannah River National Laboratory (SRNL) was tasked with setting up and performing static testing while PNNL was tasked with setting up and performing bubbled testing. Initial activities were performed to establish laboratory methods that reproduce data comparable to existing data sets of K-3 refractory corrosion by low activity waste (LAW) and high-level waste (HLW) glass compositions. Later activities were focused on refining the test parameters to establish a standard test practice to be used between Laboratories and collecting additional data to be used in the enhanced waste glass model development. This document serves primarily to convey the refractory loss measurement results from corrosion testing of K-3 refractory with waste glass compositions developed for use in the WTP melters. The data will be used in the enhanced property/composition models being developed for waste glass vitrification and melter operations.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Radiometric Testing of Germicidal UV Products, Round 1: UV-C Towers and Whole-Room Luminaires (CALiPER Full Report)

This report analyzes the independently tested performance of 13 germicidal ultraviolet (GUV) products purchased between February and July 2022. The products were of three different types: • Seven portable, consumer-oriented GUV towers designed to be placed on the floor or a desk of an unoccupied room to disinfect air and surfaces. Five of these products used LED sources and two products used low-pressure mercury (LPM) sources. • One non-portable GUV whole-room luminaire designed to be installed on a ceiling to disinfect air when a room is occupied. This product used an LED source. • Five non-portable GUV troffer or high-bay style whole-room luminaires designed to be installed in or suspended from a ceiling to disinfect air and surfaces when a room is unoccupied. All five used LPM sources. Radiometric and electrical performance was evaluated for all 13 products. Photobiological safety was also assessed for two of the products because their documentation included testable claims. The test results were compared across products and to manufacturer or vendor claims. The testing identified many issues related to the accuracy of reported GUV product performance. Claims were often untestable, contradictory, ambiguous, or used incorrect units and/or terminology. And when claims were testable, they often did not match test results. For example, three products that claimed to emit UV-C emitted only UV-A. These product claim issues were more numerous with consumer-oriented tower products, but problems with accurate performance claims were found across all products. The UV-C radiant efficiency of the products varied widely, even among similar products using the same source technologies. For example, the UV-C radiant efficiency of LPM products varied by greater than a factor of three for the same product type, indicating a large potential energy savings opportunity for products that are better designed for efficiency. LED products had orders-of-magnitude lower UV-C radiant efficiency than LPM products. Several testing challenges and limitations were identified. Most significant among these is the capability to accurately test and report the performance of larger GUV products. Integrating spheres require a specialized and costly coating to test UV, and the testing laboratory for this round of products had only a 20-inch diameter hemisphere with this capability. Only 2 of the 10 UV-C emitting products could be tested in this sphere. Goniometer testing had a different size limitation in that mirrors typically used to increase goniometer test distance to the far field are not reflective of UV and therefore could not be used to increase test distance. As a result, 7 of 13 products could not be tested far field. The implication is that electronic files of UV-C intensity data typically imported into design software for designing GUV applications may not be reliable for predicting irradiance at arbitrary far-field distances. It is currently unclear if these are industry-wide testing laboratory limitations, and what solutions may exist to address them. Specifiers and buyers of GUV products will need accurate performance claims and data to safely and effectively deploy GUV technology to reduce the transmission of diseases in buildings. This CALiPER GUV Round 1 report demonstrates the significant education and training that is needed for manufacturers and vendors to accurately test and report the performance of their GUV products. Further standards and guidelines are needed to improve test methods, address testing limitations, and improve reporting of product performance. Additionally, the wide range in UV-C radiant efficiency of GUV products means there is a large energy-savings opportunity for more energy efficient GUV products.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Pilot-Scale Testing of an Integrated Circuit for the Extraction of Rare Earth Minerals and Elements from Coal and Coal Byproducts Using Advanced Separation Technologies

The primary objective of this project was to develop and demonstrate an integrated pilot-scale circuitry for recovering high-value rare earth elements (REEs) from coal and coal byproducts. The target performance was to produce a mixed REE product with content of at least two percent by weight on a dry mass basis in a cost-effective and environmentally benign manner. During the first nine months of the project period (Phase 2 Budget Period 2), pilot plant construction was completed including all field site startup activities such as permitting, engineering design, procurement/bidding, unit fabrication, site construction, equipment installation, module assembly, safety training, and circuit shakedown. During the remaining 21 months of project period (Phase 2 Budget Period 3), detailed field-testing activities were performed including feedstock sample collection and preparation, exploratory testing, circuit modification, detailed parametric study, and performance optimization. A detailed techno-economic analysis was performed based on the pilot plant testing findings which provided various scenarios for REE production. The project successfully accomplished the proposed target performance by producing mixed rare earth oxide (REO) with greater than 90% purity by weight in a continuous pilot scale operation from two distinctly different coarse refuse materials (i.e., West Kentucky No. 13 and Fire Clay coal seams), and at least three secondary sources (i.e., heap leach process and naturally formed acid mine drainage system). Project partners included the University of Kentucky, Virginia Tech, West Virginia University, Alliance Coal, Blackhawk Mining, Mineral Refining Company, and Mineral Separation Technologies. The pilot scale test facility was constructed at a former mining complex owned by Alliance Natural Resource Partners (Alliance Coal). The site was rehabilitated to accommodate the equipment installation, construction and fabrication, electrical power requirement, water line management and containment. The process units constructed and installed included X-ray sorting unit, crushing and grinding unit, physical separation unit, acid leaching unit, solvent extraction unit, and wastewater management unit. A rare earth mineral concentration unit was constructed as a standalone unit for flexible operation. A detailed environmental assessment and control plan was carried out to identify and quantify any potential impacts of the pilot-scale processing circuitry on the human and eco-system health and well-being. Corresponding mitigation strategies and control measures were provided. A conceptual flowsheet was developed to effectively remove thorium and uranium from high purity rare earth oxide mix or any potential radionuclide enriched stream. The two distinct feedstock materials were secured from the Blackhawk Mining Complex in eastern Kentucky where the Fire Clay (Hazard No. 4) seam is processed. The West Kentucky No. 13 (Baker) coarse refuse material was collected from an active process stream at an Alliance coal preparation plant located in western Kentucky. Characterization analysis indicated that both of feed materials generated from the two sources contained >300 ppm of TREEs on a dry whole mass basis which met the requirements for a qualified feed stock. The two feedstocks were further upgraded using a dual x-ray sorter to prepare the feed material for hydrometallurgical circuit. Thermal treatment on feed material prior to leaching was found to: 1) improve the leaching recovery of REEs, 2) increase the leaching kinetics, and 3) allow the leaching reaction to occur at lower acidity. Roasting at 600°C was selected as the pre-treatment condition for both West Kentucky No. 13 and Fire Clay coarse refuse material. Over 40% of leaching recovery was achieved by roasting West Kentucky No. 13 material having a top particle size of 3 mm in the pilot scale operation using 1.2M sulfuric acid leaching at 75OC. Initial pilot scale testing involved continuous operation of the pilot plant for 94 hours. The leaching unit was operated at solid-to-liquid ratio of 1 to 10 (w/v) using 0.5M sulfuric acid solution at a temperature of 75°C. The continuous solvent extraction circuit utilized rougher and cleaner units with DEHPA and TBP as the extractants. An innovative stripping circuit was developed to accumulate the REE concentration in the stripping solution to a level above 600 ppm. A bleed stream from the recycled strip solution was treated using oxalic acid precipitation which produced a high grade rare earth oxalate. The oxalate product was roasted to remove the oxalate which produced a rare earth oxide product having a purity greater 90%. Due to high concentrations of contaminant ions in the pregnant leach solution (PLS), a modified flowsheet was developed that involved pre-concentration of the REEs using multiple stages of precipitation and redissolution. The advantage of this process was improved removal of contamination before the downstream purification process and a significant cost reduction relative to the circuit that utilized the solvent extraction process. The modified circuitry included processes involving leaching, multistage precipitation, redissolution, and oxalate precipitation followed by roasting of the oxalate product. The circuit produced a mixed REO that was 92.96% pure from the initial test. A detailed parametric test plan was carried out which involved varying key parameters including solids feed rate, acid flowrate, acid concentration, multistage precipitation pH, redissolution pH, oxalate precipitation dosage and pH. The response variables included REE recovery, contaminant recovery, REO product grade and overall chemical consumption. Test results indicated that the acid-to-solid ratio is the key parameter to leaching efficiency as performance deteriorated with an increase in solids concentration. The optimal pH determined for REE precipitation and redissolution was 6.5 and 2.5, respectively. Additional tests were conducted to further improve the flowsheet. Recirculating a portion of the PLS to the feed of the leach tanks improved the leaching performance by lowering the pH of the leaching system and reducing the contamination recovery by shortening the residence time. Moreover, the removal of Al prior to REE precipitation significantly reduced the oxalic acid consumption in the oxalate precipitation circuit. The modified circuit produced over 90% grade REO by weight from both West Kentucky No. 13 and Fire Clay coarse refuse material in pilot scale continuous test programs. A case analysis model was developed to project the REE and major contaminants concentration in each PLS stream based on the leaching condition, pH cut point, and oxalic acid dosage. A correlation was established using empirical and semi-empirical models. Using the models, chemical consumption required for each stage was predicted based on the projected performance of the hydrometallurgy circuit. After identifying the optimum conditions, validation tests were carried out for the treatment of both West Kentucky No. 13 and Fire Clay coarse refuse materials in the pilot plant. The actual circuit performance and chemical consumptions were very close to the model predictions. Other than the two coarse refuse sources, several secondary feedstocks were also tested in the pilot plant facility. A “heap leach” system was constructed using the coarse refuse material generated from cleaning the West Kentucky No. 13 seam coal. Using the two stage SX rougher and cleaner circuit, a concentrate with a grade >90% REO was produced while recovering >97% of the REEs from the heap leach PLS. Naturally generated acid mine drainage (AMD) from West Kentucky No.13 mine was processed using the multistage precipitation circuit in the pilot plant in a test conducted for a period of 32 hours. The final grade of the mix RE oxide produced from the AMD was 90.84% with an overall circuit recovery of 64%. The primary source of REE was the selective precipitation steps involving iron and aluminum rejection. The hydrophobic-hydrophilic separation (HHS) process was proven to effectively recover coal from fine waste materials. For REM recovery, the HHS process was able to produce concentrates at grades of approximately 1.8% REE on an ash basis; however, recovery values were typically low, <10%, under the optimal conditions determined in the laboratory-scale testing. Staged testing of the pilot-scale HHS process for coal recovery and semi-continuous laboratory testing for REM testing showed that a total concentration ratio of more than 15x was observed for the REM recovery process. A circuit simulation package was developed for REE extraction and purification using a spreadsheet-based platform (Microsoft Excel). The REESim circuit simulation package is configured to track the mass and volume flows of components passing through a series of unit operations specified and configured by the user. The mass rates can then be utilized by the user to determine important performance indicators such as product mass yields, concentrate purity levels, element-by-element recoveries, and so forth. The techno-economic analysis showed that the roasting and leaching operations were the most expensive capital items, each contributing approximately 30% to the total capital cost. One notable contributor to the high production costs was the low REE recovery observed in the pilot scale trials. The product basket price was shown to have a strong influence on the economic viability of the scenarios, with the scandium price being the most significant influencer. Operating cost was shown to be extremely sensitive to REE recovery, REE feed grade, and leaching acid consumption. An analysis of ten different scenarios for a 500 t/h commercial operation revealed that three were economically favorable, producing internal rates of return varying from 27.7% to 33.1% and payback periods of 4 to 5 years. The project successfully developed and demonstrated a process to recover REEs from coal and coal byproducts in a pilot-plant operation which consistently produced over 90% grade REO mix from varies types of feedstocks. Commercialization analysis showed that the technology readiness level successfully achieved TRL 6 at the end of the project and demonstrated the need and the potential for scaling the process to further advance the technologies toward the goal of providing a domestic supply of REEs at a commercial scale.

01 COAL, LIGNITE, AND PEAT↗

Aquifer Hydraulic Testing and Characterization Plan for the Ringold Formation Unit A in the Hanford 200-ZP-1 Groundwater Operable Unit and Vicinity

This document presents a plan for testing and characterizing the hydraulic properties of the Ringold Formation, member of Wooded Island – unit A (Rwia) in the 200-ZP groundwater operable unit. The testing approach includes multiple field methods and associated analyses designed to investigate and understand aquifer hydraulic properties over a range of scales. Testing was designed to achieve specific testing objectives identified previously in the 200 ZP-1 Groundwater Operable Unit Ringold Formation Unit A Characterization Sampling and Analysis Plan (Ringold A SAP). The test plan provides necessary technical and operational detail for writing subsequent field test instruction documents specific to each testing location. Hydraulic characterization activities will proceed in a phased manner focusing on areas identified to have knowledge gaps and also critical for remedy modifications and/or selection. These activities are designed to minimize impact to pump-and-treat (P&T) operations and to use existing P&T injection and extraction wells as stress wells, and include use of the new Rwia monitoring wells installed for Ringold A SAP activities. ZP-1 hydraulic testing will include slug testing in new Rwia wells, shutdown-recovery tests in multiple Rwia and composite Ringold Formation member of Wooded Island – unit E (Rwie)-Rwia aquifer test locations, installation of new Automated Water Level Network stations in Rwia monitoring wells, characterization of P&T and barometric responses, identifying the vertical distribution of hydraulic conductivity in the Rwia and Rwie units using electromagnetic borehole flowmeter tests, and single-well tracer testing in select Rwia monitoring wells. Slug testing to be conducted during drilling is described under the Ringold A SAP. The remaining testing activities are to be conducted after well drilling and completion and are described in this test plan.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Generic characterization of electrical test benches for AC- and HVDC-connected wind power plants

The electrical test and assessment of wind turbines go hand in hand with standards and network connection requirements. In this paper, the generic structure of advanced electrical test benches, including grid emulator or controllable grid interface, wind torque emulator, and device under test, is proposed to harmonize state-of-the-art test sites. On the other hand, modern wind turbines are under development towards new features, concerning grid-forming, black-start, and frequency support capabilities as well as harmonic stability and control interaction considerations, to secure the robustness and stability of renewable-energy-based power systems. Therefore, it is necessary to develop new and revised test standards and methodologies to address the new features of wind turbines. This paper proposes a generic test structure within two main groups, including open-loop and closed-loop tests. The open-loop tests include the IEC 61400-21-1 standard tests as well as the additional proposed test options for the new capabilities of wind turbines, which replicate grid connection compliance tests using open-loop references for the grid emulator. In addition, the closed-loop tests evaluate the device under test as part of a virtual wind power plant and perform real-time simulations considering the grid dynamics. The closed-loop tests concern grid connection topologies consisting of AC and HVDC, as well as different electrical characteristics, including impedance, short-circuit ratio, inertia, and background harmonics. The proposed tests can be implemented using available advanced test benches by adjusting their control systems. The characteristics of a real power system can be emulated by a grid emulator coupled with real-time digital simulator systems through a high-bandwidth power-hardware-in-the-loop interface.

17 WIND ENERGY↗

Improvements to the New CTH Code Verification & Validation Test Suite (FY2020)

The CTH multiphysics hydrocode, which is used for a wide range of important calculations, has undertaken in recent years to overhaul its software quality and testing processes. A key part of this effort entailed building a new, robust V&V test suite made up of traditional hydrocode verification problems, such as those listed in the ASC Tri-Lab Test Suite and the Enhanced Tri-Lab Test Suite, as well as validation problems for some of CTHs most frequently used equations of state, materials models, and other key capabilities. Substantial progress towards this goal was made in FY19. In FY20, this test suite has been expanded to include verification and validation tests of the Sesame and JWL equation of state models as well as the Mader verification problem from the Tri-Lab Test Suite and the Blake verification problem - a linear elastic analog to the Hunter problem from the Enhanced Tri-Lab Test Suite. This report documents CTH performance on the new test suite problems. Verification test results are compared to analytic solutions and, for most tests, convergence results are presented. Validation test results are compared to experimental data and mesh refinement studies are included. CTH performs well overall on the new test problems. Convergence rates for the Blake and Mader problems are comparable to those for similar ASC codes. The JWL and Sesame verification tests show good agreement with analytic solutions. Likewise, CTH simulation results show good agreement with experimental validation data for the Sesame and JWL equations of state for the materials tested. Future V&V work will focus on adding tests for other key capabilities like fracture and high explosive models.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

International Benchmarking: A Global Perspective of Workplace Drug and Alcohol Testing

Workplace drug and alcohol testing has been widely implemented in diverse industries and is designed to detect the use of and deter the influence of legal and illegal substances that would impair the ability to perform work that has significant security and safety implications. Across the globe, patterns of drug and alcohol use and abuse and the regulations controlling drug and alcohol use vary by location (e.g., regions, countries, etc.). The prevalence of workplace drug and alcohol testing and protection of individuals’ rights in the workplace similarly tend to exhibit contextual differences. With the advancements in drug-testing technologies and the recent issuance of guidance for additional testing matrices (e.g., oral fluid, hair, etc.) by the U.S. Department of Health and Human Services, gaining a global perspective on the current state of drug and alcohol testing practices and regulations is important for leveraging such advancements to improve the effectiveness of drug and alcohol testing. The U.S. Nuclear Regulatory Commission (NRC) tasked the Pacific Northwest National Laboratory (PNNL) fitness for duty (FFD) team to conduct a benchmarking analysis of international drug and alcohol testing regulations and programs to identify similarities and differences in workplace testing programs and the basis for any differences. The benchmarking study focuses on a policy analysis and benchmarking metrics comparison among different countries and regions. The policy analysis includes the following three types of relevant international and national policies relevant to drug and alcohol testing in the nuclear industry: 1. National drug and alcohol policy 2. Workplace drug and alcohol testing 3. FFD regulations for Nuclear Power Plants The international drug and alcohol benchmarking metrics focusses on the use of blood, breath, urine, hair, and oral fluid in testing; drug and drug metabolite cutoff values; point-of-collection testing devices; roadside testing methodologies; innovations in drug testing; and the extent of availability of such data. Gaining an understanding of workplace drug and alcohol testing in other countries as well as information about new testing methods, matrices, tools, and technologies that other countries have adopted provides NRC with international comparative information regarding the technical basis for such programs and methods as it relates to the protection of worker and public health and safety.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Status Update for the Bearing Test Article Design Development – FY2025

Argonne National Laboratory’s (ANL) Mechanism Engineering Test Loop (METL) team has completed the design of a new Bearing Test Article (BTA) to test mechanical bearings for sodium fast reactor (SFR) mechanism applications. Recognition of the need for further bearing testing arose due to failure of rolling element bearings during testing of components for in-vessel fuel handling machines (FHMs) conducted at ANL in the METL facility. While the initial concept of the BTA arose from a need for bearing testing for FHM applications, the BTA design is configurable to test bearings of various sizes, types, and materials submerged in liquid sodium. Requirements for loading, shaft speed, temperature, and bearing size range were chosen based on requirements for SFR fuel handling. Modular components in the test bearing housings and shaft sleeves allow the design to accommodate a wide range of bearing sizes without modification to the larger assembly. Loading will be applied with screw jacks on the air side of the test article that will be adjusted to apply radial, thrust, or combined loading conditions. Applied force will be measured by load cells in-line with the loading mechanisms. In FY25 we have completed the design of the test article that will be fabricated and undergo testing at the METL facility. Drawing packages for the fabrication of the test article have been drafted and are being reviewed to add part tolerances and we have started ordering off-the-shelf components. The report will summarize the development of the Bearing Test Article design starting with an overview of the entire test article, then a more detailed examination of the bearing test section, loading mechanisms, test article ports and seals, and support structures, including analysis that went into significant design choices.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Use of nucleic acid amplification testing for rapid detection of Mycobacterium tuberculosis complex among U.S. tuberculosis patients from 2011–2017

Background: Nucleic acid amplification (NAA) tests rapidly detect Mycobacterium tuberculosis complex directly from clinical specimens, providing valuable results for those evaluated for tuberculosis. Methods: We analyzed characteristics of cases with NAA testing performed, compared cases with positive and negative NAA test results, and calculated turnaround time and time to treatment for all verified cases reported to the National Tuberculosis Surveillance System in the United States during 2011–2017. Results: Among 67082 verified tuberculosis cases with NAA testing information, 30820 (45.9%) were reported as not having an NAA test performed; the proportion without NAA testing declined annually, from 60.5% in 2011 to 33.6% in 2017. Of 67082 verified cases, 27912 (41.6%) had positive, 8215 (12.2%) had negative, and 135 (0.2%) had indeterminate NAA test results. Among the 33937 cases with an acid-fast bacilli (AFB) smear-positive result, 24093 (70.9%) had an NAA test performed; 11490 of the 30244 (38.0%) with an AFB smear-negative result had an NAA test performed. Although sputum was the most common specimen type tested, 79.8% (7023/8804) of nonsputum specimen types had a positive NAA test result. Overall, 63.7% of cases with laboratory testing had NAA test results reported <6 days following specimen collection; for 13891 cases not yet on treatment, median time to treatment after the laboratory report date was 2 days. Conclusions: Our analyses demonstrate increased NAA test utilization between 2011 and 2017. However, a large proportion of cases did not have an NAA test performed, reflecting challenges in broader uptake, suggesting an opportunity to expand use of this diagnostic methodology.

59 BASIC BIOLOGICAL SCIENCES↗