Search NASA⌕ Search

SEARCH · Search NASA

Results for “THERMOCOUPLE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Revision of the standard reference data for thermocouples.

Revision of the International Practical Temperature Scale requires that there be changes for all accurately tabulated thermophysical values. Revised reference data for thermocouples have been generated in a program carried out by the National Bureau of Standards. The new reference data reflect not only revisions in the temperature scale, but also slight changes in the materials themselves and improvements in data fitting methods. A new NBS monograph that contains tables, analytic expressions, various approximations, and explanatory text has been prepared. A general discussion of the project and some specific examples are given.

Powell, R. L.↗

Heat transfer tests of an 0.006-scale thin-skin space shuttle thermocouple model (41-OTS) in the Langley Research Center unitary plan wind tunnel at M equals 3.7 (IH16)

The results are presented of supersonic heat transfer tests performed on the .006 scale space shuttle vehicle model (41-OTS) in the Langley Research Center Unitary Plan Wind Tunnel. These tests were conducted to parametrically investigate ascent heating of the integrated vehicle and its components. The tests were conducted at a nominal Mach number of 3.7 and Reynolds numbers per foot of 2 and 5 million. The model configurations investigated were the integrated vehicle and each component alone (i.e. orbiter, tank and SRB). All the configurations were run with and without transition strips and through an angle of attack range of 0 deg to minus 5 deg with the exception of the SRB which was tested through an angle of attack range of minus 5 deg to 90 deg. The heat transfer data were obtained from 223 iron constantan thermocouples attached to stainless steel thin-skin areas of the model.

Walstad, D. G.↗

Heat transfer test of an 0.006-scale thin-skin thermocouple space shuttle model (50-0, 41-T) in the NASA-Ames Research Center 3.5-foot hypersonic wind tunnel at Mach 5.3 (IH28), volume 1

Data obtained from a heat transfer test conducted on an 0.006-scale space shuttle orbiter and external tank in the NASA-Ames Research Center 3.5-foot Hypersonic Wind Tunnel are presented. The purpose of this test was to obtain data under simulated return-to-launch-site abort conditions. Configurations tested were integrated orbiter and external tank, orbiter alone, and external tank alone at angles of attack of 0, + or - 30, + or - 60, + or - 90, and + or - 120 degrees. Runs were conducted at Mach numbers of 5.2 and 5.3 for Reynolds numbers of 1.0 and 4.0 million per foot, respectively. Heat transfer data were obtained from 75 orbiter and 75 external tank iron-constantan thermocouples.

Cummings, J. W.↗

Use of miniature, single-wire, sheathed thermocouples

Temperature measurement with small thermocouples is improved by device. Each wire is sheathed separately which increases the interelement insulation by factor of 2 1/2. Each wire in its separate sheath can be brought to junction by independent paths.

Glawe, G. E.↗

Recovery and radiation corrections and time constants of several sizes of shielded and unshielded thermocouple probes for measuring gas temperature

Performance characteristics were experimentally determined for several sizes of a shielded and unshielded thermocouple probe design. The probes are of swaged construction and were made of type K wire with a stainless steel sheath and shield and MgO insulation. The wire sizes ranged from 0.03- to 1.02-mm diameter for the unshielded design and from 0.16- to 0.81-mm diameter for the shielded design. The probes were tested through a Mach number range of 0.2 to 0.9, through a temperature range of room ambient to 1420 K, and through a total-pressure range of 0.03 to 0.2.2 MPa (0.3 to 22 atm). Tables and graphs are presented to aid in selecting a particular type and size. Recovery corrections, radiation corrections, and time constants were determined.

Glawe, G. E.↗

A thermocouple for hot, oxidizing environments

Thermocouple enclosed in nonoxidizing thermally conductive metal provides temperature probe which is made for very hot, highly oxidizing environments. Approach makes temperature measurement in hot, oxidizing atmospheres much easier task.

Jenkins, R. V.↗

An oven for many thermocouple reference junctions

Compact, lightweight oven designed with geometric and heating symmetry holds many junctions at stable temperature. Oven has cylindrical wall with all points equidistant from heating coil. Thermocouple junctions are inserted in holes bored radially in wall. Sensor controls power supplied to heating coil, maintaining cylinder wall and junctions at constant temperature.

Leblanc, L. P.↗

Reduced-Stress Mounting for Thermocouples

Mounting accommodates widely different coefficients of thermal expansion. In new method, legs of thermocouple placed in separate n- and p-type arrays. Two arrays contact common heat pipe as source but have separate heatpipe sinks. Net expansion (or contraction) taken up by spring mounting on heat-pipe sinks.

Wood, C.↗

High temperature thermocouple and heat flux gauge using a unique thin film-hardware hot juncture

A special thin film-hardware material thermocouple (TC) and heat flux gauge concept for a reasonably high temperature and high flux flat plate heat transfer experiment was fabricated and tested to gauge temperatures of 911 K. This concept was developed for minimal disturbance of boundary layer temperature and flow over the plates and minimal disturbance of heat flux through the plates. Comparison of special heat flux gauge Stanton number output at steady-state conditions with benchmark literature data was good and agreement was within a calculated uncertainty of the measurement system. Also, good agreement of special TC and standard TC outputs was obtained and the results are encouraging. Oxidation of thin film thermoelements was a primary failure mode after about 5 of operation.

Liebert, C. H.↗

High-temperature thermocouple and heat flux gauge using a unique thin film-hardware hot junction

A special thin film-hardware material thermocouple (TC) and heat flux gauge concept for a reasonably high temperature and high flux flat plate heat transfer experiment was fabricated and tested to gauge temperatures of 911 K. This concept was developed for minimal disturbance of boundary layer temperature and flow over the plates and minimal disturbance of heat flux through the plates. Comparison of special heat flux gauge Stanton number output at steady-state conditions with benchmark literature data was good and agreement was within a calculated uncertainty of the measurement system. Also, good agreement of special TC and standard TC outputs was obtained and the results are encouraging. Oxidation of thin film thermoelements was a primary failure mode after about 5 of operation.

Liebert, C. H.↗

Annealing Increases Stability Of Iridium Thermocouples

Metallurgical studies carried out on samples of iridium versus iridium/40-percent rhodium thermocouples in condition received from manufacturer. Metallurgical studies included x-ray, macroscopic, resistance, and metallographic studies. Revealed large amount of internal stress caused by cold-working during manufacturing, and large number of segregations and inhomogeneities. Samples annealed in furnace at temperatures from 1,000 to 2,000 degree C for intervals up to 1 h to study effects of heat treatment. Wire annealed by this procedure found to be ductile.

Germain, Edward F.↗

Attachment of lead wires to thin film thermocouples mounted on high temperature materials using the parallel gap welding process

Parallel gap resistance welding was used to attach lead wires to sputtered thin film sensors. Ranges of optimum welding parameters to produce an acceptable weld were determined. The thin film sensors were Pt13Rh/Pt thermocouples; they were mounted on substrates of MCrAlY-coated superalloys, aluminum oxide, silicon carbide and silicon nitride. The entire sensor system is designed to be used on aircraft engine parts. These sensor systems, including the thin-film-to-lead-wire connectors, were tested to 1000 C.

Holanda, Raymond↗

Measurement of frequency response in short thermocouple wires

Experimental measurements are made for the steady-state frequency response of a supported thermocouple wire. In particular, the effects of axial heat conduction are demonstrated for both a supported one material wire (type K) and a two material wire (type T) with unequal material properties across the junction. The data for the amplitude ratio and phase angle are correlated to within 10 percent with the theoretical predictions of Fralick and Forney (1991). This is accomplished by choosing a natural frequency omega(sub n) for the wire data to correlate the first order response at large gas temperature frequencies. It is found that a large bead size, however, will increase the amplitude ratio at low frequencies but decreas the natural frequency of the wire. The phase angle data are also distorted for imperfect junctions.

Forney, L. J.↗

Welding Wires To Thin Thermocouple Films

Parallel-gap resistance welding yields joints surviving temperatures of about 1,000 degrees C. Much faster than thermocompression bonding. Also exceeds conductive-paste bonding and sputtering thin films through porous flame-sprayed insulation on prewelded lead wires. Introduces no foreign material into thermocouple circuit and does not require careful control of thickness of flame-sprayed material.

Holanda, Raymond↗